Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 165
Filter
2.
Open Heart ; 11(1)2024 May 20.
Article in English | MEDLINE | ID: mdl-38769066

ABSTRACT

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
3.
JTCVS Open ; 18: 12-30, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38690415

ABSTRACT

Objective: Anterior mitral anular calcification, particularly in radiation heart disease, and previous valve replacement with destroyed intervalvular fibrosa are challenging for prosthesis sizing and placement. The Commando procedure with intervalvular fibrosa reconstruction permits double-valve replacement in these challenging conditions. We referenced outcomes after Commando procedures to standard double-valve replacements. Methods: From January 2011 to January 2022, 129 Commando procedures and 1191 aortic and mitral double-valve replacements were performed at the Cleveland Clinic, excluding endocarditis. Reasons for the Commando were severe calcification after radiation (n = 67), without radiation (n = 43), and others (n = 19). Commando procedures were referenced to a subset of double-valve replacements using balancing-score methods (109 pairs). Results: Between balanced groups, Commando versus double-valve replacement had higher total calcium scores (median 6140 vs 2680 HU, P = .03). Hospital outcomes were similar, including operative mortality (12/11% vs 8/7.3%, P = .35) and reoperation for bleeding (9/8.3% vs 5/4.6%, P = .28). Survival and freedom from reoperation at 5 years were 54% versus 67% (P = .33) and 87% versus 100% (P = .04), respectively. Higher calcium score was associated with lower survival after double-valve replacement but not after the Commando. The Commando procedure had lower aortic valve mean gradients at 4 years (9.4 vs 11 mm Hg, P = .04). After Commando procedures for calcification, 5-year survival was 60% and 59% with and without radiation, respectively (P = .47). Conclusions: The Commando procedure with reconstruction of the intervalvular fibrosa destroyed by mitral anular calcification, radiation, or previous surgery demonstrates acceptable outcomes similar to standard double-valve replacement. More experience and long-term outcomes are required to refine patient selection for and application of the Commando approach.

6.
Article in English | MEDLINE | ID: mdl-38641438

ABSTRACT

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

7.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38569793

ABSTRACT

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Subject(s)
Cardiac Surgical Procedures , Heart Diseases , Humans , Predictive Value of Tests , Cardiac Surgical Procedures/methods , Computer Simulation , Heart Diseases/diagnostic imaging , Heart Diseases/therapy , Software , Printing, Three-Dimensional
8.
Kidney Med ; 6(3): 100774, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38435071

ABSTRACT

Rationale & Objective: We sought to compare outcomes of patients receiving dialysis after cardiothoracic surgery on the basis of dialysis modality (intermittent hemodialysis [HD] vs peritoneal dialysis [PD]). Study Design: This was a retrospective analysis. Setting & Participants: In total, 590 patients with kidney failure receiving intermittent HD or PD undergoing coronary artery bypass graft and/or valvular cardiac surgery at Cleveland Clinic were included. Exposure: The patients received PD versus HD (intermittent or continuous). Outcomes: Our primary outcomes were in-hospital and 30-day mortality. Secondary outcomes were length of stay, days in the intensive care unit, the number of intraoperative blood transfusions, postsurgical pericardial effusion, and sternal wound infection, and a composite of the following 4 in-hospital events: death, cardiac arrest, effusion, and sternal wound infection. Analytical Approach: We used χ2, Fisher exact, Wilcoxon rank sum, and t tests, Kaplan-Meier survival, and plots for analysis. Results: Among the 590 patients undergoing cardiac surgery, 62 (11%) were receiving PD, and 528 (89%) were receiving intermittent HD. Notably, 30-day Kaplan-Meier survival was 95.7% (95% CI: 93.9-97.5) for HD and 98.2% (95% CI: 94.7-100) for PD (P = 0.30). In total, 75 patients receiving HD (14.2%) and 1 patient receiving PD (1.6%) had a composite of 4 in-hospital events (death, cardiac arrest, effusion, and sternal wound infection) (P = 0.005). Out of 62 patients receiving PD, 16 (26%) were converted to HD. Limitations: Retrospective analyses are prone to residual confounding. We lacked details about nutritional data. Intensive care unit length of stay was used as a surrogate for volume status control. Patients have been followed in a single health care system. The HD cohort outnumbered the PD cohort significantly. Conclusions: When compared with PD, HD does not appear to improve outcomes of patients with kidney failure undergoing cardiothoracic surgery. Patients receiving PD had a lower incidence of a composite outcome of 4 in-hospital events (death, cardiac arrest, pericardial effusion, and sternal wound infections).


Patients receiving peritoneal dialysis (PD) are frequently switched to hemodialysis (HD) around the time of an open-heart surgery. More times than not, this is driven by the preference of nonkidney doctors, because HD is perceived to control toxins and fluids better. PD is, however, more advantageous and can achieve similar results while being gentler. In an effort to keep patients on their home PD, we analyzed how they fared when compared with their HD counterparts. Patients maintained on PD did just as well if not better around and after their open-heart surgery. Given the expected increase in patients treated with PD, efforts should be made to maintain them on their home modality even around major surgeries.

9.
JACC Case Rep ; 29(6): 102238, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38549857

ABSTRACT

Cardiac tumors of the left ventricle are rare, and cardiac magnetic resonance is the preferred imaging tool for evaluation given superior tissue characterization. We present a case of a patient with arrhythmia and left ventricular mass that was ultimately diagnosed with cardiac sarcoidosis, reminding us that tissue is the issue.

10.
Am J Cardiol ; 217: 86-93, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38432333

ABSTRACT

Low muscle mass (LMM) is associated with worse outcomes in various clinical situations. Traditional frailty markers have been used for preoperative risk stratification in patients who underwent transcatheter aortic valve replacement (TAVR). However, preoperative imaging provides an opportunity to directly quantify skeletal muscle mass to identify patients at higher risk of procedural complications. We reviewed all TAVR recipients from January to December 2018 and included subjects with preprocedural chest computed tomography. Multi-slice automated measurements of skeletal muscle mass were made from the ninth to twelfth thoracic vertebrae and normalized by height squared to obtain skeletal muscle index (cm2/m2). LMM was defined as the lowest gender-stratified skeletal muscle index tertile. Strength testing was collected during pre-TAVR evaluation. Primary outcome was a composite of perioperative complications, 1-year rehospitalization, or 1-year mortality. In our cohort, 238 patients met inclusion criteria, and 80 (33.6%) were identified to have LMM. Patients with LMM were older with lower body mass index, decreased grip strength, lower hemoglobin A1c, and higher N-terminal pro-brain natriuretic peptide. They had greater rates of the composite outcome and 2-year all-cause mortality, which remained significant on multivariable adjustment (hazard ratio 1.71, 95% confidence interval 1.05 to 2.78, p = 0.030 and hazard ratio 2.31, 95% confidence interval 1.02 to 5.24, p = 0.045, respectively) compared with patients without LMM; there was no significant difference in 5-year all-cause mortality. In conclusion, LMM was associated with an increase in the primary composite outcome and 2-year all-cause mortality in TAVR recipients. Using automatic muscle processing software on pre-TAVR computed tomography scans may serve as an additional preoperative risk stratification tool.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve Stenosis/complications , Tomography, X-Ray Computed/methods , Muscle, Skeletal/diagnostic imaging , Aortic Valve/surgery , Risk Factors
11.
Struct Heart ; 8(1): 100217, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38283567

ABSTRACT

Background: The Ozaki procedure using autologous pericardium is an interesting but complex alternative for aortic valve replacement. We present a standardized approach to minimize the learning curve and confirm reproducibility. Methods: After careful preparation, from May 2015 to February 2021, an Ozaki procedure was performed on 46 patients age 51 ± 14 years. Seven had unicuspid (15%), 29 bicuspid (63%), and 10 tricuspid (22%) aortic valves, and 2 patients had endocarditis. Endpoints were operative learning curves, perioperative outcomes, intermediate-term valve hemodynamics, reintervention, health-related quality of life (MacNew Heart Disease Health-Related Quality of Life questionnaire), and mortality. Results: Cardiopulmonary bypass and aortic clamp times decreased from 145 to 125 â€‹minutes and 120 to 100 â€‹minutes, respectively, over the first 20 cases, reflecting the learning curve. There was no major perioperative morbidity or mortality. Median postoperative stay was 6.9 days. Aortic regurgitation was mild or less in all but 2 patients who developed moderate aortic regurgitation. Mean aortic valve gradient was 7.9 mmHg postoperatively, 9.2 mmHg by 6 months, and constant thereafter. Left ventricular ejection fraction was 58% preoperatively, 60% at 6 months, and remained stable thereafter. One patient developed infective endocarditis 7 months postoperatively, failed medical management, and underwent valve replacement at 14 months. Two-year survival was 96%, with 1 noncardiac death at 16 months. Health-related quality of life in mental, physical, and emotional domains was better than matched norms, global 6.2 vs. 5.0 (p < 0.0001). Conclusions: Using a well-prepared standardized approach, the Ozaki procedure is reproducible with a short learning curve, excellent hemodynamic performance, and good quality of life.

12.
J Am Heart Assoc ; 13(3): e032760, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38293932

ABSTRACT

BACKGROUND: Data regarding permanent pacemaker (PPM) implantation following tricuspid valve surgery (TVS) are limited. We sought to evaluate its incidence, risk factors, and outcomes. METHODS AND RESULTS: Medicare beneficiaries who underwent TVS from 2013 to 2020 were identified. Patients who underwent TVS for endocarditis were excluded. The primary exposure of interest was new PPM after TVS. Outcomes included all-cause mortality and readmission with endocarditis or heart failure on follow-up. Among the 13 294 patients who underwent TVS, 2518 (18.9%) required PPM placement. Risk factors included female sex (relative risk [RR], 1.26 [95% CI, 1.17-1.36], P<0.0001), prior sternotomy (RR, 1.12 [95% CI, 1.02-1.23], P=0.02), preoperative second-degree heart block (RR, 2.20 [95% CI, 1.81-2.69], P<0.0001), right bundle-branch block (RR, 1.21 [95% CI, 1.03-1.41], P=0.019), bifascicular block (RR, 1.43 [95% CI, 1.06-1.93], P=0.02), and prior malignancy (RR, 1.23 [95% CI, 1.01-1.49], P=0.04). Tricuspid valve (TV) replacement was associated with a significantly higher risk of PPM implantation when compared with TV repair (RR, 3.20 [95% CI, 2.16-4.75], P<0.0001). After a median follow-up of 3.1 years, mortality was not different in patients who received PPM compared with patients who did not (hazard ratio [HR], 1.02 [95% CI, 0.93-1.12], P=0.7). PPM placement was not associated with a higher risk of endocarditis but was associated with a higher risk of heart failure readmission (HR, 1.28 [95% CI, 1.14-1.43], P<0.001). CONCLUSIONS: PPM implantation frequently occurs after TVS, notably in female patients and patients undergoing TV replacement. Although mortality is not increased, it is associated with higher rates of heart failure rehospitalization.


Subject(s)
Aortic Valve Stenosis , Endocarditis , Heart Failure , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , United States/epidemiology , Aortic Valve Stenosis/surgery , Cardiac Pacing, Artificial/adverse effects , Incidence , Tricuspid Valve/surgery , Treatment Outcome , Medicare , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Bundle-Branch Block/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Heart Failure/complications , Endocarditis/surgery , Aortic Valve/surgery , Retrospective Studies
13.
Article in English | MEDLINE | ID: mdl-38214683

ABSTRACT

AIMS: The short-term risk of moderate-severe cardiac allograft vasculopathy (CAV) after a low-risk positron emission tomography/computed tomography (PET/CT) is unknown and therefore there is no guidance on how frequently to perform screening. The aim of this study was to assess the rate of progression to moderate-severe CAV as part of an annual screening program. METHODS AND RESULTS: Patients with no history of CAV 2/3 and a low-risk result on initial screening PET/CT (CAV 0/1) were enrolled in the study. The primary outcome was the progression to CAV 2/3 as part of an annual screening program (within 6-18 months of initial scan). PET CAV results were graded according to a published and externally validated diagnostic criteria for CAV.Over the study period, 231 patients underwent an initial PET/CT and had a subsequent evaluation for CAV. In this cohort, 4.3% of patients progressed to CAV 2/3 at a median of 374 days (IQR 363 - 433). Initial PET CAV grade was the most significant patient characteristic associated with progression of CAV, with 17% of patients with PET CAV 1 progressing to CAV 2/3 compared to 1.6% with PET CAV 0 (OR 12.4, 95%CI 3.06-50.3). CONCLUSION: The rate of progression to moderate-severe CAV at 1 year after the lowest-risk PET/CT is low, but approximately 1/6 patients with PET CAV 1 progress to CAV 2/3. Annual screening with PET/CT for select patients with PET CAV 0 may not be warranted. The optimal screening interval awaits confirmation of our findings in multicenter registries.

14.
JACC Cardiovasc Imaging ; 17(1): 1-12, 2024 01.
Article in English | MEDLINE | ID: mdl-37498256

ABSTRACT

BACKGROUND: There are limited data on the sex differences in the hemodynamic progression and outcomes of early-stage aortic stenosis (AS). OBJECTIVES: The authors sought to determine sex differences in hemodynamic progression and outcomes of mild to moderate native AS. METHODS: This was a retrospective observational cohort study including patients with mild to moderate native tricuspid AS from the Cleveland Clinic echocardiographic database between 2008 and 2016 and followed until 2018. All-cause mortality, aortic valve replacement (AVR), and disease progression assessed by annualized changes in echocardiographic parameters were analyzed based on sex. RESULTS: The authors included 2,549 patients (mean age, 74 ± 7 years and 42.5% women) followed over a median duration of 5.7 years. There was no difference in all-cause mortality between sexes irrespective of age, baseline disease severity, progression to severe AS, and receipt of AVR. Relative to men, women had similar all-cause mortality but lower risk of AVR (adjusted HR: 0.81 [95% CI: 0.67-0.91]; P = 0.009) at 10 years. On 1:1 propensity-matched analysis, men had a significantly faster disease progression represented by greater increases in the median of annualized change in mean gradient (2.10 vs 1.15 mm Hg/y, respectively, P < 0.001), maximum transvalvular velocity (0.42 vs 0.28 m/s/y), left ventricular end-diastolic diameters (0.15 vs 0.048 mm/m2.7/y) (P = 0.014). Women have significantly higher left ventricular ejection fraction, filling pressures, and left ventricular septum thickness over time on follow-up echocardiograms compared with men. CONCLUSIONS: Women with mild to moderate AS had slower hemodynamic progression of AS, were more likely to have preserved left ventricular ejection fraction and concentric left ventricular hypertrophy in addition to lower incidence of AVR compared with men despite similar mortality. These findings provide further evidence that there are distinct sex-specific longitudinal echocardiographic and clinical profiles in patients with AS.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Female , Male , Aged , Aged, 80 and over , Stroke Volume , Ventricular Function, Left , Cohort Studies , Follow-Up Studies , Sex Characteristics , Predictive Value of Tests , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Disease Progression , Severity of Illness Index , Retrospective Studies
15.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
16.
Am J Med ; 137(4): 366-369, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38110065

ABSTRACT

BACKGROUND: Patients with low-flow, low-gradient aortic valve stenosis constitute a substantial subset of all severe aortic stenosis patients. However, assessment of true severity of these patients can be challenging. In this analysis, we study the utility of the common carotid artery waveforms to distinguish true from pseudo-severe low-flow low-gradient aortic stenosis. METHODS: This is an observational analysis that included patients who underwent a transthoracic echocardiogram (TTE) and duplex carotid ultrasonography (DCUS) and had low-flow, low-gradient aortic stenosis with reduced left ventricular ejection fraction (LVEF) on the index TTE (LVEF <50%, calculated aortic valve area [AVA] of ≤1.0 cm2, mean and peak gradient of <40 and <64 mm Hg, respectively, and stroke volume index <35 mL/m2). Patients were classified as pseudo-severe and true-severe aortic stenosis based on additional subsequent testing. Differences in various TTE and DCUS waveform parameters across the aortic valve and the common carotid artery were compared between the 2 groups. RESULTS: The study included 30 patients (60 carotid arteries). Fifteen patients were categorized as pseudo-severe and 15 as true severe aortic stenosis. There were no significant differences in calculated AVA, LVEF, stroke volume/stroke volume index, and Doppler Velocity Index in the 2 groups. Mean and peak gradient were higher in patients with true-severe aortic stenosis. Carotid acceleration time (cAT) was significantly prolonged in patients with true-severe compared with pseudo-severe aortic stenosis. A cAT ≥80 ms was 83.3% sensitive and 83.3% specific for true-severe aortic stenosis. CONCLUSION: cAT acceleration time may be used to distinguish true from pseudo-severe low-flow, low-gradient aortic valve stenosis.


Subject(s)
Aortic Valve Stenosis , Ventricular Function, Left , Humans , Stroke Volume , Predictive Value of Tests , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Carotid Arteries , Ultrasonography, Carotid Arteries , Ultrasonography , Severity of Illness Index
18.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38132642

ABSTRACT

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

19.
JACC Case Rep ; 23: 102007, 2023 Oct 04.
Article in English | MEDLINE | ID: mdl-37954951

ABSTRACT

Patients with severe tricuspid regurgitation and right ventricular dysfunction have limited therapeutic options due to anatomic complexity, advanced disease at presentation, and comorbidities. Caval valve implantation is an emerging transcatheter therapy. We present a case series of contrast-sparing caval valve implantation using intravascular ultrasound guidance in patients with renal failure. (Level of Difficulty: Advanced.).

SELECTION OF CITATIONS
SEARCH DETAIL
...