1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 2271-2274, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060350

ABSTRACT

Motion recognition is an important application of electromyography (EMG) analysis. While discrete motions such as hand open, hand close and wrist pronation have been extensively investigated, studies on combined motions involving two or more degrees of freedom (DOFs) are relatively few and the classification accuracy of the combined motions reported in previous studies is barely satisfactory. To improve the accuracy of the combined motion recognition, common spatial pattern (CSP) was employed in this study to extract spatial features. 18 forearm motion classes, consisted of 8 discrete motions and 10 combined motions, were classified by the proposed method. Our results showed that the accuracy rate of CSP features was 96.3%, which outperformed the commonly used time-domain (TD) features by 2.4% and TD combined with auto-regression coefficients (TDAR) by 0.6%. Moreover, CSP features cost noticeable much less time than TDAR and quite less time than TD in testing. These results suggest that CSP features could be a better feature set for multi-DOF myoelectric control than conventional features.


Subject(s)
Motion , Algorithms , Electromyography , Hand , Humans , Pattern Recognition, Automated , Wrist
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 4439-4442, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060882

ABSTRACT

Continuous electrocardiogram (ECG) monitoring is significant for prevention of heart disease and is becoming an important part of personal and family health care. In most of the existing wearable solutions, conventional metal sensors and corresponding chips are simply integrated into clothes and usually could only collect few leads of ECG signals that could not provide enough information for diagnosis of cardiac diseases such as arrhythmia and myocardial ischemia. In this study, a wearable 12-lead ECG acquisition system with fabric electrodes was developed and could simultaneously process 12 leads of ECG signals. By integrating the fabric electrodes into a T-shirt, the wearable system would provide a comfortable and convenient user interface for ECG recording. For comparison, the proposed fabric electrode and the gelled traditional metal electrodes were used to collect ECG signals on a subject, respectively. The approximate entropy (ApEn) of ECG signals from both types of electrodes were calculated. The experimental results show that the fabric electrodes could achieve similar performance as the gelled metal electrodes. This preliminary work has demonstrated that the developed ECG system with fabric electrodes could be utilized for wearable health management and telemedicine applications.


Subject(s)
Electrocardiography , Electrodes , Equipment Design , Textiles , Wearable Electronic Devices