Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Front Vet Sci ; 5: 128, 2018.
Article in English | MEDLINE | ID: mdl-29971242

ABSTRACT

Retained fetal membranes (RFM) is a common post-partum problem in mares for which the treatment is highly variable. The aim of this study was (i) to investigate the different treatments used by equine practitioners for RFM and (ii) to determine if there is a difference between treatments used by reproductive specialists and general equine practitioners. Information regarding treatment of RFM was sought from veterinary practitioners via a survey and this was compared to recommendations in the current literature. The survey was sent out to equine veterinarians and mixed practitioners with a high equine case load. Most treatments of RFM were in line with current recommendations, while some obsolete practices are still routinely performed by a small number of practitioners. Treatment recommendations for RFM have changed over the last few decades, but there are no universally accepted guidelines. The vast variety of treatments reported by practitioners in the present survey reflect this lack of guidance. More extensive research is needed in this area to establish evidence-based, uniformly agreed upon protocols.

2.
J Virol Methods ; 188(1-2): 153-60, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23036750

ABSTRACT

Nucleic acid amplification techniques have become the mainstay for ultimate sensitivity for detecting low levels of virus, including human immunodeficiency virus (HIV). As a sophisticated technology with relative expensive reagents and instrumentation, adoption of nucleic acid testing (NAT) can be cost inhibited in settings in which access to extreme sensitivity could be clinically advantageous for detection of acute infection. A simple low cost digital immunoassay was developed for the p24 capsid protein of HIV based on trapping enzyme-labeled immunocomplexes in high-density arrays of femtoliter microwells and constraining the diffusion of the enzyme-substrate reaction. The digital immunoassay was evaluated for analytical sensitivity for HIV capsid protein p24, and compared with commercially available NAT methods and immunoassays for p24, including 4th-generation antibody/antigen combo assays, for early detection of HIV in infected individuals. The digital immunoassay was found to exhibit 2000-3000-fold greater analytical sensitivity than conventional immunoassays reactive for p24, and comparable sensitivity to NAT methods. Assaying serial samples from 10 HIV-infected individuals, the digital immunoassay detected acute HIV infection as early as NAT methods, and 7-10 days earlier than conventional immunoassays. Comparison of assay results between the digital immunoassay and a quantitative NAT method from HIV infected serum exhibited a linear correlation R(2)>0.99. The data indicate that by constraining diffusion of the signal generation step of a simple sandwich immunoassay and enabling the digital counting of immunocomplexes, dramatic improvements in sensitivity to virus can be obtained to match the sensitivity of NAT at a fraction of the cost.


Subject(s)
Clinical Laboratory Techniques/methods , HIV Core Protein p24/blood , HIV Infections/diagnosis , Humans , Immunoassay/methods , Sensitivity and Specificity
3.
Clin Chem ; 57(12): 1712-21, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21998342

ABSTRACT

BACKGROUND: Measurement of prostate-specific antigen (PSA) in prostate cancer patients following radical prostatectomy (RP) has been hindered by the limit of quantification of available assays. Because radical prostatectomy removes the tissue responsible for PSA production, postsurgical PSA is typically undetectable with current assay methods. Evidence suggests, however, that more sensitive determination of PSA status following RP could improve assessment of patient prognosis and response to treatment and better target secondary therapy for those who may benefit most. We developed an investigational digital immunoassay with a limit of quantification 2 logs lower than current ultrasensitive third-generation PSA assays. METHODS: We developed reagents for a bead-based ELISA for use with high-density arrays of femtoliter-volume wells. Anti-PSA capture beads with immunocomplexes and associated enzyme labels were singulated within the wells of the arrays and interrogated for the presence of enzymatic product. We characterized analytical performance, compared its accuracy with a commercially available test, and analyzed longitudinal serum samples from a pilot study of 33 RP patients. RESULTS: The assay exhibited a functional sensitivity (20% interassay CV) <0.05 pg/mL, total imprecision <10% from 1 to 50 pg/mL, and excellent agreement with the comparator method. All RP samples were well within the assay measurement capability. PSA concentrations following surgery were found to be predictive of prostate cancer recurrence risk over 5 years. CONCLUSIONS: The robust 2-log improvement in limit of quantification relative to current ultrasensitive assays and the validated analytical performance of the assay allow for accurate assessment of PSA status after RP.


Subject(s)
Enzyme-Linked Immunosorbent Assay/methods , Prostate-Specific Antigen/blood , Electronic Data Processing , Humans , Male , Microchemistry/methods , Middle Aged , Pilot Projects , Prostatectomy , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/surgery , Protein Array Analysis/methods , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
4.
J Immunol Methods ; 372(1-2): 177-86, 2011 Sep 30.
Article in English | MEDLINE | ID: mdl-21821036

ABSTRACT

The quantitative measurement of inflammatory cytokines in blood has been limited by insufficient sensitivity of conventional immunoassays. This limitation has prevented the widespread clinical monitoring of cytokine concentrations in chronic inflammatory diseases. We applied a sensitive, single molecule detection technology to measure TNF-α and IL-6 in the plasma of patients with Crohn's disease (CD), before and after treatment with anti-TNF-α therapy. Plasma from 17 patients with CD was collected prior to initiation of anti-TNF-α therapy, and the Crohn's disease activity index (CDAI) was determined for each patient. A sub-set of these patients returned for follow up 12 weeks after treatment started. Plasma from age- and gender-matched controls was also collected. Digital ELISAs were developed for TNF-α and IL-6, and the plasma concentrations of these cytokines were determined using digital ELISA. The limits of detection of the TNF-α and IL-6 digital ELISAs were 0.008 pg/mL and 0.006 pg/mL, respectively. Both cytokines were detected in all samples using digital ELISA and the concentrations of TNF-α and IL-6 in the plasma of patients with CD were (3.6±0.9) pg/mL and (10.9±11.2) pg/mL, respectively. TNF-α levels in patients and healthy controls were not significantly different, but the IL-6 levels in plasma were significantly elevated in patients compared to controls. After therapy, the mean reduction of the concentrations of free TNF-α and IL-6 were 46% and 58%, respectively. Digital ELISA provided the first quantitative measurements of TNF-α and IL-6 concentrations in the plasma of all patients in a population with CD. The changes in cytokine concentrations after therapy--which could be quantified because of the high sensitivity of digital ELISA--could be used for monitoring therapeutic efficacy.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , Crohn Disease/immunology , Enzyme-Linked Immunosorbent Assay/methods , Interleukin-6/blood , Tumor Necrosis Factor-alpha/blood , Adalimumab , Adolescent , Adult , Aged , Antibodies, Monoclonal/therapeutic use , Antibodies, Monoclonal, Humanized , Certolizumab Pegol , Crohn Disease/blood , Crohn Disease/drug therapy , Enzyme-Linked Immunosorbent Assay/standards , Follow-Up Studies , Humans , Immunoglobulin Fab Fragments/therapeutic use , Infliximab , Limit of Detection , Male , Middle Aged , Polyethylene Glycols/therapeutic use , Sensitivity and Specificity , Tumor Necrosis Factor-alpha/antagonists & inhibitors , Young Adult
5.
J Proteome Res ; 6(11): 4256-68, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17902640

ABSTRACT

The purpose of this discovery phase study was to identify candidate protein biomarkers for high-grade dysplastic cervical cells using mass spectrometry. Laser Capture Microdissection (LCM) was utilized to isolate high-grade dysplastic and normal cells from ThinPrep slides prepared from cervical cytological specimens. Following cell capture, samples were solubilized and proteins separated by gel electrophoresis in preparation for enzymatic digestion and liquid chromatography mass spectrometry analysis (LC-MS). Processed samples were subsequently analyzed using a linear ion trap coupled with a Fourier transform mass spectrometer (LTQ-FT MS). It was determined that both PreservCyt Solution and ThinPrep Pap Stain (Cytyc Corporation) were compatible with the sample processing and LC-MS analysis. In total, from 9 normal and 9 abnormal cervical cytological specimens, more than 1000 unique proteins were identified with high confidence, based on approximately 12,000 captured cells per specimen. Quantitative protein differences between HSIL (High-Grade Squamous Intraepithelial Lesion) and NILM (Negative for Intraepithelial Lesions or Malignancy) samples were determined by comparing the intensities of the representative (label-free) peptide ions. More than 200 proteins were found to exhibit a 3-fold difference in protein level. Interestingly, significant up-regulation of nuclear and mitochondrial proteins in HSIL specimens was noted. In several cases, the increased protein abundance observed in high-grade cells, as determined by quantitative LC-MS, was validated by immunocytochemical methods using ThinPrep cervical specimens. With the study of additional clinical specimens, the differential abundance of proteins in high-grade dysplastic cells versus morphologically normal cervical cells may lead to validated novel biomarkers for cervical disease.


Subject(s)
Carcinoma/metabolism , Carcinoma/pathology , Gene Expression Regulation, Neoplastic , Mass Spectrometry/methods , Proteins/chemistry , Proteomics/instrumentation , Proteomics/methods , Uterine Cervical Neoplasms/metabolism , Uterine Cervical Neoplasms/pathology , Vaginal Smears/instrumentation , Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Cytodiagnosis/methods , Cytological Techniques , Female , Humans , Lasers , Mass Screening , Mass Spectrometry/instrumentation , Microdissection , Papillomaviridae/metabolism , Vaginal Smears/methods
6.
Cancer ; 111(2): 83-92, 2007 Apr 25.
Article in English | MEDLINE | ID: mdl-17334990

ABSTRACT

BACKGROUND: The aim of this study was to examine p16(INK4a) protein expression in ThinPrep (Cytyc Corporation, Marlborough, Mass) cervical specimens by using the CINtec p16(INK4a) Cytology Kit (Dako, Glostrup, Denmark). The ability of this assay to accurately identify underlying high-grade lesions was assessed by using follow-up biopsies and comparing these results with Hybrid Capture 2 (Digene, Gaithersburg, Md) high-risk HPV (hc(2)) results. METHODS: Three hundred ninety-eight residual ThinPrep samples were collected, and histological follow-up data were retrieved for abnormal cytology specimens. After preparation of a Papanicolaou-stained slide, a second slide was processed in preparation for p16(INK4a) immunostaining. High-risk human papillomavirus testing (hc(2)) was also performed. RESULTS: Of the 163 cytologically abnormal samples, 6-month biopsy follow-up data were available for 45% of the specimens. At initial blinded evaluation, 21 of the 26 cases with cervical intraepithelial neoplasia (CIN) II/III follow-up were positive for p16(INK4a), yielding an overall diagnostic sensitivity of 81%; 29 of the 47 cases diagnosed as CIN I or less were p16(INK4a) negative, yielding a diagnostic specificity of 62%. In comparison, the hc(2) test results indicated a diagnostic sensitivity of 100% with a diagnostic specificity of 15%. After review of selected cases with CIN II/III follow-up, 25 of 26 slides were deemed to be positive for p16(INK4a), increasing the diagnostic sensitivity to 96%. CONCLUSIONS: The CINtec p16(INK4a) Cytology Kit, in combination with ThinPrep cervical samples, allowed clear evaluation of p16(INK4a) protein overexpression. Diagnostic specificity of the CINtec p16(INK4a) assay was significantly improved relative to hc(2). To increase p16(INK4a) immunostaining in abnormal cells, a modified kit version with improved staining performance has been developed and is currently being evaluated.


Subject(s)
Biomarkers, Tumor/analysis , Cyclin-Dependent Kinase Inhibitor p16/biosynthesis , Cytological Techniques , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Neoplasms/diagnosis , Biopsy , Female , Humans , Immunohistochemistry , Papanicolaou Test , Sensitivity and Specificity , Uterine Cervical Neoplasms/metabolism , Vaginal Smears , Uterine Cervical Dysplasia/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...