Radiol Cardiothorac Imaging ; 5(3): e210247, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37404790

ABSTRACT

Purpose: To compare the predictive value of different myocardial scar quantification thresholds using cardiac MRI for appropriate implantable cardioverter defibrillator (ICD) shock and mortality. Materials and Methods: In this retrospective, two-center observational cohort study, patients with ischemic or nonischemic cardiomyopathy underwent cardiac MRI prior to ICD implantation. Late gadolinium enhancement (LGE) was first determined visually and then quantified by blinded cardiac MRI readers using different SDs above the mean signal of normal myocardium, full-width half-maximum, and manual thresholding. The intermediate signal "gray zone" was calculated as the differences between different SDs. Results: Among 374 consecutive eligible patients (mean age, 61 years ± 13 [SD]; mean left ventricular ejection fraction, 32% ± 14; secondary prevention, 62.7%), those with LGE had a higher rate of appropriate ICD shock or death than those without (37.5% vs 26.6%, log-rank P = .04) over a median follow-up of 61 months. In multivariable analysis, none of the thresholds for quantifying scar was a significant predictor of mortality or appropriate ICD shock, while the extent of gray zone was an independent predictor (adjusted hazard ratio per 1 g = 1.025; 95% CI: 1.008, 1.043; P = .005) regardless of the presence or absence of ischemic heart disease (P interaction = .57). Model discrimination was highest for the model incorporating the gray zone (between 2 SD and 4 SD). Conclusion: Presence of LGE was associated with a higher rate of appropriate ICD shock or death. Although none of the scar quantification techniques predicted outcomes, the gray zone both in infarct and nonischemic scar was an independent predictor and may refine risk stratification.Keywords: MRI, Scar Quantification, Implantable Cardioverter Defibrillator, Sudden Cardiac Death Supplemental material is available for this article. © RSNA, 2023.

2.
J Cardiovasc Magn Reson ; 23(1): 72, 2021 06 10.
Article in English | MEDLINE | ID: mdl-34108003

ABSTRACT

BACKGROUND: Current indications for implantable cardioverter defibrillator (ICD) implantation for sudden cardiac death prevention rely primarily on left ventricular (LV) ejection fraction (LVEF). Currently, two different contouring methods by cardiovascular magnetic resonance (CMR) are used for LVEF calculation. We evaluated the comparative prognostic value of these two methods in the ICD population, and if measures of LV geometry added predictive value. METHODS: In this retrospective, 2-center observational cohort study, patients underwent CMR prior to ICD implantation for primary or secondary prevention from January 2005 to December 2018. Two readers, blinded to all clinical and outcome data assessed CMR studies by: (a) including the LV trabeculae and papillary muscles (TPM) (trabeculated endocardial contours), and (b) excluding LV TPM (rounded endocardial contours) from the total LV mass for calculation of LVEF, LV volumes and mass. LV sphericity and sphere-volume indices were also calculated. The primary outcome was a composite of appropriate ICD shocks or death. RESULTS: Of the 372 consecutive eligible patients, 129 patients (34.7%) had appropriate ICD shock, and 65 (17.5%) died over a median duration follow-up of 61 months (IQR 38-103). LVEF was higher when including TPM versus excluding TPM (36% vs. 31%, p < 0.001). The rate of appropriate ICD shock or all-cause death was higher among patients with lower LVEF both including and excluding TPM (p for trend = 0.019 and 0.004, respectively). In multivariable models adjusting for age, primary prevention, ischemic heart disease and late gadolinium enhancement, both LVEF (HR per 10% including TPM 0.814 [95%CI 0.688-0.962] p = 0.016, vs. HR per 10% excluding TPM 0.780 [95%CI 0.639-0.951] p = 0.014) and LV mass index (HR per 10 g/m2 including TPM 1.099 [95%CI 1.027-1.175] p = 0.006; HR per 10 g/m2 excluding TPM 1.126 [95%CI 1.032-1.228] p = 0.008) had independent prognostic value. Higher LV end-systolic volumes and LV sphericity were significantly associated with increased mortality but showed no added prognostic value. CONCLUSION: Both CMR post-processing methods showed similar prognostic value and can be used for LVEF assessment. LVEF and indexed LV mass are independent predictors for appropriate ICD shocks and all-cause mortality in the ICD population.


Subject(s)
Defibrillators, Implantable , Contrast Media , Gadolinium , Humans , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Prognosis , Retrospective Studies , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...