Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Clin Radiol ; 74(10): 816.e9-816.e17, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31375261

ABSTRACT

AIM: To determine cumulative scan frequencies and estimate lens dose for paediatric computed tomography (CT) head examinations in the context of potential cataract risk. MATERIALS AND METHODS: The cumulative number of head-region CT examinations among a cohort of 410,997 children and young adults who underwent CT in the UK between 1985 and 2014 was calculated. Images from a sample of these head examinations (n=668) were reviewed to determine the level of eye inclusion. Lens dose per scan was estimated using the computer program, NCICT V1.0, for different levels of eye inclusion and exposure settings typical of past and present clinical practice. RESULTS: In total 284,878 patients underwent 448,108 head-region CT examinations. The majority of patients (72%) had a single recorded head-region examination. A small subset (∼1%, n=2,494) underwent ≥10 examinations, while 0.1% (n=387) underwent ≥20. The lens was included within the imaged region for 57% of reviewed routine head examinations. In many cases, this appeared to be intentional, i.e. protocol driven. In others, there appeared to have been an attempt to exclude the eyes through gantry angulation. Estimated lens doses were 20-75 mGy (mean: 47 mGy) where the eye was fully included within the examination range and 2-7 mGy (mean: 3.1 mGy) where the lens was fully excluded. Potential cumulative lens doses ranged from ∼3 mGy to ∼4,700 mGy, with 2,335 patients potentially receiving >500 mGy. CONCLUSION: The majority of young people will receive cumulative lens doses well below 500 mGy, meaning the risk of cataract induction is likely to be very small.


Subject(s)
Head/diagnostic imaging , Lens, Crystalline/radiation effects , Radiation Dosage , Tomography, X-Ray Computed/methods , Adolescent , Cataract/etiology , Cataract/prevention & control , Child , Child, Preschool , Cohort Studies , Dose-Response Relationship, Radiation , Female , Humans , Infant , Infant, Newborn , Male , Patient Positioning , Radiation Exposure/adverse effects , Young Adult
3.
J Radiol Prot ; 36(4): R131-R144, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27893455

ABSTRACT

A large number of investigations into the radiation doses from x-ray guided interventional cardiology procedures in children have been carried out in recent years. A review was conducted of these studies, gathering data on kerma area product (P KA), fluoroscopic screening time (FT), air kerma, and estimates of effective dose and organ doses. The majority of studies focus on P KA and FT with no estimation of dose to the patient. A greater than ten-fold variation in average P KA was found between different studies, even where data were stratified by patient age or weight. Typical values of P KA were 0.6-10 Gy · cm2 (<1 year/10 kg), 1.5-30 Gy · cm2 (1-5 years), 2-40 Gy · cm2 (5-10 years), 5-100 Gy · cm2 (10-16 years) and 10-200 Gy · cm2 (>16 years). P KA was lowest for heart biopsy (0.3-10 Gy · cm2 for all ages combined) and atrial septostomy (0.4-4.0 Gy · cm2), and highest for pulmonary artery angioplasty (1.5-35 Gy · cm2) and right ventricular outflow tract dilatation (139 Gy · cm2). Most estimates of patient dose were in the form of effective dose (typically 3-15 mSv) which is of limited usefulness in individualised risk assessment. Few studies estimated organ doses. Despite advances in radiation protection, recent publications have reported surprisingly large doses, as represented by P KA and air kerma. There is little indication of a fall in these dose indicators over the last 15 years. Nor is there much suggestion of a fall in doses associated with the use of flat panel detectors, as opposed to image intensifiers. An assessment of the impact of radiation dose in the context of overall patient outcome is required.


Subject(s)
Cardiology , Radiation Dosage , Radiation Protection/methods , Radiography, Interventional , Child , Humans , Risk Assessment
4.
Br J Radiol ; 88(1048): 20140852, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25654205

ABSTRACT

OBJECTIVE: To gather data on radiation doses from fluoroscopically guided cardiac catheterization procedures in patients aged under 22 years at multiple centres and over a prolonged period in the UK. To evaluate and explain variation in doses. To estimate patient-specific organ doses and allow for possible future epidemiological analysis of associated cancer risks. METHODS: Patient-specific data including kerma area product and screening times from 10,257 procedures carried out on 7726 patients at 3 UK hospitals from 1994 until 2013 were collected. Organ doses were estimated from these data using a dedicated dosimetry system based on Monte Carlo computer simulations. RESULTS: Radiation doses from these procedures have fallen significantly over the past two decades. The organs receiving the highest doses per procedure were the lungs (median across whole cohort, 20.5 mSv), heart (19.7 mSv) and breasts (13.1 mSv). Median cumulative doses, taking into account multiple procedures, were 23.2, 22.2 and 16.7 mSv for these organs, respectively. Bone marrow doses were relatively low (median per procedure, 3.2 mSv; cumulative, 3.6 mSv). CONCLUSION: Most modern cardiac catheterizations in children are moderately low-dose procedures. Technological advances appear to be the single most important factor in the fall in doses. Patients undergoing heart transplants undergo the most procedures. An epidemiological assessment of cancer risks following these procedures may be possible, especially using older data when doses were higher. ADVANCES IN KNOWLEDGE: This is the first large-scale, patient-specific assessment of organ doses from these procedures in a young population.


Subject(s)
Cardiac Catheterization , Fluoroscopy , Radiation Dosage , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Monte Carlo Method , Risk Factors , Thermoluminescent Dosimetry , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...