1.
Phys Med Biol ; 69(10)2024 May 07.
Article in English | MEDLINE | ID: mdl-38631365

ABSTRACT

Objective.To report on a micro computed tomography (micro-CT) system capable of x-ray phase contrast imaging and of increasing spatial resolution at constant magnification.Approach.The micro-CT system implements the edge illumination (EI) method, which relies on two absorbing masks with periodically spaced transmitting apertures in the beam path; these split the beam into an array of beamlets and provide sensitivity to the beamlets' directionality, i.e. refraction. In EI, spatial resolution depends on the width of the beamlets rather than on the source/detector point spread function (PSF), meaning that resolution can be increased by decreasing the mask apertures, without changing the source/detector PSF or the magnification.Main results.We have designed a dedicated mask featuring multiple bands with differently sized apertures and used this to demonstrate that resolution is a tuneable parameter in our system, by showing that increasingly small apertures deliver increasingly detailed images. Phase contrast images of a bar pattern-based resolution phantom and a biological sample (a mouse embryo) were obtained at multiple resolutions.Significance.The new micro-CT system could find application in areas where phase contrast is already known to provide superior image quality, while the added tuneable resolution functionality could enable more sophisticated analyses in these applications, e.g. by scanning samples at multiple scales.


Subject(s)
Phantoms, Imaging , X-Ray Microtomography , X-Ray Microtomography/instrumentation , Mice , Animals , Embryo, Mammalian/diagnostic imaging , Image Processing, Computer-Assisted/methods
2.
Optica ; 10(7): 880-887, 2023 Jul 20.
Article in English | MEDLINE | ID: mdl-37841216

ABSTRACT

X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phase-contrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues. We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against known-material phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart. We believe that the simplicity of the setup we are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.

3.
Phys Med Biol ; 68(9)2023 04 24.
Article in English | MEDLINE | ID: mdl-36996845

ABSTRACT

Objective.Attenuation masks can be used in x-ray imaging systems to increase their inherent spatial resolution and/or make them sensitive to phase effects, a typical example being Edge Illumination x-ray phase contrast imaging (EI-XPCI). This work investigates the performance of a mask-based system such as EI-XPCI in terms of Modulation Transfer Function (MTF), in the absence of phase effects.Approach. Pre-sampled MTF measurements, using an edge, were performed on the same system implemented without masks, with non-skipped masks and finally with skipped masks (i.e. masks in which apertures illuminate every other pixel row/column). Results are compared to simulations and finally images of a resolution bar pattern acquired with all the above setups are presented.Main results. Compared to the detector's inherent MTF, the non-skipped mask setup provides improved MTF results. In comparison to an ideal case where signal spill-out into neighbouring pixels is negligible, this improvement takes place only at specific frequencies of the MTF, dictated by the spatial repetition of the spill-out signal. This is limited with skipped masks, which indeed provide further MTF improvements over a larger frequency range. Experimental MTF measurements are supported through simulation and resolution bar pattern images.Significance. This work has quantified the improvement in MTF due to the use of attenuation masks and lays the foundation for how acceptance and routine quality control tests will have to be modified when systems using masks are introduced in clinical practice and how MTF results will compare to those of conventional imaging systems.


Subject(s)
Radiographic Image Enhancement , Radiographic Image Interpretation, Computer-Assisted , X-Rays , Radiographic Image Enhancement/methods , Computer Simulation , Radiographic Image Interpretation, Computer-Assisted/methods , Quality Control , Phantoms, Imaging
5.
Opt Express ; 30(24): 43209-43222, 2022 Nov 21.
Article in English | MEDLINE | ID: mdl-36523024

ABSTRACT

Cycloidal computed tomography provides high-resolution images within relatively short scan times by combining beam modulation with dedicated under-sampling. However, implementing the technique relies on accurate knowledge of the sample's motion, particularly in the case of continuous scans, which is often unavailable due to hardware or software limitations. We have developed an easy-to-implement position tracking technique using a sharp edge, which can provide reliable information about the trajectory of the sample and thus improve the reconstruction process. Furthermore, this approach also enables the development of other innovative sampling schemes, which may otherwise be difficult to implement.

6.
Acta Biomater ; 141: 290-299, 2022 03 15.
Article in English | MEDLINE | ID: mdl-35051630

ABSTRACT

Tissue engineering (TE) aims to generate bioengineered constructs which can offer a surgical treatment for many conditions involving tissue or organ loss. Construct generation must be guided by suitable assessment tools. However, most current tools (e.g. histology) are destructive, which restricts evaluation to a single-2D anatomical plane, and has no potential for assessing constructs prior to or following their implantation. An alternative can be provided by laboratory-based x-ray phase contrast computed tomography (PC-CT), which enables the extraction of 3D density maps of an organ's anatomy. In this work, we developed a semi-automated image processing pipeline dedicated to the analysis of PC-CT slices of oesophageal constructs. Visual and quantitative (density and morphological) information is extracted on a volumetric basis, enabling a comprehensive evaluation of the regenerated constructs. We believe the presented tools can enable the successful regeneration of patient-specific oesophagus, and bring comparable benefit to a wide range of TE applications. STATEMENT OF SIGNIFICANCE: Phase contrast computed tomography (PC-CT) is an imaging modality which generates high resolution volumetric density maps of biological tissue. In this work, we demonstrate the use of PC-CT as a new tool for guiding the progression of an oesophageal tissue engineering (TE) protocol. Specifically, we developed a semi-automated image-processing pipeline which analyses the oesophageal PC-CT slices, extracting visual and quantitative (density and morphological) information. This information was proven key for performing a comprehensive evaluation of the regenerated constructs, and cannot be obtained through existing assessment tools primarily due to their destructive nature (e.g. histology). This work paves the way for using PC-CT in a wide range of TE applications which can be pivotal for unlocking the potential of this field.


Subject(s)
Tissue Engineering , Tomography, X-Ray Computed , Humans , Image Processing, Computer-Assisted , Microscopy, Phase-Contrast , Tissue Engineering/methods , Tomography, X-Ray Computed/methods , X-Rays
7.
Sci Rep ; 12(1): 893, 2022 01 18.
Article in English | MEDLINE | ID: mdl-35042961

ABSTRACT

In x-ray computed tomography (CT), the achievable image resolution is typically limited by several pre-fixed characteristics of the x-ray source and detector. Structuring the x-ray beam using a mask with alternating opaque and transmitting septa can overcome this limit. However, the use of a mask imposes an undersampling problem: to obtain complete datasets, significant lateral sample stepping is needed in addition to the sample rotation, resulting in high x-ray doses and long acquisition times. Cycloidal CT, an alternative scanning scheme by which the sample is rotated and translated simultaneously, can provide high aperture-driven resolution without sample stepping, resulting in a lower radiation dose and faster scans. However, cycloidal sinograms are incomplete and must be restored before tomographic images can be computed. In this work, we demonstrate that high-quality images can be reconstructed by applying the recently proposed Mixed Scale Dense (MS-D) convolutional neural network (CNN) to this task. We also propose a novel training approach by which training data are acquired as part of each scan, thus removing the need for large sets of pre-existing reference data, the acquisition of which is often not practicable or possible. We present results for both simulated datasets and real-world data, showing that the combination of cycloidal CT and machine learning-based data recovery can lead to accurate high-resolution images at a limited dose.

8.
IEEE Trans Med Imaging ; 41(5): 1188-1195, 2022 05.
Article in English | MEDLINE | ID: mdl-34941505

ABSTRACT

The assessment of margin involvement is a fundamental task in breast conserving surgery to prevent recurrences and reoperations. It is usually performed through histology, which makes the process time consuming and can prevent the complete volumetric analysis of large specimens. X-ray phase contrast tomography combines high resolution, sufficient penetration depth and high soft tissue contrast, and can therefore provide a potential solution to this problem. In this work, we used a high-resolution implementation of the edge illumination X-ray phase contrast tomography based on "pixel-skipping" X-ray masks and sample dithering, to provide high definition virtual slices of breast specimens. The scanner was originally designed for intra-operative applications in which short scanning times were prioritised over spatial resolution; however, thanks to the versatility of edge illumination, high-resolution capabilities can be obtained with the same system simply by swapping x-ray masks without this imposing a reduction in the available field of view. This makes possible an improved visibility of fine tissue strands, enabling a direct comparison of selected CT slices with histology, and providing a tool to identify suspect features in large specimens before slicing. Combined with our previous results on fast specimen scanning, this works paves the way for the design of a multi-resolution EI scanner providing intra-operative capabilities as well as serving as a digital pathology system.


Subject(s)
Histological Techniques , Lighting , Microscopy, Phase-Contrast/methods , Radiography , X-Rays
9.
Med Phys ; 48(10): 5884-5896, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34387879

ABSTRACT

PURPOSE: In this work, an analytical model describing the noise in the retrieved three contrast channels, transmission, refraction, and ultra small-angle scattering, obtained with edge illumination X-ray phase-based imaging system is presented and compared to experimental data. METHODS: In EI, images acquired at different displacements of the presample mask (i.e., different illumination levels referred to as points on the "illumination curve"), followed by pixel-wise curve fitting, are exploited to quantitatively retrieve the three contrast channels. Therefore, the noise in the final image will depend on the error associated with the fitting process. We use a model based on the derivation of the standard error on fitted parameters, which relies on the calculation of the covariance matrix, to estimate the noise and the cross-channel correlation as a function of the position of the sampling points. In particular, we investigated the most common cases of 3 and 5 sampling points. In addition, simulations have been used to better understand the role of the integration time for each sampling point. Finally, the model is validated by comparison with the experimental data acquired with an edge illumination setup based on a tungsten rotating anode X-ray source and a photon counting detector. RESULTS: We found a good match between the predictions of the model and the experimental data. In particular, for the investigated cases, an arrangement of the sampling points leading to minimum noise and cross-channel correlation can be found. Simulations revealed that, given a fixed overall scanning time, its distribution into the smallest possible number of sampling points needed for phase retrieval leads to minimum noise thanks to higher statistics per point. CONCLUSIONS: This work presents an analytical model describing the noise in the various contrast channels retrieved in edge illumination as a function of the illumination curve sampling. In particular, an optimal sampling scheme leading to minimum noise has been determined for the case where 3 or 5 sampling points are used, which represent two of the most common acquisition schemes. In addition, the correlation between noise in the different channels and the role of the number of points and exposure time have been also investigated. In general, our results suggest a series of procedures that should be followed in order to optimize the experimental acquisitions.


Subject(s)
Lighting , Photons , Phantoms, Imaging , Radiography , X-Rays
10.
Med Phys ; 48(10): 6524-6530, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34169514

ABSTRACT

PURPOSE: Cycloidal computed tomography is a novel imaging concept which combines a highly structured x-ray beam, offset lateral under-sampling, and mathematical data recovery to obtain high-resolution images efficiently and flexibly, even with relatively large source focal spots and detector pixels. The method reduces scanning time and, potentially, delivered dose compared to other sampling schemes. This study aims to present and discuss several implementation strategies for cycloidal computed tomography (CT) in order to increase its ease of use and facilitate uptake within the imaging community. METHODS: The different implementation strategies presented are step-and-shoot, continuous unidirectional, continuous back-and-forth, and continuous pixel-wise scanning. In step-and-shoot scans the sample remains stationary while frames are acquired, whereas in all other cases the sample moves through the scanner continuously. The difference between the continuous approaches is the trajectory by which the sample moves within the field of view. RESULTS: All four implementation strategies are compatible with a standard table-top x-ray setup. With the experimental setup applied here, step-and-shoot acquisitions yield the best spatial resolution (around 30 µm), but are the most time-consuming (1.4 h). Continuous unidirectional and back-and-forth images have resolution between 30 and 40 µm, and are faster (35 min). Continuous pixel-wise images are equally time-efficient, although technical challenges caused a small loss in image quality with a resolution of about 50 µm. CONCLUSION: The authors show that cycloidal CT can be implemented in a variety of ways with high quality results. They believe this posits cycloidal CT as a powerful imaging alternative to more time-consuming and less flexible methods in the field.


Subject(s)
Tomography, X-Ray Computed , Phantoms, Imaging , Radiography , X-Rays
11.
Sci Rep ; 11(1): 3663, 2021 02 11.
Article in English | MEDLINE | ID: mdl-33574584

ABSTRACT

Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69-92%) than conventional specimen imaging (32%, 95% CI 20-49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70-92% vs 86%, 95% CI 73-93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations.


Subject(s)
Breast Neoplasms/surgery , Breast/surgery , Margins of Excision , Mastectomy, Segmental , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Female , Humans , Microscopy, Phase-Contrast , Radiography , Tomography, X-Ray Computed
12.
Med Phys ; 47(9): 4439-4449, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32602950

ABSTRACT

PURPOSE: To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each other. The second objective is to compare the hybrid images with attenuation-only images based on their respective signal-to-noise ratio (SNR). METHODS: Noise is propagated from the raw images into the retrieved hybrid images, yielding analytic expressions for the variances and noise power spectra of the latter. An expression for the relative SNR between hybrid and attenuation images is derived. A comparison with simulated data is performed. Experimental data are also shown and discussed in the context of the theory. RESULTS: The noise transfer into the retrieved hybrid images is strongly related to the setup and acquisition parameters, as well as the imaged sample itself. Consequently, the relative merit between hybrid and attenuation images also depends on these criteria. Generally, the hybrid approach tends to perform worse for highly attenuating samples, as the availability of phase contrast is outweighed by the loss of photons that is necessarily encountered in hybrid acquisitions. On the contrary, the hybrid approach can lead to a much better SNR for weakly attenuating samples, as here phase effects lead to much stronger contrast, outweighing the reduction in photon numbers. CONCLUSIONS: The analytic expressions inform the design of edge illumination setups that lead to minimum noise transfer into the retrieved hybrid images. We also anticipate our theory to guide the decision as to which imaging mode (hybrid or attenuation) to use in order to maximize SNR for a specific sample.


Subject(s)
Lighting , Photons , Phantoms, Imaging , Signal-To-Noise Ratio , X-Rays
13.
Opt Express ; 28(1): 1-19, 2020 Jan 06.
Article in English | MEDLINE | ID: mdl-32118936

ABSTRACT

Edge-illumination X-ray phase-contrast tomography (EIXPCT) is an emerging technique that enables practical phase-contrast imaging with laboratory-based X-ray sources. A joint reconstruction method was proposed for reconstructing EIXPCT images, enabling novel flexible data-acquisition designs. However, only limited efforts have been devoted to optimizing data-acquisition designs for use with the joint reconstruction method. In this study, several promising designs are introduced, such as the constant aperture position (CAP) strategy and the alternating aperture position (AAP) strategy covering different angular ranges. In computer-simulation studies, these designs are analyzed and compared. Experimental data are employed to test the designs in real-world applications. All candidate designs are also compared for their implementation complexity. The tradeoff between data-acquisition time and image quality is discussed.

14.
Phys Med Biol ; 65(10): 105007, 2020 05 15.
Article in English | MEDLINE | ID: mdl-31896094

ABSTRACT

Edge-illumination x-ray phase-contrast tomography (EIXPCT) is a promising imaging technology where partially opaque masks are utilized with laboratory-based x-ray sources to estimate the distribution of the complex-valued refractive index. EIXPCT resolution is mainly determined by the period of a sample mask, but can be significantly improved by a dithering technique. Here, dithering means that multiple images per tomographic view angle are acquired as the object is moved over sub-pixel distances. Drawbacks of dithering include increased data-acquisition times and radiation doses. Motivated by the flexibility in data-acquisition designs enabled by a recently developed joint reconstruction method, a novel partial-dithering strategy for EIXPCT data-acquisition is proposed. In this strategy, dithering is implemented at only a subset of the tomographic view angles. The strategy can result in spatial resolution comparable to that of the conventional full-dithering strategy, where dithering is performed at every view angle, but the acquisition time is substantially decreased. Here, the effect of dithering parameters on image resolution is explored.


Subject(s)
Image Processing, Computer-Assisted/methods , Lighting , Tomography, X-Ray Computed/instrumentation , Phantoms, Imaging , Refractometry
15.
Mol Imaging Biol ; 22(3): 539-548, 2020 06.
Article in English | MEDLINE | ID: mdl-31250331

ABSTRACT

PURPOSE: To enable a preliminary assessment of the suitability of edge illumination (EI) x-ray phase contrast (XPC) micro x-ray computed tomography (micro-CT) to preclinical imaging. Specifically, to understand how different acquisition schemes and their combination with dedicated data processing affect contrast-to-noise ratio (CNR) and spatial resolution, while providing control over scan time and radiation dose delivery. PROCEDURES: Deceased mice (n = 3) were scanned with an EI XPC micro-CT setup operated under different settings, leading to scan times between 18 h and 13 min. For the shortest scan, the entrance dose was measured with a calibrated PTW 23344 ion chamber. Different data processing methods were applied, retrieving either separate attenuation and phase images, or hybrid (combined attenuation and phase) images. A quantitative comparison was performed based on CNR and spatial resolution measurements for a soft tissue interface. RESULTS: All phase-based images have led to a higher CNR for the considered soft tissue interface than the attenuation image, independent of scan time. The best relative CNR (a sixfold increase) was observed in one of the hybrid images. Spatial resolution was found to be connected to scan time, with a resolution of approximately 20 µm and 60 µm achieved for the longest and shortest scans, respectively. An entrance dose of approximately 300 mGy was estimated for the scan performed within 13 min. CONCLUSIONS: Despite their preliminary nature, our results suggest that EI XPC bears potential for enhancing the utility of preclinical micro-CT, and, pending further research and development, could ultimately become a valuable technique in this field.


Subject(s)
Image Processing, Computer-Assisted/methods , Microscopy, Phase-Contrast/methods , Whole Body Imaging/methods , X-Ray Microtomography/methods , Algorithms , Animals , Mice , Radiation Dosage , Signal-To-Noise Ratio
16.
Phys Med Biol ; 64(23): 235005, 2019 11 26.
Article in English | MEDLINE | ID: mdl-31569079

ABSTRACT

A significant number of patients receiving breast-conserving surgery (BCS) for invasive carcinoma and ductal carcinoma in situ (DCIS) may need reoperation following tumor-positive margins from final histopathology tests. All current intraoperative margin assessment modalities have specific limitations. As a first step towards the development of a compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast, we prove that the system's dimensions can be reduced without affecting imaging performance. We analysed the variation in noise and contrast to noise ratio (CNR) with decreasing system length using the edge illumination x-ray phase contrast imaging setup. Two-(planar) and three-(computed tomography (CT)) dimensional imaging acquisitions of custom phantoms and a breast tissue specimen were made. Dedicated phase retrieval algorithms were used to separate refraction and absorption signals. A 'single-shot' retrieval method was also used, to retrieve thickness map images, due to its simple acquisition procedure and reduced acquisition times. Experimental results were compared to numerical simulations where appropriate. The relative contribution of dark noise signal in integrating detectors is significant for low photon count statistics acquisitions. Under constant exposure factors and magnification, a more compact system provides an increase in CNR. Superior CNR results were obtained for refraction and thickness map images when compared to absorption images. Results indicate that the 'single-shot' acquisition method is preferable for a compact CT intraoperative specimen scanner; it allows for shorter acquisition times and its combination of the absorption and refraction signals ultimately leads to a higher contrast. The first CT images of a breast specimen acquired with the compact system provided promising results when compared to those of the longer length system.


Subject(s)
Breast Neoplasms/diagnostic imaging , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Tomography, X-Ray Computed , Algorithms , Breast Neoplasms/surgery , Female , Humans , Intraoperative Period , Margins of Excision , Mastectomy, Segmental/methods , Radiography , Reoperation , Signal-To-Noise Ratio , X-Rays
17.
Phys Med Biol ; 64(20): 205008, 2019 10 10.
Article in English | MEDLINE | ID: mdl-31509810

ABSTRACT

Iterative tomographic reconstruction has been established as a viable alternative for data analysis in phase-sensitive x-ray imaging based on the edge-illumination principle. However, previously published approaches did not account for drifts of optical elements during a scan, which can lead to artefacts. Up to now, the strategy to reduce these artefacts was to acquire additional intermediate flat field images, which were used to correct the sinograms. Here, we expand the theoretical model to take these effects into account and demonstrate a significant reduction of (ring)-artefacts in the final reconstructions, while allowing for a significant reduction of scan time and dose. We further improve the model by including the capability to reconstruct combined absorption and phase contrast slices, which we experimentally demonstrate to deliver improved contrast to noise ratios compared to previously employed single shot approaches.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Models, Theoretical , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Artifacts , Computer Simulation , Humans , Lighting , X-Rays
18.
J Med Imaging (Bellingham) ; 5(2): 023501, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29963577

ABSTRACT

It is well known that properly designed image reconstruction methods can facilitate reductions in imaging doses and data-acquisition times in tomographic imaging. The ability to do so is particularly important for emerging modalities, such as differential x-ray phase-contrast tomography (D-XPCT), which are currently limited by these factors. An important application of D-XPCT is high-resolution imaging of biomedical samples. However, reconstructing high-resolution images from few-view tomographic measurements remains a challenging task due to the high-frequency information loss caused by data incompleteness. In this work, a subspace-based reconstruction strategy is proposed and investigated for use in few-view D-XPCT image reconstruction. By adopting a two-step approach, the proposed method can simultaneously recover high-frequency details within a certain region of interest while suppressing noise and/or artifacts globally. The proposed method is investigated by the use of few-view experimental data acquired by an edge-illumination D-XPCT scanner.

19.
J Med Imaging (Bellingham) ; 4(4): 040901, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29057286

ABSTRACT

Edge illumination (EI) is an x-ray phase-contrast imaging technique, exploiting sensitivity to x-ray refraction to visualize features, which are often not detected by conventional absorption-based radiography. The method does not require a high degree of spatial coherence and is achromatic and, therefore, can be implemented with both synchrotron radiation and commercial x-ray tubes. Using different retrieval algorithms, information about an object's attenuation, refraction, and scattering properties can be obtained. In recent years, a theoretical framework has been developed that enables EI computed tomography (CT) and, hence, three-dimensional imaging. This review provides a summary of these advances, covering the development of different image acquisition schemes, retrieval approaches, and applications. These developments constitute an integral part in the transformation of EI CT into a widely spread imaging tool for use in a range of fields.

20.
Opt Express ; 25(10): 11984-11996, 2017 May 15.
Article in English | MEDLINE | ID: mdl-28788753

ABSTRACT

In this paper we present a single-image phase retrieval algorithm for multi-material samples, developed for the edge illumination (EI) X-ray phase contrast imaging method. The theoretical derivation is provided, along with any assumptions made. The algorithm is evaluated quantitatively using both simulated and experimental results from a computed tomography (CT) scan using the EI laboratory implementation. Qualitative CT results are provided for a biological sample containing both bone and soft-tissue. Using a single EI image per projection and knowledge of the complex refractive index, the algorithm can accurately retrieve the interface between a given pair of materials. A composite CT slice can be created by splicing together multiple CT reconstructions, each retrieved for a different pair of materials.