Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Brain Stimul ; 17(1): 39-48, 2024.
Article in English | MEDLINE | ID: mdl-38145752

ABSTRACT

BACKGROUND: Information transmission into the human nervous system is the basis for a variety of prosthetic applications. Spinal cord stimulation (SCS) systems are widely available, have a well documented safety record, can be implanted minimally invasively, and are known to stimulate afferent pathways. Nonetheless, SCS devices are not yet used for computer-brain-interfacing applications. OBJECTIVE: Here we aimed to establish computer-to-brain communication via medical SCS implants in a group of 20 individuals who had been operated for the treatment of chronic neuropathic pain. METHODS: In the initial phase, we conducted interface calibration with the aim of determining personalized stimulation settings that yielded distinct and reproducible sensations. These settings were subsequently utilized to generate inputs for a range of behavioral tasks. We evaluated the required calibration time, task training duration, and the subsequent performance in each task. RESULTS: We could establish a stable spinal computer-brain interface in 18 of the 20 participants. Each of the 18 then performed one or more of the following tasks: A rhythm-discrimination task (n = 13), a Morse-decoding task (n = 3), and/or two different balance/body-posture tasks (n = 18; n = 5). The median calibration time was 79 min. The median training time for learning to use the interface in a subsequent task was 1:40 min. In each task, every participant demonstrated successful performance, surpassing chance levels. CONCLUSION: The results constitute the first proof-of-concept of a general purpose computer-brain interface paradigm that could be deployed on present-day medical SCS platforms.


Subject(s)
Brain-Computer Interfaces , Humans , Brain , Computers
2.
Front Neurosci ; 9: 265, 2015.
Article in English | MEDLINE | ID: mdl-26283905

ABSTRACT

Electrodes for cortical stimulation need to deliver current to neural tissue effectively and safely. We have developed electrodes with a novel annular geometry for use in cortical visual prostheses. Here, we explore a critical question on the ideal annulus height to ensure electrical stimulation will be safe and effective. We implanted single electrodes into the motor cortex of anesthetized rats and measured the current required to evoke a motor response to stimulation, and the charge injection capacity (CIC) of the electrodes. We compared platinum iridium (PtIr) electrodes with different annulus heights, with and without a coating of porous titanium nitride (TiN). Threshold charge densities to evoke a motor response ranged from 12 to 36 µC.cm(-2).ph(-1). Electrodes with larger geometric surface areas (GSAs) required higher currents to evoke responses, but lower charge densities. The addition of a porous TiN coating did not significantly influence the current required to evoke a motor response. The CIC of both electrode types was significantly reduced in vivo compared with in vitro measurements. The measured CIC was 72 and 18 µC.cm(-2).ph(-1) for electrodes with and without a TiN coating, respectively. These results support the use of PtIr annular electrodes with annulus heights greater than 100 µm (GSA of 38, 000 µm(2)). However, if the electrodes are coated with porous TiN the annulus height can be reduced to 40 µm (GSA of 16,000 µm(2)).

3.
Front Neuroeng ; 8: 5, 2015.
Article in English | MEDLINE | ID: mdl-26029097

ABSTRACT

Electrodes for cortical stimulation need to deliver current to neural tissue effectively and safely. We have developed electrodes with a novel annular geometry for use in cortical visual prostheses. Here, we explore a critical question on the ideal annulus height to ensure electrical stimulation will be safe and effective. We implanted single electrodes into the motor cortex of anesthetized rats and measured the current required to evoke a motor response to stimulation, and the charge injection capacity (CIC) of the electrodes. We compared platinum iridium (PtIr) electrodes with different annulus heights, with and without a coating of porous titanium nitride (TiN). Threshold charge densities to evoke a motor response ranged from 12 to 36 µC.cm(-2).ph(-1). Electrodes with larger geometric surface areas (GSAs) required higher currents to evoke responses, but lower charge densities. The addition of a porous TiN coating did not significantly influence the current required to evoke a motor response. The CIC of both electrode types was significantly reduced in vivo compared with in vitro measurements. The measured CIC was 72 and 18 µC.cm(-2).ph(-1) for electrodes with and without a TiN coating, respectively. These results support the use of PtIr annular electrodes with annulus heights greater than 100 µm (GSA of 38, 000 µm(2)). However, if the electrodes are coated with porous TiN the annulus height can be reduced to 40 µm (GSA of 16,000 µm(2)).

SELECTION OF CITATIONS
SEARCH DETAIL
...