Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Leuk Lymphoma ; 48(8): 1531-8, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17701584

ABSTRACT

F-18-fluoro-deoxy-glucose positron emission tomography (PET) is highly sensitive and specific in the imaging of B-cell lymphomas. In contrast, its utility in the diagnostic evaluation of T-cell lymphomas is less defined. In this article, we present our finding utilizing PET in peripheral T-cell lymphomas (PTCL). A retrospective review of patients who underwent PET examinations at our institution produced 24 PET examinations among patients with PTCL. A lesion-based analysis was undertaken to evaluate the diagnostic accuracy of PET in PTCL. PET findings were compared with a standard of reference and sensitivity, specificity, positive and negative predictive values were calculated. PET had an overall sensitivity of 86% and specificity of 100%. PET had high sensitivity (95%) at nodal and non-cutaneous extra-nodal sites and poor sensitivity (13%) at cutaneous sites. The mean SUV of abnormal foci in anaplastic large cell lymphoma was 11 mg/ml (range: 3 - 40), and PTCL-unclassified was 8 mg/ml (range: 1 - 23).


Subject(s)
Fluorodeoxyglucose F18 , Lymphoma, T-Cell, Peripheral/diagnostic imaging , Positron-Emission Tomography , Radiopharmaceuticals , Adolescent , Adult , Aged , Aged, 80 and over , Disease-Free Survival , Female , Humans , Lymphoma, T-Cell, Cutaneous/diagnostic imaging , Lymphoma, T-Cell, Cutaneous/drug therapy , Lymphoma, T-Cell, Peripheral/drug therapy , Male , Middle Aged , Neoplasm Staging , Retrospective Studies , Sensitivity and Specificity , Survival Rate , Tomography, X-Ray Computed , Treatment Outcome
2.
Nebr Med J ; 77(2): 26-8; discussion 29, 1992 Feb.
Article in English | MEDLINE | ID: mdl-1574155

ABSTRACT

The sensitivity of electrocardiographic ST analysis for detecting coronary artery disease is markedly decreased in patients unable to exercise vigorously. To determine the diagnostic accuracy of Thallium-201 SPECT scintigraphy at various exercise levels, we evaluated 179 patients without evidence of prior myocardial infarction or other confounding factors who performed symptom-limited exercise with Thallium-201 SPECT scintigraphy. Sensitivity decreased from 89% in those patients achieving greater than or equal to 85% of maximal heart rate to 63% in those achieving less than 65%. Like ST segment analysis, Thallium 201 SPECT scintigraphy has decreased diagnostic yield at low levels of exertion.


Subject(s)
Coronary Disease/diagnostic imaging , Exercise , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Aged , Coronary Disease/physiopathology , Female , Humans , Male , Middle Aged , Sensitivity and Specificity
3.
Am Heart J ; 119(2 Pt 1): 272-6, 1990 Feb.
Article in English | MEDLINE | ID: mdl-2137278

ABSTRACT

Although exercise-induced ST segment depression is thought to be unreliable marker of myocardial ischemia in the presence of resting electrocardiographic changes, this conclusion is based on limited and disparate data from studies often lacking acceptable measures of ischemia. To determine the diagnostic accuracy of the ST segment response in a blinded prospective protocol, we compared ST deviation to thallium201 SPECT scintigraphy in 95 patients during exercise. Diagnostic accuracy was poor in the 95 patients with resting abnormalities: left bundle branch block (LBBB) = 70%, complete right bundle branch block (cRBBB) = 75%, incomplete right bundle branch block (incRBBB) = 79%, intraventricular conduction delay (IVCD) = 44%, left ventricular hypertrophy (LVH) = 59%, digitalis = 53%, compared with a diagnostic accuracy of 90% in 29 patients without resting changes. There were 20 false negative and 17 false positive ST segment responses. The extent and direction of resting ST deviation varied substantially and had no influence on diagnostic accuracy. The extent of change in ST deviation with exercise required for a positive response did not alter diagnostic accuracy: -1.0 mm = 61%, -1.5 mm = 63%, and -2.0 = 61%. While the location of regional ischemia did not influence the accuracy of ST segment analysis, a QRS duration less than 120 msec did improve diagnostic accuracy. Our data confirm that ST segment analysis with exercise testing is not reliable in patients with resting electrocardiographic abnormalities and demonstrates that accuracy is not improved by adjusting for either resting or exercise-induced ST segment changes or for location of the ischemic region.


Subject(s)
Coronary Disease/diagnosis , Electrocardiography , Exercise Test , Aged , Angiography , Bundle-Branch Block/physiopathology , Cardiomegaly/physiopathology , Coronary Angiography , Coronary Disease/diagnostic imaging , Coronary Disease/physiopathology , Digoxin/pharmacology , Female , Heart/drug effects , Heart/physiopathology , Humans , Male , Middle Aged , Prognosis , Prospective Studies , Rest , Tomography, Emission-Computed, Single-Photon
4.
Clin Nucl Med ; 9(1): 17-9, 1984 Jan.
Article in English | MEDLINE | ID: mdl-6697613

ABSTRACT

Two patients are reported who presented with clinical hyperthyroidism, increased serum thyroid function studies, and depressed radioactive iodine uptake, secondary to chronic ingestion of D-T4. Symptoms abated, and function studies returned to normal, following discontinuation of D-T4. This uncommon effect of D-T4 may be more prevalent than is generally realized and must be recognized as another potential cause of low radioiodine uptake in patients with clinical hyperthyroidism.


Subject(s)
Dextrothyroxine/adverse effects , Hyperthyroidism/chemically induced , Aged , Female , Humans , Hypercholesterolemia/drug therapy , Hyperthyroidism/radiotherapy , Iodine Radioisotopes/metabolism , Iodine Radioisotopes/therapeutic use , Middle Aged , Thyroid Function Tests