Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Nat Commun ; 13(1): 7743, 2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36522338

ABSTRACT

The second Venus flyby of the BepiColombo mission offer a unique opportunity to make a complete tour of one of the few gas-dynamics dominated interaction regions between the supersonic solar wind and a Solar System object. The spacecraft pass through the full Venusian magnetosheath following the plasma streamlines, and cross the subsolar stagnation region during very stable solar wind conditions as observed upstream by the neighboring Solar Orbiter mission. These rare multipoint synergistic observations and stable conditions experimentally confirm what was previously predicted for the barely-explored stagnation region close to solar minimum. Here, we show that this region has a large extend, up to an altitude of 1900 km, and the estimated low energy transfer near the subsolar point confirm that the atmosphere of Venus, despite being non-magnetized and less conductive due to lower ultraviolet flux at solar minimum, is capable of withstanding the solar wind under low dynamic pressure.

2.
BMC Nurs ; 21(1): 55, 2022 Mar 07.
Article in English | MEDLINE | ID: mdl-35255923

ABSTRACT

BACKGROUND: The clinical teaching is the core component of the nursing curriculum, the alarming pandemic rates brought uncertainty to clinical teaching, weighing the safety of patients, students, and faculty, which demanded essential modification in clinical teaching and resulted in challenges in relation to effective response to clinical teaching requirements. This study aimed to assess the effective clinical teaching from the nurse educators' perspective during the remote teaching that followed the COVID-19 pandemic. METHODS: This study is a national Web-based descriptive study. Participants were recruited from five major Nursing Colleges in Oman. Descriptive and inferential as well as multiple linear regression analyses were conducted. RESULTS: A total of 127 nurse educators completed the survey with mean age of 43.9 (SD = 6.9) years. The overall effective clinical teaching score was 54.4 (SD = 10.9) which is considered acceptable, although the nurse educators in Oman reported the highest score on the safety dimension of the effective clinical teaching. Furthermore, females, doctoral prepared nurse educators, and those who acted as preceptors reported higher effective clinical teaching levels compared to their counterparts. The regression analysis showed that age, gender, and attending infection control training are significant predictors of effective clinical teaching. CONCLUSION: The paradigm shift in clinical teaching requires adequate measures including identification and appropriate training of clinical instructors and preceptors to meet clinical teaching demands in remote teaching. It is also important to take actions that promote and maintain the safety prioritization in bedside clinical teaching. These measures might positively impact on the nursing education process.

3.
Sci Rep ; 10(1): 7932, 2020 May 13.
Article in English | MEDLINE | ID: mdl-32404966

ABSTRACT

Cassini's Grand Finale orbits provided for the first time in-situ measurements of Saturn's topside ionosphere. We present the Pedersen and Hall conductivities of the top near-equatorial dayside ionosphere, derived from the in-situ measurements by the Cassini Radio and Wave Plasma Science Langmuir Probe, the Ion and Neutral Mass Spectrometer and the fluxgate magnetometer. The Pedersen and Hall conductivities are constrained to at least 10-5-10-4 S/m at (or close to) the ionospheric peak, a factor 10-100 higher than estimated previously. We show that this is due to the presence of dusty plasma in the near-equatorial ionosphere. We also show the conductive ionospheric region to be extensive, with thickness of 300-800 km. Furthermore, our results suggest a temporal variation (decrease) of the plasma densities, mean ion masses and consequently the conductivities from orbit 288 to 292.

4.
Phys Rev Lett ; 123(24): 245101, 2019 Dec 13.
Article in English | MEDLINE | ID: mdl-31922873

ABSTRACT

The first complete estimation of the compressible energy cascade rate |ϵ_{C}| at magnetohydrodynamic (MHD) and subion scales is obtained in Earth's magnetosheath using Magnetospheric MultiScale spacecraft data and an exact law derived recently for compressible Hall MHD turbulence. A multispacecraft technique is used to compute the velocity and magnetic gradients, and then all the correlation functions involved in the exact relation. It is shown that when the density fluctuations are relatively small, |ϵ_{C}| identifies well with its incompressible analog |ϵ_{I}| at MHD scales but becomes much larger than |ϵ_{I}| at subion scales. For larger density fluctuations, |ϵ_{C}| is larger than |ϵ_{I}| at every scale with a value significantly higher than for smaller density fluctuations. Our study reveals also that for both small and large density fluctuations, the nonflux terms remain always negligible with respect to the flux terms and that the major contribution to |ϵ_{C}| at subion scales comes from the compressible Hall flux.

5.
Science ; 362(6410)2018 10 05.
Article in English | MEDLINE | ID: mdl-30287633

ABSTRACT

The sizes of Saturn's ring particles range from meters (boulders) to nanometers (dust). Determination of the rings' ages depends on loss processes, including the transport of dust into Saturn's atmosphere. During the Grand Finale orbits of the Cassini spacecraft, its instruments measured tiny dust grains that compose the innermost D-ring of Saturn. The nanometer-sized dust experiences collisions with exospheric (upper atmosphere) hydrogen and molecular hydrogen, which forces it to fall from the ring into the ionosphere and lower atmosphere. We used the Magnetospheric Imaging Instrument to detect and characterize this dust transport and also found that diffusion dominates above and near the altitude of peak ionospheric density. This mechanism results in a mass deposition into the equatorial atmosphere of ~5 kilograms per second, constraining the age of the D-ring.

6.
Science ; 362(6410)2018 10 05.
Article in English | MEDLINE | ID: mdl-30287634

ABSTRACT

The Pioneer and Voyager spacecraft made close-up measurements of Saturn's ionosphere and upper atmosphere in the 1970s and 1980s that suggested a chemical interaction between the rings and atmosphere. Exploring this interaction provides information on ring composition and the influence on Saturn's atmosphere from infalling material. The Cassini Ion Neutral Mass Spectrometer sampled in situ the region between the D ring and Saturn during the spacecraft's Grand Finale phase. We used these measurements to characterize the atmospheric structure and material influx from the rings. The atmospheric He/H2 ratio is 10 to 16%. Volatile compounds from the rings (methane; carbon monoxide and/or molecular nitrogen), as well as larger organic-bearing grains, are flowing inward at a rate of 4800 to 45,000 kilograms per second.

7.
Phys Rev Lett ; 120(5): 055102, 2018 Feb 02.
Article in English | MEDLINE | ID: mdl-29481187

ABSTRACT

The first estimation of the energy cascade rate |ε_{C}| of magnetosheath turbulence is obtained using the Cluster and THEMIS spacecraft data and an exact law of compressible isothermal magnetohydrodynamics turbulence. The mean value of |ε_{C}| is found to be close to 10^{-13} J m^{-3} s^{-1}, at least 2 orders of magnitude larger than its value in the solar wind (∼10^{-16} J m^{-3} s^{-1} in the fast wind). Two types of turbulence are evidenced and shown to be dominated either by incompressible Alfvénic or compressible magnetosoniclike fluctuations. Density fluctuations are shown to amplify the cascade rate and its spatial anisotropy in comparison with incompressible Alfvénic turbulence. Furthermore, for compressible magnetosonic fluctuations, large cascade rates are found to lie mostly near the linear kinetic instability of the mirror mode. New empirical power-laws relating |ε_{C}| to the turbulent Mach number and to the internal energy are evidenced. These new findings have potential applications in distant astrophysical plasmas that are not accessible to in situ measurements.

8.
Science ; 359(6371): 66-68, 2018 01 05.
Article in English | MEDLINE | ID: mdl-29229651

ABSTRACT

The ionized upper layer of Saturn's atmosphere, its ionosphere, provides a closure of currents mediated by the magnetic field to other electrically charged regions (for example, rings) and hosts ion-molecule chemistry. In 2017, the Cassini spacecraft passed inside the planet's rings, allowing in situ measurements of the ionosphere. The Radio and Plasma Wave Science instrument detected a cold, dense, and dynamic ionosphere at Saturn that interacts with the rings. Plasma densities reached up to 1000 cubic centimeters, and electron temperatures were below 1160 kelvin near closest approach. The density varied between orbits by up to two orders of magnitude. Saturn's A- and B-rings cast a shadow on the planet that reduced ionization in the upper atmosphere, causing a north-south asymmetry.

9.
Med Phys ; 42(7): 4211-26, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26133620

ABSTRACT

PURPOSE: To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. RESULTS: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. CONCLUSIONS: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.


Subject(s)
Film Dosimetry/instrumentation , Film Dosimetry/methods , Algorithms , Calibration , Radiation Dosage , Skin/radiation effects , Uncertainty , X-Rays
10.
Phys Med Biol ; 55(13): 3631-41, 2010 Jul 07.
Article in English | MEDLINE | ID: mdl-20526035

ABSTRACT

The emission of radiation from a contaminated body region is connected with the dose received by radiosensitive tissue through the specific absorbed fractions (SAFs) of emitted energy, which is therefore an essential quantity for internal dose assessment. A set of SAFs were calculated using the new adult reference computational phantoms, released by the International Commission on Radiological Protection (ICRP) together with the International Commission on Radiation Units and Measurements (ICRU). Part of these results has been recently published in ICRP Publication 110 (2009 Adult reference computational phantoms (Oxford: Elsevier)). In this paper, we mainly discuss the results and also present them in numeric form. The emission of monoenergetic photons and electrons with energies ranging from 10 keV to 10 MeV was simulated for three source organs: lungs, thyroid and liver. SAFs were calculated for four target regions in the body: lungs, colon wall, breasts and stomach wall. For quality assurance purposes, the simulations were performed simultaneously at the Helmholtz Zentrum München (HMGU, Germany) and at the Institute for Radiological Protection and Nuclear Safety (IRSN, France), using the Monte Carlo transport codes EGSnrc and MCNPX, respectively. The comparison of results shows overall agreement for photons and high-energy electrons with differences lower than 8%. Nevertheless, significant differences were found for electrons at lower energy for distant source/target organ pairs. Finally, the results for photons were compared to the SAF values derived using mathematical phantoms. Significant variations that can amount to 200% were found. The main reason for these differences is the change of geometry in the more realistic voxel body models. For electrons, no SAFs have been computed with the mathematical phantoms; instead, approximate formulae have been used by both the Medical Internal Radiation Dose committee (MIRD) and the ICRP due to the limitations imposed by the computing power available at this time. These approximations are mainly based on the assumption that electrons are absorbed locally in the source organ itself. When electron SAFs are calculated explicitly, discrepancies with this simplifying assumption are notable, especially at high energies and for neighboring organs where the differences can reach the same order of magnitude as for photon SAFs.


Subject(s)
Computer Simulation , Models, Biological , Phantoms, Imaging , Radiometry/instrumentation , Radiometry/methods , Adult , Breast/radiation effects , Colon/radiation effects , Electrons , Female , Humans , Liver/radiation effects , Lung/radiation effects , Monte Carlo Method , Photons , Quality Assurance, Health Care , Radiation Dosage , Sex Characteristics , Stomach/radiation effects , Thyroid Gland/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL
...