Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 157: 92-99, 2018 Aug 05.
Article in English | MEDLINE | ID: mdl-29777985

ABSTRACT

A simple and precise ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the simultaneous analysis of five anti-infective agents used to treat severe infections [three antibiotics (daptomycin, moxifloxacin, ciprofloxacin) and two antifungals (isavuconazole, caspofungin)] in human plasma. Sample preparation was based on protein precipitation with ice cold methanol. All five agents were analyzed with the corresponding isotopically labeled internal standards. All analytes were detected in multiple reactions monitoring (MRM) using API 4000 triple-quadrupole mass spectrometer with electrospray (ESI) source operating in positive mode. The calibration curves were linear over the selected ranges (r > 0.99). The method is precise and accurate with a total run time of 5.5 min. Accuracy of all target analytes ranged between 95.9-116.6%, measured with an imprecision of less than 10.8%. The lower limit of quantification was 1.25 mg/L for caspofungin, 0.3125 mg/L for isavuconazole, 3.125 mg/L for daptomycin, 0.075 mg/L for ciprofloxacin, and 0.1875 mg/L for moxifloxacin. The successful application of the method in patient samples proved its suitability for the medical surveillance of antimicrobial therapy in intensive care units as well as to other pharmacokinetic studies.


Subject(s)
Chromatography, High Pressure Liquid/methods , Ciprofloxacin/blood , Daptomycin/blood , Echinocandins/blood , Fluoroquinolones/blood , Lipopeptides/blood , Nitriles/chemistry , Pyridines/chemistry , Tandem Mass Spectrometry/methods , Triazoles/chemistry , Anti-Bacterial Agents/blood , Antifungal Agents/blood , Caspofungin , Humans , Limit of Detection , Moxifloxacin , Plasma/chemistry , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization/methods
2.
Drug Test Anal ; 10(3): 584-591, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28753737

ABSTRACT

A large variation in the levels of different ß-lactams and other antibiotics used in critically ill patients has been documented. The aim of this study is to establish and validate a fast, ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous analysis of ten antibiotics (Meropenem, Cefepime, Ceftazidime, Piperacillin, Benzylpenicillin, Ampicillin, Flucloxacillin, Linezolid, and Sulfamethoxazole/Trimethoprim) in human plasma according to European Medicines Agency (EMA) guidelines. Protein precipitation with ice-cold methanol containing 9 isotopically labeled internal standards was used for sample clean up. Antibiotics were detected, following a 4-minute gradient separation, in multiple reactions monitoring (MRM) using API 4000 instrument equipped with electrospray source operating in positive ion mode. The lower limit of quantification was 0.1 mg/L for Meropenem, Ceftazidime, Piperacillin, Ampicillin, Flucloxacillin, and Sulfamethoxazole; 0.05 mg/L for Cefepime, Benzylpenicillin, and Trimethoprim; and 0.02 mg/L for Linezolid. The method proved to be precise and accurate and applicable for therapeutic drug monitoring and other pharmacokinetic studies.


Subject(s)
Anti-Bacterial Agents/blood , Chromatography, High Pressure Liquid/methods , Drug Monitoring/methods , Tandem Mass Spectrometry/methods , Chemical Precipitation , Humans , Intensive Care Units , Limit of Detection
SELECTION OF CITATIONS