Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Diagn Interv Imaging ; 97(4): 443-9, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26896374

ABSTRACT

PURPOSE: To compare the radiation dose and image quality, focused mainly on cardiac pulsation artifact, between high-pitch low-dose chest computed tomography (HP-LDCT) and standard low-dose chest CT (LDCT). PATIENTS AND METHODS: One hundred patients underwent HP-LDCT (50 patients) or LDCT (50 patients). Scan parameters were the same except for the pitch and gantry rotation time: 3.0 vs. 1.2 and 0.28s vs. 0.5s, respectively. Objective image noise at five regions and subjective image quality, such as noise, artifacts, cardiac pulsation artifacts, and overall diagnostic acceptability, were evaluated using a five-point scale. The significance level for all tests was set at P<0.05. RESULTS: The dose-length products (DLPs) with HP-LDCT and LDCT were 90.2±4.3mGycm and 103.1±6.4mGycm, respectively (P<0.01). DLP of HP-LDCT showed a 13% reduction versus LDCT. Objective image noise was not significantly different. Cardiac pulsation artifacts showed a significant reduction on HP-LDCT (P<0.01). Other subjective image quality parameters of HP-LDCT were similar to those of LDCT. The overall diagnostic acceptability of HP-LDCT was better than that of LDCT (P<0.01). CONCLUSIONS: HP-LDCT showed a 13% mean radiation dose reduction with no deterioration in image quality due to cardiac pulsation artifacts.


Subject(s)
Artifacts , Heart/physiology , Radiation Dosage , Tomography, X-Ray Computed/methods , Feasibility Studies , Female , Humans , Middle Aged
3.
AJNR Am J Neuroradiol ; 29(4): 781-5, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18310234

ABSTRACT

BACKGROUND AND PURPOSE: There are a few reports regarding the outcome evaluation of balloon-expandable intracranial stent placement (BEICS). The purpose of our study was to evaluate the outcome and factors related to the adverse events (AEs) of BEICS. MATERIALS AND METHODS: We evaluated 100 consecutive patients who underwent BEICS. We assessed the procedural success (residual stenosis < 50%), AEs (minor strokes, major strokes, and death), clinical outcome, and restenosis (> 50%) at 6 months. We also analyzed 18 factors including symptom patterns related to AE rate. Symptom patterns revealed 1) stable patients (n = 73) with improving, stationary, or resolved symptoms; and 2) unstable patients (n = 27) with gradual worsening or fluctuating symptoms (National Institutes of Health Stroke Scale [NIHSS] > or = 4) within 2 days before stent placement. RESULTS: The procedural success rate was 99%. Overall, there were 10 (10%) AEs within the 6 months: 4 (4%) minor strokes, 3 (3%) major strokes, and 3 (3%) deaths including a death from myocardial infarction. AE rate was 4.1% in stable and 25.9% in unstable patients. Restenosis at 6 months revealed 0% (0/59). Good outcome (modified Rankin Scale < or = 2) at 6 months was 97% (71/73) in stable and 67% (18/27) in unstable patients. Stepwise logistic regression model revealed that symptom pattern (unstable versus stable) was the only significant risk factor (OR, 8.167; 95% CI, 1.933-34.500; P = .004). CONCLUSION: BEICS revealed a low AE and good outcome rate at 6 months, especially in the stable patients. Midterm outcome was also favorable in the unstable patient group.


Subject(s)
Angioplasty, Balloon , Intracranial Arteriosclerosis/therapy , Stents , Adult , Aged , Aged, 80 and over , Basilar Artery/pathology , Carotid Artery, Internal/pathology , Constriction, Pathologic , Female , Humans , Intracranial Arteriosclerosis/complications , Intracranial Arteriosclerosis/pathology , Male , Middle Aged , Middle Cerebral Artery/pathology , Stroke/etiology , Vertebral Artery/pathology
4.
Phys Rev Lett ; 88(22): 226803, 2002 Jun 03.
Article in English | MEDLINE | ID: mdl-12059443

ABSTRACT

We show theoretically that in quantum wells subjected to a strong magnetic field the intersubband current peaks at magnetic field values, which reveal the underlying specific intersubband scattering mechanism. We have designed and grown a superlattice structure in which such current oscillations are clearly visible, and in which the transition from the purely single-electron to the mixed single- and two-electron scattering regimes can be observed by tuning the applied voltage bias. The measurements were conducted in ultrahigh magnetic fields (up to 45 T) to obtain the full spectrum of the current oscillations.

SELECTION OF CITATIONS
SEARCH DETAIL
...