Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Otol Rhinol Laryngol ; 123(2): 135-40, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24574469

ABSTRACT

OBJECTIVES: We developed a large animal model for auricular reconstruction with engineered cartilage frameworks and evaluated the performance of porous polyethylene auricular implants in this model. METHODS: Eighteen high-density porous polyethylene auricular frameworks were implanted subcutaneously in the infra-auricular areas of 9 sheep. The implants were harvested 17 weeks later for gross and histologic examination. The perioperative and postoperative courses were carefully documented. RESULTS: Five implants became exposed, and 2 implants needed to be removed at 7 weeks. Additionally, 1 infected implant was removed at 2 weeks. Seromas developed in 2 implants because of drain failures and were drained successfully during the first postoperative week. There were no other surgical site complications. The remaining 10 implants had an acceptable cosmetic appearance at 17 weeks. CONCLUSIONS: The perioperative complication rate in the ovine porous polyethylene auricular implant model was higher than that reported for auricular reconstructions in humans. The implant exposures were likely caused by ischemia and excessive stress on the thin overlying skin, because vascularized flap coverage was not used. The histologic findings were comparable to the results reported for other animal models. This large animal model is appropriate for auricular reconstruction experiments, including engineered constructs.


Subject(s)
Ear Auricle/surgery , Ear Cartilage/surgery , Models, Animal , Polyethylene , Tissue Engineering , Tissue Scaffolds , Animals , Female , Male , Porosity , Plastic Surgery Procedures , Sheep
2.
J R Soc Interface ; 10(87): 20130413, 2013 Oct 06.
Article in English | MEDLINE | ID: mdl-23904585

ABSTRACT

Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation. Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure in situ. Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs.


Subject(s)
Ear/anatomy & histology , Tissue Engineering/methods , Tissue Scaffolds , Animals , Cartilage , Prostheses and Implants , Rats , Surface Properties , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...