Mater Sci Eng C Mater Biol Appl ; 49: 769-775, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25687007

ABSTRACT

In this study, an electrochemical sensor was fabricated based on gold nanoparticles/ ethylenediamine/ multi-wall carbon-nanotubes modified gold electrode (AuNPs/en/MWCNTs/AuE) for determination of valrubicin in biological samples. Valrubicin was effectively accumulated on the surface of AuNPs/en/MWCNTs/AuE and produced a pair of redox peaks at around 0.662 and 0.578V (vs. Ag/AgCl) in citrate buffer (pH4.0). The electrochemical parameters including pH, buffer, ionic strength, scan rate and size of AuNPs have been optimized. There was a good linear correlation between cathodic peak current and concentration of valrubicin in the range of 0.5 to 80.0µmolL(-1) with the detection limit of 0.018µmolL(-1) in citrate buffer (pH4.0) and 0.1molL(-1) KCl. Finally, the constructed sensor was successfully applied for determination of valrubicin in human urine and blood serum. In further studies, the different sequences of single stranded DNA probes have been immobilized on the surface of AuNPs decorated on MWCNTs to study the interaction of oligonucleotides with valrubicin.


Subject(s)
Doxorubicin/analogs & derivatives , Gold/chemistry , Metal Nanoparticles/chemistry , Nanotubes, Carbon/chemistry , Biosensing Techniques/methods , DNA/chemistry , Doxorubicin/chemistry , Electrochemical Techniques/methods , Electrodes , Ethylenediamines/chemistry , Humans , Hydrogen-Ion Concentration , Limit of Detection , Osmolar Concentration , Oxidation-Reduction , Particle Size , Serum/chemistry , Urine/chemistry
2.
Anal Chim Acta ; 580(2): 236-43, 2006 Nov 24.
Article in English | MEDLINE | ID: mdl-17723779

ABSTRACT

A sequential method is proposed for the determination of tryptophane and histidine by adsorptive cathodic stripping voltammetry using standard addition and H-point standard addition method (HPSAM). The complexes of copper(II) with the amino acids were accumulated onto the surface of a hanging mercury drop electrode for 60s. Then the preconcentrated complexes were reduced by square wave voltammetry and the peak currents were measured. The effect of various parameters such as pH, concentration of copper, accumulation potential, accumulation time and scan rate on the sensitivity were studied by one-at-a time and artificial neural network. Under the optimized conditions, the peak currents at about +0.05 to -0.30 V is proportional to the concentration of tryptophan and histidine over the concentration ranges of 5-220 and 100-1200 nM, respectively. Optimization of the parameters by one-at-a time showed that at accumulation potential of 0.10 V (versus Ag/AgCl reference electrode) the peak current is proportional only to the concentration of tryptophan and histidine does not have any contribution to the current. The optimization results by artificial neural network showed that at accumulation potential of -0.06 V (versus Ag/AgCl) the peak current is proportional to the both concentrations of tryptophan and histidine. Therefore, the method of H-point standard addition has been used for resolving overlap voltamograms for determination of histidine in the present of tryptophane. The method was successfully applied to the determination of tryptophan and histidine in synthetic and real samples.

3.
Talanta ; 63(2): 359-64, 2004 May 28.
Article in English | MEDLINE | ID: mdl-18969440

ABSTRACT

The applicability of H-point standard addition method (HPSAM) to the resolving of overlapping differential pulse anodic stripping voltammetric peaks corresponding to the oxidation of lead and tin is verified. The results show that the H-point standard addition method is suitable for the simultaneous determination of lead and tin in aqueous media. The results of applying the H-point standard addition method showed that Sn(2+) and Pb(2+) could be determined simultaneously with the concentration ratios of Sn(2+) to Pb(2+) varying from 1:5 to 10:1 in the mixed sample. The proposed method has been successfully applied to the simultaneous determination of lead in the presence of tin in some synthetic samples. Moreover, the applicability of the method was demonstrated by the recovery of lead in a canned soft drink sample.