Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Digit J Ophthalmol ; 17(3): 40-2, 2011.
Article in English | MEDLINE | ID: mdl-23362394

ABSTRACT

A 26-year-old-man who had suffered a severe electrical injury 3 years previously presented with blurred vision in his left eye caused by a posterior subcapsular cataract with nuclear sclerotic changes and peripapillary chorioretinal scarring. The pattern of retinal atrophy surrounding the optic nerve suggests a possible path of electrical current to the eye and demonstrates the selective tissuedamage that may occur in electrical injuries.

2.
Ophthalmology ; 113(10): 1724-33, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17011954

ABSTRACT

PURPOSE: To compare the success of pars plana vitrectomy (PPV) versus scleral buckle (SB) in the management of uncomplicated pseudophakic retinal detachments (RDs). DESIGN: Meta-analysis of published studies from 1966 to 2004 regarding surgical treatment of pseudophakic RDs. PARTICIPANTS: Two thousand two hundred thirty eyes: 1579 operated by SB, 457 by PPV, and 194 by the combined method of PPV and SB. METHODS: We compared reattachment and functional success rates after 3 commonly practiced surgical interventions for pseudophakic RDs: PPV, SB, and the combined method. Twelve hundred thirty-two articles were retrieved from Medline and by cross-reference searches. Articles with sufficient data on preoperative evaluation, applied surgical technique, and anatomical and functional success rates were included in this analysis. Articles regarding complex pseudophakic RDs, treatment by laser or pneumatic retinopexy, studies with indistinguishable treatment outcomes from phakic and pseudophakic RDs, or reviews without original data were excluded. MAIN OUTCOME MEASURES: Anatomical success rates after initial surgical intervention and after reoperation(s) for primary failures, and best or final visual outcome at the end of follow-up. RESULTS: Of 1232 papers, 29 matched inclusion criteria. After controlling for variation between study characteristics, PPV and the combined method resulted in higher initial reattachment rates (odds ratio [OR], 1.69; 95% confidence interval [CI], 1.07-2.68, and OR, 3.54; 95% CI, 1.57-7.97, respectively) as compared with SB. The differences between the procedures persisted for final reattachment outcome despite reoperation for primary failures. Final visual outcome also was found to depend on the choice of primary surgical intervention. After controlling for differences in the study characteristics, the probability of visual improvement was higher after PPV (OR, 2.34; 95% CI, 1.58-3.46) or the combined method (OR, 11.52; 95% CI, 4.42-30.04) as compared with SB. CONCLUSIONS: A meta-analysis of published literature implies that PPV with or without SB is more likely to achieve a favorable anatomical and visual outcome than conventional SB alone in uncomplicated pseudophakic RDs. However, the inherent limitations of differing study protocols, quality of included studies, and publication bias in a pooled analysis should be recognized.


Subject(s)
Pseudophakia/surgery , Retinal Detachment/surgery , Scleral Buckling/methods , Vitrectomy/methods , Aged , Humans , Lens Implantation, Intraocular/adverse effects , Middle Aged , Prospective Studies , Pseudophakia/etiology , Pseudophakia/physiopathology , Reoperation , Retina/physiopathology , Retinal Detachment/etiology , Retinal Detachment/physiopathology , Retrospective Studies , Treatment Outcome , Visual Acuity/physiology
3.
Am J Ophthalmol ; 138(1): 146-7, 2004 Jul.
Article in English | MEDLINE | ID: mdl-15234299

ABSTRACT

PURPOSE: To report a case of large bilateral intraocular foreign bodies mistaken for crystalline lens on computed tomography (CT). DESIGN: Case report. METHODS: A 24-year-old man was referred after bilateral open globe repair following a motor vehicle accident. Preoperatively, the CT scan had been read as "Right eye posteriorly dislocated lens. No evidence of foreign bodies." RESULTS: The patient underwent left eye cataract extraction with removal of a 7 x 5 x 5 mm piece of glass buried in the crystalline lens. The patient subsequently underwent right eye pars plana vitrectomy, removal of another piece of glass measuring 6 x 5 x 5 mm, retinal detachment surgery, and corneal grafting. CONCLUSIONS: Current safety standards require auto glass to fracture into pieces of a specific size to minimize laceration and missile injury. These pieces of glass may have a shape and size similar to the crystalline lens but have higher radiodensity on CT scan.


Subject(s)
Corneal Injuries , Eye Foreign Bodies/diagnostic imaging , Eye Injuries, Penetrating/diagnostic imaging , Glass , Lens Subluxation/diagnostic imaging , Accidents, Traffic , Adult , Cataract Extraction , Corneal Transplantation , Diagnosis, Differential , Eye Foreign Bodies/surgery , Eye Injuries, Penetrating/surgery , Humans , Lens Subluxation/surgery , Lens, Crystalline/injuries , Male , Retina/injuries , Retinal Detachment/surgery , Tomography, X-Ray Computed , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL
...