In this work we present a method for dense reconstruction of anatomical structures using white light endoscopic imagery based on a learning process that estimates a mapping between light reflectance and surface geometry. Our method is unique in that few unrealistic assumptions are considered (i.e., we do not assume a Lambertian reflectance model nor do we assume a point light source) and we learn a model on a per-patient basis, thus increasing the accuracy and extensibility to different endoscopic sequences. The proposed method assumes accurate video-CT registration through a combination of Structure-from-Motion (SfM) and Trimmed-ICP, and then uses the registered 3D structure and motion to generate training data with which to learn a multivariate regression of observed pixel values to known 3D surface geometry. We demonstrate with a non-linear regression technique using a neural network towards estimating depth images and surface normal maps, resulting in high-resolution spatial 3D reconstructions to an average error of 0.53mm (on the low side, when anatomy matches the CT precisely) to 1.12mm (on the high side, when the presence of liquids causes scene geometry that is not present in the CT for evaluation). Our results are exhibited on patient data and validated with associated CT scans. In total, we processed 206 total endoscopic images from patient data, where each image yields approximately 1 million reconstructed 3D points per image.

2.
Proc SPIE Int Soc Opt Eng ; 94152015 Feb 21.
Article in English | MEDLINE | ID: mdl-25991876

ABSTRACT

We present a system for registering the coordinate frame of an endoscope to pre- or intra- operatively acquired CT data based on optimizing the similarity metric between an endoscopic image and an image predicted via rendering of CT. Our method is robust and semi-automatic because it takes account of physical constraints, specifically, collisions between the endoscope and the anatomy, to initialize and constrain the search. The proposed optimization method is based on a stochastic optimization algorithm that evaluates a large number of similarity metric functions in parallel on a graphics processing unit. Images from a cadaver and a patient were used for evaluation. The registration error was 0.83 mm and 1.97 mm for cadaver and patient images respectively. The average registration time for 60 trials was 4.4 seconds. The patient study demonstrated robustness of the proposed algorithm against a moderate anatomical deformation.

SELECTION OF CITATIONS
SEARCH DETAIL
...