Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Lasers Surg Med ; 56(4): 371-381, 2024 04.
Article in English | MEDLINE | ID: mdl-38563442

ABSTRACT

OBJECTIVES: To develop and practically test high-precision femtosecond laser ablation models for dental hard tissue that are useful for detailed planning of automated laser dental restorative treatment. METHODS: Analytical models are proposed, derived, and demonstrated for practical calculation of ablation rates, ablation efficiency and ablated morphology of human dental enamel and dentin using femtosecond lasers. The models assume an effective optical attenuation coefficient for the irradiated material. To achieve ablation, it is necessary for the local energy density of the attenuated pulse in the hard tissue to surpass a predefined threshold that signifies the minimum energy density required for material ionization. A 1029 nm, 40 W carbide 275 fs laser was used to ablate sliced adult human teeth and generate the data necessary for testing the models. The volume of material removed, and the shape of the ablated channel were measured using optical profilometry. RESULTS: The models fit with the measured ablation efficiency curve against laser fluence for both enamel and dentin, correctly capturing the fluence for optimum ablation and the volume of ablated material per pulse. The detailed shapes of a 400-micrometer wide channel and a single-pulse width channel are accurately predicted using the superposition of the analytical result for a single pulse. CONCLUSIONS: The findings have value for planning automated dental restorative treatment using femtosecond lasers. The measurements and analysis give estimates of the optical properties of enamel and dentin irradiated with an infrared femtosecond laser at above-threshold fluence and the proposed models give insight into the physics of femtosecond laser processing of dental hard tissue.


Subject(s)
Laser Therapy , Tooth , Humans , Dentin/surgery , Lasers , Light
2.
Sci Rep ; 13(1): 20156, 2023 11 17.
Article in English | MEDLINE | ID: mdl-37978230

ABSTRACT

We investigated the effect of femtosecond (fs) laser ablation of enamel and dentin for different pulse wavelengths: infrared (1030 nm), green (515 nm), and ultra-violet (343 nm) and for different pulse separations to determine the optimal irradiation conditions for the precise removal of dental hard tissues with the absence of structural and compositional damage. The ablation rates and efficiencies were established for all three laser wavelengths for both enamel and dentin at room temperature without using any irrigation or cooling system, and the surfaces were assessed with optical and scanning electron microscopy, optical profilometry, and Raman spectroscopy. We demonstrated that 515 nm fs irradiation provides the highest rate and efficiency for ablation, followed by infrared. Finally, we explored the temperature variations inside the dental pulp during the laser procedures for all three wavelengths and showed that the maximum increase at the optimum conditions for both infrared and green irradiations was 5.5 °C, within the acceptable limit of temperature increase during conventional dental treatments. Ultra-violet irradiation significantly increased the internal temperature of the teeth, well above the acceptable limit, and caused severe damage to tooth structures. Thus, ultra-violet is not a compatible laser wavelength for femtosecond teeth ablation.


Subject(s)
Dentin , Laser Therapy , Dentin/radiation effects , Lasers , Laser Therapy/methods , Temperature , Dental Enamel
3.
Biomed Opt Express ; 13(9): 4559-4571, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36187240

ABSTRACT

High fluence focused femtosecond laser pulses were used to perform fast, high precision and minimally damaging cavity cutting of teeth at room temperature without using any irrigation or cooling system. The optimal ablation rates were established for both enamel and dentin, and the surfaces were assessed with optical and scanning electron microscopy, Raman spectroscopy and optical profilometry. No chemical change in the composition of enamel and dentin was observed. We explored temperature variations inside the dental pulp during the laser procedure and showed the maximum increase was 5.5°C, within the acceptable limit of temperature increase during conventional dental treatments.

SELECTION OF CITATIONS
SEARCH DETAIL
...