Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
JCI Insight ; 9(3)2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38127464

ABSTRACT

BACKGROUNDInformation about the size, airway location, and longitudinal behavior of mucus plugs in asthma is needed to understand their role in mechanisms of airflow obstruction and to rationally design muco-active treatments.METHODSCT lung scans from 57 patients with asthma were analyzed to quantify mucus plug size and airway location, and paired CT scans obtained 3 years apart were analyzed to determine plug behavior over time. Radiologist annotations of mucus plugs were incorporated in an image-processing pipeline to generate size and location information that was related to measures of airflow.RESULTSThe length distribution of 778 annotated mucus plugs was multimodal, and a 12 mm length defined short ("stubby", ≤12 mm) and long ("stringy", >12 mm) plug phenotypes. High mucus plug burden was disproportionately attributable to stringy mucus plugs. Mucus plugs localized predominantly to airway generations 6-9, and 47% of plugs in baseline scans persisted in the same airway for 3 years and fluctuated in length and volume. Mucus plugs in larger proximal generations had greater effects on spirometry measures than plugs in smaller distal generations, and a model of airflow that estimates the increased airway resistance attributable to plugs predicted a greater effect for proximal generations and more numerous mucus plugs.CONCLUSIONPersistent mucus plugs in proximal airway generations occur in asthma and demonstrate a stochastic process of formation and resolution over time. Proximal airway mucus plugs are consequential for airflow and are in locations amenable to treatment by inhaled muco-active drugs or bronchoscopy.TRIAL REGISTRATIONClinicaltrials.gov; NCT01718197, NCT01606826, NCT01750411, NCT01761058, NCT01761630, NCT01716494, and NCT01760915.FUNDINGAstraZeneca, Boehringer-Ingelheim, Genentech, GlaxoSmithKline, Sanofi-Genzyme-Regeneron, and TEVA provided financial support for study activities at the Coordinating and Clinical Centers beyond the third year of patient follow-up. These companies had no role in study design or data analysis, and the only restriction on the funds was that they be used to support the SARP initiative.


Subject(s)
Asthma , Humans , Bronchoscopy , Lung/diagnostic imaging , Mucus , Tomography, X-Ray Computed
2.
Radiol Cardiothorac Imaging ; 5(4): e220221, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37693197

ABSTRACT

Purpose: To assess if a novel automated method to spatially delineate and quantify the extent of hypoperfusion on multienergy CT angiograms can aid the evaluation of chronic thromboembolic pulmonary hypertension (CTEPH) disease severity. Materials and Methods: Multienergy CT angiograms obtained between January 2018 and December 2020 in 51 patients with CTEPH (mean age, 47 years ± 17 [SD]; 27 women) were retrospectively compared with those in 110 controls with no imaging findings suggestive of pulmonary vascular abnormalities (mean age, 51 years ± 16; 81 women). Parenchymal iodine values were automatically isolated using deep learning lobar lung segmentations. Low iodine concentration was used to delineate areas of hypoperfusion and calculate hypoperfused lung volume (HLV). Receiver operating characteristic curves, correlations with preoperative and postoperative changes in invasive hemodynamics, and comparison with visual assessment of lobar hypoperfusion by two expert readers were evaluated. Results: Global HLV correctly separated patients with CTEPH from controls (area under the receiver operating characteristic curve = 0.84; 10% HLV cutoff: 90% sensitivity, 72% accuracy, and 64% specificity) and correlated moderately with hemodynamic severity at time of imaging (pulmonary vascular resistance [PVR], ρ = 0.67; P < .001) and change after surgical treatment (∆PVR, ρ = -0.61; P < .001). In patients surgically classified as having segmental disease, global HLV correlated with preoperative PVR (ρ = 0.81) and postoperative ∆PVR (ρ = -0.70). Lobar HLV correlated moderately with expert reader lobar assessment (ρHLV = 0.71 for reader 1; ρHLV = 0.67 for reader 2). Conclusion: Automated quantification of hypoperfused areas in patients with CTEPH can be performed from clinical multienergy CT examinations and may aid clinical evaluation, particularly in patients with segmental-level disease.Keywords: CT-Spectral Imaging (Multienergy), Pulmonary, Pulmonary Arteries, Embolism/Thrombosis, Chronic Thromboembolic Pulmonary Hypertension, Multienergy CT, Hypoperfusion© RSNA, 2023.

3.
Radiol Cardiothorac Imaging ; 5(3): e220202, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37404797

ABSTRACT

Purpose: To assess the feasibility of a newly developed algorithm, called deep learning synthetic strain (DLSS), to infer myocardial velocity from cine steady-state free precession (SSFP) images and detect wall motion abnormalities in patients with ischemic heart disease. Materials and Methods: In this retrospective study, DLSS was developed by using a data set of 223 cardiac MRI examinations including cine SSFP images and four-dimensional flow velocity data (November 2017 to May 2021). To establish normal ranges, segmental strain was measured in 40 individuals (mean age, 41 years ± 17 [SD]; 30 men) without cardiac disease. Then, DLSS performance in the detection of wall motion abnormalities was assessed in a separate group of patients with coronary artery disease, and these findings were compared with consensus results of four independent cardiothoracic radiologists (ground truth). Algorithm performance was evaluated by using receiver operating characteristic curve analysis. Results: Median peak segmental radial strain in individuals with normal cardiac MRI findings was 38% (IQR: 30%-48%). Among patients with ischemic heart disease (846 segments in 53 patients; mean age, 61 years ± 12; 41 men), the Cohen κ among four cardiothoracic readers for detecting wall motion abnormalities was 0.60-0.78. DLSS achieved an area under the receiver operating characteristic curve of 0.90. Using a fixed 30% threshold for abnormal peak radial strain, the algorithm achieved a sensitivity, specificity, and accuracy of 86%, 85%, and 86%, respectively. Conclusion: The deep learning algorithm had comparable performance with subspecialty radiologists in inferring myocardial velocity from cine SSFP images and identifying myocardial wall motion abnormalities at rest in patients with ischemic heart disease.Keywords: Neural Networks, Cardiac, MR Imaging, Ischemia/Infarction Supplemental material is available for this article. © RSNA, 2023.

4.
Radiographics ; 43(2): e220078, 2023 02.
Article in English | MEDLINE | ID: mdl-36525366

ABSTRACT

Management of chronic thromboembolic pulmonary hypertension (CTEPH) should be determined by a multidisciplinary team, ideally at a specialized CTEPH referral center. Radiologists contribute to this multidisciplinary process by helping to confirm the diagnosis of CTEPH and delineating the extent of disease, both of which help determine a treatment decision. Preoperative assessment of CTEPH usually employs multiple imaging modalities, including ventilation-perfusion (V/Q) scanning, echocardiography, CT pulmonary angiography (CTPA), and right heart catheterization with pulmonary angiography. Accurate diagnosis or exclusion of CTEPH at imaging is imperative, as this remains the only form of pulmonary hypertension that is curative with surgery. Unfortunately, CTEPH is often misdiagnosed at CTPA, which can be due to technical factors, patient-related factors, radiologist-related factors, as well as a host of disease mimics including acute pulmonary embolism, in situ thrombus, vasculitis, pulmonary artery sarcoma, and fibrosing mediastinitis. Although V/Q scanning is thought to be substantially more sensitive for CTEPH compared with CTPA, this is likely due to lack of recognition of CTEPH findings rather than a modality limitation. Preoperative evaluation for pulmonary thromboendarterectomy (PTE) includes assessment of technical operability and surgical risk stratification. While the definitive therapy for CTEPH is PTE, other minimally invasive or noninvasive therapies also lead to clinical improvements including greater survival. Complications of PTE that can be identified at postoperative imaging include infection, reperfusion edema or injury, pulmonary hemorrhage, pericardial effusion or hemopericardium, and rethrombosis. ©RSNA, 2022 Online supplemental material is available for this article.


Subject(s)
Hypertension, Pulmonary , Pulmonary Embolism , Humans , Hypertension, Pulmonary/diagnostic imaging , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/surgery , Pulmonary Embolism/complications , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/surgery , Endarterectomy/adverse effects , Endarterectomy/methods , Angiography/methods , Radiologists , Chronic Disease
7.
NPJ Digit Med ; 5(1): 120, 2022 Aug 19.
Article in English | MEDLINE | ID: mdl-35986059

ABSTRACT

We introduce a multi-institutional data harvesting (MIDH) method for longitudinal observation of medical imaging utilization and reporting. By tracking both large-scale utilization and clinical imaging results data, the MIDH approach is targeted at measuring surrogates for important disease-related observational quantities over time. To quantitatively investigate its clinical applicability, we performed a retrospective multi-institutional study encompassing 13 healthcare systems throughout the United States before and after the 2020 COVID-19 pandemic. Using repurposed software infrastructure of a commercial AI-based image analysis service, we harvested data on medical imaging service requests and radiology reports for 40,037 computed tomography pulmonary angiograms (CTPA) to evaluate for pulmonary embolism (PE). Specifically, we compared two 70-day observational periods, namely (i) a pre-pandemic control period from 11/25/2019 through 2/2/2020, and (ii) a period during the early COVID-19 pandemic from 3/8/2020 through 5/16/2020. Natural language processing (NLP) on final radiology reports served as the ground truth for identifying positive PE cases, where we found an NLP accuracy of 98% for classifying radiology reports as positive or negative for PE based on a manual review of 2,400 radiology reports. Fewer CTPA exams were performed during the early COVID-19 pandemic than during the pre-pandemic period (9806 vs. 12,106). However, the PE positivity rate was significantly higher (11.6 vs. 9.9%, p < 10-4) with an excess of 92 PE cases during the early COVID-19 outbreak, i.e., ~1.3 daily PE cases more than statistically expected. Our results suggest that MIDH can contribute value as an exploratory tool, aiming at a better understanding of pandemic-related effects on healthcare.

8.
Radiol Cardiothorac Imaging ; 4(3): e220029, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35923748

ABSTRACT

Supplemental material is available for this article.

9.
Radiol Artif Intell ; 4(2): e210160, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35391767

ABSTRACT

Quantitative imaging measurements can be facilitated by artificial intelligence (AI) algorithms, but how they might impact decision-making and be perceived by radiologists remains uncertain. After creation of a dedicated inspiratory-expiratory CT examination and concurrent deployment of a quantitative AI algorithm for assessing air trapping, five cardiothoracic radiologists retrospectively evaluated severity of air trapping on 17 examination studies. Air trapping severity of each lobe was evaluated in three stages: qualitatively (visually); semiquantitatively, allowing manual region-of-interest measurements; and quantitatively, using results from an AI algorithm. Readers were surveyed on each case for their perceptions of the AI algorithm. The algorithm improved interreader agreement (intraclass correlation coefficients: visual, 0.28; semiquantitative, 0.40; quantitative, 0.84; P < .001) and improved correlation with pulmonary function testing (forced expiratory volume in 1 second-to-forced vital capacity ratio) (visual r = -0.26, semiquantitative r = -0.32, quantitative r = -0.44). Readers perceived moderate agreement with the AI algorithm (Likert scale average, 3.7 of 5), a mild impact on their final assessment (average, 2.6), and a neutral perception of overall utility (average, 3.5). Though the AI algorithm objectively improved interreader consistency and correlation with pulmonary function testing, individual readers did not immediately perceive this benefit, revealing a potential barrier to clinical adoption. Keywords: Technology Assessment, Quantification © RSNA, 2021.

10.
Radiol Artif Intell ; 4(2): e210162, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35391776

ABSTRACT

CT pulmonary angiography (CTPA) is the first-line imaging test for evaluation of acute pulmonary emboli. However, diagnostic quality is heterogeneous across institutions and is frequently limited by suboptimal pulmonary artery (PA) contrast enhancement. In this retrospective study, a deep learning algorithm for measuring enhancement of the central PAs was developed and assessed for feasibility of its use in quality improvement of CTPA. In a convenience sample of 450 patients, automated measurement of CTPA enhancement showed high agreement with manual radiologist measurement (r = 0.996). Using a threshold of less than 250 HU for suboptimal enhancement, the sensitivity and specificity of the automated classification were 100% and 99.5%, respectively. The algorithm was further evaluated in a random sampling of 3195 CTPA examinations from January 2019 through May 2021. Beginning in January 2021, the scanning protocol was transitioned from bolus tracking to a timing bolus strategy. Automated analysis of these examinations showed that most suboptimal examinations following the change in protocol were performed using one scanner, highlighting the potential value of deep learning algorithms for quality improvement in the radiology department. Keywords: CT Angiography, Pulmonary Arteries © RSNA, 2022.

11.
J Thorac Imaging ; 37(2): 90-99, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-34710891

ABSTRACT

PURPOSE: To assess the potential of a transfer learning strategy leveraging radiologist supervision to enhance convolutional neural network-based (CNN) localization of pneumonia on radiographs and to further assess the prognostic value of CNN severity quantification on patients evaluated for COVID-19 pneumonia, for whom severity on the presenting radiograph is a known predictor of mortality and intubation. MATERIALS AND METHODS: We obtained an initial CNN previously trained to localize pneumonia along with 25,684 radiographs used for its training. We additionally curated 1466 radiographs from patients who had a computed tomography (CT) performed on the same day. Regional likelihoods of pneumonia were then annotated by cardiothoracic radiologists, referencing these CTs. Combining data, a preexisting CNN was fine-tuned using transfer learning. Whole-image and regional performance of the updated CNN was assessed using receiver-operating characteristic area under the curve and Dice. Finally, the value of CNN measurements was assessed with survival analysis on 203 patients with COVID-19 and compared against modified radiographic assessment of lung edema (mRALE) score. RESULTS: Pneumonia detection area under the curve improved on both internal (0.756 to 0.841) and external (0.864 to 0.876) validation data. Dice overlap also improved, particularly in the lung bases (R: 0.121 to 0.433, L: 0.111 to 0.486). There was strong correlation between radiologist mRALE score and CNN fractional area of involvement (ρ=0.85). Survival analysis showed similar, strong prognostic ability of the CNN and mRALE for mortality, likelihood of intubation, and duration of hospitalization among patients with COVID-19. CONCLUSIONS: Radiologist-supervised transfer learning can enhance the ability of CNNs to localize and quantify the severity of disease. Closed-loop systems incorporating radiologists may be beneficial for continued improvement of artificial intelligence algorithms.


Subject(s)
COVID-19 , Pneumonia , Artificial Intelligence , Humans , Machine Learning , Pneumonia/diagnostic imaging , Radiologists , Retrospective Studies , SARS-CoV-2
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3912-3915, 2021 11.
Article in English | MEDLINE | ID: mdl-34892087

ABSTRACT

Patients with initially uncomplicated typeB aortic dissection (uTBAD) remain at high risk for developing late complications. Identification of morphologic features for improving risk stratification of these patients requires automated segmentation of computed tomography angiography (CTA) images. We developed three segmentation models utilizing a 3D residual U-Net for segmentation of the true lumen (TL), false lumen (FL), and false lumen thrombosis (FLT). Model 1 segments all labels at once, whereas model 2 segments them sequentially. Best results for TL and FL segmentation were achieved by model 2, with median (interquartiles) Dice similarity coefficients (DSC) of 0.85 (0.77-0.88) and 0.84 (0.82-0.87), respectively. For FLT segmentation, model 1 was superior to model 2, with median (interquartiles) DSCs of 0.63 (0.40-0.78). To purely test the performance of the network to segment FLT, a third model segmented FLT starting from the manually segmented FL, resulting in median (interquartiles) DSCs of 0.99 (0.98-0.99) and 0.85 (0.73-0.94) for patent FL and FLT, respectively. While the ambiguous appearance of FLT on imaging remains a significant limitation for accurate segmentation, our pipeline has the potential to help in segmentation of aortic lumina and thrombosis in uTBAD patients.Clinical relevance- Most predictors of aortic dissection (AD) degeneration are identified through anatomical modeling, which is currently prohibitive in clinical settings due to the timeintense human interaction. False lumen thrombosis, which often develops in patients with type B AD, has proven to show significant prognostic value for predicting late adverse events. Our automated segmentation algorithm offers the potential of personalized treatment for AD patients, leading to an increase in long-term survival.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Deep Learning , Thrombosis , Aortic Dissection/diagnostic imaging , Humans , Retrospective Studies , Thrombosis/diagnostic imaging
13.
Curr Opin Cardiol ; 36(6): 695-703, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34369401

ABSTRACT

PURPOSE OF REVIEW: Discuss foundational concepts for artificial intelligence (AI) and review recent literature on its application to aortic disease. RECENT FINDINGS: Machine learning (ML) techniques are rapidly evolving for the evaluation of aortic disease - broadly categorized as algorithms for aortic segmentation, detection of pathology, and risk stratification. Advances in deep learning, particularly U-Net architectures, have revolutionized segmentation of the aorta and show potential for monitoring the size of aortic aneurysm and characterizing aortic dissection. These algorithms also facilitate application of more complex technologies including analysis of flow dynamics with 4D Flow magnetic resonance imaging (MRI) and computational simulation of fluid dynamics for aortic coarctation. In addition, AI algorithms have been proposed to assist in 'opportunistic' screening from routine imaging exams, including automated aortic calcification score, which has emerged as a strong predictor of cardiovascular risk. Finally, several ML algorithms are being explored for risk stratification of patients with aortic aneurysm and dissection, in addition to prediction of postprocedural complications. SUMMARY: Multiple ML techniques have potential for characterization and risk prediction of aortic aneurysm, dissection, coarctation, and atherosclerotic disease on computed tomography and MRI. This nascent field shows considerable promise with many applications in development and in early preclinical evaluation.


Subject(s)
Aortic Diseases , Artificial Intelligence , Algorithms , Humans , Machine Learning , Magnetic Resonance Imaging
14.
Eur Heart J Digit Health ; 2(2): 311-322, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34223176

ABSTRACT

AIMS: To develop an automated method for bloodpool segmentation and imaging plane re-slicing of cardiac computed tomography (CT) via deep learning (DL) for clinical use in coronary artery disease (CAD) wall motion assessment and reproducible longitudinal imaging. METHODS AND RESULTS: One hundred patients who underwent clinically indicated cardiac CT scans with manually segmented left ventricle (LV) and left atrial (LA) chambers were used for training. For each patient, long-axis (LAX) and short-axis planes were manually defined by an imaging expert. A DL model was trained to predict bloodpool segmentations and imaging planes. Deep learning bloodpool segmentations showed close agreement with manual LV [median Dice: 0.91, Hausdorff distance (HD): 6.18 mm] and LA (Dice: 0.93, HD: 7.35 mm) segmentations and a strong correlation with manual ejection fraction (Pearson r: 0.95 LV, 0.92 LA). Predicted planes had low median location (6.96 mm) and angular orientation (7.96 ° ) errors which were comparable to inter-reader differences (P > 0.71). 84-97% of DL-prescribed LAX planes correctly intersected American Heart Association segments, which was comparable (P > 0.05) to manual slicing. In a test cohort of 144 patients, we evaluated the ability of the DL approach to provide diagnostic imaging planes. Visual scoring by two blinded experts determined ≥94% of DL-predicted planes to be diagnostically adequate. Further, DL-enabled visualization of LV wall motion abnormalities due to CAD and provided reproducible planes upon repeat imaging. CONCLUSION: A volumetric, DL approach provides multiple chamber segmentations and can re-slice the imaging volume along standardized cardiac imaging planes for reproducible wall motion abnormality and functional assessment.

15.
AJR Am J Roentgenol ; 217(6): 1322-1332, 2021 12.
Article in English | MEDLINE | ID: mdl-34076463

ABSTRACT

MRI is an essential diagnostic tool in the anatomic and functional evaluation of cardiovascular disease. In many practices, 2D phase-contrast (2D-PC) MRI has been used for blood flow quantification. Four-dimensional flow MRI is a time-resolved volumetric acquisition that captures the vector field of blood flow along with anatomic images. It also provides a simpler acquisition compared with 2D-PC and facilitates a more accurate and comprehensive hemodynamic assessment. Advancements in accelerated imaging have significantly shortened scanning times for 4D flow MRI while preserving image quality, enabling this technology to transition from the research arena to routine clinical practice. In this article, we review technical optimization based on our more than 10 years of clinical experience with 4D flow MRI. We also present pearls and pitfalls in the practical application of 4D flow MRI, including how to quantify cardiovascular shunts, valvular or vascular stenosis, and valvular regurgitation. As experience increases, and as 4D flow sequences and postprocessing software become more broadly available, 4D flow MRI will likely become an essential component of cardiac imaging in practices involved in the management of congenital and acquired structural heart disease.


Subject(s)
Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Hemodynamics/physiology , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging, Cine/methods , Heart/diagnostic imaging , Heart/physiopathology , Humans , Reproducibility of Results
16.
J Thorac Cardiovasc Surg ; 161(4): 1184-1190.e2, 2021 04.
Article in English | MEDLINE | ID: mdl-31839226

ABSTRACT

BACKGROUND: Patients with medically treated type B aortic dissection (TBAD) remain at significant risk for late adverse events (LAEs). We hypothesize that not only initial morphological features, but also their change over time at follow-up are associated with LAEs. MATERIALS AND METHODS: Baseline and 188 follow-up computed tomography (CT) scans with a median follow-up time of 4 years (range, 10 days to 12.7 years) of 47 patients with acute uncomplicated TBAD were retrospectively reviewed. Morphological features (n = 8) were quantified at baseline and each follow-up. Medical records were reviewed for LAEs, which were defined according to current guidelines. To assess the effects of changes of morphological features over time, the linear mixed effects models were combined with Cox proportional hazards regression for the time-to-event outcome using a joint modeling approach. RESULTS: LAEs occurred in 21 of 47 patients at a median of 6.6 years (95% confidence interval [CI], 5.1-11.2 years). Among the 8 investigated morphological features, the following 3 features showed strong association with LAEs: increase in partial false lumen thrombosis area (hazard ratio [HR], 1.39; 95% CI, 1.18-1.66 per cm2 increase; P < .001), increase of major aortic diameter (HR, 1.24; 95% CI, 1.13-1.37 per mm increase; P < .001), and increase in the circumferential extent of false lumen (HR, 1.05; 95% CI, 1.01-1.10 per degree increase; P < .001). CONCLUSIONS: In medically treated TBAD, increases in aortic diameter, new or increased partial false lumen thrombosis area, and increases of circumferential extent of the false lumen are strongly associated with LAEs.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Thrombosis , Adult , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/epidemiology , Aortic Dissection/pathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/pathology , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/epidemiology , Aortic Aneurysm, Thoracic/pathology , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Thrombosis/pathology , Tomography, X-Ray Computed
17.
AMIA Jt Summits Transl Sci Proc ; 2020: 552-560, 2020.
Article in English | MEDLINE | ID: mdl-32477677

ABSTRACT

A substantial percentage of prostate cancer cases are overdiagnosed and overtreated due to the challenge in deter- mining aggressiveness. Multi-parametric MR is a powerful imaging technique to capture distinct characteristics of prostate lesions that are informative for aggressiveness assessment. However, manual interpretation requires a high level of expertise, is time-consuming, and significant inter-observer variation exists for radiologists. We propose a completely automated approach to assessing pixel-level aggressiveness of prostate cancer in multi-parametric MRI. Our model efficiently combines traditional computer vision and deep learning algorithms, to remove reliance on manual features, prostate segmentation, and prior lesion detection and identified optimal combinations of MR pulse sequences for assessment. Using ADC and DWI, our proposed model achieves ROC-AUC of 0.86 and ROC-AUC of 0.88 for the diagnosis of aggressive and non-aggressive prostate lesions, respectively. In performing pixel-level clas- sification, our model's classifications are easily interpretable and allow clinicians to infer localized analyses of the lesion.

18.
Radiol Cardiothorac Imaging ; 2(3): e190179, 2020 Jun.
Article in English | MEDLINE | ID: mdl-33778582

ABSTRACT

PURPOSE: To develop a segmentation pipeline for segmentation of aortic dissection CT angiograms into true and false lumina on multiplanar reformations (MPRs) perpendicular to the aortic centerline and derive quantitative morphologic features, specifically aortic diameter and true- or false-lumen cross-sectional area. MATERIALS AND METHODS: An automated segmentation pipeline including two convolutional neural network (CNN) segmentation algorithms was developed. The algorithm derives the aortic centerline, generates MPRs orthogonal to the centerline, and segments the true and false lumina. A total of 153 CT angiograms obtained from 45 retrospectively identified patients (mean age, 50 years; range, 22-79 years) were used to train (n = 103), validate (n = 22), and test (n = 28) the CNN pipeline. Accuracy was evaluated by using the Dice similarity coefficient (DSC). Segmentations were then used to derive the maximal diameter of test-set patients and cross-sectional area profiles of the true and false lumina. RESULTS: The segmentation pipeline yielded a mean DSC of 0.873 ± 0.056 for the true lumina and 0.894 ± 0.040 for the false lumina of test-set cases. Automated maximal diameter measurements correlated well with manual measurements (R 2 = 0.95). Profiles of cross-sectional diameter, true-lumen area, and false-lumen area over several follow-up examinations were derived. CONCLUSION: A segmentation pipeline was used to accurately identify true and false lumina on CT angiograms of aortic dissection. These segmentations can be used to obtain diameter and other morphologic parameters for surveillance and risk stratification.Supplemental material is available for this article.© RSNA, 2020.

19.
Curr Treat Options Cardiovasc Med ; 21(11): 69, 2019 Nov 16.
Article in English | MEDLINE | ID: mdl-31732820

ABSTRACT

PURPOSE OF REVIEW: Cardiac MRI (CMR) is the non-invasive test of choice for the assessment of myocarditis. In 2009, the Lake Louise Criteria for the diagnosis of myocarditis using CMR were first released. The decade since that time has vastly improved our understanding of CMR's strengths and limitations. Traditional CMR methods including T2-weighted imaging and late gadolinium enhancement have proven their diagnostic value, but diagnostic performance is dependent on patient presentation. RECENT FINDINGS: Newer parametric mapping techniques have begun to be more comprehensively studied and may improve diagnostic accuracy of CMR in an expanded set of clinical scenarios. Additionally, the prognostic value of CMR has begun to solidify. These advances culminated in an update to the Lake Louise Criteria at the end of 2018. In this review, we discuss the evolution of the diagnostic criteria for CMR in the assessment of myocarditis. We also discuss the pathophysiologic premises behind the use of specific MRI sequences and an up-to-date summary of their individual utility.

20.
Radiol Cardiothorac Imaging ; 1(5): e190057, 2019 Dec.
Article in English | MEDLINE | ID: mdl-33778529

ABSTRACT

PURPOSE: To test the performance of a deep learning (DL) model in predicting atrial fibrillation (AF) at routine nongated chest CT. MATERIALS AND METHODS: A retrospective derivation cohort (mean age, 64 years; 51% female) consisting of 500 consecutive patients who underwent routine chest CT served as the training set for a DL model that was used to measure left atrial volume. The model was then used to measure atrial size for a separate 500-patient validation cohort (mean age, 61 years; 46% female), in which the AF status was determined by performing a chart review. The performance of automated atrial size as a predictor of AF was evaluated by using a receiver operating characteristic analysis. RESULTS: There was good agreement between manual and model-generated segmentation maps by all measures of overlap and surface distance (mean Dice = 0.87, intersection over union = 0.77, Hausdorff distance = 4.36 mm, average symmetric surface distance = 0.96 mm), and agreement was slightly but significantly greater than that between human observers (mean Dice = 0.85 [automated] vs 0.84 [manual]; P = .004). Atrial volume was a good predictor of AF in the validation cohort (area under the receiver operating characteristic curve = 0.768) and was an independent predictor of AF, with an age-adjusted relative risk of 2.9. CONCLUSION: Left atrial volume is an independent predictor of the AF status as measured at routine nongated chest CT. Deep learning is a suitable tool for automated measurement.© RSNA, 2019See also the commentary by de Roos and Tao in this issue.

SELECTION OF CITATIONS
SEARCH DETAIL
...