1.
J Med Ultrason (2001) ; 44(1): 37-50, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27687733

ABSTRACT

BACKGROUND AND PURPOSE: The twinkling sign in B-flow imaging (BFI-TS) has been reported in the literature to increase both specificity and sensitivity compared to the traditional gray-scale imaging. Unfortunately, there has been no conclusive study on the mechanism of this effect. METHODS: In the study presented here, a comparative test on phantoms is introduced, where the variance of a phase estimator is used to quantify the motion amplitude. The statistical inference is employed later to find the dominate factor for the twinkling sign, which is proven by computer simulation. RESULTS: Through the analysis, it is confirmed that the tissue viscoelasticity is closely coupled with the twinkling sign. Moreover, the acoustic radiation force caused by tissue attenuation is found to be the trigger of the twinkling sign. CONCLUSION: Based on these findings, the BFI-TS is interpreted as a tissue movement triggering vibration of microcalcifications particle.


Subject(s)
Calcification, Physiologic , Ultrasonography/methods , Algorithms , Computer Simulation , Elasticity , Factor Analysis, Statistical , Models, Theoretical , Phantoms, Imaging , Sensitivity and Specificity , Ultrasonic Waves , Ultrasonography/instrumentation , Viscosity
2.
Article in English | MEDLINE | ID: mdl-27740477

ABSTRACT

We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.


Subject(s)
Catheters , Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/instrumentation , Echocardiography, Transesophageal/methods , Animals , Equipment Design , Heart Atria/diagnostic imaging , Phantoms, Imaging , Transducers
3.
Article in English | MEDLINE | ID: mdl-23475919

ABSTRACT

Vibro-acoustography (VA) is an ultrasound-based imaging modality that uses radiation force produced by two cofocused ultrasound beams separated by a small frequency difference, Δf, to vibrate tissue at Δf. An acoustic field is created by the object vibration and measured with a nearby hydrophone. This method has recently been implemented on a clinical ultrasound system using 1-D linear-array transducers. In this article, we discuss VA beamforming and image formation using a 1.75-D array transducer. A 1.75-D array transducer has several rows of elements in the elevation direction which can be controlled independently for focusing. The advantage of the 1.75-D array over a 1-D linear-array transducer is that multiple rows of elements can be used for improving elevation focus for imaging formation. Six configurations for subaperture design for the two ultrasound beams necessary for VA imaging were analyzed. The point-spread functions for these different configurations were evaluated using a numerical simulation model. Four of these configurations were then chosen for experimental evaluation with a needle hydrophone as well as for scanning two phantoms. Images were formed by scanning a urethane breast phantom and an ex vivo human prostate. VA imaging using a 1.75-D array transducer offers several advantages over scanning with a linear-array transducer, including improved image resolution and contrast resulting from better elevation focusing of the imaging point-spread function.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Elasticity Imaging Techniques/methods , Transducers , Algorithms , Computer Simulation , Humans , Male , Phantoms, Imaging , Prostate/diagnostic imaging , Ultrasonography, Mammary
4.
Article in English | MEDLINE | ID: mdl-21693399

ABSTRACT

Vibro-acoustography is an ultrasound-based imaging modality that uses two ultrasound beams of slightly different frequencies to produce images based on the acoustic response caused by harmonic ultrasound radiation force excitation at the difference frequency between the two ultrasound frequencies. Vibro-acoustography has demonstrated feasibility and usefulness in imaging of breast and prostate tissue. However, previous studies have been performed either in controlled water tank settings or a prototype breast scanner equipped with a water tank. To make vibro-acoustography more accessible and relevant to clinical use, we report here on the implementation of vibro-acoustography on a General Electric Vivid 7 ultrasound scanner. In this paper, we will describe software and hardware modifications that were performed to make vibro- acoustography functional on this system. We will discuss aperture definition for the two ultrasound beams and beamforming using a linear-array transducer. Experimental results from beam measurements and phantom imaging studies will be shown. The implementation of vibro-acoustography provides a step toward clinical translation of this imaging modality for applications in various organs including breast, prostate, thyroid, kidney, and liver.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Elasticity Imaging Techniques/methods , Software , Equipment Design , Female , Humans , Male , Models, Biological , Phantoms, Imaging , Prostate/diagnostic imaging , Signal Processing, Computer-Assisted , Transducers , Ultrasonography, Mammary