Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Hand Surg Eur Vol ; 49(4): 436-443, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37882683

ABSTRACT

Distraction is a new treatment for trapeziometacarpal joint osteoarthritis. The purpose of this study was to test the efficiency of magnetic distraction using a new internal distractor in cadavers. The distractor consists of two magnets embedded inside titanium capsules that are implanted on either side of the trapeziometacarpal joint with the same poles facing each other, so that the force between the magnets distracts the joint. Intra-articular forces were recorded pre-implantation, immediately after implantation and again 10 minutes later. We also studied the changes in the forces before and after the procedure in different thumb positions. Our findings show that the trapeziometacarpal joint could be offloaded in all the studied trapeziometacarpal positions.


Subject(s)
Osteoarthritis , Humans , Thumb , Cadaver , Magnetic Phenomena
2.
Sci Rep ; 13(1): 18387, 2023 10 26.
Article in English | MEDLINE | ID: mdl-37884628

ABSTRACT

In 2018, during our first clinical study on the kineticomyographic (KMG)-controlled bionic hand, we implanted three magnetic tags inside the musculotendinous junction of three paired extensor-flexor transferred tendons. However, the post-operative tissue adhesions affected the independent movements of the implanted tags and consequently the distinct patterns of the obtained signals. To overcome this issue, we modified our surgical procedure from a one-stage tendon transfer to a two-stage. During the first surgery, we created three tunnels using silicon rods for the smooth tendon gliding. In the second stage, we transferred the same three pairs of the forearm agonist-antagonist tendons through the tunnels and implanted the magnetic tags inside the musculotendinous junction. Compared to our prior clinical investigation, fluoroscopy and ultrasound evaluations revealed that the surgical modification in the current study yielded more pronounced independent movements in two specific magnetic tags associated with fingers (maximum 5.7 mm in the first trial vs. 28 mm in the recent trial with grasp and release) and thumb (maximum 3.2 mm in the first trial vs. 9 mm in the current trial with thumb flexion-extension). Furthermore, we observed that utilizing the flexor digitorum superficialis (FDS) tendons for the flexor component in finger and thumb tendon transfer resulted in more independent movements of the implanted tags, compared with the flexor digitorum profundus (FDP) in the prior research. This study can help us plan for our future five-channel bionic limb design by identifying the gestures with the most significant independent tag displacement.


Subject(s)
Bionics , Tendons , Tendons/surgery , Fingers , Tendon Transfer/methods , Muscle, Skeletal
SELECTION OF CITATIONS
SEARCH DETAIL
...