Berl Munch Tierarztl Wochenschr ; 124(5-6): 247-56, 2011.
Article in German | MEDLINE | ID: mdl-22059297

ABSTRACT

The influence of the application modes (bolus injection, infusion) of the sonographic signal enhancers Levovist was investigated in a total of 24 dogs. The animals in the bolus group were given 0.2 ml/kg body mass Levovist at a concentration of 300 mg/ml while in the other group the same amount was continuously injected over a time of two minutes. Signal enhancement was measured by an audiodoppler. Contrast duration above six, twelve, 18 and 24 dB and maximum signal enhancement were determined for each application mode. The comparison of these parameters showed that a statistically significant longer contrast duration (significance level p less than 0,05) at 0 and 6 dB can be achieved by continuous injection. Bolus application, on the other hand, resulted in significantly higher maximum contrast enhancement. With time consuming investigations (perfusiondiagnostic, shuntdiagnostic) the contrast effect can be partly extended with continuous injection but the technical requirements are higher and there is the risk that the acoustic properties of the microbubbles are negatively influenced.


Subject(s)
Contrast Media , Polysaccharides , Ultrasonography, Doppler/veterinary , Animals , Contrast Media/administration & dosage , Dogs , Female , Image Enhancement/methods , Male , Polysaccharides/administration & dosage , Signal Processing, Computer-Assisted , Ultrasonography, Doppler/standards