Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 80
Filter
1.
PLoS One ; 19(6): e0303301, 2024.
Article in English | MEDLINE | ID: mdl-38857266

ABSTRACT

OBJECTIVE: Audio processors (AP) are the external components of hearing implants. User satisfaction with the performance and comfort of their AP is a critical factor in ensuring daily use, which leads to improved hearing outcomes. The aim of this study was to construct and validate an Arabic language translation of the APSQ for use among Arabic-speaking clinicians and patients. DESIGN: The original APSQ was translated into the Arabic language using cross-cultural adaptation measures. The final questionnaire was administered to CI users in electronic form. STUDY SAMPLE: 117 CI users (64 female) participated. A total of 179 ears were assessed. RESULTS: High levels of satisfaction with audio processors were observed among CI users. Item and scale analyses indicate that this version of the APSQ measure a homogeneous and valid construct. CONCLUSION: The Arabic version of the APSQ captures user satisfaction with hearing implant audio processors.


Subject(s)
Cochlear Implants , Language , Patient Satisfaction , Humans , Female , Surveys and Questionnaires , Male , Middle Aged , Adult , Aged , Translations , Young Adult
2.
J Clin Med ; 13(11)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38893010

ABSTRACT

Objectives: The growing adoption of cochlear implants (CIs) necessitates understanding the factors influencing long-term performance and improved outcomes. This work investigated the long-term effect of early activation of CIs on electrode impedance in a large sample of CI users at different time points. Methods: A retrospective study on 915 ears from CI patients who were implanted between 2015 and 2020. According to their CI audio processor activation time, the patients were categorized into early activation (activated 1 day after surgery, n = 481) and classical activation (activated 4 weeks after surgery, n = 434) groups. Then, the impact of the activation times on the electrode impedance values, along the electrode array contacts, at different time points up to two years was studied and analyzed. Results: The early activation group demonstrated lower impedance values across all the electrode array sections compared to the classical activation at 1 month, 1 year, and 2 years post-implantation. At 1 month, early activation was associated with a reduction of 0.34 kΩ, 0.46 kΩ, and 0.37 kΩ in the apical, middle, and basal sections, respectively. These differences persisted at subsequent intervals. Conclusions: Early activation leads to sustained reductions in the electrode impedance compared to classical activation (CA), suggesting that earlier activation might positively affect long-term CI outcomes.

3.
Int J Pediatr Otorhinolaryngol ; 181: 111990, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38796944

ABSTRACT

OBJECTIVES: The newborn hearing screening (NHS) program was globally established for early hearing loss (HL) identification and intervention. Early intervention is essential to minimize or prevent the negative consequences of HL. In Saudi Arabia, the NHS was officially implemented in 2016. Currently, its impact on the timing of cochlear implantations (CIs) in Saudi Arabia remains unclear, and information on potential hospital-related delays affecting early implantation is lacking. Thus, this study aimed to evaluate the effect of implementing the NHS on age at CI in children with prelingual deafness in a CI center in Saudi Arabia, and to evaluate the hospital timing in the CI process. METHODS: All pediatric CI users who presented for the first time to the CI committee (CIC) at a tertiary center and received their implants between 2015 and 2022 were enrolled in this study. Date of birth (DOB), date of presentation to the CI committee (DOCIC), and date of CI surgery (DOCIS) were retrospectively reviewed. RESULTS: In total, 304 CI children were included in the analysis. Approximately 55 % of the children (n = 167) were screened for HL through the NHS, whereas 45 % of the children (n = 137) were born before the launch of the NHS. Both age at the presentation to the CIC (i.e. difference between DOCIC and DOB) and age at implantation (i.e. difference between DOCIS and DOB) were significantly earlier in children who were screened for HL through the NHS than those who were not screened (P < 0.0001). The time difference between the DOCIC and DOCIS was not significantly different between the screened and unscreened children (P > 0.05). CONCLUSION: The implementation of the NHS in the tertiary center has a significant positive effect on age at presentation to the CIC and age at implantation, but not on the actual CI surgery. Further research is needed to reduce the hospital delays before the actual surgery in order to increase the likelihood of children receiving implantation early in their life.


Subject(s)
Cochlear Implantation , Hearing Tests , Neonatal Screening , Humans , Infant, Newborn , Cochlear Implantation/statistics & numerical data , Female , Retrospective Studies , Male , Saudi Arabia , Infant , Child, Preschool , Deafness/surgery , Deafness/diagnosis , Hearing Loss/diagnosis , Time-to-Treatment/statistics & numerical data , Time Factors
4.
Sci Rep ; 14(1): 9194, 2024 04 22.
Article in English | MEDLINE | ID: mdl-38649424

ABSTRACT

This retrospective study examined mastoid defects resulting from cochlear implant (CI) surgery and their potential for spontaneous regrowth across different age groups. Spontaneous closure of mastoid defects has been observed in certain CI patients during revision surgery or through post-operative temporal bone computer tomography (TB-CT). The analysis encompassed 123 CI recipients, comprising 81.3% children and 18.7% adults, who underwent post-operative TB-CT scans. Using image adjustment software, the study measured mastoid defect areas and found a significant reduction in children's defects between the initial and subsequent scans. Notably, mastoid defect areas differed significantly between children and adults at both time points. Furthermore, the analysis revealed significant correlations between mastoid defect areas and the age at implantation as well as the time elapsed since the CI surgery and the first CT scan. This study provides valuable insights for evaluating CI patients scheduled for revision surgery by assessing potential surgical challenges and duration. Furthermore, it may have a pivotal role in evaluating patients who experience postauricular swelling subsequent to CI surgery.


Subject(s)
Cochlear Implantation , Mastoid , Tomography, X-Ray Computed , Humans , Mastoid/surgery , Mastoid/diagnostic imaging , Cochlear Implantation/methods , Male , Child , Female , Child, Preschool , Adult , Retrospective Studies , Middle Aged , Adolescent , Aged , Infant , Young Adult , Cochlear Implants , Reoperation
5.
Indian J Otolaryngol Head Neck Surg ; 76(2): 1848-1856, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38566745

ABSTRACT

Myringoplasty is still the most performed otological surgery. Nevertheless, the underlay vs. overlay approaches have yet to be determined. The purpose of this study is to compare the surgical and audiological outcomes of underlay and overlay myringoplasty in perforated tympanic membrane patients. A systematic review and meta-analysis synthesizing randomized controlled trials (RCTs), which were retrieved by systematically searching of Web of Science, SCOPUS, PubMed, and Google Scholar until January 25th, 2023. RevMan version 5.4 software was used to pooled dichotomous outcomes using the risk ratio (RR) with the corresponding 95% confidence interval (CI). We registered our protocol in PROSPERO with ID: [CRD42023387432]. We included eight RCTs with 656 tympanic perforation membrane patients. Four RCTs had a low risk of overall bias, two had some concerns, and two had a high risk of bias. The underlay technique was significantly associated with a higher surgical success rate (n = 7 RCTs, RR: 1.21 with 95% CI [1.02, 1.43], P = 0.03) and audiological success rate (n = 4 RCTs, RR: 1.31 with 95% CI [1.18, 1.44], P < 0.00001). This meta-analysis underscores the potential superiority of the underlay technique in managing tympanic membrane perforations, with significant implications for surgical and audiological outcomes. However, more investigations are still necessary to confirm this result. Supplementary Information: The online version contains supplementary material available at 10.1007/s12070-023-04425-6.

6.
Sci Rep ; 14(1): 2645, 2024 02 01.
Article in English | MEDLINE | ID: mdl-38302541

ABSTRACT

Using anatomy-based fitting, we can determine the place-specific map with individualized center frequencies for each electrode contact that is a closer match to the natural pitch-place of the cochlea. The primary objective of this study is to evaluate the tonal presentation across the electrode array and to calculate the semitone difference between each adjacent pair of contacts according to their anatomy-based map. The secondary objective is to determine the distancing of the contacts that would result in an equal semitone difference with a uniform tonal presentation. A total of 167 ears were included in this retrospective study. The frequencies across the electrode arrays were found to be unequally presented. The semitonal condensations were higher in the apical inter-contact spaces compared to the basal inter-contact spaces, being 3.0-2.3 semitones/mm (Kruskal Wallis test, p < 0.000). The anatomy-based spacing of the electrode contacts was larger in the basal inter-contact spaces compared to the apical inter-contact spaces, ranging from 1.92 to 1.48 mm. In conclusion, the current electrode designs do not have uniform tonal representation throughout the electrode array. There is a more condensed tonal presentation in the apical electrodes than in the basal electrodes, resulting in a lower tonal resolution in the apical region.


Subject(s)
Cochlear Implantation , Cochlear Implants , Retrospective Studies , Cochlear Implantation/methods , Cochlea , Electrodes, Implanted , Caffeine
7.
Otol Neurotol ; 45(2): 107-113, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38206059

ABSTRACT

BACKGROUND: Anatomy-based fitting (ABF) is a new research area in the field of cochlear implants (CIs). Despite the reported benefits and acceptable levels of ABF among CI recipients, some limitations remain, like the postoperative computed tomography (CT) scan, which is preferred for confirming electrode array insertion. OBJECTIVE: This study aimed to investigate the feasibility of using plain film radiography (X-ray) for postoperative electrode detection and for building ABF as an alternative to CT. METHODS: A total of 53 ears with CI were studied. All cases had routine post-insertion X-rays in the cochlear view and additionally underwent postoperative CT. The insertion angles and center frequencies measured by two independent observers were compared for each imaging modality. The angular insertion depth and center frequencies resulting from the X-ray and CT scans were then compared. RESULTS: No significant differences were observed between the X-ray- and CT-measured angles for the electrode contacts. Radiographic measurements between the two readers showed an almost perfect (≥0.8) or substantial (0.71) intraclass correlation coefficient along the electrode contacts. X-ray images showed a mean difference of 4.7 degrees from CT. The mean semitone deviation of the central frequency between the CT and X-ray images was 0.6. CONCLUSIONS: X-ray imaging provides a valid and easy-to-perform alternative to CT imaging, with less radiation exposure and lower costs. The radiographs showed excellent concordance with the CT-measured angular insertion depth and consequently with the central frequency for most electrode contacts. Therefore, plain X-ray could be a viable alternative in building ABF for the CI recipients.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , X-Rays , Radiography , Tomography, X-Ray Computed
8.
Cureus ; 15(11): e49733, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38046713

ABSTRACT

This paper provides a step-by-step guide for organizing the scientific program (OSP) of international conferences. Through informal discussions, a panel of experts organizing international conferences came up with this guide, which includes a flowchart, checklist, and detailed discussions of each step. Subsequently, additional specialists were invited to evaluate this synopsis and provide their input. All of the participants approved the final version after the outline was improved. This guide proposes the following six steps: 1) preparation, 2) recruitment, 3) building the agenda, 4) cross-checking the program, 5) reviewing and finalizing, and 6) in-conference refining. Thirteen items are specified across the six main steps in a detailed checklist. This OSP guide includes a flowchart and a checklist for providing a comprehensive manual for establishing, conducting, and organizing international scientific conferences. Understanding the procedures that are expected to be followed when holding a scientific conference enables the involved parties to organize and assign tasks to one another as well as create a schedule that allows them to finish their work on time. This guide can be used at any kind of scientific conference to describe an organized process, resulting in a professional and distinguished scientific program.

9.
J Int Adv Otol ; 19(6): 447-453, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38088315

ABSTRACT

BACKGROUND: RONDO 2 is a lightweight, compact, wirelessly charged, and fully integrated single-unit speech processor. Single-unit processors provide an effective and convenient alternative to behind-the-ear processors for adults. Therefore, the aim of this study was to investigate if RONDO 2 is suitable for and did not compromise the hearing performance of young children in everyday life. METHODS: Thirteen children aged -lt;4 years were fitted with the RONDO 2 speech processor at the first activation of the cochlear implant. They were evaluated with the LittlEARS® Auditory Questionnaire, LittlEARS® Early Speech Production Questionnaire, and the Speech, Spatial, and Qualities of Hearing Scale 12 pre-implantation. In addition to these measures, they were evaluated with the Audio Processor Satisfaction Questionnaire post-implantation. Duration of daily use and troubleshooting data were acquired. Evaluation occurred at 4 time points: before implantation and 1, 3, and 12 months post-initial activation. RESULTS: Ten out of 13 children continued using RONDO 2 after the study. Twelve months after implantation, they used it on average 11.6 hours per day and had an average Audio Processor Satisfaction Questionnaire score of 9.1 out of 10. Average hearing performance scores continuously improved throughout the follow-up period across measures. Twelve months after implantation, the mean scores were 30.1 out of 35 for the LittlEARS® Auditory Questionnaire, 19.9 out of 27 for the LittlEARS® Early Speech Production Questionnaire, and 7.4 out of 10 for the Speech, Spatial, and Qualities of Hearing Scale 12. CONCLUSION: Participants demonstrated high levels of satisfaction and good hearing performance with RONDO 2, which indicates that this single-unit processor could be a viable and comfortable alternative to behind-the-ear processors in young children, although larger controlled experiments are warranted.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Adult , Child , Humans , Child, Preschool , Hearing , Hearing Tests
10.
J Pers Med ; 13(10)2023 Oct 04.
Article in English | MEDLINE | ID: mdl-37888073

ABSTRACT

The objective of this study is to review our experience with simultaneous bilateral cochlear implantation (BiCI) in adults, and assess its feasibility. This could shorten the time required to regain binaural hearing, prevent social isolation, and potentially eliminate the need for hearing aids, as seen with sequential BiCI. A retrospective study was conducted involving adult patients who received simultaneous BiCI at our center between 2010 and 2023. The feasibility of simultaneous BiCI was assessed through postoperative clinical evaluations, outpatient visits, discharge status, and the acceptance of device fitting. Twenty-seven patients underwent simultaneous BiCIs. Their mean age was 37 years, comprising 59.3% males and 40.7% females. Out of the included patients, 51.9% had childhood-onset hearing loss, while 29.6% developed hearing loss later in life. Causes of hearing loss included meningitis 7.4%, trauma 11.1%, non-specific high-grade fever 11.1%, and Brucellosis infection 3.7%. Labyrinthine ossificans (LO) was present in 7.4%, and retrofenestral otospongiosis in 3.7%. The post-operative period and initial outpatient visit were uneventful for 88.8% and 81.5% of patients, respectively. Intraoperative complications were absent in 96.2% of cases. Simultaneous BiCI is feasible in adults without major intraoperative complications or troublesome recovery periods, offering potential benefits by reducing the number of surgeries and hospital admissions compared to the sequential method.

11.
Ear Nose Throat J ; : 1455613231188294, 2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37551795

ABSTRACT

Objectives: The present literature review discusses the chronological evolution of Cochlear Implant (CI) activation and its definition among the relevant studies in the literature. In addition, the benefits of standardizing the early activation process in implantation centers worldwide are discussed. Methods: A comprehensive literature search was conducted in the major databases such as PubMed, Scopus, and Embase to retrieve all the relevant articles that reported early activation approaches following CI. Results: The evolution of the timing of early activation after CI has been remarkable in the past few years. Some studies reported the feasibility of early activation 1 day after the CI surgery in their users. Conclusions: Within the last decade, some studies have been published to report the feasibility and outcomes of its early activation. However, the process of early activation was not adequately defined, and no apparent guidelines could be found in the literature.

12.
Eur Arch Otorhinolaryngol ; 280(12): 5153-5165, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37540270

ABSTRACT

PURPOSE: To compare the efficacy and safety of temporalis fascia (TF) with cartilage grafts for primary type 1 tympanoplasty in chronic otitis media (COM) patients. METHODS: Computerized search was performed in MEDLINE, Embase, and CENTRAL. Eligible for inclusion were randomized controlled trials (RCTs) comparing TF and cartilage grafts in individuals with non-cholesteatoma COM and intact ossicles requiring type 1 tympanoplasty. Primary outcomes were graft success and hearing improvement, measured by the air-bone gap (ABG) closure. The secondary outcome was the occurrence of complications. Standardized mean differences (SMD) and odds ratios (OR) with 95% confidence intervals were calculated. RESULTS: Eighteen RCTs that enrolled 1273 participants were found eligible. Data were reported at follow-up periods ranging from 6 weeks to 24 months. The pooled effect estimate revealed a higher and statistically significant graft success favoring cartilage grafts at 12 months (OR = 2.24, 95% CI 1.33-3.78) and 24 months (OR = 2.96, 95% CI 1.18-7.43). There was no significant difference between both grafts in post-operative ABG closure across all follow-up periods (6 weeks to 12 months). CONCLUSIONS: Compared to TF, primary type 1 cartilage tympanoplasty offers better graft uptake rates and comparable postoperative hearing outcomes for COM patients.


Subject(s)
Otitis Media , Tympanic Membrane Perforation , Humans , Tympanoplasty , Treatment Outcome , Randomized Controlled Trials as Topic , Cartilage/transplantation , Fascia/transplantation , Otitis Media/surgery , Chronic Disease , Muscles , Tympanic Membrane Perforation/surgery
13.
Otol Neurotol ; 44(8): 767-774, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37464460

ABSTRACT

OBJECTIVE: Cochlear implantation (CI) has been reported as a treatment modality for radiation-induced sensorineural hearing loss (SNHL). However, its efficacy is based on individual reports with no cumulative supporting evidence. Therefore, we conducted the current systematic review to provide cumulative evidence regarding the feasibility and safety of CI in this context. DATABASES REVIEWED: An online bibliographic search was conducted in PubMed, ProQuest, Scopus, Google Scholar, and Web of Science using MeSH-based terms. METHODS: A systematic review was conducted to retrieve both observational and interventional studies that reported the outcomes of CI for patients suffering from radiation-induced SNHL. RESULTS: We included 12 studies that recruited 88 patients who underwent CI because of radiation-induced SNHL. All included studies reported satisfactory hearing/speech perception outcomes. No serious complications were reported, whereas some manageable adverse events were reported, such as paroxysmal facial spams (n = 1), postauricular wound dehiscence with mastoid cutaneous fistula (n = 1), dehiscence in blind sac closure (n = 1), and electrode exposure (n = 1). Four studies assessed the postoperative quality of life/patient satisfaction, showing improved outcomes. CONCLUSION: CI could be considered to be feasible and safe in patients with irradiation-induced SNHL. The adverse events of CI in such cases are manageable. Future studies are needed to be strengthened this context.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Loss, Sensorineural , Hearing Loss , Speech Perception , Humans , Cochlear Implantation/adverse effects , Quality of Life , Hearing Loss/surgery , Deafness/surgery , Hearing Loss, Sensorineural/surgery , Hearing Loss, Sensorineural/complications , Cochlear Implants/adverse effects , Treatment Outcome
14.
Eur Arch Otorhinolaryngol ; 280(8): 3503-3514, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37081199

ABSTRACT

PURPOSE: To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) that evaluated the surgical outcomes of type-1 tympanoplasty with and without gelfoam middle ear packing. METHODS: PubMed, CENTRAL, Scopus, Web of Science, and Google Scholar databases were screened from inception until October 2022. The included RCTs were evaluated for risk of bias, and the quality of each outcome was assessed according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system. RESULTS: Nine RCTs with 773 participants (gelfoam = 381 and non-gelfoam = 392) were analyzed. The overall study quality varied: low risk (n = 4 RCTs), some concerns (n = 3 RCTs), and high risk (n = 2 RCTs). There were no significant differences between both arms regarding the graft uptake rate (moderate certainty), hearing improvement rate (moderate certainty), type of impedance audiometry (moderate certainty), and ear discharge (low certainty). The mean change in air-bone gap was significantly higher in the non-gelfoam arm compared with the gelfoam arm (low certainty). However, the non-gelfoam group had superior hearing improvement in only the early postoperative period (i.e., one month); however, after two, three, and six months, there were no significant differences between both arms. The rate of ear fullness was significantly higher in the gelfoam arm compared with the non-gelfoam arm (moderate certainty). CONCLUSION: Among patients undergoing type-1 tympanoplasty, the surgical outcomes did not significantly differ between both arms. The practice of middle ear packing with gelfoam needs to be standardized.


Subject(s)
Myringoplasty , Tympanoplasty , Humans , Ear, Middle/surgery
15.
Eur Arch Otorhinolaryngol ; 280(8): 3489-3502, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37097468

ABSTRACT

PURPOSE: To systematically review the outcomes of early activation following cochlear implantation (CI) based on the findings from different studies in the literature. METHODS: A comprehensive search strategy was conducted through different databases to identify relevant articles. Our outcomes included impedance levels, rates of complications, hearing and speech perception performance, and patients' satisfaction levels. RESULTS: The total number of included studies in this systematic review is 19, which recruited 1157 patients, including 857 who underwent early activation following CI. Seventeen studies investigated impedance levels or feasibility rates of early activation approaches. Most of these studies (n = 10) reported that mean impedance levels remarkably decreased within the first day-to-month (first measurement) post-activation. In addition, all 17 studies showed that impedance levels finally normalize and become comparable with intraoperative levels or the conventional activation group. Seventeen studies reported the occurrence of complications in their population. Ten of these studies indicated that none of their patients developed any post-operative complications after early activation. Seven studies reported the development of some minor complications, including pain 9.2% (28/304), infection 4.7% (13/275), swelling 8.2% (25/304), vertigo 15.1% (8/53), skin hyperemia 2.2% (5/228), and others 16.4% (9/55). Hearing and speech perception was assessed in six studies, which showed a remarkable improvement in their patients. Three studies investigated patients' satisfaction and showed high satisfaction levels. Only one report investigated the economic advantages of early activation. CONCLUSION: Early activation is safe and feasible and does not impact the hearing and speech outcomes of the patients undergoing CI procedures.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Humans , Cochlear Implantation/adverse effects , Cochlear Implantation/methods , Postoperative Complications/epidemiology , Vertigo , Patient Satisfaction , Speech Perception/physiology , Treatment Outcome
16.
J Pers Med ; 13(3)2023 Mar 21.
Article in English | MEDLINE | ID: mdl-36983743

ABSTRACT

The effect of insertion depth and position of cochlear implant (CI) electrode arrays on speech perception remains unclear. This study aimed to determine the relationship between cochlear coverage and speech performance in children with prelingual hearing loss with CI. Pure tone audiometry (PTA) and speech audiometry, including speech reception threshold (SRT) using spondee words and speech discrimination score (SDS) using phonetically balanced monosyllabic words, were tested. The Categories of Auditory Performance (CAP) and Speech Intelligibility Rating (SIR) scales were also used. Thirty-one ears were implanted with the FLEX 28 electrode array, and 54 with the FORM 24 were included in the current study. For the studied ear, the mean cochlear duct length was 30.82 ± 2.24 mm; the mean cochlear coverage was 82.78 ± 7.49%. Cochlear coverage was a significant negative predictor for the mean pure tone threshold across frequecnies of 0.5, 1, 2, and 4 kHz (PTA4) (p = 0.019). Cochlear coverage was a significant positive predictor of SDS (p = 0.009). In children with cochlear coverage ≥ 82.78%, SDS was significantly better than in those with coverage < 82.78% (p = 0.04). Cochlear coverage was not a significant predictor of the SRT, CAP, or SIR. In conclusion, the cochlear coverage of the CI electrode array has an impact on the users' SDS. Further long-term studies with larger sample sizes should be conducted to address the most critical factors affecting CI recipients' outcomes.

17.
Ear Nose Throat J ; : 1455613221134742, 2023 Jan 07.
Article in English | MEDLINE | ID: mdl-36609169

ABSTRACT

OBJECTIVES: This study aimed to define the best electrode trajectory line in cochlear implant (CI) surgery using the OTOPLAN (otology planning software) reconstructed 3D model and to investigate the surgical distance of the retro-facial approach as a direct access to the round window. METHODS: Computed tomography (CT) scans of the normal temporal bone were included for analysis in this study. OTOPLAN reconstruction was used to build 3D models with specific ear structures for study analysis. RESULTS: Twenty-five scans were included; the average age at the time of CT scan was 6.8±12 years. Twelve scans (48%) were right-sided and thirteen (52%) were left-sided. The best trajectory line to the round window was identified in all scans. The retro-facial approach was the optimal approach for 52% of cases (13/25). In all scans, the safe distance from the facial nerve were in favor of the retro-facial approach (P = 0.0011). CONCLUSION: The OTOPLAN reconstructed imaging provided a good analysis of the retro-facial approach and helped in planning the surgical trajectory line towards the round window. Additionally, calculation of the surgical distance can help the surgeon compare the retro-facial approach to the standard facial recess for preoperative planning. These findings may help in robotic surgery.

18.
Cureus ; 14(11): e31348, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36514561

ABSTRACT

Background In this study, we aimed to investigate the effect of the coronavirus disease 2019 (COVID-19) pandemic-induced social restrictions, including face masks, on patients with hearing problems. Methodology This cross-sectional survey study was conducted in an ENT tertiary care center. After signing the consent form, we invited study subjects with hearing disabilities who were using unilateral or bilateral hearing aids to participate in filling out the study survey. The study questionnaire was completed by 80 subjects. The questionnaire included various questions about the respondent's demographics, hearing aids, and communication with a face mask during COVID-19 restrictions. All statistical analyses were performed using SPSS version 19 (IBM Corp., Armonk, NY, USA). Results Overall, 40% of the study sample agreed that understanding people wearing face masks is harder because their speech is muffled, whereas 10% disagreed, and 50% were neutral. While 41.3% agreed that understanding is harder because they cannot see their mouth moving, 23.8% disagreed, and 35% were neutral. More than half of the study sample (55%) agreed that they are worried about how they will communicate with others if wearing face masks becomes more common. However, 50% of the participants thought that they can still hear people when they speak to them from a safe distance. Of note, 71.3% of subjects disagreed about tinnitus being worse since the lockdown. Conclusions The widespread use of face masks had a significant impact on the daily communication and interactions of people with hearing impairments. More research is needed to find creative ways to help these patients improve their daily communication and social interactions.

19.
Laryngoscope Investig Otolaryngol ; 7(6): 2020-2028, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36544941

ABSTRACT

Objective: We hypothesize that visualizing inner-ear systematically in both cochlear view (oblique coronal plane) and in mid-modiolar section (axial plane) and following three sequential steps simplifies, identification of inner-ear malformation types. Methods: Pre-operative computer-tomography (CT) scans of temporal bones of 112 ears with various inner ear malformation (IEM) types were taken for analysis. Images were analyzed using DICOM viewers, 3D slicer, and OTOPLAN®. The inner-ear was captured in the oblique-coronal plane for the measurement of length and width of cochlear basal turn which is also called as A-, and B-values respectively (Step 1). In the same plane, the angular-turns of lateral-wall (LW) of cochlear basal turn were measured (Step 2). As Step 3, the mid-modiolar section of inner ear was captured in the axial plane by following the A-value and perpendicular to cochlear view. From the mid-modiolar section, the outer-contour of inner ear was captured manually by following contrasting gray area between fluid filled and bony promontory and was compared to known resembling objects to identify IEM types (Step 3). Results: Following reference values have emerged from our analysis: A-, and B-values (Step 1) on average are >8 mm and >5.5 mm respectively, in normal cochleae (NA), enlarged vestibular aqueduct syndrome (EVAS), incomplete partition (IP) type-I and -II, whereas it is <8 mm and <5.5 mm respectively, in IP type-III and cochlear hypoplasia (CH). Angular-turn of LW is consistently observed in cochlear basal turn (Step 2), is 540° in NA and EVAS, 450° in IP-II, and 360° in IP types I & III. In subjects with CH type, angular-turn of LW is either 360° or 450° or 540°. In true mid-modiolar section, outer-contour of inner-ear (Step-3), other than in CH and cystic inner-ear malformations, resembles recognizable shapes of known objects. Absence of EVA is an additional characteristic that confirms diagnosis of CH when the A-, B-values, and angular-turn of LW can be similar to other anatomical types. Drawing a straight line along posterior edge of internal auditory canal (IAC) in axial view can differentiate a true common cavity (CC) from cochlear aplasia-vestibular cavity (VC). Conclusion: Three-step process proposed in this study captures inner-ear in cochlear view as well in mid-modiolar sections visualizing key features of inner-ear in identification of IEM types. Level of Evidence: Level 1.

20.
Biomed Res Int ; 2022: 2239152, 2022.
Article in English | MEDLINE | ID: mdl-35909490

ABSTRACT

One of the most widely used measures of scientific impact is the number of citations. However, due to its heavy-tailed distribution, citations are fundamentally difficult to predict but can be improved. This study was aimed at investigating the factors and parts influencing the citation number of a scientific paper in the otology field. Therefore, this work proposes a new solution that utilizes machine learning and natural language processing to process English text and provides a paper citation as the predicted results. Different algorithms are implemented in this solution, such as linear regression, boosted decision tree, decision forest, and neural networks. The application of neural network regression revealed that papers' abstracts have more influence on the citation numbers of otological articles. This new solution has been developed in visual programming using Microsoft Azure machine learning at the back end and Programming Without Coding Technology at the front end. We recommend using machine learning models to improve the abstracts of research articles to get more citations.


Subject(s)
Machine Learning , Otolaryngology , Algorithms , Linear Models
SELECTION OF CITATIONS
SEARCH DETAIL
...