Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 8681, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622196

ABSTRACT

Archaeological wood can be preserved in waterlogged conditions. Due to their degradation in the ground, these archaeological remains are endangered after their discovery, since they decay irretrievably during drying. Conservation measures are used to preserve waterlogged archaeological objects, maintaining their shape and character as much as possible. However, different methods have been developed leading to varying results. This study compares their effectiveness in order to clarify their mode of action. The methods including alcohol-ether resin, lactitol/trehalose, melamine formaldehyde, polyethylene glycol impregnation prior to freeze-drying, saccharose and silicone oil were assessed by analysing mass changes and volume stability using structured-light 3D scanning. The state of the conserved wood samples including the spatial distribution of the conservation agent was examined using synchrotron micro-computed tomography. Raman spectroscopy was used to observe the agent´s spatial distribution within the cells. The findings demonstrated that melamine formaldehyde stabilises the degraded cell walls. The lumens are void, as in the case with alcohol-ether resin, while polyethylene glycol, silicone oil, saccharose and lactitol/trehalose also occupy the lumens. It is assumed that the drying method has an effect on the distribution of the solidifying agent. The knowledge gained affords insights into the mechanism of conservation methods, which in turn accounts for the varied outcomes. It also allows conclusions to be drawn about the condition and stability of conserved museum objects and serves as a starting point for the further development of conservation methods.

2.
Arthropod Struct Dev ; 79: 101346, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38520874

ABSTRACT

The large abundance of termites is partially achieved by their defensive abilities. Stylotermitidae represented by a single extant genus, Stylotermes, is a member of a termite group Neoisoptera that encompasses 83% of termite species and 94% of termite genera and is characterized by the presence of the frontal gland. Within Neoisoptera, Stylotermitidae represents a species-poor sister lineage of all other groups. We studied the structure of the frontal, labral and labial glands in soldiers and workers of Stylotermes faveolus, and the composition of the frontal gland secretion in S. faveolus and Stylotermes halumicus. We show that the frontal gland is a small active secretory organ in soldiers and workers. It produces a cocktail of monoterpenes in soldiers, and some of these monoterpenes and unidentified proteins in workers. The labral and labial glands are developed similarly to other termite species and contribute to defensive activities (labral in both castes, labial in soldiers) or to the production of digestive enzymes (labial in workers). Our results support the importance of the frontal gland in the evolution of Neoisoptera. Toxic, irritating and detectable monoterpenes play defensive and pheromonal functions and are likely critical novelties contributing to the ecological success of these termites.


Subject(s)
Cockroaches , Isoptera , Animals , Pheromones/metabolism , Monoterpenes/metabolism
3.
ACS Nano ; 18(14): 10054-10062, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38527458

ABSTRACT

Perovskite nanocrystals (PNCs) bear a huge potential for widespread applications, such as color conversion, X-ray scintillators, and active laser media. However, the poor intrinsic stability and high susceptibility to environmental stimuli including moisture and oxygen have become bottlenecks of PNC materials for commercialization. Appropriate barrier material design can efficiently improve the stability of the PNCs. Particularly, the strategy for packaging PNCs in organosilicon matrixes can integrate the advantages of inorganic-oxide-based and polymer-based encapsulation routes. However, the inert long-carbon-chain ligands (e.g., oleic acid, oleylamine) used in the current ligand systems for silicon-based encapsulation are detrimental to the cross-linking of the organosilicon matrix, resulting in performance deficiencies in the nanocrystal films, such as low transparency and large surface roughness. Herein, we propose a dual-organosilicon ligand system consisting of (3-aminopropyl)triethoxysilane (APTES) and (3-aminopropyl)triethoxysilane with pentanedioic anhydride (APTES-PA), to replace the inert long-carbon-chain ligands for improving the performance of organosilicon-coated PNC films. As a result, strongly fluorescent PNC films prepared by a facile solution-casting method demonstrate high transparency and reduced surface roughness while maintaining high stability in various harsh environments. The optimized PNC films were eventually applied in an X-ray imaging system as scintillators, showing a high spatial resolution above 20 lp/mm. By designing this promising dual organosilicon ligand system for PNC films, our work highlights the crucial influence of the molecular structure of the capping ligands on the optical performance of the PNC film.

4.
Biol Lett ; 19(12): 20230399, 2023 12.
Article in English | MEDLINE | ID: mdl-38115747

ABSTRACT

Parasitism is ubiquitous across the tree of life, and parasites comprise approximately half of all animal species. Social insect colonies attract many pathogens, endo- and ectoparasites, and are exploited by social parasites, which usurp the social environment of their hosts for survival and reproduction. Exploitation by parasites and pathogens versus social parasites may cause similar behavioural and morphological modifications of the host. Ants possess two overlapping syndromes: the endo- and social parasite syndromes. We rediscovered two populations of the putative social parasite Manica parasitica in the Sierra Nevada, and tested the hypothesis that M. parasitica is an independently evolving social parasite. We evaluated traits used to discriminate M. parasitica from its host Manica bradleyi, and examined the morphology of M. parasitica in the context of ant parasitic syndromes. We find that M. parasitica is not a social parasite. Instead, M. parasitica represents cestode-infected M. bradleyi. We propose that M. parasitica should be regarded as a junior synonym of M. bradleyi. Our results emphasize that an integrative approach is essential for unravelling the complex life histories of social insects and their symbionts.


Subject(s)
Ants , Parasites , Animals , Host-Parasite Interactions , Social Behavior , Reproduction
5.
J Appl Crystallogr ; 56(Pt 3): 776-786, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37284267

ABSTRACT

Two wafers of one 4H-silicon carbide (4H-SiC) bulk crystal, one cut from a longitudinal position close to the crystal's seed and the other close to the cap, were characterized with synchrotron white-beam X-ray topography (SWXRT) in back-reflection and transmission geometry to investigate the dislocation formation and propagation during growth. For the first time, full wafer mappings were recorded in 00012 back-reflection geometry with a CCD camera system, providing an overview of the dislocation arrangement in terms of dislocation type, density and homogeneous distribution. Furthermore, by having similar resolution to conventional SWXRT photographic film, the method enables identification of individual dislocations, even single threading screw dislocations, which appear as white spots with a diameter in the range of 10 to 30 µm. Both investigated wafers showed a similar dislocation arrangement, suggesting a constant propagation of dislocations during crystal growth. A systematic investigation of crystal lattice strain and tilt at selected wafer areas with different dislocation arrangements was achieved with high-resolution X-ray diffractometry reciprocal-space map (RSM) measurements in the symmetric 0004 reflection. It was shown that the diffracted intensity distribution of the RSM for different dislocation arrangements depends on the locally predominant dislocation type and density. Moreover, the orientation of specific dislocation types along the RSM scanning direction has a strong influence on the local crystal lattice properties.

6.
Proc Biol Sci ; 289(1967): 20212086, 2022 01 26.
Article in English | MEDLINE | ID: mdl-35078362

ABSTRACT

One key event in insect evolution was the development of mandibles with two joints, which allowed powerful biting but restricted their movement to a single degree of freedom. These mandibles define the Dicondylia, which constitute over 99% of all extant insect species. It was common doctrine that the dicondylic articulation of chewing mandibles remained unaltered for more than 400 million years. We report highly modified mandibles overcoming the restrictions of a single degree of freedom and hypothesize their major role in insect diversification. These mandibles are defining features of parasitoid chalcid wasps, one of the most species-rich lineages of insects. The shift from powerful chewing to precise cutting likely facilitated adaptations to parasitize hosts hidden in hard substrates, which pose challenges to the emerging wasps. We reveal a crucial step in insect evolution and highlight the importance of comprehensive studies even of putatively well-known systems.


Subject(s)
Wasps , Adaptation, Physiological , Animals , Host-Parasite Interactions , Phylogeny
7.
ACS Appl Mater Interfaces ; 12(13): 15774-15784, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32182029

ABSTRACT

Flexible direct conversion X-ray detectors enable a variety of novel applications in medicine, industry, and science. Hybrid organic-inorganic perovskite semiconductors containing elements of high atomic number combine an efficient X-ray absorption with excellent charge transport properties. Due to their additional cost-effective and low-temperature processability, perovskite semiconductors represent promising candidates to be used as active materials in flexible X-ray detectors. Inspired by the promising results recently reported on X-ray detectors that are based on either triple cation perovskites or inkjet-printed perovskite quantum dots, we here investigate flexible inkjet-printed triple cation perovskite X-ray detectors. The performance of the detectors is evaluated by the X-ray sensitivity, the dark current, and the X-ray stability. Exposed to 70 kVp X-ray radiation, reproducible and highly competitive X-ray sensitivities of up to 59.9 µC/(Gyaircm2) at low operating voltages of 0.1 V are achieved. Furthermore, a significant dark current reduction is demonstrated in our detectors by replacing spin-coated poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT:PSS) with sputtered NiOx hole transport layers. Finally, stable operation of a flexible X-ray detector for a cumulative X-ray exposure of 4 Gyair is presented, and the applicability of our devices as X-ray imaging detectors is shown. The results of this study represent a proof of concept toward flexible direct conversion X-ray detectors realized by cost-effective and high-throughput digital inkjet printing.

8.
Sci Rep ; 9(1): 5231, 2019 Mar 26.
Article in English | MEDLINE | ID: mdl-30914697

ABSTRACT

A variety of medical, industrial, and scientific applications requires highly sensitive and cost-effective x-ray detectors for photon energies ranging from keV to MeV. Adapting the thickness of polycrystalline or single crystal conversion layers especially to high-energy applications increases the complexity of fabrication and potentially decreases the performance of conventional direct conversion x-ray detectors. To tackle the challenges with respect to the active layer thickness and to combine the superior performance of single crystal materials with the low-cost nature of polycrystalline conversion layers, we investigate thin film x-ray detector technologies based on a folded device architecture. Analytical models simulating the sensitivity and the detective quantum efficiency (DQE) are used to evaluate the performance of folded detectors based on polycrystalline organic-inorganic perovskite semiconductors in various layout configurations and for different photon energies. Simulations of folded perovskite devices show high sensitivities. The DQE analysis introduces additional noise related boundary conditions for the folding length. A comparison with conventional detectors based on state of the art conversion materials at different photon energies demonstrates the potential of the folded detector layout as simulated sensitivities are comparable to single crystal detectors.

9.
Sci Rep ; 7: 41413, 2017 01 27.
Article in English | MEDLINE | ID: mdl-28128302

ABSTRACT

Non-destructive imaging techniques can be extremely useful tools for the investigation and the assessment of palaeontological objects, as mechanical preparation of rare and valuable fossils is precluded in most cases. However, palaeontologists are often faced with the problem of choosing a method among a wide range of available techniques. In this case study, we employ x-ray computed tomography (CT) and computed laminography (CL) to study the first fossil xiphosuran from the Muschelkalk (Middle Triassic) of the Netherlands. The fossil is embedded in micritic limestone, with the taxonomically important dorsal shield invisible, and only the outline of its ventral part traceable. We demonstrate the complementarity of CT and CL which offers an excellent option to visualize characteristic diagnostic features. We introduce augmented laminography to correlate complementary information of the two methods in Fourier space, allowing to combine their advantages and finally providing increased anatomical information about the fossil. This method of augmented laminography enabled us to identify the xiphosuran as a representative of the genus Limulitella.


Subject(s)
Fossils/anatomy & histology , Imaging, Three-Dimensional/methods , Animals , Horseshoe Crabs/anatomy & histology , Netherlands , Paleontology , Tomography, X-Ray Computed
10.
Opt Express ; 24(24): 27753-27762, 2016 Nov 28.
Article in English | MEDLINE | ID: mdl-27906343

ABSTRACT

We present an improved, single-distance phase retrieval algorithm applicable for holographic X-ray imaging of biological objects for an in-line germanium Bragg Magnifier Microscope (BMM). The proposed algorithm takes advantage of a modified shrink-wrap algorithm for phase objects, robust unwrapping algorithm as well as other reasonable constraints applied to the wavefield at the object and the detector plane. The performance of the algorithm is analyzed on phantom objects and the results are shown and discussed. We demonstrated the suitability of the algorithm for the phase retrieval on a more complex biological specimen Tardigrade, where we achieved successful phase retrieval from only a single hologram. The spatial resolution obtained by Fourier spectral power method for biological objects is ∼ 300 nm, the same value as obtained from the reconstructed test pattern. Our results achieved using the new algorithm confirmed the potential of BMM for in-vivo, dose-efficient single-shot imaging of biological objects.

11.
IEEE Trans Med Imaging ; 34(3): 707-15, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24759983

ABSTRACT

High resistivity gallium arsenide is considered a suitable sensor material for spectroscopic X-ray imaging detectors. These sensors typically have thicknesses between a few hundred µm and 1 mm to ensure a high photon detection efficiency. However, for small pixel sizes down to several tens of µm, an effect called charge sharing reduces a detector's spectroscopic performance. The recently developed Medipix3RX readout chip overcomes this limitation by implementing a charge summing circuit, which allows the reconstruction of the full energy information of a photon interaction in a single pixel. In this work, we present the characterization of the first Medipix3RX detector assembly with a 500 µm thick high resistivity, chromium compensated gallium arsenide sensor. We analyze its properties and demonstrate the functionality of the charge summing mode by means of energy response functions recorded at a synchrotron. Furthermore, the imaging properties of the detector, in terms of its modulation transfer functions and signal-to-noise ratios, are investigated. After more than one decade of attempts to establish gallium arsenide as a sensor material for photon counting detectors, our results represent a breakthrough in obtaining detector-grade material. The sensor we introduce is therefore suitable for high resolution X-ray imaging applications.


Subject(s)
Spectrometry, X-Ray Emission/instrumentation , Spectrometry, X-Ray Emission/methods , Tomography, X-Ray Computed/methods , Arsenicals/pharmacology , Cadmium Compounds/pharmacology , Gallium/pharmacology , Humans , Photons , Principal Component Analysis , Tellurium/pharmacology
12.
Phys Med Biol ; 59(20): 6195-213, 2014 Oct 21.
Article in English | MEDLINE | ID: mdl-25255737

ABSTRACT

Spectroscopic x-ray imaging based on pixellated semiconductor detectors can be sensitive to charge sharing and K-fluorescence, depending on the sensor material used, its thickness and the pixel pitch employed. As a consequence, spectroscopic resolution is partially lost. In this paper, we study a new detector ASIC, the Medipix3RX, that offers a novel feature called charge summing, which is established by making adjacent pixels communicate with each other. Consequently, single photon interactions resulting in multiple hits are almost completely avoided. We investigate this charge summing mode with respect to those of its imaging properties that are of interest in medical physics and benchmark them against the case without charge summing. In particular, we review its influence on spectroscopic resolution and find that the low energy bias normally present when recording energy spectra is dramatically reduced. Furthermore, we show that charge summing provides a modulation transfer function which is almost independent of the energy threshold setting, which is in contrast to approaches common so far. We demonstrate that this property is directly linked to the detective quantum efficiency, which is found to increase by a factor of three or more when the energy threshold approaches the photon energy and when using charge summing. As a consequence, the contrast-to-noise ratio is found to double at elevated threshold levels and the dynamic range increases for a given counter depth. All these effects are shown to lead to an improved ability to perform material discrimination in spectroscopic CT, using iodine and gadolinium contrast agents. Hence, when compared to conventional photon counting detectors, these benefits carry the potential of substantially reducing the imaging dose a patient is exposed to during diagnostic CT examinations.


Subject(s)
Photoelectron Spectroscopy/methods , Photons , Radiography/methods , Photoelectron Spectroscopy/instrumentation , Radiography/instrumentation , Semiconductors , X-Rays
13.
J Synchrotron Radiat ; 20(Pt 1): 153-9, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23254668

ABSTRACT

The performance of a recently developed full-field X-ray micro-imaging system based on an in-line Bragg magnifier is reported. The system is composed of quasi-channel-cut crystals in combination with a Medipix single-photon-counting detector. A theoretical and experimental study of the imaging performance of the crystals-detector combination and a comparison with a standard indirect detector typically used in high-resolution X-ray imaging schemes are reported. The spatial resolution attained by our system is about 0.75 µm, limited only by the current magnification. Compared with an indirect detector system, this system features a better efficiency, signal-to-noise ratio and spatial resolution. The optimal working resolution range of this system is between ∼0.4 µm and 1 µm, filling the gap between transmission X-ray microscopes and indirect detectors. Applications for coherent full-field imaging of weakly absorbing samples are shown and discussed.


Subject(s)
Radiographic Image Enhancement/instrumentation , Holography/methods , Radiographic Image Enhancement/methods , X-Rays
14.
Phys Med Biol ; 57(21): 6743-59, 2012 Nov 07.
Article in English | MEDLINE | ID: mdl-23032372

ABSTRACT

Spectroscopic x-ray imaging by means of photon counting detectors has received growing interest during the past years. Critical to the image quality of such devices is their pixel pitch and the sensor material employed. This paper describes the imaging properties of Medipix2 MXR multi-chip assemblies bump bonded to 1 mm thick CdTe sensors. Two systems were investigated with pixel pitches of 110 and 165 µm, which are in the order of the mean free path lengths of the characteristic x-rays produced in their sensors. Peak widths were found to be almost constant across the energy range of 10 to 60 keV, with values of 2.3 and 2.2 keV (FWHM) for the two pixel pitches. The average number of pixels responding to a single incoming photon are about 1.85 and 1.45 at 60 keV, amounting to detective quantum efficiencies of 0.77 and 0.84 at a spatial frequency of zero. Energy selective CT acquisitions are presented, and the two pixel pitches' abilities to discriminate between iodine and gadolinium contrast agents are examined. It is shown that the choice of the pixel pitch translates into a minimum contrast agent concentration for which material discrimination is still possible. We finally investigate saturation effects at high x-ray fluxes and conclude with the finding that higher maximum count rates come at the cost of a reduced energy resolution.


Subject(s)
Cadmium Compounds , Tellurium , Tomography, X-Ray Computed/methods , Contrast Media , Image Processing, Computer-Assisted , Phantoms, Imaging , Radiometry , Temperature , Water
15.
J Synchrotron Radiat ; 18(Pt 5): 753-60, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21862856

ABSTRACT

In this work an X-ray imaging system based on a recently developed in-line two-dimensional Bragg magnifier composed of two monolithic V-shaped crystals made of dislocation-free germanium is presented. The channel-cut crystals were used in one-dimensional and in two-dimensional (crossed) configurations in imaging applications and allowed measurement of phase-contrast radiograms both in the edge-enhanced and in the holographic regimes. The measurement of the phase gradient in two orthogonal directions is demonstrated. The effective pixel size attained was 0.17 µm in the one-dimensional configuration and 0.5 µm in the two-dimensional setting, offering a twofold improvement in spatial resolution over devices based on silicon. These results show the potential for applying Bragg magnifiers to imaging soft matter at high resolution with reduced dose owing to the higher efficiency of Ge compared with Si.

SELECTION OF CITATIONS
SEARCH DETAIL
...