1.
Sci Rep ; 11(1): 15533, 2021 07 30.
Article in English | MEDLINE | ID: mdl-34330936

ABSTRACT

Hydrogen-grain-boundaries interactions and their role in intergranular fracture are well accepted as one of the key features in understanding hydrogen embrittlement in a large variety of common engineer situations. These interactions implicate some fundamental processes classified as segregation, trapping and diffusion of the solute which can be studied as a function of grain boundary configuration. In the present study, we carried out an extensive analysis of four grain-boundaries based on the complementary of atomistic calculations and experimental data. We demonstrate that elastic deformation has an important contribution on the segregation energy which cannot be simply reduced to a volume change and need to consider the deviatoric part of strain. Additionally, some significant configurations of the segregation energy depend on the long-range elastic distortion and allows to rationalize the elastic contribution in three terms. By investigating the different energy barriers involved to reach all the segregation sites, the antagonist impact of grain boundaries on hydrogen diffusion and trapping process was elucidated. The segregation energy and migration energy are two fundamental parameters in order to classify the grain-boundaries as a trapping location or short circuit for diffusion.

2.
Med Phys ; 39(4): 1925-35, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22482614

ABSTRACT

PURPOSE: In gynecological radiotherapy with high dose rate (HDR)(192)Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. METHODS: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron(192)Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. RESULTS: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. CONCLUSIONS: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.


Subject(s)
Brachytherapy/instrumentation , Genital Neoplasms, Female/radiotherapy , Radiometry/instrumentation , Equipment Design , Equipment Failure Analysis , Feasibility Studies , Female , Humans , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
3.
Radiat Prot Dosimetry ; 138(4): 295-309, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19933696

ABSTRACT

Radiation measurements of surface and deep organ doses were performed aboard the International Space Station, for the period of January 2006 to April 2007, using a MOSFET dosimetry system combined with the Matroshka-R spherical phantom. The averaged internal and surface dose rates are found to be 0.19 and 0.29 mGy d(-1), respectively. The levels of radiation dose to blood-forming organs (BFO) and to surface organs are compared with recommended safe limits. The maximum measured BFO dose has an average dose rate of 0.23 mGy d(-1) (84 mGy y(-1)), corresponding to 44 % of the recommended annual limit of 0.5 Sv, for a space radiation quality factor of 2.6. The annual surface dose is found to be higher at 126 mGy, corresponding to 16 % of the eye dose limit and to 11 % of the skin dose limit. Doses calculated using the Spenvis software showed deviations of up to 37 % from measurements.


Subject(s)
Eye/radiation effects , Phantoms, Imaging , Radiometry/instrumentation , Skin/radiation effects , Space Flight/instrumentation , Body Burden , Humans , Occupational Exposure , Radiometry/methods , Space Flight/methods
4.
Med Phys ; 36(5): 1672-9, 2009 May.
Article in English | MEDLINE | ID: mdl-19544784

ABSTRACT

A prototype of a new 4D in vivo dosimetry system capable of simultaneous real-time position monitoring and dose measurement has been developed. The radiation positioning system (RADPOS) is controlled by a computer and combines two technologies: MOSFET radiation detector coupled with an electromagnetic positioning device. Special software has been developed that allows sampling position and dose either manually or automatically in user-defined time intervals. Preliminary tests of the new device include a dosimetric evaluation of the detector in 60Co, 6 MV, and 18 MV beams and measurements of spatial position stability and accuracy. In addition, the effect of metals and other materials on the performance of the positioning system has been investigated. Results show that the RADPOS system can measure in-air dose profiles that agree, on average, within 3%-5% of diode measurements for the energies tested. The response of the detector is isotropic within 1.6% (1 SD) with a maximum deviation of +/- 4.0% over 360 degrees. The maximum variation in the calibration coefficient over field sizes from 6 x 6 to 25 x 25 cm2 was 2.3% for RADPOS probe with the high sensitivity MOSFET and 4.6% for the probe with the standard sensitivity MOSFET. Of the materials tested, only aluminum, lead, and brass caused shifts in the RADPOS read position. The magnitude of the shift varied between materials and size of the material sample. Nonmagnetic stainless steel (Grade 304) caused a distortion of less than 2 mm when placed within 10 mm of the detector; therefore, it can provide a reasonable alternative to other metals if required. The results of the preliminary tests indicate that the device can be used for in vivo dosimetry in 60Co and high-energy beams from linear accelerators.


Subject(s)
Imaging, Three-Dimensional/instrumentation , Magnetics/instrumentation , Radiometry/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Semiconductors , Sensitivity and Specificity
5.
Phys Med Biol ; 49(17): 4031-48, 2004 Sep 07.
Article in English | MEDLINE | ID: mdl-15470921

ABSTRACT

The commercially available microMOSFET dosimeter was characterized for its dosimetric properties in radiotherapy treatments. The MOSFET exhibited excellent correlation with the dose and was linear in the range of 5-500 cGy. No measurable effect in response was observed in the temperature range of 20-40 degrees C. No significant change in response was observed by changing the dose rate between 100 and 600 monitor units (MU) min(-1) or change in the dose per pulse. A 3% post-irradiation fading was observed within the first 5 h of exposure and thereafter it remained stable up to 60 h. A uniform energy response was observed in the therapy range between 4 MV and 18 MV. However, below 0.6 MeV (Cs-132), the MOSFET response increased with the decrease in energy. The MOSFET also had a uniform dose response in 6-20 MeV electron beams. The directional dependence of MOSFET was within +/-2% for all the energies studied. The inherent build-up of the MOSFET was evaluated dosimetrically and found to have varying water equivalent thickness, depending on the energy and the side of the beam entry. At depth, a single calibration factor obtained by averaging the MOSFET response over different field sizes, energies, orientation and depths reproduced the ion chamber measured dose to within 5%. The stereotactic and the penumbral measurements demonstrated that the MOSFET could be used in a high gradient field such as IMRT. The study showed that the microMOSFET dosimeter could be used as an in vivo dosimeter to verify the dose delivery to the patient to within +/-5%.


Subject(s)
Radiometry/methods , Radiotherapy, Conformal/methods , Radiotherapy/methods , Algorithms , Calibration , Dose-Response Relationship, Radiation , Humans , Phantoms, Imaging , Photons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Software , Time Factors , Water