Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 25(5): e14299, 2024 May.
Article in English | MEDLINE | ID: mdl-38520072

ABSTRACT

A new generation cone-beam computed tomography (CBCT) system with new hardware design and advanced image reconstruction algorithms is available for radiation treatment simulation or adaptive radiotherapy (HyperSight CBCT imaging solution, Varian Medical Systems-a Siemens Healthineers company). This study assesses the CBCT image quality metrics using the criteria routinely used for diagnostic CT scanner accreditation as a first step towards the future use of HyperSight CBCT images for treatment planning and target/organ delineations. Image performance was evaluated using American College of Radiology (ACR) Program accreditation phantom tests for diagnostic computed tomography systems (CTs) and compared HyperSight images with a standard treatment planning diagnostic CT scanner (Siemens SOMATOM Edge) and with existing CBCT systems (Varian TrueBeam version 2.7 and Varian Halcyon version 2.0).  Image quality performance for all Varian HyperSight CBCT vendor-provided imaging protocols were assessed using ACR head and body ring CT phantoms, then compared to existing imaging modalities. Image quality analysis metrics included contrast-to-noise (CNR), spatial resolution, Hounsfield number (HU) accuracy, image scaling, and uniformity. All image quality assessments were made following the recommendations and passing criteria provided by the ACR. The Varian HyperSight CBCT imaging system demonstrated excellent image quality, with the majority of vendor-provided imaging protocols capable of passing all ACR CT accreditation standards. Nearly all (8/11) vendor-provided protocols passed ACR criteria using the ACR head phantom, with the Abdomen Large, Pelvis Large, and H&N vendor-provided protocols produced HU uniformity values slightly exceeding passing criteria but remained within the allowable minor deviation levels (5-7 HU maximum differences). Compared to other existing CT and CBCT imaging modalities, both HyperSight Head and Pelvis imaging protocols matched the performance of the SOMATOM CT scanner, and both the HyperSight and SOMATOM CT substantially surpassed the performance of the Halcyon 2.0 and TrueBeam version 2.7 systems. Varian HyperSight CBCT imaging system could pass almost all tests for all vendor-provided protocols using ACR accreditation criteria, with image quality similar to those produced by diagnostic CT scanners and significantly better than existing linac-based CBCT imaging systems.


Subject(s)
Benchmarking , Cone-Beam Computed Tomography , Image Processing, Computer-Assisted , Particle Accelerators , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted , Humans , Cone-Beam Computed Tomography/methods , Cone-Beam Computed Tomography/instrumentation , Particle Accelerators/instrumentation , Image Processing, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Accreditation , Radiographic Image Interpretation, Computer-Assisted/methods
2.
Adv Radiat Oncol ; 9(3): 101385, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38495035

ABSTRACT

Purpose: Our purpose was to report complications requiring surgical intervention among patients treated with postmastectomy proton radiation therapy (PMPRT) for breast cancer in the setting of breast reconstruction (BR). Methods and Materials: Patients enrolled on a prospective proton registry who underwent BR with immediate autologous flap, tissue expander (TE), or implant in place during PMPRT (50/50.4 Gy +/- chest wall boost) were eligible. Major reconstruction complication (MRC) was defined as a complication requiring surgical intervention. Absolute reconstruction failure was an MRC requiring surgical removal of BR. A routine revision (RR) was a plastic surgery refining cosmesis of the BR. Kaplan-Meier method was used to assess disease outcomes and MRC. Cox regression was used to assess predictors of MRC. Results: Seventy-three courses of PMPRT were delivered to 68 women with BR between 2013 and 2021. Median follow-up was 42.1 months. Median age was 47 years. Fifty-six (76.7%) courses used pencil beam scanning PMPRT. Of 73 BR, 29 were flaps (39.7%), 30 implants (41.1%), and 14 TE (19.2%) at time of irradiation. There were 20 (27.4%) RR. There were 9 (12.3%) MRC among 5 implants, 2 flaps, and 2 TE, occurring a median of 29 months from PMPRT start. Three-year freedom from MRC was 86.9%. Three (4.1%) of the MRC were absolute reconstruction failure. Complications leading to MRC included capsular contracture in 5, fat necrosis in 2, and infection in 2. On univariable analysis, BR type, boost, proton technique, age, and smoking status were not associated with MRC, whereas higher body mass index trended toward significance (hazard ratio, 1.07; 95% CI, 0.99-1.16; P = .10). Conclusions: Patients undergoing PMPRT to BR had a 12.3% incidence of major complications leading to surgical intervention, and total loss of BR was rare. MRC rates were similar among reconstruction types. Minor surgery for RR is common in our practice.

3.
AI (Basel) ; 4(4): 875-887, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37929255

ABSTRACT

With the 2019 coronavirus disease (COVID-19) pandemic, there is an increasing demand for remote monitoring technologies to reduce patient and provider exposure. One field that has an increasing potential is teleguided ultrasound, where telemedicine and point-of-care ultrasound (POCUS) merge to create this new scope. Teleguided POCUS can minimize staff exposure while preserving patient safety and oversight during bedside procedures. In this paper, we propose the use of teleguided POCUS supported by AI technologies for the remote monitoring of COVID-19 patients by non-experienced personnel including self-monitoring by the patients themselves. Our hypothesis is that AI technologies can facilitate the remote monitoring of COVID-19 patients through the utilization of POCUS devices, even when operated by individuals without formal medical training. In pursuit of this goal, we performed a pilot analysis to evaluate the performance of users with different clinical backgrounds using a computer-based system for COVID-19 detection using lung ultrasound. The purpose of the analysis was to emphasize the potential of the proposed AI technology for improving diagnostic performance, especially for users with less experience.

4.
Article in English | MEDLINE | ID: mdl-37101538

ABSTRACT

The emergence of the Halcyon linear accelerator has allowed for increased patient throughput and improved treatment times for common treatment sites in radiation oncology. However, it has been shown that this can lead to increased surface dose in sites like breast cancer compared with treatments on conventional machines with flattened radiation beams. Cherenkov imaging can be used to estimate surface dose by detection of Cherenkov photons emitted in proportion to energy deposition from high energy electrons in tissue. Phantom studies were performed with both square beams in reference conditions and with clinical treatments, and dosimeter readings and Cherenkov images report higher surface dose (25% for flat phantom entrance dose, 5.9% for breast phantom treatment) from Halcyon beam deliveries than for equivalent deliveries from a TrueBeam linac. Additionally, the first Cherenkov images of a patient treated with Halcyon were acquired, and superficial dose was estimated.

5.
Cancers (Basel) ; 13(16)2021 Aug 23.
Article in English | MEDLINE | ID: mdl-34439398

ABSTRACT

Ultra-high dose rate FLASH proton radiotherapy (F-PRT) has been shown to reduce normal tissue toxicity compared to standard dose rate proton radiotherapy (S-PRT) in experiments using the entrance portion of the proton depth dose profile, while proton therapy uses a spread-out Bragg peak (SOBP) with unknown effects on FLASH toxicity sparing. To investigate, the biological effects of F-PRT using an SOBP and the entrance region were compared to S-PRT in mouse intestine. In this study, 8-10-week-old C57BL/6J mice underwent 15 Gy (absorbed dose) whole abdomen irradiation in four groups: (1) SOBP F-PRT, (2) SOBP S-PRT, (3) entrance F-PRT, and (4) entrance S-PRT. Mice were injected with EdU 3.5 days after irradiation, and jejunum segments were harvested and preserved. EdU-positive proliferating cells and regenerated intestinal crypts were quantified. The SOBP had a modulation (width) of 2.5 cm from the proximal to distal 90%. Dose rates with a SOBP for F-PRT or S-PRT were 108.2 ± 8.3 Gy/s or 0.82 ± 0.14 Gy/s, respectively. In the entrance region, dose rates were 107.1 ± 15.2 Gy/s and 0.83 ± 0.19 Gy/s, respectively. Both entrance and SOBP F-PRT preserved a significantly higher number of EdU + /crypt cells and percentage of regenerated crypts compared to S-PRT. Moreover, tumor growth studies showed no difference between SOBP and entrance for either of the treatment modalities.

6.
J Phys Condens Matter ; 30(40): 405804, 2018 Oct 10.
Article in English | MEDLINE | ID: mdl-30168452

ABSTRACT

The observation of inverted magnetic hysteresis loops and negative magnetic remanence (NRM) in a 7.6 nm thin film of La0.7Sr0.3MnO3 grown on SrTiO3 substrates is reported. The film was grown employing pulsed laser deposition and characterized by reflection high-energy electron diffraction during growth and using x-ray reflectivity measurements post-growth. Magnetic properties of the film were measured from 5 K to 400 K under both the field-cooled (FC) and zero-field-cooled (ZFC) conditions. The observed results of inverted magnetic hysteresis loops and NRM are interpreted in terms of the co-existence of a magnetically inhomogeneous region consisting of superparamagnetic spin clusters with a blocking temperature T B = 240 K and the ferromagnetic state with an ordering temperature T C = 290 K. Hysteresis loop inversion is observed in the temperature region of T B < T < T C whereas NRM appears in the mixed superparamagnetic and ferromagnetic states for T < T C down to 5 K. These observations of hysteresis loop inversion and NRM are related to the magneto-static interaction between the superparamagnetic and ferromagnetic phases leading to anti-alignment of spin of both magnetic phases with respect to each other.

SELECTION OF CITATIONS
SEARCH DETAIL
...