1.
Heart Rhythm ; 21(6): 790-798, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38336196

ABSTRACT

BACKGROUND: Bipolar radiofrequency ablation (B-RFA) is a method used to treat the arrhythmia substrate resistant to unipolar ablation. Few studies have addressed endo-epicardial B-RFA. OBJECTIVE: The aim of the study was to evaluate chronic lesions resulting from endo-epicardial B-RFA and to determine optimal settings for such procedures in an animal model. METHODS: In 7 pigs, up to 5 radiofrequency applications per animal were performed with 2 electrodes placed on both sides of the left ventricular free wall. Current was delivered for 60 seconds by a generator dedicated for B-RFA with power settings of 25, 30, 35, 40, and 50 W. RESULTS: At 12 weeks after ablation, 31 lesions were assessed. Their maximal cross-sectional area ranged from 7.2 to 68 mm2 and correlated with total power delivered (r = 0.53), with temperature increment at the endocardial catheter (r = 0.65), and inversely with temperature decrement at the epicardial catheter (r = 0.54). For power values between 30 and 40 W, the lesion area did not differ significantly (P = .92). Lesion depth ranged from 1.9 to 11 mm and correlated with impedance decrement (r = 0.5). Lesions were transmural in 8 cases. Lesion depth/wall thickness ratio was on average 0.6 ± 0.3, with the smallest value for 25 W (0.5 ± 0.3) and the largest for 50 W (0.8 ± 0.3). Steam pops occurred at a power range of 30-50 W, with an incidence of 1 in 5 applications, with 1 case of fatal tamponade at 40 W. Impedance decrement, endocardial catheter temperature increment, and endocardial electrogram amplitude decrement were greater during applications with steam pops. CONCLUSION: Chronic lesions resulting from endo-epicardial B-RFA appear smaller and less often transmural compared with acute lesions described in the literature. The incidence of steam pops during endo-epicardial B-RFA is relatively high even at low powers.


Subject(s)
Catheter Ablation , Disease Models, Animal , Endocardium , Feasibility Studies , Pericardium , Animals , Swine , Pericardium/surgery , Endocardium/surgery , Catheter Ablation/methods , Heart Ventricles/physiopathology , Equipment Design
3.
J Cardiovasc Electrophysiol ; 34(1): 35-43, 2023 01.
Article in English | MEDLINE | ID: mdl-36217991

ABSTRACT

INTRODUCTION: Variability of the bipolar atrial electrogram amplitude may affect voltage maps created during ablation procedures, and thus also the extent of ablations. Therefore, the aim of the study was to assess the beat-to-beat electrogram amplitude variability in the left atrium in patients undergoing atrial fibrillation ablation. METHODS: In 11 patients undergoing ablation for atrial fibrillation, 362 mapping points were collected in two series. At each point, three consecutive beats were recorded and verified including the bipolar electrogram amplitude, contact force (CF), and orientation of the catheter tip. The repeatability and reproducibility of obtained measurements between consecutive beats and series were assessed by the Pearson correlation coefficient (r), the Bland-Altman test, repeatability coefficient (RC), relative standard deviation (RSD), and concordance correlation coefficient (CCC). RESULTS: A total of 1086 beats were analyzed. The correlation coefficient for bipolar atrial electrogram amplitude for the first two beats, and for the first and the third beats were 0.94 and 0.86, respectively. The average of differences between the first two beats and between the first and the third beats were 0.06 and 0.13 mV with 95% limits of agreement (LoA) within ±0.98 and ±1.74 mV, respectively. For CF values ≤5 and ≥20 g, the 95% LoA were narrower compared to other CF ranges and were ±0.49 and ±0.71 mV from the average value, respectively. When the analyzes were performed within the predefined ranges of bipolar electrogram amplitude: 0.05-1; 1-2; 2-3 mV, the 95% LoA were within ±0.33, ±0.98, and ±0.84 mV from the average value, respectively. RC and RSD were 1.41 mV and 20.8%, respectively. For repeated measurement between series, CCC ranged from 0.67 to 0.71 and the 95% LoA were within ±2.7 to 2.9 mV from the average value. CONCLUSION: Bipolar atrial electrogram amplitude recorded at a given site during ablation procedures is variable to an extent that may be clinically relevant. The magnitude of the observed variability is greater during remapping.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac/methods , Reproducibility of Results , Heart Atria , Catheter Ablation/adverse effects , Catheter Ablation/methods