1.
J Dermatol Surg Oncol
; 12(7): 730-3, 1986 Jul.
Article
in English
| MEDLINE
| ID: mdl-3722584
ABSTRACT
We have reviewed modifications in scalp reduction instrumentation that have enabled the physicians of the group to substantially reduce patient discomfort and operative time. Simultaneously, we are assured that the risk of errors relative to the optimal size of the excisions, correct plane of undermining, and the possibility of excessive blood loss are minimized. The incorporation of this instrumentation has reduced the average scalp reduction procedure time, in our hands, from 70 to 35 minutes without increasing the complication rate.