Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Clin Virol ; 102: 42-49, 2018 05.
Article in English | MEDLINE | ID: mdl-29494950

ABSTRACT

BACKGROUND: Emergency Departments (ED) are challenged during influenza season by patients who present acutely during sporadic ED visits. ED management is largely empiric, often occurring without reliable diagnostics needed for targeted therapies, safe outpatient discharge, or hospital admissions. OBJECTIVE: To evaluate the impact of the influenza diagnosis on physician decision making during ED visits using the Cobas Liat® influenza A + B assay. STUDY DESIGN: Prospective study assessing the impact of rapid (<30 min), reverse-transcriptase polymerase chain reaction (RT-PCR) influenza testing on physician decision making in the ED. Physician responses established pre-and post-diagnosis management courses which required confirmation via secondary documentation in the medical record. Changes in physician decision making were analyzed across four clinical touchpoints: (i) admission/discharge status, (ii) medical procedures, (iii) antiviral and antibiotic prescribing, and (iv) laboratory studies. RESULTS: An influenza diagnosis changed patient management courses, relative to empiric, pre-diagnosis plans, in in 61% of the cases resulting in cost savings of $49,420-to-$42,270 over 143 patients and 104 days during influenza season resulting in a cost savings of $200.40/ED visit. Evaluation over 2000 ED patient visits projects cost savings > $578,000 due to deferred admissions, and reduction in antiviral prescribing. Sensitivity of ED-based influenza testing using the Cobas Liat® assay was equivalent to centralized lab testing at 98.8% sensitivity and 98.5% specificity respectively. CONCLUSION: Providing rapid, RT-PCR influenza testing to ED settings is actionable and used to guide patient care decisions. Understanding the cascade of events linked to the influenza diagnosis in the ED provides overall cost savings which offset the cost of providing ED-based testing.


Subject(s)
Emergency Service, Hospital , Influenza A virus/isolation & purification , Influenza B virus/isolation & purification , Influenza, Human/diagnosis , Reverse Transcriptase Polymerase Chain Reaction , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Clinical Decision-Making , Humans , Infant , Influenza A virus/genetics , Influenza B virus/genetics , Middle Aged , Point-of-Care Systems/economics , Prospective Studies , Sensitivity and Specificity , Young Adult
2.
Infect Immun ; 83(6): 2350-7, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25824834

ABSTRACT

Resistance to the innate defenses of the intestine is crucial for the survival and carriage of Staphylococcus aureus, a common colonizer of the human gut. Bile salts produced by the liver and secreted into the intestines are one such group of molecules with potent antimicrobial activity. The mechanisms by which S. aureus is able to resist such defenses in order to colonize and survive in the human gut are unknown. Here we show that mnhF confers resistance to bile salts, which can be abrogated by efflux pump inhibitors. MnhF mediates the efflux of radiolabeled cholic acid both in S. aureus and when heterologously expressed in Escherichia coli, rendering them resistant. Deletion of mnhF attenuated the survival of S. aureus in an anaerobic three-stage continuous-culture model of the human colon (gut model), which represents different anatomical areas of the large intestine.


Subject(s)
Bacterial Proteins/metabolism , Cholates/metabolism , Colon/physiology , Gene Expression Regulation, Bacterial/physiology , Staphylococcus aureus/metabolism , Bacterial Proteins/genetics , Cloning, Molecular , Colon/microbiology , Humans , Models, Biological , Staphylococcus aureus/genetics
3.
Clin Infect Dis ; 56(6): 790-7, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23223586

ABSTRACT

BACKGROUND: Antimicrobial removal devices in blood culture media are designed to remove antibiotics from the blood culture solution, thereby facilitating bacterial growth. How well these devices function clinically has not been established. METHODS: All blood drawn for culture from adult inpatients and emergency department visitors in a level I trauma center was placed in paired BACTEC Plus and BacT/Alert FAN culture media and studied simultaneously, consecutively, and prospectively between 1 February and 30 September 2011. All cultures were processed per standard laboratory protocols. RESULTS: Of 9395 total cultures collected, 1219 (13%) were positive, 831 were included, and 524 (33%) contained pathogens. BACTEC had a 4.5-hour faster detection time (P < .0001), and isolated exclusively 182 of 524 (35%; P < .001) pathogens, 136 of 345 (39%) of the gram-positive cocci (P < .001), 48 of 175 (27%; P = .02) of the gram-negative rods, 101 of 195 (52%) of Staphylococcus aureus (P < .001), and 59 of 120 (49%; P = .004) septic events. If active antibiotics had been dosed 0-4 or 4-48 hours prior to culture collection, the odds of that culture growing in BACTEC were 4.8- and 5.2-fold greater, respectively, than of growing in BacT/Alert (P < .0001). Both were equivalent in the recovery of yeast and when no antimicrobials were dosed. CONCLUSIONS: BACTEC media has faster time to detection and increased bacterial recovery over the BacT/Alert media in the following categories: overall growth, pathogens, septic events, gram-positive cocci, gram-negative rods, Staphylococcus aureus, and cultures where antimicrobials were dosed up to 48 hours before culture collection.


Subject(s)
Anti-Bacterial Agents/antagonists & inhibitors , Anti-Bacterial Agents/therapeutic use , Bacteremia/diagnosis , Bacteria/isolation & purification , Bacteriological Techniques/methods , Culture Media/chemistry , Adult , Humans , Sensitivity and Specificity , Time Factors
4.
Clin Infect Dis ; 49(6): 908-13, 2009 Sep 15.
Article in English | MEDLINE | ID: mdl-19686072

ABSTRACT

BACKGROUND: Approximately 4 million US travelers to developing countries are ill enough to seek health care, with 1500 malaria cases reported in the United States annually. The diagnosis of malaria is frequently delayed because of the time required to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful. The objective of this study was to determine the diagnostic performance of a RDT approved by the US Food and Drug Administration compared with traditional thick and thin blood smears for malaria diagnosis. METHODS: This prospective study tested 852 consecutive blood samples that underwent thick and thin smears and blinded malaria RDTs at 3 hospital laboratories during 2003-2006. Polymerase chain reaction verified positive test results and discordant results. RESULTS: Malaria was noted in 95 (11%) of the 852 samples. The RDT had superior performance than the standard Giemsa thick blood smear (p = .003). The RDT's sensitivity for all malaria was 97% (92 of 95 samples), compared with 85% (81 of 95) for the blood smear, and the RDT had a superior NPV of 99.6%, compared with 98.2% for the blood smear (p = .001). The P. falciparum performance was excellent, with 100% rapid test sensitivity, compared with only 88% (65 of 74) by blood smear (p = .003). CONCLUSIONS: This operational study demonstrates that the US Food and Drug Administration-approved RDT for malaria is superior to a single set of blood smears performed under routine US clinical laboratory conditions. The most valuable clinical role of the RDT is in the rapid diagnosis or the exclusion of P. falciparum malaria, which is particularly useful in outpatient settings when evaluating febrile travelers.


Subject(s)
Hematologic Tests , Malaria/blood , Malaria/diagnosis , Reagent Kits, Diagnostic , Adolescent , Adult , Aged , Animals , Antibodies, Monoclonal , Antigens, Protozoan/blood , Child , Child, Preschool , Female , Fructose-Bisphosphate Aldolase/blood , Fructose-Bisphosphate Aldolase/metabolism , Humans , Infant , Malaria, Falciparum/blood , Malaria, Falciparum/diagnosis , Male , Middle Aged , Parasitemia/diagnosis , Plasmodium/enzymology , Plasmodium/isolation & purification , Polymerase Chain Reaction , Predictive Value of Tests , Prospective Studies , Protozoan Proteins/blood , Sensitivity and Specificity , Travel , United States , United States Food and Drug Administration , Young Adult
5.
Pediatr Infect Dis J ; 25(10): 948-50, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17006296

ABSTRACT

Before an empiric malaria treatment program, >60% of Liberian refugees had malaria on arrival to Minnesota. We compared microscopy with rapid antigen testing for detecting asymptomatic parasitemia. Nine of 103 (8.7%) had malaria by polymerase chain reaction (blood smear and rapid testing had a sensitivity of 22%). The empiric treatment program has decreased the rate of imported asymptomatic malaria. Blood film and rapid antigen testing are poor screening tests.


Subject(s)
Malaria/diagnosis , Mass Screening , Refugees , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Immunoenzyme Techniques , Infant , Malaria/epidemiology , Malaria, Falciparum/diagnosis , Malaria, Falciparum/epidemiology , Male , Microscopy , Middle Aged , Sensitivity and Specificity , United States
6.
Am J Clin Pathol ; 123(6): 809-16, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15899770

ABSTRACT

To establish the effect of a quality control failure on the performance of the LCx-GC nucleic-acid amplification assay for Neisseria gonorrhoeae (Abbott Laboratories, Abbott Park, IL) in the field, we conducted a retrospective analysis comparing the clinical and analytic performance of the recalled lots with those not implicated in the recall. Our analysis revealed no statistically significant differences between recalled lots (n = 8,686 tests) and nonrecalled lots (n = 8,699 tests) with respect to multiple parameters of assay performance, including frequency distribution of patient results (P = .575), prevalence of indeterminate results (P = .245), mean positive control signals (P = .26), and within-run calibrator precision (P = .68). The LCx-GC system's lack of an electronic data storage and retrieval capability prevented assessment of the impact of the quality control failure on the clinical performance of recalled lots, such as the one described herein, from being conducted in real time.


Subject(s)
Gonorrhea/diagnosis , Neisseria gonorrhoeae/isolation & purification , Nucleic Acid Amplification Techniques , Quality Assurance, Health Care , Reagent Kits, Diagnostic , Animals , Female , Humans , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...