ABSTRACT
Early active motion limits adhesion formation and thus improves functional performance after tendon grafting. The early strength of distal fixation is critical to successful tendon grafting. We describe a new Y-tunnel technique of distal fixation and compare it with 2 established methods, the Pulvertaft transverse tunnel and the Bunnell button over the fingernail techniques, in a human cadaver model to determine which is the strongest method. Hands with a grafted tendon were rigidly mounted on an anatomic tensiometer testing apparatus and loaded to failure. Mean load to failure (newtons +/- 95% confidence intervals) of the Y-tunnel technique (155.2 +/- 29.4) was greater than those for the Pulvertaft (100.2 +/- 13.2) and Bunnell (57.1 +/- 4.7) techniques. Two-way analysis of variance showed significant differences, and the Bonferroni multiple pairwise comparison test showed that all 3 intergroup comparisons were statistically significant. These results indicate marked improvement in immediate strength with the Y-tunnel technique and lay the groundwork for further studies using a healing tendon model.