Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Osteoporos Int ; 11(6): 537-43, 2000.
Article in English | MEDLINE | ID: mdl-10982171

ABSTRACT

On radiation safety grounds there is concern about the morbidity attributable to routine radiographs of the spine for the identification of new fractures in large-scale trials of fracture prevention. However, the role of the potentially safer low-radiation-dose technique of vertebral morphometry performed by third generation dual-energy X-ray absorptiometry equipment requires evaluation for use in clinical trials. We have therefore investigated the short-term inter-scan imprecision as well as the imprecision attributable to different-day analyses by the same operator and differences in analyses by different operators. The volunteer subjects were participants in a pilot study for a randomized controlled trial of hormone replacement therapy (Women's International Study of long Duration Oestrogen after Menopause, WISDOM). Each subject had two morphometric X-ray analysis scans separated by 2-4 weeks. Exclusions were women with densitometrically defined osteoporosis, as defined by the WHO criterion, and women with a body mass index exceeding 30.9 kg/m2. On average, the women were 58.7 years of age and had bone mineral density values in the lumbar spine which were about 0.7 SD units higher than a reference US female age-matched population. Scans were assessed from vertebrae T7 through L4. In the study there were no clinically significant differences in performance between the Hologic QDR 4500A and the Lunar Expert XL equipment. Between-scan imprecision was significantly worse than imprecision attributable to reanalysis of the same scan by a different operator or the same operator after an interval. Vertebral level had an effect on measurement uncertainty, especially at the level of the diaphragm and at T7. Coefficients of variation, expressed as percentages of mean values, were better for absolute height measurements than for height ratios, ranging from 1.75% to 3.40% for the three heights measured on three separate machines and from 2.34% to 4.11% for the two height ratios. These results compared favorably with the equivalent figures from a parallel study of morphometry precision undertaken using standard lateral radiographs of the thoracic and lumbar spine (3.1-3.6% and 3.8-3.9%, respectively). We conclude that in trials of prevention therapy in women (or men) selected for not having osteoporosis, low-dose vertebral morphometry using the Hologic 4500A, the Lunar Expert XL or similar equipment is preferable on safety grounds to the classical technique based on standard radiographs, although conventional radiology may still be required in those with prevalent or incident deformities to exclude causes other than osteoporosis. The place of this low-dose technique in trials performed on patients with osteoporosis requires further study.


Subject(s)
Absorptiometry, Photon/standards , Spine/diagnostic imaging , Absorptiometry, Photon/methods , Aged , Bone Density , Estrogen Replacement Therapy , Feasibility Studies , Female , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Middle Aged , Osteoporosis, Postmenopausal/prevention & control , Pilot Projects , Randomized Controlled Trials as Topic , Reproducibility of Results , Spine/physiopathology , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/physiopathology , Treatment Outcome
2.
Am J Clin Nutr ; 67(4): 685-92, 1998 Apr.
Article in English | MEDLINE | ID: mdl-9537615

ABSTRACT

Factors influencing the change in bone mineral after 3 mo of lactation were investigated in 47 breast-feeding mothers, 11 formula-feeding mothers, and 22 nonpregnant, nonlactating control subjects. At 6-8 wk postpartum, the breast-feeding group had a mean (+/-SD) calcium intake of 34.8+/-13.2 mmol/d and breast-milk volume, calcium concentration, and calcium output of 0.865+/-0.230 L/d, 7.41+/-1.25 mmol/L, and 6.41+/-2.00 mmol/d, respectively. There was no relation between calcium intake and any breast-milk variable. Dual-energy X-ray absorptiometry of the whole body, spine, hip, and forearm was performed at 0.5 and 3 mo. There were significant decreases in bone mineral content at the spine (3.96%; 95% CI: 4.86%, 3.06%), femoral neck (2.39%; 95% CI: 3.61%, 1.17%), total hip (1.51%; 95% CI: 2.45%, 0.60%), and whole body (0.86%; 95% CI: 1.29%, 0.43%) in breast-feeding mothers but not in formula-feeding mothers or nonpregnant, nonlactating women. These changes were not related to calcium intake, breast-milk calcium concentration, vitamin D-receptor genotype, postpartum weight change, or use of the progesterone-only contraceptive pill. After adjustment for bone area, breast-milk volume and height were identified as significant predictors at the spine, such that greater decreases were associated with taller mothers (P = 0.007) and those with greater breast-milk volume (P = 0.001). This finding suggests that the marked bone mineral changes observed in breast-feeding mothers represented a physiologic response to lactation that was independent of dietary calcium supply.


Subject(s)
Bone Density , Bone and Bones/metabolism , Calcium, Dietary/administration & dosage , Lactation/physiology , Receptors, Calcitriol/genetics , Absorptiometry, Photon , Adult , Calcium/metabolism , Female , Genotype , Humans , Milk, Human/metabolism , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...