Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
In Vivo ; 37(5): 2340-2346, 2023.
Article in English | MEDLINE | ID: mdl-37652492

ABSTRACT

BACKGROUND/AIM: To investigate the association between the thyroid dysfunction and thyroid radiation dose in regional nodal irradiation (RNI) using volumetric modulated arc therapy (VMAT) for breast cancer. PATIENTS AND METHODS: We reviewed medical data of 67 patients with breast cancer who underwent curative surgery followed by adjuvant radiotherapy, including RNI using VMAT, between 2018 and 2021. All patients had normal thyroid functional test results, including thyroid stimulating hormone (TSH), T3, and free-T4. We defined subclinical hypothyroidism as increased TSH with or without decreased levels of free-T4 and T3 after the completion of VMAT. We calculated dose-volume histogram parameters (DVHPs), including the mean dose and relative thyroid volume receiving at least 10, 20, 30, and 40 Gy. RESULTS: The median follow-up time was 23.2 months. The 3-year locoregional failure-free survival, progression-free survival, and overall survival rates were 96.3%, 94.7%, and 96.2%, respectively. The mean thyroid dose was 21.4 Gy (range=11.5-29.4 Gy). Subclinical hypothyroidism was noted in 14 patients (20.9%) and the median time to the event was 4.1 months. Among the DVHPs, the relative volume receiving ≥20 Gy (V20Gy) was associated with subclinical hypothyroidism. The 2-year rates of subclinical hypothyroidism were 24.8% and 59.1% in patients with V20Gy ≤46.3% and >46.3%, respectively. CONCLUSION: A significant proportion of patients with breast cancer developed subclinical hypothyroidism after undergoing VMAT for RNI. Our findings highlight the importance of considering the thyroid as an organ at risk for VMAT planning, and suggest that V20Gy could be a useful dose-volume constraint.


Subject(s)
Breast Neoplasms , Hypothyroidism , Radiotherapy, Intensity-Modulated , Humans , Female , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Breast Neoplasms/complications , Breast Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiation Dosage , Hypothyroidism/etiology , Thyrotropin
2.
In Vivo ; 36(4): 1937-1943, 2022.
Article in English | MEDLINE | ID: mdl-35738635

ABSTRACT

BACKGROUND/AIM: To evaluate the early effect of radiation dose on liver function in breast cancer patients undergoing free-breathing volumetric modulated arc therapy (FB-VMAT). PATIENTS AND METHODS: Medical records of 125 patients with breast cancer who underwent curative surgery followed by postoperative radiotherapy using FB-VMAT during 2018-2021 were reviewed. Results of the liver function test (LFT), performed within 1-week before and 6-months after radiotherapy, were collected and compared. The LFTs analyzed albumin, total and direct bilirubin, aspartate transaminase, alanine transferase, and alkaline phosphatase levels. The mean dose and relative liver volume receiving at least 10 Gy, 20 Gy, or 30 Gy were calculated. RESULTS: Median follow-up time was 21.4 months. One patient experienced locoregional and distant failures. The mean liver irradiation dose was 325.9 centigray (cGy) for all patients. The liver irradiation dose was higher in patients with right breast cancer than in those with left breast cancer (mean, 434.1 cGy vs. 260.6 cGy, p<0.001). Direct bilirubin and aspartate transaminase levels showed significant differences after FB-VMAT. LFT results outside normal limits were noted in 31 patients at follow-up, but nobody met the criteria of radiation-induced liver disease. Underlying liver disease, breast laterality, systemic treatment, or dose-volume histogram parameters were not associated with abnormal LFT results. CONCLUSION: FB-VMAT can deliver radiation doses safely without adversely affecting the liver. The mean dose ≤4 Gy could be a useful dose criterium of the liver for FB-VMAT plans.


Subject(s)
Breast Neoplasms , Liver , Radiotherapy, Intensity-Modulated , Aspartate Aminotransferases , Bilirubin , Breast Neoplasms/etiology , Breast Neoplasms/radiotherapy , Female , Humans , Liver/radiation effects , Radiation Dosage , Radiation Injuries/diagnosis , Radiation Injuries/etiology , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods
3.
J Breast Cancer ; 17(1): 69-75, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24744800

ABSTRACT

PURPOSE: This study was performed to assess frequency, timings of occurrence, and predictors of radiologic lung damage (RLD) after forward-planned intensity-modulated radiotherapy (FIMRT) for whole breast irradiation. METHODS: We retrospectively reviewed medical records of 157 breast cancer patients and each of their serial chest computed tomography (CT) taken 4, 10, 16, and 22 months after completion of breast radiotherapy (RT). FIMRT was administered to whole breast only (n=152), or whole breast and supraclavicular regions (n=5). Dosimetric parameters, such as mean lung dose and lung volume receiving more than 10 to 50 Gy (V10-V50), and clinical parameters were analyzed in relation to radiologic lung damage. RESULTS: In total, 104 patients (66.2%) developed RLD after whole breast FIMRT. Among the cases of RLD, 84.7% were detected at 4 months, and 15.3% at 10 months after completion of RT. More patients of 47 or younger were found to have RLD at 10 months after RT than patients older than the age (11.7% vs. 2.9%, p=0.01). In univariate and multivariate analyses, age >47 and V40 >7.2% were significant predictors for higher risk of RLD. CONCLUSION: RLD were not infrequently detected in follow-up CT after whole breast FIMRT. More detected cases of RLD among younger patients are believed to have developed at later points after RT than those of older patients. Age and V40 were significant predictors for RLD after whole breast intensity-modulated radiotherapy.

4.
J Radiat Res ; 54(1): 174-81, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22915776

ABSTRACT

Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size as the tungsten eye shield was machined and CT scanned. The BEAMnrc and the DOSXYZnrc were used for the Monte Carlo (MC) simulation, with the appropriate material information and density for the aluminum cover, steel knob and tungsten body of the eye shield. The Pinnacle adopting the Hogstrom electron pencil-beam algorithm was used for the one-port 6-MeV beam plan after delineation and density override of the metallic parts. The results were confirmed with the metal oxide semiconductor field effect transistor (MOSFET) detectors and the Gafchromic EBT2 film measurements. For both the maximum eyelid dose over the shield and the maximum dose under the shield, the MC results agreed with the EBT2 measurements within 1.7%. For the Pinnacle plan, the maximum dose under the shield agreed with the MC within 0.3%; however, the eyelid dose differed by -19.3%. The adoption of the acrylic dummy eye shield was successful for the treatment plan. However, the Pinnacle pencil-beam algorithm was not sufficient to predict the eyelid dose on the tungsten shield, and more accurate algorithms like MC should be considered for a treatment plan.


Subject(s)
Eye Injuries/prevention & control , Eye Protective Devices , Eyelid Neoplasms/radiotherapy , Radiation Injuries/prevention & control , Radiation Protection/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/adverse effects , Electrons/therapeutic use , Equipment Design , Equipment Failure Analysis , Eye Injuries/etiology , Eyelid Neoplasms/complications , Humans , Radiation Injuries/etiology , Radiotherapy Dosage , Treatment Outcome
5.
Med Phys ; 39(5): 2524-35, 2012 May.
Article in English | MEDLINE | ID: mdl-22559623

ABSTRACT

PURPOSE: The authors aim was to investigate the effects of using transmission and reflection scanning modes, the film orientation during scanning, and ambient room light on a dosimetry system based on the Gafchromic(TM) EBT2 film model. METHODS: For calibration, the films were cut to 3 × 3 cm(2) and irradiated from 20 to 700 cGy at the depth of maximum dose using 6 and 10 MV photon beams in a 10 × 10 cm(2) field size. Absolute dose calibration of the linear accelerator was done according to the TRS398 protocol. An FG65-G ionization chamber was used to monitor the dose while irradiating the films in solid water. The film pieces were scanned with an EPSON Expression 1680 Pro flatbed scanner in transmission and reflection modes. Authors investigated the effect of orientation on films and examined the optical properties of EBT2 film using an ellipsometer and an ultraviolet (UV)/visible spectrometer to explain the dosimetric dependence of the film on orientation during the scanning process. To investigate the effect of ambient room light, films were preirradiated in 6 and 10 MV photon beams with intensity-modulated radiotherapy (IMRT) quality assurance (QA) plans, and then exposed to room light, either directly for 2 days in a workroom or for 2 months in a film box. Gamma index pass criteria of (3%, 3 mm) were used. RESULTS: The dose response curves based on net optical density (NOD) indicated that the reflection scanning mode can provide a better dose sensitivity than the transmission scanning mode, whereas the standard deviation of the dose is greater in reflection mode than in transmission mode. When the film was rotated 90° from the portrait orientation, the average dose of the EBT2 film decreased by 11.5-19.6% in transmission mode and by 1.5-2.3% in reflection mode. Using an ellipsometer, variation of the refractive index of EBT2 film-the birefringence property-was found to be the largest between 45° (1.72 and 1.71) and 135° (1.8 and 1.77) for 300 and 800 cGy. Absorption spectra of EBT2 films measured with spectrometer were the function of film orientation. The readings in reflection scanning mode were more stable against room light than those in transmission scanning mode, although dose readings increased in both modes after the films were exposed to room light. CONCLUSIONS: The transmission scanning mode exhibited a strong dependence on film orientation during scanning and a change in optical density resulting from room light exposure, so a constant scanning orientation and minimal exposure to light can reduce uncertainty in the measured dose (23 ± 3%). The angular dependence was analyzed using Jones matrices and optical properties of EBT2 film were obtained using an ellipsometer and an UV/visible spectrometer. The reflection scanning mode has relatively good stability with respect to room light and film orientation on a scanner, although the large standard deviation of dose is a disadvantage in measurements of absolute dose. Reflection scanning mode can offer a potential advantage for film dosimetry in radiotherapy, although transmission scanning mode is still recommended for dosimetry as it provides better uncertainty results.


Subject(s)
Film Dosimetry/methods , Optical Phenomena , Radiation Dosage , Film Dosimetry/instrumentation , Light
6.
J Clin Oncol ; 27(30): 5088-93, 2009 Oct 20.
Article in English | MEDLINE | ID: mdl-19770372

ABSTRACT

PURPOSE: To evaluate whether human papillomavirus (HPV) viral load measured in cervical smear and HPV type 18 are associated with radiotherapy outcomes in uterine cervical cancer. PATIENTS AND METHODS HPV DNA: was semiquantitatively measured in the cervical smears of 169 radiotherapy patients. HPV viral load was classified as low or high according to median HPV DNA titer and examined for its prognostic value. The multivariable Cox proportional hazards model was used to adjust for covariates. A relapse-predicting model was constructed to classify three risk groups for disease-free survival (DFS), which were used for internal validation. RESULTS: Patients with lower HPV viral load showed worse DFS in univariate analysis. HPV type 18, younger patient age, stage group, nodal status, histologic grade, and histologic type were other prognostic factors for poor DFS. Among these factors, all except stage group were associated with HPV viral load. Multivariate analysis showed the strong influence of HPV viral load for poor DFS. The prognostic model developed using our outcome data performed well in predicting the risk of relapse. CONCLUSION: Our data suggest that HPV viral load is a strong independent prognostic factor for DFS. HPV type 18 showed a significant relationship with poor radiotherapy outcome in univariate analysis, but not in multivariate analysis.


Subject(s)
Adenocarcinoma/virology , Carcinoma, Squamous Cell/virology , Human papillomavirus 18/isolation & purification , Papillomavirus Infections/virology , Uterine Cervical Neoplasms/virology , Viral Load , Adenocarcinoma/pathology , Adenocarcinoma/radiotherapy , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/radiotherapy , DNA, Viral/genetics , Female , Human papillomavirus 18/genetics , Humans , Middle Aged , Prognosis , Uterine Cervical Neoplasms/pathology , Uterine Cervical Neoplasms/radiotherapy , Vaginal Smears , Young Adult
7.
Radiother Oncol ; 92(1): 138-41, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19368986

ABSTRACT

We report the case of a 32-year-old woman who presented with multiple squamous cell neoplasms synchronously arising in the cervix, vulva, oral cavity and oropharynx. During the period when the patient was treated by radiotherapy, she developed severe radiation mucositis and pancytopenia. Immunofluorescence staining for foci of the monoubiquitinated form of FANCD2 revealed a complete absence of such foci in all cancer tissues that were examined.


Subject(s)
Carcinoma, Squamous Cell/complications , Fanconi Anemia/complications , Genital Neoplasms, Female/complications , Head and Neck Neoplasms/complications , Papillomavirus Infections/complications , Adult , Carcinoma, Squamous Cell/virology , Female , Genital Neoplasms, Female/virology , Head and Neck Neoplasms/virology , Humans , Papillomavirus Infections/virology
SELECTION OF CITATIONS
SEARCH DETAIL
...