Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Dis Markers ; 2019: 1369798, 2019.
Article in English | MEDLINE | ID: mdl-31915467

ABSTRACT

BACKGROUND: Patients with liver cirrhosis have a high risk of sepsis and a poor prognosis. Recently, a new standard for sepsis (Sepsis-3) has been proposed in the general population. The Coulter Lh 750 hematology analyzer can evaluate mean volume, conductivity, scatter, and distribution width of leukocyte. We tried to use Sepsis-3 criteria to study the diagnostic value of volume, conductivity, and scattering (VCS) parameters in sepsis and infection in patients with liver cirrhosis compared with traditional infection markers (PCT, IL-6, sCDl63). METHODS: A blinded, cohort study was conducted in three different ED populations within three affiliated hospitals. A total of 249 patients with liver cirrhosis were enrolled in the study. According to the "Sepsis-3" consensus criteria, clinical history, and laboratory examination, the subjects were divided into sepsis (n = 54), patients with infections (n = 95), and patients without systemic infections (n = 100). The blood samples of the patients were collected at the time of ED admission and were evaluated for the detection of sepsis. RESULTS: The differences of MNV, MNS, MMV, MMS, MLV, NDW, and MDW in the three groups were statistically significant. In the diagnosis of sepsis in patients with liver cirrhosis, the sensitivity of combined detection of MMV and MDW was 88.89%; the specificity was 74%. This sensitivity was significantly better than the 83.3% achieved using 0.97 mg/L as the cutoff for sCD163. In the diagnosis of infection in cirrhosis, the sensitivity of combination of MNV and MMS was increased to 86.32%; the specificity was 92%. The sensitivity was the same as that achieved by using 0.31 ng/mL as the cutoff value of PCT, but the specificity increased. CONCLUSION: The leukocyte VCS parameter could be potential parameters for indicating sepsis and infection in patients with liver cirrhosis. The combined detection of MMV and MDW seemed to be helpful for the diagnosis of sepsis in these patients, and the combination of MNV and MMS could better indicate infection for them.


Subject(s)
Biomarkers/blood , Liver Cirrhosis/blood , Liver Cirrhosis/complications , Sepsis/diagnosis , Adult , Aged , Antigens, CD/blood , Antigens, Differentiation, Myelomonocytic/blood , Blood Volume , Early Diagnosis , Female , Humans , Interleukin-6/blood , Leukocyte Count , Liver Cirrhosis/metabolism , Male , Middle Aged , Procalcitonin/blood , Receptors, Cell Surface/blood , Retrospective Studies , Sensitivity and Specificity , Sepsis/blood , Sepsis/etiology
2.
J Biomol Tech ; 27(4): 132-137, 2016 12.
Article in English | MEDLINE | ID: mdl-27672351

ABSTRACT

Extended-spectrum ß-lactamase (ESBL) genes that render bacteria resistant to antibiotics are commonly detected using phenotype testing, which is time consuming and not sufficiently accurate. To establish a better method, we used phenotype testing to identify ESBL-positive bacterial strains and conducted PCR to screen for TEM (named after the patient Temoneira who provided the first sample), sulfhydryl reagent variable (SHV), cefotaxime (CTX)-M-1, and CTX-M-9, the 4 most common ESBL types and subtypes. We then performed multiplex PCR with 1 primer containing a biotin and hybridized the PCR products with gene-specific probes that were coupled with microbeads and coated with a specific fluorescence. The hybrids were linked to streptavidin-R-phycoerythrins (SA-PEs) and run through a flow cytometer, which sorted the fluorescently dyed microbeads and quantified the PEs. The results from single PCR, multiplex PCR, and cytometry were consistent with each other. We used this method to test 169 clinical specimens that had been determined for phenotypes and found 154 positive for genotypes, including 30 of the 45 samples that were negative for phenotypes. The CTX-M genotype tests alone, counting both positive and negative cases, showed 99.41% (168/169) consistency with the ESBL phenotype test. Thus, we have established a multiplex-PCR system as a simple and quick method that is high throughput and accurate for detecting 4 common ESBL types and subtypes.


Subject(s)
Escherichia coli Infections/diagnosis , Escherichia coli Proteins/genetics , Molecular Diagnostic Techniques , beta-Lactamases/genetics , Escherichia coli/enzymology , Escherichia coli/genetics , Escherichia coli Infections/microbiology , Genes, Bacterial , Humans , Klebsiella pneumoniae/enzymology , Klebsiella pneumoniae/genetics , Multiplex Polymerase Chain Reaction , Reproducibility of Results , beta-Lactam Resistance/genetics
SELECTION OF CITATIONS