Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 360
Filter
1.
Antioxidants (Basel) ; 13(8)2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39199188

ABSTRACT

Tisochrysis lutea is a highly nutritious marine microalga that has various applications in aquaculture and biotechnology. However, the effects of T. lutea extract (TLE) on osteoarthritis (OA) pathogenesis remain unexplored. In this study, we aimed to determine the effects of TLE on OA development. We found that TLE inhibits the expression of matrix metalloproteinases (MMPs) and reactive oxygen species (ROS) activity in an OA mouse model generated by the destabilization of the medial meniscus (DMM) surgery. In vivo assays of the OA model mice demonstrated that TLE has a protective effect against cartilage destruction by inhibiting MMP3 and MMP13 expression. To enable the medical use of TLE, the components of TLE were characterized using high-performance liquid chromatography (HPLC) analysis. Interestingly, we found that Fucoxanthin accounts for 41.2% of TLE and showed anti-catabolic and antioxidant effects under IL-1ß-treated in vitro conditions. RNA sequencing analysis showed that fucoxanthin decreased p38, NF-κB, and JNK signaling pathway gene expression, all of which are activated by IL-1ß. Furthermore, in vivo analysis showed that fucoxanthin inhibited the IL-1ß-stimulated phosphorylation of p65, JNK, and p38. These results highlight new possibilities for the use of TLE as a source of fucoxanthin, an antioxidant, for OA treatment.

2.
Int J Mol Sci ; 25(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38892435

ABSTRACT

Acute liver failure is an infrequent yet fatal condition marked by rapid liver function decline, leading to abnormalities in blood clotting and cognitive impairment among individuals without prior liver ailments. The primary reasons for liver failure are infection with hepatitis virus or overdose of certain medicines, such as acetaminophen. Phaeodactylum tricornutum (PT), a type of microalgae known as a diatom species, has been reported to contain an active ingredient with anti-inflammatory and anti-obesity effects. In this study, we evaluated the preventive and therapeutic activities of PT extract in acute liver failure. To achieve our purpose, we used two different acute liver failure models: acetaminophen- and D-GalN/LPS-induced acute liver failure. PT extract showed protective activity against acetaminophen-induced acute liver failure through attenuation of the inflammatory response. However, we failed to demonstrate the protective effects of PT against acute liver injury in the D-GalN/LPS model. Although the PT extract did not show protective activity against two different acute liver failure animal models, this study clearly demonstrates the importance of considering the differences among animal models when selecting an acute liver failure model for evaluation.


Subject(s)
Acetaminophen , Chemical and Drug Induced Liver Injury , Disease Models, Animal , Microalgae , Animals , Acetaminophen/adverse effects , Mice , Chemical and Drug Induced Liver Injury/drug therapy , Microalgae/chemistry , Liver Failure, Acute/chemically induced , Liver Failure, Acute/drug therapy , Male , Protective Agents/pharmacology , Protective Agents/therapeutic use , Ethanol/adverse effects , Diatoms , Liver/drug effects , Liver/pathology , Liver/metabolism , Lipopolysaccharides/adverse effects
3.
Clin Orthop Surg ; 16(3): 506-516, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827756

ABSTRACT

Background: The gait analysis method that has been used in clinical practice to date is an optical tracking system (OTS) using a marker, but a markerless gait analysis (MGA) system is being developed because of the expensive cost and complicated examination of the OTS. To apply this MGA clinically, a comparative study of the MGA and OTS methods is necessary. The purpose of this study was to evaluate the compatibility between the OTS and the MGA methods and to evaluate the usefulness of the MGA system in actual clinical settings. Methods: From March 2021 to August 2021, 14 patients underwent gait analysis using the OTS and MGA system, and the spatiotemporal parameters and kinematic results obtained by the 2 methods were compared. To evaluate the practicality of the MGA system in an actual clinical setting, MGA was performed on 14 symptomatic children with idiopathic toe walking, who had been treated with a corrective cast, and the pre-cast and post-cast results were compared. For the OTS, the Motion Analysis Eagle system was used, and for MGA, DH Walk was used. Results: The spatiotemporal parameters showed no significant difference between the OTS and MGA system. The joint angle graphs of the kinematics along the sagittal plane showed similar shapes as a whole, with particularly high correlations in the hip and knee (pelvis: 29.4%, hip joint: 96.7%, knee joint: 94.9%, and ankle joint: 68.5%). A quantified comparison using the CORrelation and Analysis (CORA) score also showed high similarity between the 2 methods. The MGA results of pre-cast application and post-cast removal for children with idiopathic toe walking showed a statistically significant improvement in ankle dorsiflexion after treatment (p < 0.001). Conclusions: MGA showed a good correlation with the conventional OTS in terms of spatiotemporal parameters and kinematics. We demonstrated that ankle sagittal kinematics improved after treatment by corrective cast in children with idiopathic toe walking using the MGA method. Thus, after the improvement of a few limitations, the MGA system may soon be able to be clinically applied.


Subject(s)
Feasibility Studies , Gait Analysis , Humans , Gait Analysis/methods , Child , Male , Female , Biomechanical Phenomena , Adolescent , Gait/physiology , Child, Preschool
4.
Vasc Specialist Int ; 40: 17, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38845442

ABSTRACT

Purpose: There is limited data on the midterm results of endovascular treatment for acute type B aortic dissection (TBAD) with malperfusion syndrome (MS), particularly in Asia. This study aimed to investigate the clinical outcomes of endovascular treatment of acute TBAD with MS. Materials and Methods: We retrospectively analyzed 27 patients who underwent endovascular treatment for acute TBAD with MS. Results: Among the 27 patients with TBAD and MS, malperfusion was observed in the isolated renal (44.4%), visceral (7.4%) and iliofemoral (25.9%) arteries, as well as their combinations (22.2%). The patients underwent thoracic endovascular aortic repair (TEVAR) only (25.9%), selective stenting only in arteries affected by malperfusion (22.2%), or combined treatment with TEVAR and selective stenting (51.9%). Primary technical success was achieved in all the patients. No inhospital mortality or early death within 30 days after operation occurred. The rates of stroke, limb ischemia, acute kidney injury, and reintervention at 30 days were 7.4%, 3.7%, 25.9%, and 3.7%, respectively. The mean follow-up period was 4.3±3.1 years. During the follow-up, the rates of death, stroke, maintenance hemodialysis, aneurysmal change, and reintervention were 0%, 3.7%, 7.4%, 7.4%, and 7.4%, respectively. Two patients required reintervention due to limb ischemia and aneurysmal changes in the distal portion of the stent graft. Computed tomography scans revealed a significant increase in aortic diameters in patients who underwent selective stenting compared to those who underwent TEVAR over a 3-year period, with changes in aortic area measuring 878.9 mm2 vs. 188.4 mm2 at the middle of the lesion (P=0.037), 303.7 mm2 vs. 22.8 mm2 at the level of the celiac trunk (P=0.025), and 442.9 mm2 vs. 37.3 mm2 at the level of the renal artery (P=0.019). Conclusion: The endovascular treatment of acute TBAD with MS demonstrated a high primary technical success rate and promising short- and midterm clinical outcomes.

5.
Circ Cardiovasc Interv ; 17(7): e013585, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38786579

ABSTRACT

BACKGROUND: The efficacy and safety of each third-generation drug-eluting stent with ultrathin struts and advanced polymer technology remain unclear. We investigated the clinical outcomes of percutaneous coronary intervention using the Coroflex ISAR polymer-free sirolimus-eluting stent (SES) or Orsiro biodegradable polymer SES. METHODS: The HOST-IDEA trial (Harmonizing Optimal Strategy for Treatment of Coronary Artery Stenosis-Coronary Intervention With Next-Generation Drug-Eluting Stent Platforms and Abbreviated Dual Antiplatelet Therapy), initially designed with a 2×2 factorial approach, sought to randomize patients undergoing percutaneous coronary intervention based on dual antiplatelet therapy duration (3 versus 12 months) and stent type (Coroflex ISAR versus Orsiro). Despite randomizing 2013 patients for dual antiplatelet therapy duration, the stent arm transitioned to a registry format during the trial. Among these, 328 individuals (16.3%) were randomized for Coroflex ISAR or Orsiro SES, while 1685 (83.7%) underwent percutaneous coronary intervention without stent-type randomization. In this study, the Coroflex ISAR (n=559) and Orsiro groups (n=1449) were matched using a propensity score. The prespecified primary end point was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization at 12 months. RESULTS: The baseline patient and procedural characteristics were well balanced between the Coroflex ISAR and Orsiro groups after propensity score matching (n=559, each group). The Coroflex ISAR group was significantly associated with a higher rate of target lesion failure, mainly driven by clinically driven target lesion revascularization, compared with the Orsiro group (3.4% versus 1.1%; hazard ratio, 3.21 [95% CI, 1.28-8.05]; P=0.01). A higher risk of target lesion failure in the Coroflex ISAR group was consistently observed across various subgroups. The rates of any bleeding (hazard ratio, 0.85 [95% CI, 0.51-1.40]; P=0.52) and major bleeding (hazard ratio, 1.58 [95% CI, 0.61-4.08]; P=0.34) were comparable between the 2 groups. CONCLUSIONS: In this propensity score-matched analysis of the stent arm registry from the HOST-IDEA trial, the Orsiro SES was associated with significantly better outcomes in terms of 1-year target lesion failure, mainly driven by clinically driven target lesion revascularization, than the Coroflex ISAR SES. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02601157.


Subject(s)
Absorbable Implants , Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Polymers , Prosthesis Design , Registries , Sirolimus , Humans , Male , Female , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Aged , Middle Aged , Treatment Outcome , Time Factors , Polymers/chemistry , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Risk Factors , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/adverse effects , Sirolimus/administration & dosage , Sirolimus/adverse effects , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Dual Anti-Platelet Therapy , Hemorrhage/chemically induced , Risk Assessment , Coronary Stenosis/therapy , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Prospective Studies , Myocardial Infarction/etiology
6.
J Am Med Inform Assoc ; 31(7): 1540-1550, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38804963

ABSTRACT

OBJECTIVE: Predicting mortality after acute myocardial infarction (AMI) is crucial for timely prescription and treatment of AMI patients, but there are no appropriate AI systems for clinicians. Our primary goal is to develop a reliable and interpretable AI system and provide some valuable insights regarding short, and long-term mortality. MATERIALS AND METHODS: We propose the RIAS framework, an end-to-end framework that is designed with reliability and interpretability at its core and automatically optimizes the given model. Using RIAS, clinicians get accurate and reliable predictions which can be used as likelihood, with global and local explanations, and "what if" scenarios to achieve desired outcomes as well. RESULTS: We apply RIAS to AMI prognosis prediction data which comes from the Korean Acute Myocardial Infarction Registry. We compared FT-Transformer with XGBoost and MLP and found that FT-Transformer has superiority in sensitivity and comparable performance in AUROC and F1 score to XGBoost. Furthermore, RIAS reveals the significance of statin-based medications, beta-blockers, and age on mortality regardless of time period. Lastly, we showcase reliable and interpretable results of RIAS with local explanations and counterfactual examples for several realistic scenarios. DISCUSSION: RIAS addresses the "black-box" issue in AI by providing both global and local explanations based on SHAP values and reliable predictions, interpretable as actual likelihoods. The system's "what if" counterfactual explanations enable clinicians to simulate patient-specific scenarios under various conditions, enhancing its practical utility. CONCLUSION: The proposed framework provides reliable and interpretable predictions along with counterfactual examples.


Subject(s)
Artificial Intelligence , Myocardial Infarction , Humans , Myocardial Infarction/mortality , Myocardial Infarction/diagnosis , Prognosis , Male , Registries , Female , Republic of Korea , Reproducibility of Results , Aged , Middle Aged
7.
Korean Circ J ; 54(6): 339-350, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38767441

ABSTRACT

BACKGROUND AND OBJECTIVES: Ultimaster™, a third-generation sirolimus-eluting stent using biodegradable polymer, has been introduced to overcome long term adverse vascular events, such as restenosis or stent thrombosis. In the present study, we aimed to evaluate the 12-month clinical outcomes of Ultimaster™ stents in Korean patients with coronary artery disease. METHODS: This study is a multicenter, prospective, observational registry across 12 hospitals. To reflect real-world clinical evidence, non-selective subtypes of patients and lesions were included in this study. The study end point was target lesion failure (TLF) (the composite of cardiac death, target vessel myocardial infarction [MI], and target lesion revascularization [TLR]) at 12-month clinical follow up. RESULTS: A total of 576 patients were enrolled between November 2016 and May 2021. Most of the patients were male (76.5%), with a mean age of 66.0±11.2 years. Among the included patients, 40.1% had diabetes mellitus (DM) and 67.9% had acute coronary syndrome (ACS). At 12 months, the incidence of TLF was 4.1%. The incidence of cardiac death was 1.5%, MI was 1.0%, TLR was 2.7%, and stent thrombosis was 0.6%. In subgroup analysis based on the presence of ACS, DM, hypertension, dyslipidemia, or bifurcation, there were no major differences in the incidence of the primary endpoint. CONCLUSIONS: The present registry shows that Ultimaster™ stent is safe and effective for routine real-world clinical practice in non-selective Korean patients, having a low rate of adverse events at least up to 12 months.

8.
Stem Cell Res Ther ; 15(1): 118, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38659053

ABSTRACT

BACKGROUND: Cerebral organoids (COs) are the most advanced in vitro models that resemble the human brain. The use of COs as a model for Alzheimer's disease (AD), as well as other brain diseases, has recently gained attention. This study aimed to develop a human AD CO model using normal human pluripotent stem cells (hPSCs) that recapitulates the pathological phenotypes of AD and to determine the usefulness of this model for drug screening. METHODS: We established AD hPSC lines from normal hPSCs by introducing genes that harbor familial AD mutations, and the COs were generated using these hPSC lines. The pathological features of AD, including extensive amyloid-ß (Aß) accumulation, tauopathy, and neurodegeneration, were analyzed using enzyme-linked immunosorbent assay, Amylo-Glo staining, thioflavin-S staining, immunohistochemistry, Bielschowsky's staining, and western blot analysis. RESULTS: The AD COs exhibited extensive Aß accumulation. The levels of paired helical filament tau and neurofibrillary tangle-like silver deposits were highly increased in the AD COs. The number of cells immunoreactive for cleaved caspase-3 was significantly increased in the AD COs. In addition, treatment of AD COs with BACE1 inhibitor IV, a ß-secretase inhibitor, and compound E, a γ-secretase inhibitor, significantly attenuated the AD pathological features. CONCLUSION: Our model effectively recapitulates AD pathology. Hence, it is a valuable platform for understanding the mechanisms underlying AD pathogenesis and can be used to test the efficacy of anti-AD drugs.


Subject(s)
Alzheimer Disease , Amyloid beta-Peptides , Organoids , Pluripotent Stem Cells , Humans , Alzheimer Disease/metabolism , Alzheimer Disease/pathology , Alzheimer Disease/genetics , Organoids/metabolism , Organoids/pathology , Pluripotent Stem Cells/metabolism , Amyloid beta-Peptides/metabolism , Amyloid beta-Peptides/genetics , Amyloid Precursor Protein Secretases/metabolism , Amyloid Precursor Protein Secretases/genetics , Amyloid Precursor Protein Secretases/antagonists & inhibitors , tau Proteins/metabolism , tau Proteins/genetics , Aspartic Acid Endopeptidases/metabolism , Aspartic Acid Endopeptidases/genetics , Brain/metabolism , Brain/pathology , Models, Biological
9.
Biomed Opt Express ; 15(2): 834-842, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38404304

ABSTRACT

Terahertz (THz) electromagnetic waves, known for their unique response to water, offer promising opportunities for next-generation biomedical diagnostics and novel cancer therapy technologies. This study investigated the impedance-matching effect, which enhances the efficiency of THz wave delivery into tissues and compensates for the signal distortion induced by the refractive index mismatch between the target and the sample substrate. Three candidate biocompatible materials, water, glycerol, and petroleum jelly were applied to a skin phantom and compared using THz two-dimensional imaging and time-of-flight imaging methods. Finally, we successfully demonstrated impedance-matching effect on mouse skin tissues.

10.
Sensors (Basel) ; 24(3)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38339649

ABSTRACT

Terahertz (THz) waves are electromagnetic waves in the 0.1 to 10 THz frequency range, and THz imaging is utilized in a range of applications, including security inspections, biomedical fields, and the non-destructive examination of materials. However, THz images have a low resolution due to the long wavelength of THz waves. Therefore, improving the resolution of THz images is a current hot research topic. We propose a novel network architecture called J-Net, which is an improved version of U-Net, to achieve THz image super-resolution. It employs simple baseline blocks which can extract low-resolution (LR) image features and learn the mapping of LR images to high-resolution (HR) images efficiently. All training was conducted using the DIV2K+Flickr2K dataset, and we employed the peak signal-to-noise ratio (PSNR) for quantitative comparison. In our comparisons with other THz image super-resolution methods, J-Net achieved a PSNR of 32.52 dB, surpassing other techniques by more than 1 dB. J-Net also demonstrates superior performance on real THz images compared to other methods. Experiments show that the proposed J-Net achieves a better PSNR and visual improvement compared with other THz image super-resolution methods.

11.
Article in English | WPRIM (Western Pacific) | ID: wpr-1042751

ABSTRACT

Background@#The gait analysis method that has been used in clinical practice to date is an optical tracking system (OTS) using a marker, but a markerless gait analysis (MGA) system is being developed because of the expensive cost and complicated examination of the OTS. To apply this MGA clinically, a comparative study of the MGA and OTS methods is necessary. The purpose of this study was to evaluate the compatibility between the OTS and the MGA methods and to evaluate the usefulness of the MGA system in actual clinical settings. @*Methods@#From March 2021 to August 2021, 14 patients underwent gait analysis using the OTS and MGA system, and the spatiotemporal parameters and kinematic results obtained by the 2 methods were compared. To evaluate the practicality of the MGA system in an actual clinical setting, MGA was performed on 14 symptomatic children with idiopathic toe walking, who had been treated with a corrective cast, and the pre-cast and post-cast results were compared. For the OTS, the Motion Analysis Eagle system was used, and for MGA, DH Walk was used. @*Results@#The spatiotemporal parameters showed no significant difference between the OTS and MGA system. The joint angle graphs of the kinematics along the sagittal plane showed similar shapes as a whole, with particularly high correlations in the hip and knee (pelvis: 29.4%, hip joint: 96.7%, knee joint: 94.9%, and ankle joint: 68.5%). A quantified comparison using the CORrelation and Analysis (CORA) score also showed high similarity between the 2 methods. The MGA results of pre-cast application and post-cast removal for children with idiopathic toe walking showed a statistically significant improvement in ankle dorsiflexion after treatment (p < 0.001). @*Conclusions@#MGA showed a good correlation with the conventional OTS in terms of spatiotemporal parameters and kinematics. We demonstrated that ankle sagittal kinematics improved after treatment by corrective cast in children with idiopathic toe walking using the MGA method. Thus, after the improvement of a few limitations, the MGA system may soon be able to be clinically applied.

12.
Sensors (Basel) ; 23(19)2023 Sep 22.
Article in English | MEDLINE | ID: mdl-37836857

ABSTRACT

This study is the first to develop technology to evaluate the object recognition performance of camera sensors, which are increasingly important in autonomous vehicles owing to their relatively low price, and to verify the efficiency of camera recognition algorithms in obstruction situations. To this end, the concentration and color of the blockage and the type and color of the object were set as major factors, with their effects on camera recognition performance analyzed using a camera simulator based on a virtual test drive toolkit. The results show that the blockage concentration has the largest impact on object recognition, followed in order by the object type, blockage color, and object color. As for the blockage color, black exhibited better recognition performance than gray and yellow. In addition, changes in the blockage color affected the recognition of object types, resulting in different responses to each object. Through this study, we propose a blockage-based camera recognition performance evaluation method using simulation, and we establish an algorithm evaluation environment for various manufacturers through an interface with an actual camera. By suggesting the necessity and timing of future camera lens cleaning, we provide manufacturers with technical measures to improve the cleaning timing and camera safety.

14.
J Neuroeng Rehabil ; 20(1): 116, 2023 09 07.
Article in English | MEDLINE | ID: mdl-37679781

ABSTRACT

BACKGROUND: Autonomy support, which involves providing individuals the ability to control their own behavior, is associated with improved motor control and learning in various populations in clinical and non-clinical settings. This study aimed to investigate whether autonomy support combined with an information technology (IT) device facilitated success in using the more-affected arm during training in individuals with stroke. Consequently, we examined whether increased success influenced the use of the more-affected arm in mild to moderate subacute to chronic stroke survivors. METHODS: Twenty-six participants with stroke were assigned to the autonomy support or control groups. Over a 5-week period, training and test sessions were conducted using the Individualized Motivation Enhancement System (IMES), a device developed specifically for this study. In the autonomy support group, participants were able to adjust the task difficulty parameter, which controlled the time limit for reaching targets. The control group did not receive this option. The evaluation of the more-affected arm's use, performance, and impairment was conducted through clinical tests and the IMES. These data were then analyzed using mixed-effect models. RESULTS: In the IMES test, both groups showed a significant improvement in performance (p < 0.0001) after the training period, without any significant intergroup differences (p > 0.05). However only the autonomy support group demonstrated a significant increase in the use of the more-affected arm following the training (p < 0.001). Additionally, during the training period, the autonomy support group showed a significant increase in successful experiences with using the more-affected arm (p < 0.0001), while the control group did not exhibit the same level of improvement (p > 0.05). Also, in the autonomy support group, the increase in the use of the more-affected arm was associated with the increase in the successful experience significantly (p = 0.007). CONCLUSIONS: Combining autonomy support with an IT device is a practical approach for enhancing performance and promoting the use of the more-affected upper extremity post-stroke. Autonomy support facilitates the successful use of the more-affected arm, thereby increasing awareness of the training goal of maximizing its use. TRIAL REGISTRATION: The study was registered retrospectively with the Clinical Research Information Service (KCT0008117; January 13, 2023; https://cris.nih.go.kr/cris/search/detailSearch.do/23875 ).


Subject(s)
Arm , Stroke , Humans , Retrospective Studies , Upper Extremity , Motivation , Learning , Stroke/complications
15.
Adv Biol (Weinh) ; 7(12): e2300097, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37590305

ABSTRACT

Parkinson's disease (PD) is a complex condition that is significantly influenced by oxidative stress and inflammation. It is also suggested that telomere shortening (TS) is regulated by oxidative stress which leads to various diseases including age-related neurodegenerative diseases like PD. Thus, it is anticipated that PD would result in TS of peripheral blood mononuclear cells (PBMCs). Telomeres protect the ends of eukaryotic chromosomes preserving them against fusion and destruction. The TS is a normal process because DNA polymerase is unable to replicate the linear ends of the DNA due to end replication complications and telomerase activity in various cell types counteracts this process. PD is usually observed in the aged population and progresses over time therefore, disparities among telomere length in PBMCs of PD patients are recorded and it is still a question whether it has any useful role. Here, the likelihood of telomere attrition in PD and its implications concerning microglia activation, ageing, oxidative stress, and the significance of telomerase activators are addressed. Also, the possibility of telomeres and telomerase as a diagnostic and therapeutic biomarker in PD is discussed.


Subject(s)
Parkinson Disease , Telomerase , Humans , Aged , Parkinson Disease/diagnosis , Parkinson Disease/genetics , Parkinson Disease/therapy , Telomerase/genetics , Telomerase/metabolism , Leukocytes, Mononuclear/metabolism , Precision Medicine , Telomere/genetics , Telomere/metabolism
16.
Yonsei Med J ; 64(7): 413-422, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37365735

ABSTRACT

PURPOSE: The incidence and prognostic implications of atrial fibrillation (AF) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) are controversial, especially for Korean patients. Furthermore, the pattern of antithrombotic therapy for these patients is unknown. The present study sought to identify the impact of AF on Korean patients undergoing TAVI and demonstrate the status of antithrombotic therapy for these patients. MATERIALS AND METHODS: A total of 660 patients who underwent TAVI for severe AS were recruited from the nationwide K-TAVI registry in Korea. The enrolled patients were stratified into sinus rhythm (SR) and AF groups. The primary endpoint was all-cause death at 1-year. RESULTS: AF was recorded in 135 patients [pre-existing AF 108 (16.4%) and new-onset AF 27 (4.1%)]. The rate of all-cause death at 1 year was significantly higher in patients with AF than in those with SR [16.2% vs. 6.4%, adjusted hazard ratio (HR): 2.207, 95% confidence interval (CI): 1.182-4.120, p=0.013], regardless of the onset timing of AF. The rate of new pacemaker insertion at 1 year was also significantly higher in patients with AF than in those with SR (14.0% vs. 5.5%, adjusted HR: 3.137, 95%CI: 1.621-6.071, p=0.001). Among AF patients, substantial number of patients received the combination of multiple antithrombotic agents (77.8%), and the most common combination was that of aspirin and clopidogrel (38.1%). CONCLUSION: AF was an independent predictor of 1-year mortality and new pacemaker insertion in Korean patients undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Fibrinolytic Agents , Prognosis , Registries , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Treatment Outcome , Risk Factors
17.
Sensors (Basel) ; 23(5)2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36904952

ABSTRACT

Autonomous driving includes recognition, judgment, and control technologies, and is implemented using sensors such as cameras, LiDAR, and radar. However, recognition sensors are exposed to the outside environment and their performance may deteriorate because of the presence of substances that interfere with vision, such as dust, bird droppings, and insects, during operation. Research on sensor cleaning technology to solve this performance degradation has been limited. This study used various types and concentrations of blockage and dryness to demonstrate approaches to the evaluation of cleaning rates for selected conditions that afford satisfactory results. To determine the effectiveness of washing, the study used the following criteria: washer, 0.5 bar/s and air, 2 bar/s, with 3.5 g being used three times to test the LiDAR window. The study found that blockage, concentration, and dryness are the most important factors, and in that order. Additionally, the study compared new forms of blockage, such as those caused by dust, bird droppings, and insects, with standard dust that was used as a control to evaluate the performance of the new blockage types. The results of this study can be used to conduct various sensor cleaning tests and ensure their reliability and economic feasibility.

18.
Acta Cardiol ; 78(8): 880-888, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36942830

ABSTRACT

BACKGROUND: We investigated the effect of nicorandil on infarct size, cardiac function assessed by cardiac magnetic resonance imaging (CMR) and outcomes in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary percutaneous coronary intervention (PCI). METHODS: In a prospective, randomised, controlled trial, 83 patients with STEMI receiving primary PCI were randomised into the nicorandil (n =  40) or placebo (n  =  43) groups. Nicorandil was administered in the emergency room before primary PCI as an intravenous bolus of 4 mg followed by a continuous infusion of 6 mg/h for 24 h and as 2-mg intracoronary injections prior to balloon dilatation and coronary stenting. Nicorandil was continued orally at 10-20 mg/d for 6 months. Infarct size and cardiac function were measured by CMR at 5 d and 6 months after primary PCI. Furthermore, major adverse cardiac events (MACEs) including all-cause death, nonfatal myocardial infarction (MI), any revascularisation, stroke, and definite/probable stent thrombosis (ST) were compared. RESULTS: There were no significant differences in baseline clinical characteristics between the groups. Infarct size at baseline and 6 months as well as infarct size changes during 6 months as measured by CMR were similar between the groups. Similarly, other CMR parameters were comparable at baseline and 6 months between the groups. MACEs occurred in four patients (4.8%) during 6 months. No significant difference in the risk of MACEs was observed between the groups. CONCLUSIONS: Treatment with nicorandil for 6 months after primary PCI was not associated with any improvement in infarct size, CMR-determined cardiac function, and outcomes in STEMI patients.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/drug therapy , Nicorandil/therapeutic use , Prospective Studies , Treatment Outcome , Myocardial Infarction/therapy , Myocardial Infarction/drug therapy
19.
Medicine (Baltimore) ; 102(11): e33221, 2023 Mar 17.
Article in English | MEDLINE | ID: mdl-36930119

ABSTRACT

Cardiogenic shock (CS) is a common cause of death following acute myocardial infarction (MI). This study aimed to evaluate the adjusted mortality of venoarterial extracorporeal membrane oxygenation (VA-ECMO) with intra-aortic balloon counterpulsation (IABP) for patients with MI-CS. We included 300 MI patients selected from a multinational registry and categorized into VA-ECMO + IABP (N = 39) and no VA-ECMO (medical management ± IABP) (N = 261) groups. Both groups' 30-day and 1-year mortality were compared using the weighted Kaplan-Meier, propensity score, and inverse probability of treatment weighting methods. Adjusted incidences of 30-day (VA-ECMO + IABP vs No VA-ECMO, 77.7% vs 50.7; P = .083) and 1-year mortality (92.3% vs 84.8%; P = .223) along with propensity-adjusted and inverse probability of treatment weighting models in 30-day (hazard ratio [HR], 1.57; 95% confidence interval [CI], 0.92-2.77; P = .346 and HR, 1.44; 95% CI, 0.42-3.17; P = .452, respectively) and 1-year mortality (HR, 1.56; 95% CI, 0.95-2.56; P = .076 and HR, 1.33; 95% CI, 0.57-3.06; P = .51, respectively) did not differ between the groups. However, better survival benefit 30 days post-ECMO could be supposed (31.6% vs 83.4%; P = .022). Therefore, patients with MI-CS treated with IABP with additional VA-ECMO and those not supported with ECMO have comparable overall 30-day and 1-year mortality risks. However, VA-ECMO-supported survivors might have better long-term clinical outcomes.


Subject(s)
Extracorporeal Membrane Oxygenation , Myocardial Infarction , Humans , Shock, Cardiogenic/etiology , Extracorporeal Membrane Oxygenation/methods , Intra-Aortic Balloon Pumping/adverse effects , Myocardial Infarction/complications , Myocardial Infarction/therapy , Hospital Mortality , Retrospective Studies
20.
J Clin Med ; 12(6)2023 Mar 19.
Article in English | MEDLINE | ID: mdl-36983377

ABSTRACT

BACKGROUND: The introduction of a fixed-dose combination (FDC) is expected to improve treatment compliance. METHODS: There were 181 subjects who were randomized to three groups: ezetimibe-rosuvastatin 10/20 mg + telmisartan 80 mg, ezetimibe-rosuvastatin 10/20 mg, and telmisartan 80 mg. The primary outcomes were change in mean sitting systolic blood pressure (MSSBP) and percentage change in low-density-lipoprotein cholesterol (LDL-C) compared to baseline at week 8. RESULTS: The least-square mean (SE) in MSSBP changes between the ezetimibe-rosuvastatin 10/20 mg + telmisartan 80 mg group and the ezetimibe-rosuvastatin 10/20 mg group were -25.81 (2.34) mmHg and -7.66 (2.45) mmHg. There was a significant difference between the two groups (-18.15 (2.83) mmHg, 95% CI -23.75 to -12.56, p < 0.0001). Changes in least-square mean (SE) in LDL-C between the ezetimibe-rosuvastatin 10/20 mg + telmisartan 80 mg group and the telmisartan 80 mg group were -63.82 (2.87)% and -2.48 (3.12)%. A significant difference was observed between the two groups (-61.34 (3.33)%, 95% CI -67.91 to -54.78, p < 0.0001). No serious adverse events were observed. CONCLUSIONS: Ezetimibe-rosuvastatin plus telmisartan treatment is effective and safe when compared to either ezetimibe-rosuvastatin or telmisartan.

SELECTION OF CITATIONS
SEARCH DETAIL