Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
NPJ Prim Care Respir Med ; 32(1): 18, 2022 05 26.
Article in English | MEDLINE | ID: mdl-35618739

ABSTRACT

The study aimed to determine the associations of Peak Inspiratory Flow (PIF), inhalation technique and adherence with health status and exacerbations in participants with COPD using DPI maintenance therapy. This cross-sectional multi-country observational real-world study included COPD participants aged ≥40 years using a DPI for maintenance therapy. PIF was measured three times with the In-Check DIAL G16: (1) typical PIF at resistance of participant's inhaler, (2) maximal PIF at resistance of participant's inhaler, (3) maximal PIF at low resistance. Suboptimal PIF (sPIF) was defined as PIF lower than required for the device. Participants completed questionnaires on health status (Clinical COPD Questionnaire (CCQ)), adherence (Test of Adherence to Inhalers (TAI)) and exacerbations. Inhalation technique was assessed by standardised evaluation of video recordings. Complete data were available from 1434 participants (50.1% female, mean age 69.2 years). GOLD stage was available for 801 participants: GOLD stage I (23.6%), II (54.9%), III (17.4%) and IV (4.1%)). Of all participants, 29% had a sPIF, and 16% were shown able to generate an optimal PIF but failed to do so. sPIF was significantly associated with worse health status (0.226 (95% CI 0.107-0.346), worse units on CCQ; p = 0.001). The errors 'teeth and lips sealed around mouthpiece', 'breathe in', and 'breathe out calmly after inhalation' were related to health status. Adherence was not associated with health status. After correcting for multiple testing, no significant association was found with moderate or severe exacerbations in the last 12 months. To conclude, sPIF is associated with poorer health status. This study demonstrates the importance of PIF assessment in DPI inhalation therapy. Healthcare professionals should consider selecting appropriate inhalers in cases of sPIF.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Aged , Asthma/drug therapy , Cross-Sectional Studies , Dry Powder Inhalers , Female , Health Status , Humans , Male , Pulmonary Disease, Chronic Obstructive/drug therapy
2.
Lancet ; 389(10070): 709-717, 2017 02 18.
Article in English | MEDLINE | ID: mdl-28087069

ABSTRACT

BACKGROUND: miR-122 is an important host factor for hepatitis C virus (HCV) replication. The aim of this study was to assess the safety and tolerability, pharmacokinetics, and antiviral effect of a single dose of RG-101, a hepatocyte targeted N-acetylgalactosamine conjugated oligonucleotide that antagonises miR-122, in patients with chronic HCV infection with various genotypes. METHODS: In this randomised, double-blind, placebo-controlled, multicentre, phase 1B study, patients were randomly assigned to RG-101 or placebo (7:1). We enrolled men and postmenopausal or hysterectomised women (aged 18-65 years) with chronic HCV genotype 1, 3, or 4 infection diagnosed at least 24 weeks before screening who were either treatment naive to or relapsed after interferon-α based therapy. Patients with co-infection (hepatitis B virus or HIV infection), evidence of decompensated liver disease, or a history of hepatocellular carcinoma were excluded. Randomisation was done by an independent, unblinded, statistician using the SAS procedure Proc Plan. The first cohort received one subcutaneous injection of 2 mg/kg RG-101 or placebo; the second cohort received one subcutaneous injection of 4 mg/kg or placebo. Patients were followed up for 8 weeks (all patients) and up to 76 weeks (patients with no viral rebound and excluding those who were randomised to the placebo group) after randomisation. The primary objective was safety and tolerability of RG-101. This trial was registered with EudraCT, number 2013-002978-49. FINDINGS: Between June 4, 2014, and Oct 27, 2014, we enrolled 32 patients with chronic HCV genotype 1 (n=16), 3 (n=10), or 4 (n=6) infections. In the first cohort, 14 patients were randomly assigned to receive 2 mg/kg RG-101 and two patients were randomly assigned to receive placebo, and in the second cohort, 14 patients were randomly assigned to receive 4 mg/kg RG-101 and two patients were randomly assigned to receive placebo. Overall, 26 of the 28 patients dosed with RG-101 reported at least one treatment-related adverse event. At week 4, the median viral load reduction from baseline was 4·42 (IQR 3·23-5·00) and 5·07 (4·19-5·35) log10 IU/mL in patients dosed with 2 mg/kg RG-101 or 4 mg/kg RG-101. Three patients had undetectable HCV RNA levels 76 weeks after a single dose of RG-101. Viral rebound at or before week 12 was associated with the appearance of resistance associated substitutions in miR-122 binding regions in the 5' UTR of the HCV genome. INTERPRETATION: This study showed that one administration of 2 mg/kg or 4 mg/kg RG-101, a hepatocyte targeted N-acetylgalactosamine conjugated anti-miR-122 oligonucleotide, was well tolerated and resulted in substantial viral load reduction in all treated patients within 4 weeks, and sustained virological response in three patients for 76 weeks. FUNDING: Regulus Therapeutics, Inc.


Subject(s)
Hepatitis C, Chronic/drug therapy , MicroRNAs/antagonists & inhibitors , MicroRNAs/therapeutic use , Acetylgalactosamine , Cohort Studies , Double-Blind Method , Female , Humans , Injections, Subcutaneous , Male , MicroRNAs/pharmacokinetics , Middle Aged , Oligonucleotides , Viral Load/drug effects
3.
PLoS One ; 8(4): e61926, 2013.
Article in English | MEDLINE | ID: mdl-23620795

ABSTRACT

UNLABELLED: The 'complex neural pulse'(TM) (CNP) is a neuromodulation protocol employing weak pulsed electromagnetic fields (PEMF). A pioneering paper reported an analgesic effect in healthy humans after 30 minutes of CNP-stimulation using three nested whole head coils. We aimed to devise and validate a stimulator with a novel design entailing a multitude of small coils at known anatomical positions on a head cap, to improve applicability. The main hypothesis was that CNP delivery with this novel device would also increase heat pain thresholds. Twenty healthy volunteers were enrolled in this double-blind, sham-controlled, crossover study. Thirty minutes of PEMF (CNP) or sham was applied to the head. After one week the other treatment was given. Before and after each treatment, primary and secondary outcomes were measured. Primary outcome was heat pain threshold (HPT) measured with thermal quantitative sensory testing. Other outcomes were warmth detection threshold, and aspects of cognition, emotion and motor performance. As hypothesized heat pain threshold was significantly increased after the PEMF stimulation. All other outcomes were unaltered by the PEMF but there was a trend level reduction of cognitive performance after PEMF stimulation as measured by the digit-symbol substitution task. Results from this pilot study suggest that our device is able to stimulate the brain and to modulate its function. This is in agreement with previous studies that used similar magnetic field strengths to stimulate the brain. Specifically, pain control may be achieved with PEMF and for this analgesic effect, coil design does not appear to play a dominant role. In addition, the flexible configuration with small coils on a head cap improves clinical applicability. TRIAL REGISTRATION: Dutch Cochrane Centre NTR1093.


Subject(s)
Health , Magnetics/instrumentation , Pain Threshold/physiology , Adult , Cross-Over Studies , Demography , Double-Blind Method , Electromagnetic Fields , Emotions/physiology , Female , Humans , Male , Motor Activity/physiology , Skin Physiological Phenomena , Young Adult
4.
PLoS One ; 7(8): e43526, 2012.
Article in English | MEDLINE | ID: mdl-22927981

ABSTRACT

Due to the lack of a specific diagnostic tool for neuropathic pain, a grading system to categorize pain as 'definite', 'probable', 'possible' and 'unlikely' neuropathic was proposed. Somatosensory abnormalities are common in neuropathic pain and it has been suggested that a greater number of abnormalities would be present in patients with 'probable' and 'definite' grades. To test this hypothesis, we investigated the presence of somatosensory abnormalities by means of Quantitative Sensory Testing (QST) in patients with a clinical diagnosis of neuropathic pain and correlated the number of sensory abnormalities and sensory profiles to the different grades. Of patients who were clinically diagnosed with neuropathic pain, only 60% were graded as 'definite' or 'probable', while 40% were graded as 'possible' or 'unlikely' neuropathic pain. Apparently, there is a mismatch between a clinical neuropathic pain diagnosis and neuropathic pain grading. Contrary to the expectation, patients with 'probable' and 'definite' grades did not have a greater number of abnormalities. Instead, similar numbers of somatosensory abnormalities were identified for each grade. The profiles of sensory signs in 'definite' and 'probable' neuropathic pain were not significantly different, but different from the 'unlikely' grade. This latter difference could be attributed to differences in the prevalence of patients with a mixture of sensory gain and loss and with sensory loss only. The grading system allows a separation of neuropathic and non-neuropathic pain based on profiles but not on the total number of sensory abnormalities. Our findings indicate that patient selection based on grading of neuropathic pain may provide advantages in selecting homogenous groups for clinical research.


Subject(s)
Neuralgia/diagnosis , Neuralgia/pathology , Sensory Receptor Cells/pathology , Adult , Aged , Case-Control Studies , Cohort Studies , Female , Humans , Male , Middle Aged , Young Adult
5.
PLoS One ; 7(5): e37524, 2012.
Article in English | MEDLINE | ID: mdl-22629414

ABSTRACT

In patients who experience unilateral chronic pain, abnormal sensory perception at the non-painful side has been reported. Contralateral sensory changes in these patients have been given little attention, possibly because they are regarded as clinically irrelevant. Still, bilateral sensory changes in these patients could become clinically relevant if they challenge the correct identification of their sensory dysfunction in terms of hyperalgesia and allodynia. Therefore, we have used the standardized quantitative sensory testing (QST) protocol of the German Research Network on Neuropathic Pain (DFNS) to investigate somatosensory function at the painful side and the corresponding non-painful side in unilateral neuropathic pain patients using gender- and age-matched healthy volunteers as a reference cohort. Sensory abnormalities were observed across all QST parameters at the painful side, but also, to a lesser extent, at the contralateral, non-painful side. Similar relative distributions regarding sensory loss/gain for non-nociceptive and nociceptive stimuli were found for both sides. Once a sensory abnormality for a QST parameter at the affected side was observed, the prevalence of an abnormality for the same parameter at the non-affected side was as high as 57% (for Pressure Pain Threshold). Our results show that bilateral sensory dysfunction in patients with unilateral neuropathic pain is more rule than exception. Therefore, this phenomenon should be taken into account for appropriate diagnostic evaluation in clinical practice. This is particularly true for mechanical stimuli where the 95% Confidence Interval for the prevalence of sensory abnormalities at the non-painful side ranges between 33% and 50%.


Subject(s)
Hyperalgesia/physiopathology , Neuralgia/physiopathology , Pain Threshold/physiology , Sensation Disorders/diagnosis , Adult , Aged , Female , Humans , Hyperalgesia/diagnosis , Male , Middle Aged , Pain Measurement/methods , Physical Stimulation , Sensation Disorders/physiopathology
6.
Int J Psychophysiol ; 75(1): 3-15, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19819271

ABSTRACT

Frequency tagging has been often used to study intramodal attention but not intermodal attention. We used EEG and simultaneous frequency tagging of auditory and visual sources to study intermodal focused and divided attention in detection and discrimination performance. Divided-attention costs were smaller, but still significant, in detection than in discrimination. The auditory steady-state response (SSR) showed no effects of attention at frontocentral locations, but did so at occipital locations where it was evident only when attention was divided between audition and vision. Similarly, the visual SSR at occipital locations was substantially enhanced when attention was divided across modalities. Both effects were equally present in detection and discrimination. We suggest that both effects reflect a common cause: An attention-dependent influence of auditory information processing on early cortical stages of visual information processing, mediated by enhanced effective connectivity between the two modalities under conditions of divided attention.


Subject(s)
Attention/physiology , Brain/physiology , Evoked Potentials, Auditory/physiology , Evoked Potentials, Visual/physiology , Acoustic Stimulation , Analysis of Variance , Auditory Pathways/physiology , Auditory Perception/physiology , Brain Mapping , Discrimination, Psychological , Electroencephalography , Female , Humans , Male , Photic Stimulation , Reaction Time/physiology , Signal Processing, Computer-Assisted , Visual Pathways/physiology , Visual Perception/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...