1.
Life (Basel) ; 12(11)2022 Nov 18.
Article in English | MEDLINE | ID: mdl-36431058

ABSTRACT

Pre-treatment patient-specific quality assurance (QA) is critical to prevent radiation accidents. The electronic portal imaging device (EPID) is a dose measurement tool with good resolution and a low volume-averaging effect. EPIbeam­an EPID-based portal dosimetry software­has been newly installed in three institutions in Korea. This study evaluated the efficacy of the EPID-based patient-specific QA tool versus the PTW729 detector (a previously used QA tool) based on gamma criteria and planning target volume (PTV). A significant difference was confirmed through the R statistical analysis software. The average gamma passing rates of PTW729 and EPIbeam were 98.73% and 99.60% on 3 mm/3% (local), 96.66% and 97.91% on 2 mm/2% (local), and 88.41% and 74.87% on 1 mm/1% (local), respectively. The p-values between them were 0.015 (3 mm/3%, local), 0.084 (2 mm/2%, local), and less than 0.01 (1 mm/1%, local). Further, the average gamma passing rates of PTW 729 and EPIbeam according to PTV size were 99.55% and 99.91% (PTV < 150 cm3) and 97.91% and 99.28% (PTV > 150 cm3), respectively. The p-values between them were 0.087 (PTV < 150 cm3) and 0.036 (PTV > 150 cm3). These results confirm that EPIbeam can be an effective patient-specific QA tool.

2.
Technol Cancer Res Treat ; 20: 15330338211059937, 2021.
Article in English | MEDLINE | ID: mdl-34821195

ABSTRACT

OBJECTIVE: This study analyzed the correlation between the average segment width (ASW) and gamma passing rate according to the multi-leaf collimator (MLC) position error. METHOD: To evaluate the changes in the gamma passing rate according to the MLC position error, 21 volumetric modulated arc therapy (VMAT) plans were generated using pelvic lymph node metastatic prostate cancer patient's data which is sensitive to MLC position errors as they involve several long, narrow, irregular fields. The ASW for each VMAT plan was calculated using our own code developed using Visual Basic for Applications (VBA). The gamma passing rate of the VMAT plan according to the MLC position error was evaluated using ArcCHECK (Sun Nuclear, Melbourne, FL, USA) while inducing symmetric MLC position errors in 0.25 mm intervals from -1 mm to +1 mm in the infinity medical linear accelerator (Elekta AB, Stockholm, Sweden). Finally, we examined the correlation between the change in the passing rate (γgradient) due to the MLC position error and the ASW in VMAT through linear regression analysis using the least squares method. RESULTS: The ASW and γgradient were found to have a linear correlation according to the MLC position error, and the coefficient of determination was 0.88. For a 1 mm position error of MLC in VMAT, the gamma passing rate improved by approximately 11.9% as the ASW increased by 10 mm. CONCLUSION: These results are expected to be employed as guidelines to minimize the dose uncertainty due to MLC position error in VMAT.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Intensity-Modulated/standards , Algorithms , Clinical Decision-Making , Disease Management , Gamma Rays , Humans , Male , Pelvis/pathology , Pelvis/radiation effects , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/radiotherapy
3.
PLoS One ; 16(5): e0251441, 2021.
Article in English | MEDLINE | ID: mdl-34019553

ABSTRACT

Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor accuracy, because their attachment sites are approximated with the help of naked eyes. Therefore, a dosimeter based on a flexible material that can adjust to the contours of the human body is required. In this study, the reproducibility, linearity, dose-rate dependence, and percentage depth ionization (PDI) of PbO and HgO film-based dosimeters are evaluated to explore their potential as large-scale flexible dosimeters. The results demonstrate that both dosimeters deliver impressive reproducibility (within 1.5%) and linearity (≥ 0.9990). The relative standard deviations of the dose-rate dependence of the PbO and HgO dosimeters were 0.94% and 1.16% at 6 MeV, respectively, and 1.08% and 1.25% at 9 MeV, respectively, with the PbO dosimeter outperforming the 1.1% of existing diodes. The PDI analysis of the PbO and HgO dosimeters returned values of 0.014 cm (-0.074 cm) and 0.051 cm (-0.016 cm), respectively at 6 MeV (9 MeV) compared to the thimble chamber and R50. Therefore, the maximum error of each dosimeter is within the allowable range of 0.1 cm. In short, the analysis reveals that the PbO dosimeter delivers a superior performance relative to its HgO counterpart and has strong potential for use as a surface dosimeter. Thus, flexible monoxide materials have the necessary qualities to be used for dosimeters that meet the requisite quality assurance standards and can satisfy a variety of radiation-related applications as flexible functional materials.


Subject(s)
Electrons/therapeutic use , Film Dosimetry/methods , Equipment Design , Film Dosimetry/instrumentation , Humans , Lead/chemistry , Mercury Compounds/chemistry , Neoplasms/therapy , Oxides/chemistry