Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
N Engl J Med ; 390(5): 409-420, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38294973

ABSTRACT

BACKGROUND: Studies evaluating surgical-site infection have had conflicting results with respect to the use of alcohol solutions containing iodine povacrylex or chlorhexidine gluconate as skin antisepsis before surgery to repair a fractured limb (i.e., an extremity fracture). METHODS: In a cluster-randomized, crossover trial at 25 hospitals in the United States and Canada, we randomly assigned hospitals to use a solution of 0.7% iodine povacrylex in 74% isopropyl alcohol (iodine group) or 2% chlorhexidine gluconate in 70% isopropyl alcohol (chlorhexidine group) as preoperative antisepsis for surgical procedures to repair extremity fractures. Every 2 months, the hospitals alternated interventions. Separate populations of patients with either open or closed fractures were enrolled and included in the analysis. The primary outcome was surgical-site infection, which included superficial incisional infection within 30 days or deep incisional or organ-space infection within 90 days. The secondary outcome was unplanned reoperation for fracture-healing complications. RESULTS: A total of 6785 patients with a closed fracture and 1700 patients with an open fracture were included in the trial. In the closed-fracture population, surgical-site infection occurred in 77 patients (2.4%) in the iodine group and in 108 patients (3.3%) in the chlorhexidine group (odds ratio, 0.74; 95% confidence interval [CI], 0.55 to 1.00; P = 0.049). In the open-fracture population, surgical-site infection occurred in 54 patients (6.5%) in the iodine group and in 60 patients (7.3%) in the chlorhexidine group (odd ratio, 0.86; 95% CI, 0.58 to 1.27; P = 0.45). The frequencies of unplanned reoperation, 1-year outcomes, and serious adverse events were similar in the two groups. CONCLUSIONS: Among patients with closed extremity fractures, skin antisepsis with iodine povacrylex in alcohol resulted in fewer surgical-site infections than antisepsis with chlorhexidine gluconate in alcohol. In patients with open fractures, the results were similar in the two groups. (Funded by the Patient-Centered Outcomes Research Institute and the Canadian Institutes of Health Research; PREPARE ClinicalTrials.gov number, NCT03523962.).


Subject(s)
Anti-Infective Agents, Local , Chlorhexidine , Fracture Fixation , Fractures, Bone , Iodine , Surgical Wound Infection , Humans , 2-Propanol/administration & dosage , 2-Propanol/adverse effects , 2-Propanol/therapeutic use , Anti-Infective Agents, Local/administration & dosage , Anti-Infective Agents, Local/adverse effects , Anti-Infective Agents, Local/therapeutic use , Antisepsis/methods , Canada , Chlorhexidine/administration & dosage , Chlorhexidine/adverse effects , Chlorhexidine/therapeutic use , Ethanol , Extremities/injuries , Extremities/microbiology , Extremities/surgery , Iodine/administration & dosage , Iodine/adverse effects , Iodine/therapeutic use , Preoperative Care/adverse effects , Preoperative Care/methods , Skin/microbiology , Surgical Wound Infection/etiology , Surgical Wound Infection/prevention & control , Fractures, Bone/surgery , Cross-Over Studies , United States
2.
J Orthop Trauma ; 38(1): 36-41, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37684010

ABSTRACT

OBJECTIVES: Dual implants for distal femur periprosthetic fractures is a growing area of interest for these challenging fractures with dual plating (DP) emerging as a viable construct for these injuries. In the current study, an experience with DP constructs is described. DESIGN: Retrospective case series with comparison group. SETTING: Level 1 academic trauma center. PATIENT SELECTION CRITERIA: Adults >50 years old sustaining comminuted OTA/AO 33-A2 or 33-A3 DFPF treated with either DP or a single distal femur locking plating (DFLP). Patients with simple 33-A1 fractures were excluded. Prior to 2018, patients underwent DFLP after which the treatment of choice became DP. OUTCOME MEASURES AND COMPARISONS: Reoperation rate, alignment, and complications. RESULTS: 34 patients treated with DFLP and 38 with DP met inclusion and follow up criteria. Average follow up was 18.2 ± 13.8 months in the DFLP group and 19.8 ± 16.1 months in the DP group ( P = 0.339). The average patient age in the DFLP group was 74.8 ± 7.3 years compared to 75.9 ± 11.3 years in the DP group. There were no statistical differences in demographics, fracture morphology, loss of reduction, or reoperation for any cause ( P >.05). DP patients were more likely to be weight bearing in the twelve-week postoperative period ( P <0.001) and return to their baseline ambulatory status ( P = 0.004) compared to DFLP patients. CONCLUSIONS: Dual plating of distal femoral periprosthetic fractures maintained coronal alignment with a low reoperation rate even with immediate weight bearing and these patients regained baseline level of ambulation more reliably as compared to patients treated with a single distal femoral locking plate. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Femoral Fractures, Distal , Femoral Fractures , Periprosthetic Fractures , Adult , Humans , Aged , Aged, 80 and over , Middle Aged , Retrospective Studies , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Femoral Fractures/surgery , Femoral Fractures/etiology , Fracture Fixation, Internal/adverse effects , Bone Plates , Femur , Treatment Outcome
3.
J Surg Orthop Adv ; 32(4): 259-262, 2023.
Article in English | MEDLINE | ID: mdl-38551235

ABSTRACT

Distal femoral skeletal traction is a common procedure for the stabilization of fractures of the pelvis, acetabulum, and femur following trauma. Femoral traction pins are traditionally inserted via medial-to-lateral (MTL) entry to accurately direct the pin away from the medial neurovascular bundle. Alternatively, cadaveric studies have demonstrated low risk to the neurovascular bundle using a lateral-to-medial (LTM) approach. The purpose of this study was to compare the incidence of complications of LTM and MTL femoral traction pin placement at a single institution. This was a retrospective review of patients from the orthopaedic consult registry at a academic Level I Trauma Center. We identified 233 LTM femoral traction pin procedures in 231 patients and 29 MTL pin procedures in 29 patients. The two pin placement techniques were compared with respect to complications, specifically the incidence of neurovascular injury, cellulitis, septic arthritis, osteomyelitis, and heterotopic ossification after femoral traction pin placement. Two complications were reported. One patient developed heterotopic ossification along the pin tract after LTM traction pin placement. Another patient developed septic arthritis after LTM pin placement, likely attributable to retrograde intramedullary nailing of his open femur fracture rather than his traction pin. There were no reports of neurovascular injury, cellulitis, or osteomyelitis associated with pin placement. The complication rate was 0.9% for LTM group and 0.0% for MTL group (p = 0.616). LTM femoral traction pin placement is a safe procedure with a similarly low complication rate compared with traditional MTL placement when the limb is positioned in neutral alignment. (Journal of Surgical Orthopaedic Advances 32(4):259-262, 2023).


Subject(s)
Arthritis, Infectious , Femoral Fractures , Fracture Fixation, Intramedullary , Ossification, Heterotopic , Osteomyelitis , Humans , Traction/adverse effects , Traction/methods , Cellulitis , Femur/surgery , Femoral Fractures/epidemiology , Femoral Fractures/surgery , Bone Nails/adverse effects , Fracture Fixation, Intramedullary/adverse effects , Lower Extremity
4.
HSS J ; 18(2): 284-289, 2022 May.
Article in English | MEDLINE | ID: mdl-35645644

ABSTRACT

Background: Recent studies have reported that targeting a center-center position at the distal tibia during intramedullary nailing (IMN) may result in malalignment. Although not fully understood, this observation suggests that the coronal anatomic center of the tibia may not correspond to the center of the distal tibia articular surface. Questions/Purposes: To identify the coronal anatomic axis of the distal tibia that corresponds to an ideal start site for IMN placement utilizing intact cadaveric tibiae. Methods: IMN placement was performed in 9 fresh frozen cadaveric tibiae. A guidewire was used to identify the ideal start site in the proximal tibia and an opening reamer allowed access to the canal. Each nail was then advanced without the use of a reaming rod until exiting the distal tibia plafond. Cadaveric and radiographic measurements were performed to determine the center of the nail exit site in the coronal plane. Results: Cadaveric and radiographic measurements identified the IMN exit site to correspond with the lateral 59.5% and 60.4% of the plafond, respectively. Conclusions: Tibial nails inserted using an ideal start site have an endpoint that corresponds roughly to the junction of the lateral and middle third of the plafond. Further studies are warranted to better understand the impact of IMN endpoint placement on the functional and radiographic outcomes of tibia shaft fractures.

5.
J Surg Orthop Adv ; 31(4): 233-236, 2022.
Article in English | MEDLINE | ID: mdl-36594980

ABSTRACT

This study's objective was to identify a difference in maximum temperature change during forward versus oscillating drilling of cadaveric bone. Paired femurs were dissected from the soft tissue of five cadavers. Each cadaver had one femur assigned to forward and the other to oscillation. The first drill hole was 2.5 cm distal to the lesser trochanter and the remaining 10 holes were evenly spaced 2 cm apart. A System 7 drill and 3.5 mm drill bit were attached to an Instron 5500R to provide a progressive force of 50 Newtons per minute for each drill hole. A thermal camera recorded each drilling. A new drill bit was used for each femur. Fifty bicortical drillings were analyzed in each group. The average time to complete forward drilling (45.0 seconds) was shorter compared to oscillation (55.5 s, p < 0.001). The average force required for forward drilling (27.7 N) was lower than for oscillation (44.3N, p < 0.001). The maximum change in temperature during the drilling process was similar (oscillating 100.2° F vs. forward 100.7° F, p = 0.871). The maximum change in temperature at the near cortex was lower for oscillation (78.1°F) compared to forward drilling (89.1°F, p = 0.011), while the maximum change at the far cortex was lower for forward drilling (89.3°F) compared to oscillation (95.8°F, p = 0.115) but not significantly. Overall, there is no difference in the thermal output between techniques. Oscillation may be beneficial in proximity to vital structures or to navigate narrow bony corridors, but it requires additional time and force. (Journal of Surgical Orthopaedic Advances 31(4):233-236, 2022).


Subject(s)
Bone and Bones , Orthopedic Procedures , Humans , Temperature , Bone and Bones/surgery , Femur/surgery
6.
J Orthop Trauma ; 35(Suppl 5): S32-S37, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34533500

ABSTRACT

SUMMARY: Geriatric hip fractures are complicated by increased morbidity and mortality, and their incidence continues to rise around the world. Frequent considerations in treating geriatric hip fractures include optimal time to surgery, need for preoperative cardiac clearance, risks of operating through anticoagulation, utilization of regional anesthesia, and collaborative care between treatment teams. This article aims to summarize these factors as well as to provide some tips and tricks that can be helpful in their surgical management.


Subject(s)
Anesthesia, Conduction , Hip Fractures , Aged , Hip Fractures/surgery , Humans , Incidence , Morbidity
7.
Ann Transl Med ; 9(3): 210, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33708837

ABSTRACT

BACKGROUND: The purpose of this study was to perform an epidemiological evaluation and an economic analysis of 90-day costs associated with non-fatal gunshot wounds (GSWs) to the extremities, spine and pelvis requiring orthopaedic care in the United States. METHODS: A retrospective epidemiological review of the Medicare national patient record database was conducted from 2005 to 2014. Incidence, fracture location and costs associated where evaluated. Those patients identified through International Classification of Disease (ICD)-9 revision codes and Current Procedural Terminology (CPT) Codes who sustained a fracture secondary to a GSW. Any type of surgical intervention including incision and drainage, open reduction with internal fixation, closed reduction and percutaneous fixation, etc. were identified to analyze, and evaluate costs of care as seen by charges and reimbursements to the payer. The 90-day period after initial fracture care was queried. RESULTS: A total of 9,765 patients required surgical orthopaedic care for GSWs. There was a total of 2,183 fractures due to GSW treated operatively in 2,201 patients. Of these, 22% were femur fractures, 18.3% were hand/wrist fractures and 16.7% were ankle/foot fractures. A majority of patients were male (83.3%) and under 65 years of age (56.3%). Total charges for GSW requiring orthopedic care were $513,334,743 during the 10-year study period. Total reimbursement for these patients were $124,723,068. Average charges per patient were highest for fracture management of the spine $431,021.33, followed by the pelvis $392,658.45 and later by tibia/fibula fractures $342,316.92. CONCLUSIONS: The 90-day direct charges and reimbursements of orthopedic care for non-fatal GSWs are of significant amounts per patient. While the number of fatal GSWs has received much attention, non-fatal GSWs have a large economic and societal impact that warrants further research and consideration by the public and policy makers.

8.
J Orthop Trauma ; 35(4): e148-e152, 2021 04 01.
Article in English | MEDLINE | ID: mdl-32569069

ABSTRACT

SUMMARY: Treatment of periprosthetic distal femur fractures remains challenging due to assuring adequate distal fixation. Traditional treatment options include lateral locked plating and retrograde nailing, although recently dual implant constructs have been explored with promising results. Allowing immediate weight-bearing in this patient population has benefits with regards to rehabilitation and outcome. Recent literature has focused on nail-plate constructs, however plate-plate constructs are preferred at our institution as they do not require arthroplasty component compatibility, facilitate the coronal plane reduction, and allow for immediate weight-bearing.


Subject(s)
Arthroplasty, Replacement, Knee , Femoral Fractures , Periprosthetic Fractures , Bone Plates , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Femur , Fracture Fixation, Internal , Humans , Periprosthetic Fractures/diagnostic imaging , Periprosthetic Fractures/surgery
9.
J Surg Orthop Adv ; 29(2): 65-72, 2020.
Article in English | MEDLINE | ID: mdl-32584217

ABSTRACT

The objective of this study was to describe examples and review the literature of distal humerus fracture reconstruction in the setting of severe bone loss. Four individuals (ages 19-59 years) were treated with either fibular strut allograft or fresh frozen osteochondral allograft in the setting of unreconstructable periarticular bone loss. The radiographs were evaluated for evidence of union. Pain and degrees of range of motion were reported when available. The follow-up period ranged from 3 to 42 months. While additional surgery was often needed, union was ultimately obtained in each case. Normal range of motion was not obtained, but two of the four patients were near normal upon union. Two of the four patients were pain free, and the other two had mild pain. All were limited in their activities, even after union. This case series describes satisfactory results with the use of allograft in this difficult clinical problem. (Journal of Surgical Orthopaedic Advances 29(2):65-72, 2020).


Subject(s)
Elbow Joint , Fractures, Bone , Adult , Bone Plates , Fracture Fixation, Internal , Humans , Humerus/diagnostic imaging , Humerus/surgery , Middle Aged , Range of Motion, Articular , Retrospective Studies , Treatment Outcome , Young Adult
10.
J Orthop Trauma ; 34(6): 302-306, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32433194

ABSTRACT

OBJECTIVES: To compare the efficiency, radiation exposure to surgeon and patient, and accuracy of C-arm versus O-arm with navigation in the placement of transiliac-transsacral and iliosacral screws by an orthopaedic trauma fellow, for a surgeon early in practice. METHODS: Twelve fresh frozen cadavers were obtained. Preoperative computed tomography scans were reviewed to assess for safe corridors in the S1 and S2 segments. Iliosacral screws were assigned to the S1 segment in dysmorphic pelvises. Screws were randomized to modality and laterality. An orthopaedic trauma fellow placed all screws. Time of procedure and radiation exposure to the cadaver and surgeon were recorded. Three fellowship-trained orthopaedic trauma surgeons rated the safety of each screw on postoperative computed tomography scan. RESULTS: Six normal and 6 dysmorphic pelvises were identified. Eighteen transiliac-transsacral screws and 6 iliosacral screws were distributed evenly between C-arm and O-arm. Average operative duration per screw was significantly shorter using C-arm compared with O-arm (15.7 minutes ± 6.1 vs. 23.7 ± 8.5, P = 0.014). Screw placement with C-arm exposed the surgeon to a significantly greater amount of radiation (3.87 × 10 rads vs. 0.32 × 10, P < 0.001) while O-arm exposed the cadaver to a significantly greater amount of radiation (0.03 vs. 2.76 rads, P < 0.001). Two S2 transiliac-transsacral screws (1 C-arm and 1 O-arm) were categorized as unsafe based on scoring. There was no difference in screw accuracy between modalities. CONCLUSIONS: A difference in accuracy between modalities could not be elucidated, whereas efficiency was improved with utilization of C-arm, with statistical significance. A statistically significant increase in radiation exposure to the surgeon using C-arm was found, which may be clinically significant over a career. The results of this study can be extrapolated to a fellow or surgeon early in practice. The decision between use of these modalities will vary depending on surgeon preference and hospital resources.


Subject(s)
Radiation Exposure , Surgeons , Surgery, Computer-Assisted , Bone Screws , Cadaver , Humans , Imaging, Three-Dimensional , Radiation Exposure/prevention & control , Sacrum/diagnostic imaging , Sacrum/surgery , Tomography, X-Ray Computed
11.
J Surg Orthop Adv ; 29(4): 199-201, 2020.
Article in English | MEDLINE | ID: mdl-33416475

ABSTRACT

Vancouver B1 periprosthetic fractures undergoing operative fixation remain difficult to treat due to a short proximal segment that offers limited options for fixation. The trochanteric hook plate addresses this issue by maximizing proximal purchase and utilizing the entire lateral surface area of the greater trochanter. A surgical technique that prioritizes proximal fixation and adheres to basic principles resulted in all fractures healing in a small case series. (Journal of Surgical Orthopaedic Advances 29(4):199-201, 2020).


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Periprosthetic Fractures , Bone Plates , Femoral Fractures/surgery , Femur , Fracture Fixation, Internal , Humans , Periprosthetic Fractures/surgery , Treatment Outcome
12.
Foot Ankle Int ; 41(3): 364-372, 2020 03.
Article in English | MEDLINE | ID: mdl-31833393

ABSTRACT

Negative Pressure Wound Therapy (NPWT) is frequently utilized to manage complex wounds, however its mechanisms of healing remain poorly understood. Changes in growth factor expression, micro- and macro-deformation, blood flow, exudate removal, and bacterial concentration within the wound bed are thought to play a role. NPWT is gaining widespread usage in foot and ankle surgery, including the management of traumatic wounds; diabetic and neuropathic ulcers; wounds left open after debridement for infection or dehiscence; high-risk, closed incisions; tissue grafts and free flaps. This article reviews the rationale for NPWT, its proposed mechanisms of action, and the evidence regarding its clinical applications within the field of foot and ankle surgery. Level of Evidence: Level V, expert opinion.


Subject(s)
Ankle/surgery , Foot/surgery , Negative-Pressure Wound Therapy/methods , Surgical Wound/therapy , Wound Healing/physiology , Humans
13.
J Orthop Trauma ; 33 Suppl 1: S26-S27, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31290827

ABSTRACT

Valgus intertrochanteric osteotomy is an effective method of treating femoral neck nonunion by reducing shear forces at the fracture and correcting the neck-shaft angle. Good outcomes have been reported in the literature. Through careful preoperative planning and a precise operative technique, reliable healing of both the osteotomy and nonunion can be achieved.


Subject(s)
Femoral Neck Fractures/surgery , Femur Neck/surgery , Fracture Fixation, Internal/methods , Fracture Healing , Fractures, Ununited/surgery , Osteotomy/methods , Humans
15.
J Orthop Trauma ; 33(7): 341-345, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30730363

ABSTRACT

OBJECTIVES: To report on our results using a proximal femoral locking plate for the treatment of peritrochanteric femur fractures. DESIGN: Retrospective study. SETTING: Level I Academic Medical Center. PATIENTS: Sixty-eight patients with 68 fractures. INTERVENTION: Demographics, fracture morphology, preoperative imaging, rationale against nailing, and outcomes were collected. MAIN OUTCOME MEASUREMENTS: Outcomes were grouped into no complication, minor complication, or major complication. Minor complications included healed fractures with implant failure or change in alignment from immediate postoperative radiographs, which did not require intervention or elective implant removal. Major complications included any case that required revision for nonunion or implant failure. RESULTS: Nine patients were lost to follow-up. Of the 59 fractures, 16 had complications (27%): 9 minor and 7 major. Active tobacco use (P = 0.020) and fractures with an associated intracapsular femoral neck component (P = 0.006) correlated with complications. CONCLUSIONS: Proximal femoral locking plates continue to be associated with a high complication rate. However, based on our experience, proximal femoral locking plates may be considered in highly selected cases when absolutely no other implant is deemed appropriate, based on the degree of comminution and the complexity of the fracture pattern. Patients must be informed about the possibility of revision surgery based on the inherent limitations of these devices. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Bone Plates , Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Fracture Healing , Bone Screws , Femoral Fractures/diagnosis , Follow-Up Studies , Humans , Radiography , Retrospective Studies
16.
J Orthop Trauma ; 33(5): e183-e189, 2019 May.
Article in English | MEDLINE | ID: mdl-30640295

ABSTRACT

OBJECTIVES: To compare the compressive force achieved and retained with the lag versus positional screw technique at various angles of screw application. METHODS: Sixty humeral sawbones were stratified into 6 groups based on the technique (lag or positional) and fixation angle (30, 60, or 90 degrees relative to the fracture plane). A sensor was placed between fragments to record compressive force. Absolute screw force is the final screw force. Normalized force is the final screw force minus force generated by reduction forceps. Retained force is the quotient of absolute force relative to reduction forceps force. RESULTS: Lag screws attained higher force than positional at 60 degrees (absolute force 41% higher, P = 0.041; normalized force 1300% higher, P = 0.008; retained force 60% higher, P = 0.008) and 90 degrees (absolute force 86% higher, P = 0.006; normalized force 730% higher, P = 0.005; retained force 70% higher, P = 0.011), but not at 30 degrees. For lag screws, compressive force was similar at 60 and 90 degrees (absolute force P = 0.174, normalized force P = 0.364, and retained force P = 0.496), but not 30 degrees. For positional screws, no difference was found between the 3 angles of fixation for absolute force (P = 0.059). Normalized force and retained force were similar at 60 and 90 degrees (P = 0.944 and P = 0.725, respectively), but not 30 degrees. CONCLUSIONS: Lag screw technique compressive force was superior to positional screw technique at 60 and 90 degrees. Comparison of force at angles of 60 and 90 degrees showed no significant difference for both techniques. Indicating 30 degrees deviation from perfect technique is tolerated without significant decrease in compressive force.


Subject(s)
Bone Screws , Compressive Strength , Fracture Fixation, Internal/methods , Humeral Fractures/surgery , Materials Testing/methods , Humans , Pressure
17.
J Surg Orthop Adv ; 27(2): 160-163, 2018.
Article in English | MEDLINE | ID: mdl-30084826

ABSTRACT

The goal of treatment for distal radius fractures is anatomic articular reduction and restoration of coronal and sagittal plane alignment, rotation, and angulation of the metadiaphyseal component of these fractures. This article presents a reproducible technique for restoring coronal plane alignment of the metadiaphyseal component of the fracture using an indirect reduction maneuver leveraging the volar locking plate as an indirect reduction aid. After applying an appropriately sized volar locking plate, the first screw is placed in the center of the shaft of the plate. Next, the distal row of subarticular locking screws is placed to neutralize a reduced articular surface. The shaft screw is subsequently loosened, and two Freer elevators are used to rotate the plate, indirectly translating the distal articular block and achieving improved coronal plane alignment. Last, the remaining diaphyseal screws are applied to appropriately neutralize the fracture. (Journal of Surgical Orthopaedic Advances 27(2):160-163, 2018).


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Radius Fractures/surgery , Adult , Female , Humans
18.
Injury ; 49(2): 409-413, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29305233

ABSTRACT

BACKGROUND: Intra-articular Pilon fractures remain therapeutically challenging due to osteochondral fracturing and comminution, marginal impaction, and insult to the soft tissue envelope. The purpose of this study was to compare the efficacy of anterolateral distal tibial locking plates in capturing main fracture fragments in tibial plafond fractures. METHODS: From May 2011 to Dec 2015, 169 OTA C-type pilon fractures met inclusion and exclusion criteria with computed tomographic (CT) scans performed prior to definitive fixation. For each patient, the fracture lines were mapped, digitized, and graphically superimposed to create a compilation of fracture lines. Based on these average measurements, three distal tibia sawbones had three different anterolateral plates applied. Axial CT scan images were used to determine the efficacy of screw purchase in main fracture fragments in pilon fractures. RESULTS: The Smith & Nephew PERI-LOC plate secured the largest number of fracture lines (90.1%) but missed the Volkmann fragment with greatest frequency at 3.6%. The Synthes 2.7/3.5 mm VA-LCP captured 87.3% of the fracture lines while missing the Volkmann fragment 3.2% of the time. The Synthes 3.5 mm LCP captured 86.5% of the fracture lines but was the best at securing the Volkmann fragment (1.2% missed). All three implants were deficient in capturing the medial malleolar fragment. The PERI-LOC and 2.7/3.5 mm VA-LCP did not differ with respect to percentage of fragments captured (p = 0.721) but both outperformed the 3.5 mm LCP (p = 0.021 and p = 0.05, respectively). CONCLUSIONS: This study was consistent with prior literature in defining three main fracture fragments: anterior, medial, and posterior. All three plates were deficient in capturing the medial malleolar fragment. The Smith and Nephew PERI-LOC plate secured the most number of fracture lines, while the Synthes 3.5 mm LCP was least likely to miss the Volkmann fragment and most likely to miss the medial malleolar fragment. No plate was found to be superior to the other in capturing all fracture lines of the OTAC3 pilon fragments. LEVEL OF EVIDENCE: Three.


Subject(s)
Artificial Organs , Bone and Bones , Fracture Fixation, Internal , Fractures, Comminuted/surgery , Tibial Fractures/surgery , Biomechanical Phenomena , Bone Plates , Bone Screws , Fractures, Comminuted/diagnostic imaging , Humans , Materials Testing , Simulation Training , Tibial Fractures/diagnostic imaging , Tomography, X-Ray Computed , Torsion, Mechanical
19.
J Surg Educ ; 74(1): 61-67, 2017.
Article in English | MEDLINE | ID: mdl-27663081

ABSTRACT

OBJECTIVE: To evaluate orthopedic resident perceptions of a didactic curriculum presented in traditional and case-based formats. DESIGN: Prospective cohort study using anonymous web-based survey after each conference evaluating resident perceptions of faculty participation, didactic delivery, content, and overall conference value. Conferences were structured as primarily case-based or traditional lecture. Logistic analysis was performed to determine factors predictive of rating a conference as valuable time spent. SETTING: Orthopedic residency training program at single institution over an academic year. PARTICIPANTS: Orthopedic residents in postgraduate training year 1 to 5 attending mandatory didactic conference. RESULTS: Cased-based conferences received higher Likert ratings on residents' perception of faculty participation, instructor delivery, and improvement in topic understanding when compared to traditional lecture-based conferences (p < 0.0001 for each factor). Residents also were more likely to rate case-based conferences as valuable time spent (p < 0.0001). In our logistic model, factors associated with a negative likelihood of rating a conference as valuable were lecture format (odds ratio [OR] = 0.155, 95% CI: 0.115-0.208), PGY-2 level presenter (OR = 0.288, 95% CI: 0.169-0.490), and PGY-3 level presenter (OR = 0.433, 95% CI: 0.269-0.696). Timing in the year, surgical subspeciality, and conference identity were not significant predictors of conference value rating. CONCLUSIONS: Longitudinal resident feedback demonstrates highly favorable resident perceptions toward case-based formats in didactic sessions. Junior levels residents are not perceived as effective as senior residents and faculty in presenting material in either format. These methods allow for a dynamic approach to identifying strengths and weaknesses in a resident curriculum as a well as a means for more focused and real-time improvements.


Subject(s)
Clinical Competence , Curriculum , Feedback , Internship and Residency/organization & administration , Orthopedics/education , Adult , Attitude of Health Personnel , Cohort Studies , Competency-Based Education , Education, Medical, Graduate/organization & administration , Female , Humans , Logistic Models , Longitudinal Studies , Male , Odds Ratio , Program Evaluation , Prospective Studies
20.
J Am Acad Orthop Surg ; 22(5): 304-14, 2014 May.
Article in English | MEDLINE | ID: mdl-24788446

ABSTRACT

Combined fractures of the acetabulum and pelvic ring are more common than previously believed, with an incidence as high as 15.7%. Recent series that include combined injuries indicate that the incidence of lateral compression and anteroposterior compression pelvic ring injuries is similar and that transverse and both-column acetabular fractures are the most common acetabular fracture patterns. Combined injuries most often are the result of high-energy mechanisms, and, compared with patients who present with isolated pelvic or acetabular injury, patients with combined injury typically have higher injury severity scores, higher transfusion requirements, and lower systolic blood pressure, with reported mortality rates of 1.5% to 13%. Treatment requires a multidisciplinary approach. The first priority is resuscitation following the Advanced Trauma Life Support protocols. Once the patient is stable, acetabular fractures and pelvic ring injuries should be assessed individually, and the most appropriate treatment for each should be outlined. These treatments should then be integrated to develop the most appropriate overall treatment strategy. Although outcomes data are available for isolated acetabulum and pelvic ring disruptions, no such data currently exist for combined injuries.


Subject(s)
Acetabulum/injuries , Fractures, Bone/surgery , Multiple Trauma/surgery , Sacroiliac Joint/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/etiology , Humans , Prognosis , Pubic Symphysis/injuries , Sacroiliac Joint/injuries
SELECTION OF CITATIONS