1.
J Oral Rehabil ; 33(1): 59-63, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16409518

ABSTRACT

Original large-particle composites exhibited poor wear characteristics. With the packable composites, there has been a reintroduction of large particles. The clinical wear characteristics of such packable composites are relatively unknown. The purpose of this study was to compare wear between two types of packable composites: Alert (Jeneric Pentron) and Surefil (Dentsply Caulk). Each material was compared with and without a surface sealant. Fifty-two subjects were included. Subjects had to have two to four eligible teeth, be 21 years of age, in good health and in need of moderate to large class 2 restorations on molars, and/or a two-surface class 1 on molars. Wear was assessed, using the Moffa-Lugassy (ML) scale, by evaluating stone models made from polyvinyl siloxane (PVS) impressions taken at baseline and 6 months. Rating was done by four calibrated examiners using a forced consensus model. The use of a surface sealant with Alert significantly reduced the median wear rate at 6 months compared with that of the SureFil restorations.


Subject(s)
Composite Resins/chemistry , Dental Restoration Wear , Dental Restoration, Permanent/methods , Pit and Fissure Sealants/chemistry , Adult , Humans , Materials Testing/methods , Molar
2.
Oper Dent ; 27(6): 593-9, 2002.
Article in English | MEDLINE | ID: mdl-12413225

ABSTRACT

This study investigated the extent of cure (monomer conversion into polymer) of a variety of photo-initiated resin composites and different shades. Cure values were measured at the top surface and at simulated lighting conditions 0.5, 1.0 and 2.0 mm below the top. The exposure methods used were continuous output at 600 mW/cm2 (10, 20 or 40 seconds), initial component of the pulse-delay technique (pulse) (3 seconds at 200 mW/cm2) and the entire pulse-delay technique (pulse, 3-minute delay, 10 seconds at 600 mW/cm2). The results showed very little difference in conversion values between A2 and D2 shades of the same composite with respect to depth. Conversion values using only the pulse method were remarkably low at the top surface and diminished rapidly at depths. Conversion using the pulse-delay technique produced similar values as that of the continuous 10-second exposure at similar depths but still decreased remarkably at depth. Conversion values using the pulse-delay technique and a 20-second continuous exposure were significantly lower than those obtained using continuous 40-second exposure.


Subject(s)
Composite Resins/radiation effects , Technology, Dental/methods , Analysis of Variance , Color , Light , Methacrylates/radiation effects , Polymers/chemistry , Resin Cements/radiation effects , Silicon Dioxide/radiation effects , Zirconium/radiation effects