Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
RSC Adv ; 14(26): 18136-18146, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38854826

ABSTRACT

A novel magnetic composite bead was synthesized using carbon 18, paracetamol and alginate (mC18/Pa/Alg). The bead was applied to simultaneously adsorb butylated hydroxytoluene, butylated hydroxyanisole, and bisphenol A from water samples by magnetic solid-phase extraction (MSPE). The adsorbed analytes were determined by gas chromatography-flame ionization detection. The morphology and composition of the bead were examined by field emission scanning electron microscopy, energy-dispersive X-ray spectrometry, X-ray diffraction analysis, Fourier transform infrared spectroscopy and Brunauer-Emmett-Teller surface analysis. The best condition of MSPE included an adsorbent bead made with 0.8% sodium alginate, a 0.3 g adsorbent dose, a sample solution pH of 7, and a desorption time of 20 min in methanol. The proposed method exhibited linearity at concentrations between 0.015 and 1.00 µg mL-1 of analytes. Limits of detection ranged from 6.86 to 9.66 ng mL-1. Recoveries from 80.3 to 100.1% were achieved with interday and intraday precisions (RSDs) of 0.4-4.3%.

2.
Mikrochim Acta ; 191(7): 421, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38918206

ABSTRACT

A new, simple, and selective colorimetric method of determining formaldehyde in Hevea brasiliensis latex was developed by using a casein/ferric chloride/polyvinyl alcohol hydrogel composite (casein/FeCl3/PVA) in a modified Leach test. Under heating, formaldehyde reacted with 8% casein in the presence of 0.1% FeCl3 and 4.3% HCl (v/v) entrapped in a 30% PVA hydrogel packed in a syringe. A purple-colored product was formed with a maximum absorbance of 525 nm. The color change was evaluated at the color detection zone indicated on the the syringe. The %magenta values were easily evaluated by using a mobile phone application and employed to determine formaldehyde content. The casein/FeCl3/PVA composite gave a readable response in a formaldehyde detection range from 0.04 to 0.80% with a linear response between %magenta and formaldehyde concentration (R2 = 0.9955). The detection limit was 0.032%, and precisions were in the range 0.67-4.94%. The casein/FeCl3/PVA composite was applied to the analysis of ammonia-preserved latex samples, and recoveries of formaldehyde from samples spiked at 0.1, 0.3, and 0.5% ranged from 81.55 to 99.51% (RSDs ≤ 5.41%). The recoveries and precision of the proposed method were comparable with those of high-performance liquid chromatography (HPLC). The developed method was also selective, showing no interference from other latex preservatives, i.e., phenol, ammonia, or tetramethylthiuram disulfide.

SELECTION OF CITATIONS
SEARCH DETAIL
...