Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
2.
Radiologie (Heidelb) ; 64(4): 278-286, 2024 Apr.
Article in German | MEDLINE | ID: mdl-38483571

ABSTRACT

Patellofemoral instability (PFI) describes a (sub)luxation of the patella in the patellofemoral joint. Pathophysiologically, PFI is usually due to a nonphysiological movement of the patella, so-called maltracking, either due to acute trauma with injury to the supporting ligamentous apparatus or due to the presence of anatomical risk factors. Radiologically assessable risk factors for maltracking include trochlear dysplasia, patella alta, patellar tilt, lateralization of the tibial tuberosity, torsional deformity and genu valgum. This article presents the most commonly used and best validated measurement techniques. In addition, the characteristic injury pattern after lateral patellar dislocation is shown.


Subject(s)
Gastropoda , Joint Dislocations , Joint Instability , Patellar Dislocation , Patellofemoral Joint , Animals , Patella
3.
Spine J ; 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38301903

ABSTRACT

BACKGROUND CONTEXT: The motion limitation after cervical discectomy and fusion alters the spine´s kinematics. Unphysiological strains may be the result and possible explanation for adjacent segment degeneration. Alterations to cervical kinematics due to cervical total disc replacement (TDR), especially two-level, are still under investigated. PURPOSE: To investigate cervical motion including coupled motions after one-level and two-level TDR in the treated and also the adjacent segments. STUDY DESIGN: An in-vitro study using pure moment loading of human donor spines. METHODS: Seven fresh frozen human cervical spine specimens (C4-T1, median age 46 with range 19-60 years, four female) were included in this study. Specimens were tested in the intact condition first, followed by one-level TDR at C5-6 which was subsequently extended one level further caudal (C5-7). Each specimen was quasistatically loaded with pure moments up to 1.5 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) in a universal spine tester for 3.5 cycles at 1 °/s. During the tests three dimensional motion tracking was performed for each vertebral body individually. From that, the primary and coupled ROM of each spinal level during the third full cycle of motion were evaluated. Nonparametric statistical analysis was performed using a Friedman-test and post-hoc correction with Dunn-Bonferroni-tests (p<.05). Ethics approval was obtained in advance. RESULTS: In FE, one-level TDR (C5-6) moderately increased primary FE in all four segments, but only significantly at the cranial adjacent level C4-5. Additional TDR at C6-7 further increased the ROM at the target segment without much influence on the other levels. Increasing implant height at C6-7 partially counteracted the increased FE. Coupled motions were minimal in all test conditions at all levels. In LB, coupled AR was observed in all test conditions at all levels. One-level TDR decreased primary LB at the target segment C5-6 significantly, without much influence on the other levels. Extending TDR to C6-7 decreased ROM in the target segment but without gaining statistical significance. Increasing implant height at C6-7 further decreased primary LB at the target segment, still without significance. Notably, coupled AR was significantly decreased at the cranial adjacent segment C4-5 compared to the intact condition. In AR, coupled LB was observed in all test conditions at the levels C4-5, C5-6, and C6-7, while the transition level to the thoracic spine C7-T1 showed only little coupled LB. Both one-level and two-level TDR showed little influence on primary AR or coupled motions at any level. Only after increasing implant height at C6-7 was the motion of the caudally adjacent level C7-T1 significantly altered. CONCLUSION: Evaluating primary FE, LB, and AR together with the associated coupled motions revealed widespread influence of cervical TDR not only on the motion of the treated level but also at the adjacent segments. The influence of two-level TDR is more widespread and involves more levels than one-level TDR. CLINICAL SIGNIFICANCE: The prevention of unphysiological strains due to altered kinematics after cervical fusion, which could possibly explain adjacent segment degeneration, were a driving factor in the development of TDR. These experimental findings suggest cervical TDR influences the whole cervical spine, not only the treated segment. The effect becomes more extensive, involving more levels and motion directions, after two-level than after one-level TDR.

4.
Radiat Res ; 201(5): 396-405, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38282002

ABSTRACT

After nuclear scenarios, combined injuries of acute radiation syndrome (ARS) with, e.g., abdominal trauma, will occur and may require contrast-enhanced computed tomography (CT) scans for diagnostic purposes. Here, we investigated the effect of iodinated contrast agents on radiation-induced gene expression (GE) changes used for biodosimetry (AEN, BAX, CDKN1A, EDA2R, APOBEC3H) and for hematologic ARS severity prediction (FDXR, DDB2, WNT3, POU2AF1), and on the induction of double-strand breaks (DSBs) used for biodosimetry. Whole blood samples from 10 healthy donors (5 males, 5 females, mean age: 28 ± 2 years) were irradiated with X rays (0, 1 and 4 Gy) with and without the addition of iodinated contrast agent (0.016 ml contrast agent/ml blood) to the blood prior to the exposure. The amount of contrast agent was set to be equivalent to the blood concentration of an average patient (80 kg) during a contrast-enhanced CT scan. After irradiation, blood samples were incubated at 37°C for 20 min (DSB) and 8 h (GE, DSB). GE was measured employing quantitative real-time polymerase chain reaction. DSB foci were revealed by γH2AX + 53BP1 immunostaining and quantified automatically in >927 cells/sample. Radiation-induced differential gene expression (DGE) and DSB foci were calculated using the respective unexposed sample without supplementation of contrast agent as the reference. Neither the GE nor the number of DSB foci was significantly (P = 0.07-0.94) altered by the contrast agent application. However, for some GE and DSB comparisons with/without contrast agent, there were weakly significant differences (P = 0.03-0.04) without an inherent logic and thus are likely due to inter-individual variation. In nuclear events, the diagnostics of combined injuries can require the use of an iodinated contrast agent, which, according to our results, does not alter or influence radiation-induced GE changes and the quantity of DSB foci. Therefore, the gene expression and γH2AX focus assay can still be applied for biodosimetry and/or hematologic ARS severity prediction in such scenarios.


Subject(s)
Contrast Media , DNA Breaks, Double-Stranded , Tomography, X-Ray Computed , Humans , Male , Female , Adult , DNA Breaks, Double-Stranded/radiation effects , DNA Breaks, Double-Stranded/drug effects , Gene Expression Regulation/radiation effects , Gene Expression Regulation/drug effects
5.
Unfallchirurgie (Heidelb) ; 126(11): 856-862, 2023 Nov.
Article in German | MEDLINE | ID: mdl-37910187

ABSTRACT

BACKGROUND: Soldiers, especially as recruits, are exposed to significantly elevated stress patterns of the foot due to occupation-related marching and excessive running. This can lead to military-specific stress fractures of the metatarsals, i.e., marching fractures. The treatment and prevention of stress fractures are of particular importance in the military context due to the impact on operational capability and treatment costs. A uniform classification of these fractures does not yet exist. OBJECTIVE: Review of stress fractures in the military setting with presentation of the incidence, risk factors, classification, treatment and prevention possibilities. MATERIAL AND METHODS: A PubMed®-based review of the current literature on stress fractures in the military context was conducted and the results were discussed with a focus on specific military medical treatment options. RESULTS: There are several possibilities to classify stress fractures, the most well-known being a 4-level magnetic resonance imaging (MRI)-based classification. Prevention and treatment possibilities are multifaceted but so far insufficiently validated. CONCLUSION: Military-specific stress fractures should be grouped according to a 4-level and MRI-based classification. The treatment options include both conservative and surgical measures and should be implemented taking the patient's individual requirements into account. Preventive measures play a key role in the military context. They include the adaptation of screening tools, training and equipment and require continuous evaluation and development.


Subject(s)
Fractures, Stress , Metatarsal Bones , Military Personnel , Humans , Fractures, Stress/diagnosis , Lower Extremity , Magnetic Resonance Imaging
6.
Eur J Radiol ; 169: 111157, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37871356

ABSTRACT

PURPOSE: Since organ-based tube current modulation (OBTCM) and tin prefiltration are limited on their own in lowering the dose of lung CT examinations, this experimental study was designed to investigate whether combinations with anterior patient shielding can increase the dose reduction potential. MATERIAL AND METHODS: Three pairs of scan protocols without/with breast shield (P1/P2: standard 120kVp, P3/P4: OBTCM at 100 kVp, P5/P6: Sn 100 kVp) were employed for radiation exposure and image quality comparisons on an anthropomorphic Alderson-Rando phantom. Equivalent doses were measured in eleven sites via thermoluminescent dosimetry and the effective dose was obtained by summation of the weighted organ doses. Dose-weighted contrast-to-noise ratios (CNRD) were calculated and four radiologists independently assessed the quality of images generated with each protocol. RESULTS: While no significant difference was determined between standard and OBTCM protocols regardless of breast shield (p ≥ 0.068), equivalent doses with spectral shaping were substantially lower (p ≤ 0.003). The highest effective dose was ascertained for standard scans (P1/P2: 7.3/6.8 mSv) with a dose reduction of 8.0 % via breast shielding. The use of a bismuth shield was more beneficial in OBTCM (P3/P4: 6.6/5.3 mSv) and spectral shaping (P5/P6: 0.7/0.6 mSv), reducing the effective dose by 19.8 % and 13.9 %, respectively. Subjective assessment favoured standard protocol P1 over tin prefiltration low-dose scans (p ≤ 0.032), however, no scan protocol entailed diagnostically insufficient image quality. CONCLUSIONS: Whereas breast shielding is particularly beneficial in combination with OBTCM, spectral shaping via tin prefiltration facilitates the most pronounced dose reduction in lung CT imaging with acceptable image quality.


Subject(s)
Bismuth , Tin , Humans , Radiation Dosage , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Lung/diagnostic imaging
7.
Acta Cardiol ; 78(9): 1045-1050, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37606342

ABSTRACT

BACKGROUND: Myocardial deformation parameters have been shown to yield early detection of pathological changes in chronic heart failure (CHF). Aim of our study was to evaluate myocardial deformation changes under optimal medical therapy (OMT) in CHF patients. METHODS: CHF patients were examined longitudinally with two cardiac magnetic resonance imaging (CMR) examinations at a median time interval of 140 days. Left and right ventricular volumes were quantified, and deformation analysis was performed using feature tracking, respectively. RESULTS: 57 patients were included into the study. There was a high rate of OMT with a prescription of beta blockers in 98.2% and ACE-inhibitors/Angiotensin receptor blockers in 93.0%. In the total cohort, there were indications of positive remodelling with a significant improvement in left ventricular (LV) ejection fraction (38.9% ± 11.6 vs. 43.0% ± 12.7, p = 0.009), LV enddiastolic volume indexed (92.1 ml/m2 ± 23.5 vs. 87.2 ml/m2 ± 21.2, p = 0.007), LV mass (140.3 g ± 35.7 vs. 128.0 g ± 34.4, p = 0.001) and right ventricular global longitudinal strain (RV GLS) (-18.1% ± 5.1 vs. -20.3% ± 4.5, p < 0.001) during follow-up. DISCUSSION: Patients with CHF and OMT show positive reverse remodelling with improvement of LV volumes and function and RV GLS. This has a potential impact on the surveillance of this patient group, which should be further investigated in larger prospective studies.

8.
Int J Cardiovasc Imaging ; 39(11): 2205-2215, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37436643

ABSTRACT

Chronic total occlusion (CTO) is a common finding in patients with known or suspected coronary artery disease and has a distinctive role in these patients' quality of life. However, there is still a lack of evidence of correct patient selection for percutaneous coronary intervention (PCI). From July 2017 to August 2020, 68 patients with successful PCI of a CTO and previous evidence of viability for PCI by cardiovascular magnetic resonance imaging (CMR) were prospectively included in this single-centre observational study. Of these patients, 62 underwent follow-up CMR, and 56 underwent surveys using the Seattle Angina Questionnaire before PCI and 3, 12 and 24 months after PCI. The CMR results were assessed for volumetric, functional and deformation parameters. From the baseline to the follow-up, there was a significant reduction in the left ventricular volumes (all p < 0.001) and an increase in the left ventricular ejection fraction (57.6 ± 11.6% vs. 60.3 ± 9.4%, p = 0.006). Among the deformation parameters, only the left ventricular radial strain showed significant improvement. The SAQ showed an early improvement that emphasised angina stability and frequency as well as a summary score, which persisted after 24 months. A low SAQ summary score before PCI was the best predictive factor of good clinical improvement thereafter. Improvements in myocardial function and quality of life can be achieved with PCI of a CTO. Patient selection for PCI should be performed primarily among relevantly symptomatic patients when evidence of viability for PCI is present. The SAQ can help guide such patient selection.Trial registration ISRCTN, identifier: ISRCTN33203221. Retrospectively registered on 01.04.2020. https://www.isrctn.com/ISRCTN33203221.


Subject(s)
Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Angina Pectoris/diagnostic imaging , Angina Pectoris/therapy , Chronic Disease , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Coronary Occlusion/etiology , Myocardium , Predictive Value of Tests , Quality of Life , Stroke Volume , Treatment Outcome , Ventricular Function, Left
9.
Head Face Med ; 19(1): 28, 2023 Jul 10.
Article in English | MEDLINE | ID: mdl-37430304

ABSTRACT

BACKGROUND: Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed. METHODS: The computed tomography dose index (CTDIVol) and dose length product (DLP) of a total of 1246 patients (average age: 41 ± 18 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable. RESULTS: Over the past 12 years, there was a 73%, 54%, and 66% CTDIVol reduction and a significant (p < 0.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively. CONCLUSION: Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.


Subject(s)
Paranasal Sinuses , Radiation Dosage , Tomography, X-Ray Computed , Adult , Female , Humans , Male , Middle Aged , Young Adult , Retrospective Studies , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/trends , Paranasal Sinuses/diagnostic imaging
12.
Radiologie (Heidelb) ; 63(4): 259-267, 2023 Apr.
Article in German | MEDLINE | ID: mdl-36882548

ABSTRACT

Bone stress injuries is an umbrella term that encompasses repetitive microtraumatic events that accumulate to surpass the threshold of bone failure, which can range from bone marrow edema to frank stress fracture as the end point. Due to nonspecific clinical complaints and physical findings, imaging plays a central role in the diagnostic workup of these entities. Magnetic resonance imaging (MRI) is the most important imaging modality with a high sensitivity and specificity and allows for differential diagnosis of other diseases. Edema-sensitive with fat suppression and T1-weighted sequences are the core sequence types, and contrast-enhanced imaging-albeit displaying subtle fractures much more easily-is rarely necessary. Furthermore, MRI enables differentiation of injury severity, which has an impact on length of rehabilitation, therapeutic regimen, and the time to return to sports in athletes.


Subject(s)
Athletic Injuries , Bone Marrow Diseases , Fractures, Stress , Humans , Fractures, Stress/diagnostic imaging , Fractures, Stress/therapy , Magnetic Resonance Imaging/methods , Bone Marrow Diseases/pathology , Athletic Injuries/diagnosis , Athletic Injuries/therapy , Edema/diagnosis , Edema/pathology
13.
Int J Radiat Biol ; 99(10): 1584-1594, 2023.
Article in English | MEDLINE | ID: mdl-36988552

ABSTRACT

OBJECTIVE: Recently, promising radiation-induced EDA2R gene expression (GE) changes after low level radiation could be shown. Stimulated by that, in this study, we intended to independently validate these findings and to further characterize dose-response relationships in comparison to FDXR and the γH2AX-DNA double-strand break (DSB) focus assay, since both assays are already widely used for biodosimetry purposes. MATERIALS AND METHODS: Peripheral blood samples from six healthy human donors were irradiated ex vivo (dose: ranging from 2.6 to 49.7 mGy). Subsequently, the fold-differences relative to the sham irradiated reference group were calculated. Radiation-induced changes in GE of FDXR and EDA2R were examined using the quantitative real-time polymerase-chain-reaction (qRT-PCR). DSB foci were quantified in 100 γH2AX + 53BP1 immunostained cells employing fluorescence microscopy. Examinations were performed at single time points enabling sufficient detection of both endpoints. RESULTS: A significant increase in EDA2R GE relative to the unexposed control was observed in the range of 2.6 mGy (1.6-fold, p = .045) to 5.4 mGy (2.2-fold, p = .0002), whereas the copy numbers increased linearly up to 13.1-fold at 49.7 mGy. On the contrary, FDXR upregulation (2.2-fold) became significant after a 22.6 mGy exposure (p ≤ .02) and increased linearly up to 4-fold at 49.7 mGy. A significant increase in radiation-induced foci (relative to unexposed, RIF-fd) was observed after 11.3 mGy (RIF-fd: 1.5 ± 0.5, p ≤ .03), while the foci increased linearly up to 3-fold at 49.7 mGy. From this, the FDXR and RIF-fd slopes have shown comparability, while the EDA2R slope was five times higher. Nevertheless, the coefficient of variation (CV) of EDA2R was about 30% higher than for RIF-fd. CONCLUSION: Higher radiation-induced EDA2R GE changes and a lower radiation detection level compared to RIF-fd and FDXR GE changes examined under optimal conditions ex vivo on human samples appear promising. Yet, our results represent just the beginning of further studies to be conducted in animal models for further time- and dose-dependent evaluation and additional examinations on radiologically examined patients to evaluate the impact of confounder, such as age, sex, social behavior, or diseases.


Subject(s)
Biological Assay , Radiation Exposure , Animals , Humans , Dose-Response Relationship, Radiation , Biological Assay/methods , Radiation Exposure/adverse effects , Gene Expression
14.
PLoS One ; 18(1): e0279907, 2023.
Article in English | MEDLINE | ID: mdl-36607911

ABSTRACT

OBJECTIVES: Paranasal sinus imaging due to chronic inflammatory disease is one of the most common examinations in head and neck radiology with CT imaging considered the current gold standard. In this phantom study we analyzed different low dose CT protocols in terms of image quality, radiation exposure and subjective evaluation in order to establish an optimized scanning protocol. METHODS: In a phantom study, an Alderson phantom was scanned using 12 protocols between 70-120 kV and 25-200 mAs with and without tin filtration. For all datasets, iterative reconstruction was used. Data were objectively evaluated (image noise, (dose-weighted) contrast-to-noise ratio) and for subjective evaluation an online survey using a Likert scale was performed to reach a large group of clinically experienced reader (n = 62). The protocol was considered diagnostically insufficient if the median score was 4 and above and if more than 10% of raters scored 4 and above on the Likert scale. For an interreader agreement an ICC was calculated. To compare clinical value in relation to the applied dose and the objective image parameters, we calculated a figure of merit (FOM) and ranked the protocols accordingly. RESULTS: There was an overall moderate agreement between the 62 readers for the 12 examined CT protocols. In this phantom study, protocols with 100 kV with spectral shaping and 50-100 mAs obtained the best results for its combination of dose, image quality and clinical information value for diagnosing sinusitis (FOM 1st- 2nd place) with the 70 kV and 50 mAs as a good alternative as well (Sinusitis: FOM shared 2nd). For preoperative planning, where a higher dose is necessary, 100 kV with spectral shaping and 100 mAs achieved the overall best results (FOM 1st place) with 70 kV and 50 mAs ranking 4th. CONCLUSION: 100-kV protocols with spectral shaping or low kV protocols (70 kV) with a similarly low dose showed the best figure of merit for imaging sinonasal disease and preoperative planning. With modern scanner technology available, spectral shaping or low KV protocols should be used for sinusitis imaging.


Subject(s)
Sinusitis , Tin , Humans , Radiation Dosage , Tomography, X-Ray Computed/methods , Radiographic Image Enhancement/methods , Sinusitis/diagnostic imaging , Phantoms, Imaging
15.
Br J Neurosurg ; 37(4): 641-646, 2023 Aug.
Article in English | MEDLINE | ID: mdl-30431381

ABSTRACT

We report the case of a 61-year-old male with spindle cell oncocytoma of the hypophysis. On presentation to the Department of Neurosurgery at the German Armed Forces Hospital of Ulm, the patient reported a history of several years of left sixth nerve palsy, right ptosis, increased sensitivity to light, and a bilateral retrobulbar pressure sensation. Pituitary function was normal. A chromophobe non-functioning pituitary adenoma was initially suspected. The diagnosis was established on the basis of examination at a histopathology reference laboratory using immunohistochemistry to identify cell surface markers. During two years of follow-up, there were two clinical recurrences requiring surgery. To our knowledge, this is the 35th documented case of spindle cell oncocytoma of the pituitary gland and the first that was immunohistochemically negative for epithelial membrane antigen (EMA) and S100; and the first that displayed haematogenous metastasis to the right sphenoparietal sinus. The three surgical procedures were associated with massive intraoperative bleeding and thus resulted in subtotal tumor resection. Following surgery for the recurrences, the patient underwent radiotherapy.


Subject(s)
Adenoma, Oxyphilic , Pituitary Gland, Posterior , Pituitary Neoplasms , Male , Humans , Middle Aged , Adenoma, Oxyphilic/surgery , Adenoma, Oxyphilic/complications , Adenoma, Oxyphilic/pathology , Pituitary Neoplasms/diagnosis , Pituitary Neoplasms/surgery , Pituitary Neoplasms/complications , Pituitary Gland, Posterior/pathology , Mucin-1 , Recurrence
16.
Br J Neurosurg ; 37(4): 816-824, 2023 Aug.
Article in English | MEDLINE | ID: mdl-31583911

ABSTRACT

We report the case of a 28-year-old female patient who complained of extreme neck pain when giving birth to a child. Magnetic resonance imaging (MRI) of the cervical spine demonstrated an osteolytic lesion at the second cervical vertebral body (C2). In this presentation, we highlight a transoral surgical approach in order to prevent instability of this osteolytic lesion. To the best of our knowledge, this is the first time that such a route of access has been described for this tumor entity. A histopathologic examination led to the diagnosis of epithelioid hemangioendothelioma. During a follow-up period of 33 months, the patient had no complaints.


Subject(s)
Hemangioendothelioma, Epithelioid , Osteolysis , Spinal Neoplasms , Pregnancy , Female , Child , Humans , Adult , Hemangioendothelioma, Epithelioid/diagnostic imaging , Hemangioendothelioma, Epithelioid/surgery , Osteolysis/diagnostic imaging , Osteolysis/etiology , Osteolysis/surgery , Vertebral Body/pathology , Spinal Neoplasms/diagnostic imaging , Spinal Neoplasms/surgery , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Cervical Vertebrae/pathology , Hormones
18.
Invest Radiol ; 58(3): 231-238, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36070523

ABSTRACT

OBJECTIVES: Spectral shaping via tin prefiltration has gained recognition for dose saving in high-contrast imaging tasks. The aim of this phantom dosimetry study was to investigate whether the use of tin filters can also reduce the effective radiation dose in 100 kVp abdominal computed tomography (CT) compared with standard low-dose scans for suspected urolithiasis. METHODS: Using a third-generation dual-source CT scanner, 4 scan protocols each were used on a standard (P1-P4) and a modified obese Alderson-Rando phantom (P5-P8), in which 11 urinary stones of different compositions were placed. Hereby 1 scan protocol represented standard low-dose settings (P1/P5: 110 kVp/120 kVp), whereas 3 experimental protocols used low-kilovoltage spectral shaping (P2/P3/P4 and P6/P7/P8: 100 kVp with tin prefiltration). Radiation dose was recorded by thermoluminescent dosimeters at 24 measurement sites. For objective assessment of image quality, dose-weighted contrast-to-noise ratios were calculated and compared between scan protocols. Additional subjective image quality analysis was performed by 2 radiologists using equidistant 5-point scales for estimation image noise, artifacts, kidney stone detectability, and delineation of bone and soft tissue. RESULTS: Both conventional low-dose protocols without tin prefiltration were associated with the highest individual equivalent doses and the highest effective radiation dose in the experimental setup (P1: 0.29-6.43 mGy, 1.45-1.83 mSv; P5: 0.50-9.35 mGy, 2.33-2.79 mSv). With no false-positive diagnoses, both readers correctly detected each of the 11 urinary calculi irrespective of scan protocol and phantom configuration. Protocols using spectral shaping via tin prefiltration allowed for effective radiation dose reduction of up to 38% on the standard phantom and 18% on the modified obese phantom, while maintaining overall diagnostic image quality. Effective dose was approximately 10% lower in a male versus female anatomy and could be reduced by another 10% if gonadal protection was used ( P < 0.001). CONCLUSIONS: Spectral shaping via tin prefiltration at 100 kVp is a suitable means to reduce the effective radiation dose in abdominal CT imaging of patients with suspected urolithiasis. The dose reduction potential is slightly less pronounced in a modified phantom emulating an obese body composition compared with a standard phantom.


Subject(s)
Tin , Urinary Calculi , Humans , Male , Female , Drug Tapering , Radiation Dosage , Tomography, X-Ray Computed/methods , Urinary Calculi/diagnostic imaging , Phantoms, Imaging
19.
Cancers (Basel) ; 14(18)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36139538

ABSTRACT

BACKGROUND: Polysialic acids (abbr. polySia) are found on numerous tumors, including neuroendocrine lung tumors. They have previously been shown to impact metastatic potential, as they can influence the signaling and adhesion properties of neuronal cell adhesion molecules (abbr. NCAM) and other cell adhesion molecules. Therefore, the aim of this small pilot study was to analyze whether there was a correlation between polySia-NCAM expression and specific clinical or histopathologic characteristics, and if polySia-NCAM expression had an impact on treatment response, disease progression and prognosis of lung neuroendocrine neoplasms. METHODS: This work was based on an analysis of 28 digitized patient records and corresponding patient samples. The response to therapy was radiologically determined at the time of diagnosis and at certain intervals during therapy following the current RECIST1.1 and volumetric sphere calculation. To analyze whether polySia-NCAM expression had prognostic relevance, polySia-NCAM-positive and -negative cases were compared in a Kaplan-Meier survival analysis. FINDINGS: A majority of 78.6% lung neuroendocrine neoplasms showed a strong staining signal for polySia-NCAM. There was a significant correlation between expression and histopathological grade (p = 0.0140), since carcinoids were less likely polySia-NCAM-positive compared to small cell lung carcinoma (abbr. SCLC) and large cell neuroendocrine carcinomas of the lung (abbr. LCNEC). There was no significant association between polySia-NCAM expression and clinical characteristics (age: p = 0.3405; gender: p = 0.6730; smoking history: p = 0.1145; ECOG: p = 0.1756, UICC8 stage: p = 0.1182) or radiologically determined disease progression, regardless of the criteria used to categorize response (RECIST 1.1: p = 0.0759; sphere: p = 0.0580). Furthermore, polySia-NCAM expression did not affect progression-free survival (p = 0.4198) or overall survival (p = 0.6918). INTERPRETATION: PolySia-NCAM expression was more common in high-grade compared to low-grade neuroendocrine neoplasms of the lung; however, this small pilot study failed to show an association between polySia-NCAM expression and response to therapy.

20.
Invest Radiol ; 57(12): 789-801, 2022 12 01.
Article in English | MEDLINE | ID: mdl-35776429

ABSTRACT

OBJECTIVES: Low-dose (LD) computed tomography (CT) is still rarely used in musculoskeletal (MSK) radiology. This study evaluates the potentials of LD CT for follow-up pelvic imaging with special focus on tin filtration (Sn) technology for normal and obese patients with and without metal implants. MATERIALS AND METHODS: In a phantom study, 5 different LD and normal-dose (ND) CT protocols with and without tin filtration were tested using a normal and an obese phantom. Iterative reconstruction (IR) and filtered back projection (FBP) were used for CT image reconstruction. In a subsequent retrospective patient study, ND CT images of 45 patients were compared with follow-up tin-filtered LD CT images with a 90% dose reduction. Sixty-four percent of patients contained metal implants at the follow-up examination. Computed tomography images were objectively (image noise, contrast-to-noise ratio [CNR], dose-normalized contrast-to-noise ratio [CNRD]) and subjectively, using a 6-point Likert score, evaluated. In addition, the figure of merit was calculated. For group comparisons, paired t tests, Wilcoxon signed rank test, analysis of variance, or Kruskal-Wallis tests were used, where applicable. RESULTS: The LD Sn protocol with 67% dose reduction resulted in equal values in qualitative (Likert score) and quantitative image analysis (image noise) compared with the ND protocol in the phantom study. For follow-up examinations, dose could be reduced up to 90% by using Sn LD CT scans without impairment in the clinical study. However, metal implants resulted in a mild impairment of Sn LD as well as ND CT images. Cancellous bone ( P < 0.001) was assessed worse and cortical bone ( P = 0.063) equally in Sn LD CT images compared with ND CT images. Figure of merit values were significant ( P ≤ 0.02) lower and hence better in Sn LD as in ND protocols. Obese patients benefited in particular from tin filtration in LD MSK imaging in terms of image noise and CNR ( P ≤ 0.05). CONCLUSIONS: Low-dose CT scans with tin filtration allow maximum dose reduction while maintaining high image quality for certain clinical purposes, for example, follow-up examinations, especially metal implant position, material loosening, and consolidation controls. Overweight patients benefit particularly from tin filter technology. Although metal implants decrease image quality in ND as well as in Sn LD CT images, this is not a relevant limitation for assessability.


Subject(s)
Drug Tapering , Tin , Humans , Radiation Dosage , Retrospective Studies , Follow-Up Studies , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Pelvis/diagnostic imaging , Obesity , Radiographic Image Interpretation, Computer-Assisted , Algorithms
SELECTION OF CITATIONS
SEARCH DETAIL
...