Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Comput Math Methods Med ; 2015: 389057, 2015.
Article in English | MEDLINE | ID: mdl-26089963

ABSTRACT

Ultrasound examination (US) does a key role in the diagnosis and management of the patients with clinically suspected appendicitis which is the most common abdominal surgical emergency. Among the various sonographic findings of appendicitis, outer diameter of the appendix is most important. Therefore, clear delineation of the appendix on US images is essential. In this paper, we propose a new intelligent method to extract appendix automatically from abdominal sonographic images as a basic building block of developing such an intelligent tool for medical practitioners. Knowing that the appendix is located at the lower organ area below the bottom fascia line, we conduct a series of image processing techniques to find the fascia line correctly. And then we apply fuzzy ART learning algorithm to the organ area in order to extract appendix accurately. The experiment verifies that the proposed method is highly accurate (successful in 38 out of 40 cases) in extracting appendix.


Subject(s)
Appendicitis/diagnostic imaging , Appendix/diagnostic imaging , Artificial Intelligence , Image Interpretation, Computer-Assisted/methods , Algorithms , Computational Biology , Fuzzy Logic , Humans , Neural Networks, Computer , Ultrasonography , Unsupervised Machine Learning
2.
J Nanosci Nanotechnol ; 15(10): 7866-70, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26726430

ABSTRACT

Poly(glycidyl methadrylate-block-styrene) (PGMA-b-PS), a block copolymer consisting of glycidyl methacrylate and styrene, was synthesized via reversible addition-fragmentation chain transfer living polymerization. The synthesized PGMA-b-PS was then grafted with low-molecular-weight polyethylene glycol (PEG) via epoxy ring opening to give PGMA-g-PEG-b-PS, which was evaluated as an anti-biofouling coating material. As a preliminary test for the anti-biofouling effect, a protein adsorption experiment was performed on the synthesized block copolymer surface. The block copolymers were spin-coated onto silicon wafers, and protein adsorption experiments were carried out using fluorescein isothiocyanate conjugate-labeled bovine serum albumin. The fluorescence intensity of the protein adsorbed on the block copolymer surface was compared with that of a polystyrene film as a reference. The synthesized PGMA-g-PEG-b-PS film showed much lower fluorescence intensity than that of the PS film.


Subject(s)
Biofouling/prevention & control , Epoxy Compounds/chemistry , Methacrylates/chemistry , Propylene Glycols , Serum Albumin, Bovine/chemistry , Styrene/chemistry , Adsorption , Animals , Cattle , Propylene Glycols/chemical synthesis , Propylene Glycols/chemistry
3.
J Ultrasound Med ; 29(12): 1687-97, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21098839

ABSTRACT

OBJECTIVE: The purpose of this study was to differentiate between high-grade and non-high-grade ductal carcinoma in situ (DCIS) of the breast on sonography. METHODS: From October 2003 to August 2009, 76 DCIS lesions in 73 women who underwent sonography and mammography were included in this study. Lesions were confirmed by mastectomy, breast-conserving surgery, or surgical biopsy. Images were analyzed by 2 radiologists with consensus and were correlated with histologic grades. RESULTS: Of the 76 lesions, 44 were classified as high--grade and 32 as non-high-grade DCIS. Fifty-seven lesions (75.0%) were identified on sonography, which revealed a mass in 30 cases, microcalcifications in 20, ductal changes in 4, and architectural distortion in 3. All cases with false-negative findings on sonography (n = 19) showed microcalcifications on mammography. On sonography, masses were more frequently found in non-high-grade (62.5%) than high-grade DCIS (22.7%; P < .01). No significant difference was seen in the sonographic features of masses between high-grade and non-high-grade DCIS. Microcalcifications were more common in high-grade (43.2%) than non-high-grade (3.1%) DCIS (P = .02). Most sonographically visible microcalcifications had associated findings such as ductal changes (n = 11), a mass (n = 7), or a hypoechoic area (n = 5). The detection rate of microcalcifications on sonography was higher in high-grade (62.9%) than non-high-grade DCIS (25.0%; P = .023). CONCLUSIONS: Microcalcifications with associated ductal changes (11 of 31 [35.5%]) were the most common sonographic findings in high-grade DCIS. An irregular hypoechoic mass with an indistinct and microlobulated margin (13 of 26 [50.0%]) was the most frequent finding in non-high-grade DCIS.


Subject(s)
Breast Neoplasms/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Ultrasonography, Mammary , Adult , Aged , Aged, 80 and over , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Calcinosis , Carcinoma, Intraductal, Noninfiltrating/metabolism , Carcinoma, Intraductal, Noninfiltrating/pathology , Female , Humans , Immunohistochemistry , Middle Aged , Receptors, Estrogen/metabolism , Receptors, Progesterone/metabolism , Retrospective Studies
4.
J Vasc Interv Radiol ; 21(3): 348-56, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20116285

ABSTRACT

PURPOSE: To assess the diagnostic value of gadoxetic acid-enhanced magnetic resonance (MR) imaging in follow-up of patients with hepatocellular carcinomas (HCCs) who were treated with radiofrequency (RF) ablation and to compare it with that of four-phase multi-detector row computed tomography (CT). MATERIALS AND METHODS: From July 2007 to May 2008, 36 patients (43 HCCs) were enrolled who were treated with RF ablation (tumor size, 20-47 mm; mean, 24.5 mm) and underwent gadoxetic acid-enhanced MR imaging and four-phase (precontrast, arterial, portal venous, and equilibrium) multidetector CT for follow-up. Two radiologists independently reviewed these images, and conspicuity of tumor margins and detection of residual or recurrent tumor were assessed on a five-point scale with receiver operating characteristic (ROC) curve analysis. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were evaluated. RESULTS: The mean conspicuity value of tumor margins was significantly higher on MR imaging than on multidetector CT (P < .001). The degree of differentiation between residual/recurrent tumor and hyperemia was significantly greater on MR imaging (P < .001). The mean area under the ROC curve was significantly higher with MR imaging (P = .015), as were sensitivity, specificity, PPV, NPV, and accuracy of detection rate (mean, 100%, 96.2%, 82.4%, 100%, and 96.7%, respectively, vs 41.7%, 56.8%, 13.5%, 85.7%, and 54.7% for multidetector CT). The interobserver agreement rate for MR imaging was higher (0.919) than for multidetector CT (0.672; P < .05). CONCLUSIONS: Diagnostic accuracy, conspicuity of tumor margins, and detection rate of residual or recurrent tumor were found to be better with gadoxetic acid-enhanced MR imaging than with four-phase multidetector CT.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Carcinoma, Hepatocellular/surgery , Gadolinium DTPA , Liver Neoplasms/diagnosis , Liver Neoplasms/surgery , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
6.
Radiographics ; 23(1): 123-34; discussion 134-6, 2003.
Article in English | MEDLINE | ID: mdl-12533647

ABSTRACT

Although radio-frequency (RF) ablation has been accepted as a promising and safe technique for treatment of unresectable hepatic tumors, investigation of its complications has been limited. According to the multicenter (1,139 patients in 11 institutions) survey data of the Korean Study Group of Radiofrequency Ablation, a spectrum of complications occurred after RF ablation of hepatic tumors. The prevalence of major complications was 2.43%. The most common complications were hepatic abscess (0.66%), peritoneal hemorrhage (0.46%), biloma (0.20%), ground pad burn (0.20%), pneumothorax (0.20%), and vasovagal reflex (0.13%). Other complications were biliary stricture, diaphragmatic injury, gastric ulcer, hemothorax, hepatic failure, hepatic infarction, renal infarction, sepsis, and transient ischemic attack. One procedure-related death (0.09%) occurred (due to peritoneal hemorrhage). Three important strategies for decreasing the rate of complications are prevention, early detection, and proper management. A physician who performs RF ablation of hepatic malignancies should be aware of the broad spectrum of major complications so that these strategies can be used.


Subject(s)
Catheter Ablation/adverse effects , Liver Neoplasms/surgery , Postoperative Complications/epidemiology , Aged , Burns/epidemiology , Female , Humans , Liver Abscess/epidemiology , Male , Middle Aged , Pneumothorax/epidemiology , Postoperative Hemorrhage/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...