Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
J Med Imaging Radiat Sci ; 55(2): 281-288, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38609834

ABSTRACT

PURPOSE/OBJECTIVE: To determine the impact of a MR-based contouring atlas for male pelvis radiotherapy delineation on inter-observer variation to support radiographer led real-time magnetic resonance image guided adaptive radiotherapy (MRgART). MATERIAL/METHODS: Eight RTTs contoured 25 MR images in the Monaco treatment planning system (Monaco 5.40.01), from 5 patients. The prostate, seminal vesicles, bladder, and rectum were delineated before and after the introduction of an atlas developed through multi-disciplinary consensus. Inter-observer contour variations (volume), time to contour and observer contouring confidence were determined at both time-points using a 5-point Likert scale. Descriptive statistics were used to analyse both continuous and categorical variables. Dice similarity coefficient (DSC), Dice-Jaccard coefficient (DJC) and Hausdorff distance were used to calculate similarity between observers. RESULTS: Although variation in volume definition decreased for all structures among all observers post intervention, the change was not statistically significant. DSC and DJC measurements remained consistent following the introduction of the atlas for all observers. The highest similarity was found in the bladder and prostate whilst the lowest was the seminal vesicles. The mean contouring time for all observers was reduced by 50% following the introduction of the atlas (53 to 27 minutes, p=0.01). For all structures across all observers, the mean contouring confidence increased significantly from 2.3 to 3.5 out of 5 (p=0.02). CONCLUSION: Although no significant improvements were observed in contour variation amongst observers, the introduction of the consensus-based contouring atlas improved contouring confidence and speed; key factors for a real-time RTT-led MRgART.


Subject(s)
Magnetic Resonance Imaging , Observer Variation , Prostatic Neoplasms , Radiotherapy, Image-Guided , Humans , Male , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Radiotherapy, Image-Guided/methods , Pelvis/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Atlases as Topic , Prostate/diagnostic imaging
2.
Phys Med Biol ; 68(2)2023 01 11.
Article in English | MEDLINE | ID: mdl-36549006

ABSTRACT

Objective.Patients treated for cervical cancer exhibit large inter and intra-fraction anatomical changes. The Unity MR-Linac (MRL) can image these patients with MR prior to and during treatment which enables daily plan adaptation. However, the MRL has a limited treatment field in the sup/inf direction of 22 cm which can restrict the treatment of patients who require longer treatment fields. Here we explore potential adaptive workflows in combination with a dual isocentre approach, to widen the range of cervix patients that can benefit from this treatment.Approach.Ten cervical cancer patients were retrospectively planned with a dual isocentre technique to deliver 45 Gy in 25 fractions. 5 node-negative and 5 node-positive patients were planned using the EMBRACE II protocol. A 2 cm overlap region between the two isocentres was positioned entirely in the nodal region. A treatment workflow was simulated to account for inter-fraction anatomical change. Isocentre shifts of 3 and 6 mm were applied to investigate the effect of intra-fraction motion.Main results.Dual isocentre adapted plans ensured significantly better coverage than non-adapted (recalculated) plans with a larger benefit seen for the node-negative cases. The difference to the reference plan for the V4275 cGy to the ITV was -0.8 cGy and -8.2 cGy for the adapted and recalculated plans respectively. Movements superiorly did not affect the coverage of the ITV by more than 1%, but shifting it inferiorly caused the ITV coverage on the plan to reduce by ∼2.4% per mm.Significance.A dual isocentre technique for cervical cancer treatments and adaptive workflows have been demonstrated to recover the required plan quality for inter-fraction changes. This illustrates the feasibility of a dual isocentre technique for the MRL.


Subject(s)
Uterine Cervical Neoplasms , Female , Humans , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Feasibility Studies
3.
J Med Imaging Radiat Sci ; 53(3): 362-373, 2022 09.
Article in English | MEDLINE | ID: mdl-35850925

ABSTRACT

BACKGROUND/PURPOSE: This work evaluated the suitability of MR derived sequences for use in online adaptive RT workflows on a 1.5 Tesla (T) MR-Linear Accelerator (MR Linac). MATERIALS/METHODS: Non-patient volunteers were recruited to an ethics approved MR Linac imaging study. Participants attended 1-3 imaging sessions in which a combination of DIXON, 2D and 3D volumetric T1 and T2 weighted images were acquired axially, with volunteers positioned using immobilisation devices typical for radiotherapy to the anatomical region being scanned. Images from each session were appraised by three independent reviewers to determine optimal sequences over six anatomical regions: head and neck, female and male pelvis, thorax (lung), thorax (breast/chest wall) and abdomen. Site specific anatomical structures were graded by the perceived ability to accurately contour a typical organ at risk. Each structure was independently graded on a 4-point Likert scale as 'Very Clear', 'Clear', 'Unclear' or 'Not visible' by observers, consisting of radiographers (therapeutic and diagnostic) and clinicians. RESULTS: From July 2019 to September 2019, 18 non-patient volunteers underwent 24 imaging sessions in the following anatomical regions: head and neck (n=3), male pelvis (n=4), female pelvis (n=5), lung/oesophagus (n=5) abdomen (n=4) and chest wall/breast (n=3). T2 sequences were the most preferred for perceived ability to contour anatomy in both male and female pelvis. For all other sites T1 weighted DIXON sequences were most favourable. CONCLUSION: This study has determined the preferential sequence selection for organ visualisation, as a pre-requisite to our institution adopting MR-guided radiotherapy for a more diverse range of disease sites.


Subject(s)
Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Female , Humans , Magnetic Resonance Imaging , Male , Particle Accelerators , Radiotherapy Planning, Computer-Assisted
4.
Med Phys ; 49(1): 510-520, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34741308

ABSTRACT

PURPOSE: Gadolinium-based contrast agents (GBCAs) may add value to magnetic resonance (MR)-only radiotherapy (RT) workflows including on hybrid machines such as the MR Linac. The impact of GBCAs on RT dose distributions however have not been well studied. This work used retrospective GBCA-enhanced datasets to assess the dosimetric effect of GBCAs on head and neck plans. METHODS: Ten patients with oropharyngeal squamous cell carcinoma receiving RT from November 2018 to April 2020 were included in this study. RT planning included contrast-enhanced computed tomography (CT) and MR scans. A contrast agent "contour" was defined by delineating GBCA-enhanced regions using an agreed window/level threshold, transferred to the planning CT and given a standardized electron density (ED) of 1.149 in the Monaco treatment planning system (Elekta AB). Four plans were per patient calculated and compared using two methods: (1) optimized without contrast (Plan A) then recalculated with ED (Plan B), and (2) optimized with contrast ED (Plan C) then without (Plan D). For target parameters minimum and maximum doses to 1cc of PTVs, D95 values, and percent dose differences were calculated. Dose differences for organs-at-risk (OARs) were calculated as a percentage of the clinical tolerance value. For the purposes of this study, ±2% over the whole treatment course was considered to be a clinically acceptable dose deviation. Wilcoxon-signed rank tests were used to determine any dose differences within and between the two methods of optimization and recalculation (p < 0.05). Pearson's correlations were used to establish the relationship between gadolinium uptake volume in a structure (i.e., proportion of structure covered by a density override) and the resulting dose difference. RESULTS: The median percent dose differences for key reportable dosimetric parameters between non-contrast and simulated contrast plans were <1.2% over all fractions over all patients for reportable target parameters (mean 0.34%, range 0.22%-1.02%). The percent dose differences for maximum dose to 1cc of both PTV1 and PTV2 were significantly different after application of density override (p < 0.05) but only in method 2 (Plan C vs. Plan D). For D95 PTV1, there was a statistically significant effect of density override (p < 0.01), however only in method 1 (Plan A vs. Plan B). There were no significant differences between calculation methods of the impact of contrast in most target parameters with the exception of D95 PTV1 (p < 0.01) and for D95 PTV2 (p < 0.05). The median percent dose differences for reportable OAR parameters as a percentage of clinical planning tolerances were <2.0% over a full treatment course (mean 0.65%, range 0.27%-1.62%). There were no significant differences in dose to OARs within or between methods for contrast impact assessment. CONCLUSIONS: Dose differences to targets and OARs in oropharyngeal cancer treatment due to the presence of GBCA were minimal, and this work suggests that prospective in vivo evaluations of impact may not be necessary in this clinical site. Accounting for GBCAs may not be needed in daily adaptive workflows on the MR Linac.


Subject(s)
Gadolinium , Radiotherapy, Intensity-Modulated , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Organs at Risk , Prospective Studies , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
5.
J Med Imaging Radiat Sci ; 52(4S): S24-S31, 2021 12.
Article in English | MEDLINE | ID: mdl-34229985

ABSTRACT

INTRODUCTION/BACKGROUND: Magnetic Resonance Imaging (MRI) is used in radiotherapy planning, and increasingly in on-treatment guidance. The potential for the MR environment to be hazardous, without stringent safe working practices, is real. Guidance suggests all workers in MRI undergo annual safety training. To facilitate a tangible MR safety program, an electronic learning module was created and evaluated. METHODS: An existing presentation, normally delivered face-to-face, was modified and questions added to test knowledge. The module was delivered and feedback collected, together with answers to the questions, over three phases to ensure deliverability, clarity, and robustness. These comprised an initial pilot phase for non-MR personnel, an evaluation phase for staff renewing annual MR safety training, and finally for new therapeutic radiographer graduates, a test-retest methodology. RESULTS: Seven participants took part in the initial pilot phase, followed by thirty-one in the evaluation phase. Participants included radiographers (therapeutic and diagnostic), play specialists, clinical oncologists and anaesthetists, physicists and nursing staff. Within the evaluation group, 74.2% achieved a score >80%. Incorrect responses were principally related to questions regarding expected levels of responsibility and working practices, rather than the physics of high magnetic field strengths. The test-retest phase (n = 5) followed. Mean scores prior to learning were 59%, improving to 79% following learning, with the weakest sections mirroring those highlighted within the evaluation phase. DISCUSSION: Transferring MR safety training into an electronic format has provided a standardised, tangible tool that provides evidence of compliance with recommended guidance. CONCLUSIONS: This work illustrates the transition of MR safety learning for radiotherapy staff from passive presentation, to an interactive teaching methodology. The e-learning module has now been implemented within the department.


Subject(s)
Magnetic Resonance Imaging , Radiation Oncology , Allied Health Personnel , Electronics , Humans , Learning
6.
Radiother Oncol ; 159: 112-118, 2021 06.
Article in English | MEDLINE | ID: mdl-33775713

ABSTRACT

PURPOSE: This study compared MRI to CBCT for the identification and registration of lymph nodes (LN) in patients with locally advanced (LA)-NSCLC, to assess the suitability of targeting LNs in future MR-image guided radiotherapy (MRgRT) workflows. METHOD: Radiotherapy radiographers carried out Visual Grading Analysis (VGA) assessment of image quality, LN registration and graded their confidence in registration for each of the 24 LNs on CBCT and two MR sequences, MR1 (T2w Turbo Spin Echo) and MR2 (T1w DIXON water only image). RESULTS: Pre-registration image quality assessment revealed MR1 and MR2 as significantly superior to CBCT in terms of image quality (p ≤ 0.01). No significant differences were noted in interobserver variability for LN registration between CBCT, MR1 and MR2. Observers were more confident in their MR registrations compared to their CBCT based LN registrations (p ≤ 0.02). SUMMARY: Interobserver setup correction variability was not found to be significantly different between CBCT and MR. Image quality and registration confidence were found to be superior for MRI sequences. This is a promising step towards MR-guided radiotherapy for the treatment of LA-NSCLC.


Subject(s)
Lung Neoplasms , Radiotherapy, Image-Guided , Spiral Cone-Beam Computed Tomography , Cone-Beam Computed Tomography , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Lymph Nodes/diagnostic imaging , Magnetic Resonance Imaging , Radiotherapy Planning, Computer-Assisted
7.
J Med Imaging Radiat Sci ; 52(1): 147-151, 2021 03.
Article in English | MEDLINE | ID: mdl-33342695

ABSTRACT

INTRODUCTION: The integration of magnetic resonance (MR) imaging into radiotherapy through new technology, including the MR -linear accelerator (MRL), has allowed further advancements into image guided radiotherapy (IGRT). Better soft tissue visualisation has led to some unusual findings. CASE AND OUTCOMES: A patient with T1c N0 M0 prostate adenocarcinoma received 60Gy in 20# radiotherapy on the MRL. Radiotherapy planning (RTP) scans were completed on both CT and MR (using T2 and T1 weighted three-dimensional turbo spin echo sequences, reconstructed transaxially (TRA). The MR scans revealed atypical oedema in the right peripheral zone, visualised on T2-weighted (T2w) MR Images as an accumulation of high signal intensity fluid. Daily MRL treatment includes a (T2w 3D Tra) sequence with which oedematous changes could be monitored. The images demonstrated an increase in oedematous volume over fractions 1-10 causing the prostate contour variations from the initial planning scans. Despite the prostate volume variations PTV coverage was never breached and dose constraints were always met for both PTV and surrounding organs at risk (OAR's), excluding the need for oncologist input. A single Therapeutic Radiographer (RTT) experienced in MRL delivery, contoured the prostate and oedematous volumes on the radiotherapy plan (RTP) MR and all on-treatment MR images to assess change over the radiotherapy course. The initial volumes were 53.4 cm3 and 8.3 cm3 for the prostate plus oedema and oedema alone respectively. The most significant change was seen for both the prostate and oedema on fraction nine (68.0 cm3 and 10.1 cm3, respectively). Reductions were noted after this with final (fraction 20) volumes of 55.2 cm3 and 0.58 cm3 respectively. DISCUSSION: The ability to visualise prostatic oedema was new to the radiotherapy treatment team due to better soft tissue visualisation than standard radiotherapy. The results from contouring the prostate and oedema volumes confirmed radiographer observations and demonstrated how oedema impacted the overall prostate volume by quantifying the oedematous variations over time. The changes in oedema volume are presumed to be in response to radiotherapy. CONCLUSION: Further adaptive radiotherapy work-flow developments, utilising an "Adapt to Shape" model will allow real-time re-contouring of the prostate to ensure tumour control is not compromised. Further work investigating the frequency and impact of oedemotous changes to external beam prostate patients will help to inform practice.


Subject(s)
Edema/diagnostic imaging , Magnetic Resonance Imaging/methods , Radiotherapy, Image-Guided/methods , Aged , Humans , Male , Particle Accelerators , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage , Tumor Burden
8.
J Med Imaging Radiat Sci ; 51(3): 364-372, 2020 09.
Article in English | MEDLINE | ID: mdl-32600981

ABSTRACT

INTRODUCTION: Magnetic resonance-guided adaptive radiotherapy (MRgART) has the potential to improve treatment processes and outcomes for a variety of tumour sites; however, it requires significant clinical resources. Magnetic resonance linear accelerator (MR-linac) treatments require a daily multidisciplinary presence for delivery. To facilitate sustainable MRgART models, agreed protocols facilitating therapeutic radiographer (RTT)-led delivery must be developed to establish a service similar to conventional image-guided radiotherapy (IGRT). This work provides a clinical perspective on the implementation of a protocol-driven 'clinician-lite' MRgART workflow at one institution. METHODS: To identify knowledge, skills, and competence required at each step in the MRgART workflow, an interdisciplinary informal survey and needs assessment were undertaken to identify additional or enhanced skills required for MRgART, over and above those required for conventional cone-beam computed tomography-based IGRT. The MRgART pathway was critically evaluated by relevant professionals to encourage multidisciplinary input and discussion, allowing an iterative development of the RTT-led workflow. Starting with the simplest online adaptation strategy, consisting of a virtual couch shift and online replanning, clear guidelines were established for the delivery of radical prostate radiotherapy with a reduction in staff numbers present. RESULTS: The MRgART-specific skills identified included MRI safety and screening, MR image acquisition, MRI-based anatomy, multimodality image interpretation and registration, and treatment plan evaluation. These skills were developed in RTTs via tutorials, workshops, focussed self-directed reading, teaching of colleagues, and end-to-end workflow testing. After initial treatments and discussions, roles and responsibilities of the three professional groups (clinicians, RTTs, and physicists) have evolved to achieve a 'clinician-lite' workflow for simple radical prostate treatments. DISCUSSION: Through applying a definitive framework and establishing agreed threshold and action levels for action within anticipated treatment scenarios similar to those in cone-beam computed tomography-based IGRT, we have implemented a 'clinician-lite' workflow for simple adaptive treatments on the MR-linac. The responsibility for online plan evaluation and approval now rests with physicists and RTTs to streamline MRgART. Early evaluation of the framework after treatment of 10 patients has required minimal online clinician input (1.5% of 200 fractions delivered). CONCLUSION: A 'clinician-lite' prostate treatment workflow has been successfully introduced on the MR-linac at our institution and will serve as a model for other tumour sites, using more complex adaptive strategies. Early indications are that this framework has the potential to improve patient throughput and efficiency. Further identification and validation of roles and responsibilities such as online contouring, and more interactive online planning, will facilitate RTTs to fully lead in the online workflow as adaptive radiotherapy becomes ever more complex.


Subject(s)
Clinical Protocols , Magnetic Resonance Imaging , Prostatic Neoplasms/radiotherapy , Radiology Department, Hospital/organization & administration , Radiotherapy, Image-Guided/methods , Clinical Competence , Cone-Beam Computed Tomography , Efficiency, Organizational , Humans , Interdisciplinary Communication , Male , Personnel Staffing and Scheduling , Prostatic Neoplasms/diagnostic imaging , Workflow
9.
Br J Radiol ; 93(1112): 20200169, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32543946

ABSTRACT

OBJECTIVES: The aim of this study was to assess the consistency of therapy radiographers performing image registration using cone beam computed tomography (CBCT)-CT, magnetic resonance (MR)-CT, and MR-MR image guidance for cervix cancer radiotherapy and to assess that MR-based image guidance is not inferior to CBCT standard practice. METHODS: 10 patients receiving cervix radiation therapy underwent daily CBCT guidance and magnetic resonance (MR) imaging weekly during treatment. Offline registration of each MR image, and corresponding CBCT, to planning CT was performed by five radiographers. MR images were also registered to the earliest MR interobserver variation was assessed using modified Bland-Altman analysis with clinically acceptable 95% limits of agreement (LoA) defined as ±5.0 mm. RESULTS: 30 CBCT-CT, 30 MR-CT and 20 MR-MR registrations were performed by each observer. Registration variations between CBCT-CT and MR-CT were minor and both strategies resulted in 95% LoA over the clinical threshold in the anteroposterior direction (CBCT-CT ±5.8 mm, MR-CT ±5.4 mm). MR-MR registrations achieved a significantly improved 95% LoA in the anteroposterior direction (±4.3 mm). All strategies demonstrated similar results in lateral and longitudinal directions. CONCLUSION: The magnitude of interobserver variations between CBCT-CT and MR-CT were similar, confirming that MR-CT radiotherapy workflows are comparable to CBCT-CT image-guided radiotherapy. Our results suggest MR-MR radiotherapy workflows may be a superior registration strategy. ADVANCES IN KNOWLEDGE: This is the first publication quantifying interobserver registration of multimodality image registration strategies for cervix radical radiotherapy patients.


Subject(s)
Cone-Beam Computed Tomography/methods , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Observer Variation , Radiotherapy, Image-Guided/methods , Uterine Cervical Neoplasms/radiotherapy , Adult , Aged , Cervix Uteri/diagnostic imaging , Female , Humans , Middle Aged , Uterine Cervical Neoplasms/diagnostic imaging
SELECTION OF CITATIONS