Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
JAMA Surg ; 156(5): e207259, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33760010

ABSTRACT

Importance: Despite the widespread use of systemic antibiotics to prevent infections in surgically treated patients with fracture, high rates of surgical site infection persist. Objective: To examine the effect of intrawound vancomycin powder in reducing deep surgical site infections. Design, Setting, and Participants: This open-label randomized clinical trial enrolled adult patients with an operatively treated tibial plateau or pilon fracture who met the criteria for a high risk of infection from January 1, 2015, through June 30, 2017, with 12 months of follow-up (final follow-up assessments completed in April 2018) at 36 US trauma centers. Interventions: A standard infection prevention protocol with (n = 481) or without (n = 499) 1000 mg of intrawound vancomycin powder. Main Outcomes and Measures: The primary outcome was a deep surgical site infection within 182 days of definitive fracture fixation. A post hoc comparison assessed the treatment effect on gram-positive and gram-negative-only infections. Other secondary outcomes included superficial surgical site infection, nonunion, and wound dehiscence. Results: The analysis included 980 patients (mean [SD] age, 45.7 [13.7] years; 617 [63.0%] male) with 91% of the expected person-time of follow-up for the primary outcome. Within 182 days, deep surgical site infection was observed in 29 of 481 patients in the treatment group and 46 of 499 patients in the control group. The time-to-event estimated probability of deep infection by 182 days was 6.4% in the treatment group and 9.8% in the control group (risk difference, -3.4%; 95% CI, -6.9% to 0.1%; P = .06). A post hoc analysis of the effect of treatment on gram-positive (risk difference, -3.7%; 95% CI, -6.7% to -0.8%; P = .02) and gram-negative-only (risk difference, 0.3%; 95% CI, -1.6% to 2.1%; P = .78) infections found that the effect of vancomycin powder was a result of its reduction in gram-positive infections. Conclusions and Relevance: Among patients with operatively treated tibial articular fractures at a high risk of infection, intrawound vancomycin powder at the time of definitive fracture fixation reduced the risk of a gram-positive deep surgical site infection, consistent with the activity of vancomycin. Trial Registration: ClinicalTrials.gov Identifier: NCT02227446.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Gram-Negative Bacterial Infections/prevention & control , Gram-Positive Bacterial Infections/prevention & control , Surgical Wound Infection/prevention & control , Tibial Fractures/surgery , Vancomycin/therapeutic use , Adult , Anti-Bacterial Agents/administration & dosage , Double-Blind Method , Female , Fracture Fixation, Internal/adverse effects , Fractures, Ununited/etiology , Humans , Intra-Articular Fractures/surgery , Male , Middle Aged , Powders , Probability , Prospective Studies , Surgical Wound Dehiscence/etiology , Surgical Wound Infection/etiology , Time Factors , Vancomycin/administration & dosage
2.
Am J Med ; 127(1): 95.e11-7, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24384108

ABSTRACT

BACKGROUND: Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration-cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS: A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar's tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS: Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS: Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Electrocardiography, Ambulatory , Electrocardiography/methods , Adhesives , Adult , Aged , Arrhythmias, Cardiac/physiopathology , Atrial Fibrillation/diagnosis , Atrial Flutter/diagnosis , Atrioventricular Block/diagnosis , Equipment Design , Female , Humans , Male , Middle Aged , Patient Satisfaction , Tachycardia, Supraventricular/diagnosis , Tachycardia, Ventricular/diagnosis , Time Factors , Ventricular Fibrillation/diagnosis
3.
Sci Transl Med ; 4(126): 126ra33, 2012 Mar 21.
Article in English | MEDLINE | ID: mdl-22440735

ABSTRACT

Acute myocardial infarction (MI), which involves the rupture of existing atheromatous plaque, remains highly unpredictable despite recent advances in the diagnosis and treatment of coronary artery disease. Accordingly, a clinical measurement that can predict an impending MI is desperately needed. Here, we characterize circulating endothelial cells (CECs) using an automated and clinically feasible CEC three-channel fluorescence microscopy assay in 50 consecutive patients with ST-segment elevation MI and 44 consecutive healthy controls. CEC counts were significantly elevated in MI cases versus controls, with median numbers of 19 and 4 cells/ml, respectively (P = 1.1 × 10(-10)). A receiver-operating characteristic (ROC) curve analysis demonstrated an area under the ROC curve of 0.95, suggesting near-dichotomization of MI cases versus controls. We observed no correlation between CECs and typical markers of myocardial necrosis (ρ = 0.02, creatine kinase-myocardial band; ρ = -0.03, troponin). Morphological analysis of the microscopy images of CECs revealed a 2.5-fold increase (P < 0.0001) in cellular area and a twofold increase (P < 0.0001) in nuclear area of MI CECs versus healthy controls, age-matched CECs, as well as CECs obtained from patients with preexisting peripheral vascular disease. The distribution of CEC images that contained from 2 to 10 nuclei demonstrates that MI patients were the only subject group to contain more than 3 nuclei per image, indicating that multicellular and multinuclear clusters are specific for acute MI. These data indicate that CEC counts may serve as a promising clinical measure for the prediction of atherosclerotic plaque rupture events.


Subject(s)
Cell Movement , Endothelial Cells , Myocardial Infarction/pathology , Adult , Aged , Aged, 80 and over , Arteries/injuries , Arteries/pathology , Biomarkers/metabolism , Case-Control Studies , Cell Count , Cell Nucleus/pathology , Cell Shape , Cell Size , Endothelial Cells/cytology , Endothelial Cells/pathology , Female , Humans , Male , Microscopy, Fluorescence , Middle Aged , Necrosis , Phenotype
SELECTION OF CITATIONS
SEARCH DETAIL
...