Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 12(1): 15908, 2022 09 23.
Article in English | MEDLINE | ID: mdl-36151260

ABSTRACT

The current body of sprinting biomechanics literature together with the front-side mechanics coaching framework provide various technique recommendations for improving performance. However, few studies have attempted to systematically explore technique modifications from a performance enhancement perspective. The aims of this investigation were therefore to explore how hypothetical technique modifications affect accelerative sprinting performance and assess whether the hypothetical modifications support the front-side mechanics coaching framework. A three-dimensional musculoskeletal model scaled to an international male sprinter was used in combination with direct collocation optimal control to perform (data-tracking and predictive) simulations of the preliminary steps of accelerative sprinting. The predictive simulations differed in the net joint moments that were left 'free' to change. It was found that the 'knee-free' and 'knee-hip-free' simulations resulted in the greatest performance improvements (13.8% and 21.9%, respectively), due to a greater knee flexor moment around touchdown (e.g., 141.2 vs. 70.5 Nm) and a delayed and greater knee extensor moment during stance (e.g., 188.5 vs. 137.5 Nm). Lastly, the predictive simulations which led to the greatest improvements were also found to not exhibit clear and noticeable front-side mechanics technique, thus the underpinning principles of the coaching framework may not be the only key aspect governing accelerative sprinting.


Subject(s)
Running , Acceleration , Biomechanical Phenomena , Humans , Knee , Knee Joint , Male
2.
PeerJ ; 9: e10975, 2021.
Article in English | MEDLINE | ID: mdl-33732550

ABSTRACT

Biomechanical simulation and modelling approaches have the possibility to make a meaningful impact within applied sports settings, such as sprinting. However, for this to be realised, such approaches must first undergo a thorough quantitative evaluation against experimental data. We developed a musculoskeletal modelling and simulation framework for sprinting, with the objective to evaluate its ability to reproduce experimental kinematics and kinetics data for different sprinting phases. This was achieved by performing a series of data-tracking calibration (individual and simultaneous) and validation simulations, that also featured the generation of dynamically consistent simulated outputs and the determination of foot-ground contact model parameters. The simulated values from the calibration simulations were found to be in close agreement with the corresponding experimental data, particularly for the kinematics (average root mean squared differences (RMSDs) less than 1.0° and 0.2 cm for the rotational and translational kinematics, respectively) and ground reaction force (highest average percentage RMSD of 8.1%). Minimal differences in tracking performance were observed when concurrently determining the foot-ground contact model parameters from each of the individual or simultaneous calibration simulations. The validation simulation yielded results that were comparable (RMSDs less than 1.0° and 0.3 cm for the rotational and translational kinematics, respectively) to those obtained from the calibration simulations. This study demonstrated the suitability of the proposed framework for performing future predictive simulations of sprinting, and gives confidence in its use to assess the cause-effect relationships of technique modification in relation to performance. Furthermore, this is the first study to provide dynamically consistent three-dimensional muscle-driven simulations of sprinting across different phases.

3.
Sensors (Basel) ; 20(20)2020 Oct 10.
Article in English | MEDLINE | ID: mdl-33050436

ABSTRACT

Wearable sensors and motion capture technology are accepted instruments to measure spatiotemporal variables during punching performance and to study the externally observable effects of fatigue. This study aimed to develop a computational framework enabling three-dimensional inverse dynamics analysis through the tracking of punching kinematics obtained from inertial measurement units and uniplanar videography. The framework was applied to six elite male boxers performing a boxing-specific punch fatigue protocol. OpenPose was used to label left side upper-limb landmarks from which sagittal plane kinematics were computed. Custom-made inertial measurement units were embedded into the boxing gloves, and three-dimensional punch accelerations were analyzed using statistical parametric mapping to evaluate the effects of both fatigue and laterality. Tracking simulations of a sub-set of left-handed punches were formulated as optimal control problems and converted to nonlinear programming problems for solution with a trapezoid collocation method. The laterality analysis revealed the dominant side fatigued more than the non-dominant, while tracking simulations revealed shoulder abduction and elevation moments increased across the fatigue protocol. In future, such advanced simulation and analysis could be performed in ecologically valid contexts, whereby multiple inertial measurement units and video cameras might be used to model a more complete set of dynamics.


Subject(s)
Accelerometry , Boxing , Fatigue/diagnosis , Adolescent , Athletes , Biomechanical Phenomena , Humans , Male , Sports Equipment , Video Recording , Wearable Electronic Devices , Young Adult
4.
Eur J Appl Physiol ; 120(8): 1745-1759, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32488584

ABSTRACT

PURPOSE: Prior studies exploring the reliability of peak fat oxidation (PFO) and the intensity that elicits PFO (FATMAX) are often limited by small samples. This study characterised the reliability of PFO and FATMAX in a large cohort of healthy men and women. METHODS: Ninety-nine adults [49 women; age: 35 (11) years; [Formula: see text]O2peak: 42.2 (10.3) mL·kg BM-1·min-1; mean (SD)] completed two identical exercise tests (7-28 days apart) to determine PFO (g·min-1) and FATMAX (%[Formula: see text]O2peak) by indirect calorimetry. Systematic bias and the absolute and relative reliability of PFO and FATMAX were explored in the whole sample and sub-categories of: cardiorespiratory fitness, biological sex, objectively measured physical activity levels, fat mass index (derived by dual-energy X-ray absorptiometry) and menstrual cycle status. RESULTS: No systematic bias in PFO or FATMAX was found between exercise tests in the entire sample (- 0.01 g·min-1 and 0%[Formula: see text]O2peak, respectively; p > 0.05). Absolute reliability was poor [within-subject coefficient of variation: 21% and 26%; typical errors: ± 0.06 g·min-1 and × / ÷ 1.26%[Formula: see text]O2peak; 95% limits of agreement: ± 0.17 g·min-1 and × / ÷ 1.90%[Formula: see text]O2peak, respectively), despite high (r = 0.75) and moderate (r = 0.45) relative reliability for PFO and FATMAX, respectively. These findings were consistent across all sub-groups. CONCLUSION: Repeated assessments are required to more accurately determine PFO and FATMAX.


Subject(s)
Lipid Metabolism , Oxygen Consumption , Oxygen/metabolism , Adipose Tissue/metabolism , Adiposity , Adolescent , Adult , Aged , Analysis of Variance , Bias , Calorimetry/methods , Calorimetry/standards , Cardiorespiratory Fitness , Data Interpretation, Statistical , Exercise Test , Female , Humans , Male , Middle Aged , Oxidation-Reduction , Reproducibility of Results
5.
Scand J Med Sci Sports ; 30(2): 227-237, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31598998

ABSTRACT

Mechanical peak power output (PPO) is a determinant of performance in sprint cycling. The purpose of this study was to examine the relationship between PPO and putative physiological determinants of PPO in elite cyclists, and to compare sprint performance between elite sprint and endurance cyclists. Thirty-five elite cyclists (18 endurance; 17 sprint) performed duplicate sprint cycling laboratory tests to establish PPO and its mechanical components. Quadriceps femoris (QVOL ) and hamstring muscle volume (HAMVOL ) were assessed with MRI, vastus lateralis pennation angle (PθVL ) and fascicle length (FLVL ) were determined with ultrasound imaging, and neuromuscular activation of three muscles was assessed using EMG at PPO during sprint cycling. For the whole cohort, there was a wide variability in PPO (range 775-2025 W) with very large, positive, bivariate relationships between PPO and QVOL (r = .87), HAMVOL (r = .71), and PθVL (r = .81). Step-wise multiple regression analysis revealed that 87% of the variability in PPO between cyclists was explained by two variables QVOL (76%) and PθVL (11%). The sprint cyclists had greater PPO (+61%; P < .001 vs endurance), larger QVOL (P < .001), and BFVOL (P < .001) as well as more pennate vastus lateralis muscles (P < .001). These findings emphasize the importance of quadriceps muscle morphology for sprint cycling events.


Subject(s)
Bicycling/physiology , Hamstring Muscles/physiology , Muscle Strength , Quadriceps Muscle/physiology , Adult , Athletes , Humans , Male , Young Adult
6.
J Sports Sci ; 37(1): 36-41, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29851357

ABSTRACT

Gross thigh volume is a key anthropometric variable to predict sport performance and health. Currently, it is either estimated by using the frustum method, which is prone to high inter-and intra-observer error, or using medical imaging, which is expensive and time consuming. Depth camera 3D-imaging systems offer a cheap alternative to measure thigh volume but no between-session reliability or comparison to medical imaging has been made. This experiment established between-session reliability and examined agreement with magnetic resonance imaging (MRI). Forty-eight male cyclists had their thigh volume measured by the depth camera system on two occasions to establish between-session reliability. A subset of 32 participants also had lower body MRIs, through which agreement between the depth camera system and MRI was established. The results showed low between-session variability (CV = 1.7%; Absolute Typical Error = 112 cm3) when measuring thigh volume using the depth camera system. The depth camera systematically measured gross thigh volume 32.6cm3 lower than MRI. These results suggest that depth camera 3D-imaging systems are reliable tools for measuring thigh volume and show good agreement with MRI scanners, providing a cheap and time-saving alternative to medical imaging analysis.


Subject(s)
Anthropometry/methods , Imaging, Three-Dimensional/methods , Thigh/diagnostic imaging , Adolescent , Adult , Humans , Magnetic Resonance Imaging , Male , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...