Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
MAGMA ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38743376

ABSTRACT

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

2.
J Med Internet Res ; 25: e50865, 2023 12 22.
Article in English | MEDLINE | ID: mdl-38133918

ABSTRACT

Exploring the generative capabilities of the multimodal GPT-4, our study uncovered significant differences between radiological assessments and automatic evaluation metrics for chest x-ray impression generation and revealed radiological bias.


Subject(s)
Radiology , Humans , X-Rays , Radiography , Benchmarking , Perception
3.
Tomography ; 9(5): 1839-1856, 2023 10 06.
Article in English | MEDLINE | ID: mdl-37888738

ABSTRACT

Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.


Subject(s)
Artifacts , Liver , Retrospective Studies , Reproducibility of Results , Liver/diagnostic imaging , Motion , Diffusion Magnetic Resonance Imaging/methods
4.
J Clin Med ; 12(11)2023 May 25.
Article in English | MEDLINE | ID: mdl-37297861

ABSTRACT

Trimalleolar ankle fractures show a bimodal age distribution, affecting younger men and older women. Postmenopausal women often exhibit low bone mineral density, which contributes to a higher prevalence of osteoporotic-related fractures. The primary goal of this study was to analyse the association of patient characteristics with the cortical bone thickness of the distal tibia (CBTT) in trimalleolar ankle fractures. METHODS: A total of 193 patients with a trimalleolar ankle fracture treated between 2011 and 2020 were included. Patient registries were reviewed regarding demographics, mechanism, and type of injury. The CBTT was assessed in radiographs and CT images. The FRAX score was calculated to estimate the probability for an osteoporotic fracture. A multivariable regression model was calculated to identify independent variables affecting the cortical bone thickness of the distal tibia. RESULTS: Patients older than 55 years were 4.22 (95% CI: 2.12; 8.38) times more likely to be female. In the multivariable regression analysis, female sex (ß -0.508, 95% CI: -0.739; -0.278, p < 0.001) and a higher age (ß -0.009, 95% CI: -0.149; -0.003, p = 0.002) were independent variables associated with a lower CBTT. Patients with a CBTT < 3.5 mm had a higher 10-year probability for a major osteoporotic fracture (12% vs. 7.75%; p = 0.001). CONCLUSIONS: The assessment of the peripheral bone quality in routine computed tomography demonstrated that higher age and female sex are significantly associated with reduced cortical bone thickness of the distal tibia. Patients with a lower CBTT showed a higher probability for a subsequent osteoporotic fracture. In female patients with reduced distal tibial bone quality and associated risk factors, an osteoporosis assessment should be evaluated.

5.
Eur Radiol ; 33(10): 6892-6901, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37133518

ABSTRACT

OBJECTIVES: To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS: Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS: High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS: High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT: This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS: • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.


Subject(s)
Pancreatic Intraductal Neoplasms , Pancreatic Neoplasms , Humans , Retrospective Studies , Pancreatic Neoplasms/diagnostic imaging , Signal-To-Noise Ratio , Diffusion Magnetic Resonance Imaging/methods , Pancreas
6.
Abdom Radiol (NY) ; 48(7): 2449-2455, 2023 07.
Article in English | MEDLINE | ID: mdl-37160473

ABSTRACT

Active surveillance (AS) is now included in all major guidelines for patients with low-risk PCa and selected patients with intermediate-risk PCa. Several studies have highlighted the potential benefit of multiparametric magnetic resonance imaging (mpMRI) in AS and it has been adopted in some guidelines. However, uncertainty remains about whether serial mpMRI can help to safely reduce the number of required repeat biopsies under AS. In 2017, the European School of Oncology initiated the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) panel which proposed the PRECISE scoring system to assess the likelihood of radiological tumor progression on serial mpMRI. The PRECISE scoring system remains the only major system evaluated in multiple publications. In this review article, we discuss the current body of literature investigating the application of PRECISE as it is not as yet an established standard in mpMRI reporting. We delineate the strengths of PRECISE and its potential added value. Also, we underline potential weaknesses of the PRECISE scoring system, which might be tackled in future versions to further increase its value in AS.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms , Male , Humans , Magnetic Resonance Imaging/methods , Watchful Waiting/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiography
7.
Eur Radiol ; 33(8): 5840-5850, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37074425

ABSTRACT

OBJECTIVES: Previous trial results suggest that only a small number of patients with non-metastatic renal cell carcinoma (RCC) benefit from adjuvant therapy. We assessed whether the addition of CT-based radiomics to established clinico-pathological biomarkers improves recurrence risk prediction for adjuvant treatment decisions. METHODS: This retrospective study included 453 patients with non-metastatic RCC undergoing nephrectomy. Cox models were trained to predict disease-free survival (DFS) using post-operative biomarkers (age, stage, tumor size and grade) with and without radiomics selected on pre-operative CT. Models were assessed using C-statistic, calibration, and decision curve analyses (repeated tenfold cross-validation). RESULTS: At multivariable analysis, one of four selected radiomic features (wavelet-HHL_glcm_ClusterShade) was prognostic for DFS with an adjusted hazard ratio (HR) of 0.44 (p = 0.02), along with American Joint Committee on Cancer (AJCC) stage group (III versus I, HR 2.90; p = 0.002), grade 4 (versus grade 1, HR 8.90; p = 0.001), age (per 10 years HR 1.29; p = 0.03), and tumor size (per cm HR 1.13; p = 0.003). The discriminatory ability of the combined clinical-radiomic model (C = 0.80) was superior to that of the clinical model (C = 0.78; p < 0.001). Decision curve analysis revealed a net benefit of the combined model when used for adjuvant treatment decisions. At an exemplary threshold probability of ≥ 25% for disease recurrence within 5 years, using the combined versus the clinical model was equivalent to treating 9 additional patients (per 1000 assessed) who would recur without treatment (i.e., true-positive predictions) with no increase in false-positive predictions. CONCLUSION: Adding CT-based radiomic features to established prognostic biomarkers improved post-operative recurrence risk assessment in our internal validation study and may help guide decisions regarding adjuvant therapy. KEY POINTS: In patients with non-metastatic renal cell carcinoma undergoing nephrectomy, CT-based radiomics combined with established clinical and pathological biomarkers improved recurrence risk assessment. Compared to a clinical base model, the combined risk model enabled superior clinical utility if used to guide decisions on adjuvant treatment.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Humans , Child , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/surgery , Retrospective Studies , Neoplasm Recurrence, Local/surgery , Nephrectomy , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Kidney Neoplasms/drug therapy , Tomography, X-Ray Computed/methods
8.
Invest Radiol ; 58(3): 199-208, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36070524

ABSTRACT

OBJECTIVE: Before implementing radiomics in routine clinical practice, comprehensive knowledge about the repeatability and reproducibility of radiomic features is required. The aim of this study was to systematically investigate the influence of image processing parameters on radiomic features from magnetic resonance imaging (MRI) in terms of feature values as well as test-retest repeatability. MATERIALS AND METHODS: Utilizing a phantom consisting of 4 onions, 4 limes, 4 kiwifruits, and 4 apples, we acquired a test-retest dataset featuring 3 of the most commonly used MRI sequences on a 3 T scanner, namely, a T1-weighted, a T2-weighted, and a fluid-attenuated inversion recovery sequence, each at high and low resolution. After semiautomatic image segmentation, image processing with systematic variation of image processing parameters was performed, including spatial resampling, intensity discretization, and intensity rescaling. For each respective image processing setting, a total of 45 radiomic features were extracted, corresponding to the following 7 matrices/feature classes: conventional indices, histogram matrix, shape matrix, gray-level zone length matrix, gray-level run length matrix, neighboring gray-level dependence matrix, and gray-level cooccurrence matrix. Systematic differences of individual features between different resampling steps were assessed using 1-way analysis of variance with Tukey-type post hoc comparisons to adjust for multiple testing. Test-retest repeatability of radiomic features was measured using the concordance correlation coefficient, dynamic range, and intraclass correlation coefficient. RESULTS: Image processing influenced radiological feature values. Regardless of the acquired sequence and feature class, significant differences ( P < 0.05) in feature values were found when the size of the resampled voxels was too large, that is, bigger than 3 mm. Almost all higher-order features depended strongly on intensity discretization. The effects of intensity rescaling were negligible except for some features derived from T1-weighted sequences. For all sequences, the percentage of repeatable features (concordance correlation coefficient and dynamic range ≥ 0.9) varied considerably depending on the image processing settings. The optimal image processing setting to achieve the highest percentage of stable features varied per sequence. Irrespective of image processing, the fluid-attenuated inversion recovery sequence in high-resolution overall yielded the highest number of stable features in comparison with the other sequences (89% vs 64%-78% for the respective optimal image processing settings). Across all sequences, the most repeatable features were generally obtained for a spatial resampling close to the originally acquired voxel size and an intensity discretization to at least 32 bins. CONCLUSION: Variation of image processing parameters has a significant impact on the values of radiomic features as well as their repeatability. Furthermore, the optimal image processing parameters differ for each MRI sequence. Therefore, it is recommended that these processing parameters be determined in corresponding test-retest scans before clinical application. Extensive repeatability, reproducibility, and validation studies as well as standardization are required before quantitative image analysis and radiomics can be reliably translated into routine clinical care.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Reproducibility of Results , Image Processing, Computer-Assisted/methods , Phantoms, Imaging
9.
Cancers (Basel) ; 14(23)2022 Nov 22.
Article in English | MEDLINE | ID: mdl-36497223

ABSTRACT

BACKGROUND: To assess the performance of prospectively accelerated and deep learning (DL) reconstructed T2-weighted (T2w) imaging in volunteers and patients with histologically proven prostate cancer (PCa). METHODS: Prospectively undersampled T2w datasets were acquired with acceleration factors of 1.7 (reference), 3.4 and 4.8 in 10 healthy volunteers and 23 patients with histologically proven PCa. Image reconstructions using compressed SENSE (C-SENSE) and a combination of C-SENSE and DL-based artificial intelligence (C-SENSE AI) were analyzed. Qualitative image comparison was performed using a 6-point Likert scale (overall image quality, noise, motion artifacts, lesion detection, diagnostic certainty); the T2 and PI-RADS scores were compared between the two reconstructions. Additionally, quantitative image parameters were assessed (apparent SNR, apparent CNR, lesion size, line profiles). RESULTS: All C-SENSE AI-reconstructed images received a significantly higher qualitative rating compared to the C-SENSE standard images. Analysis of the quantitative parameters supported this finding, with significantly higher aSNR and aCNR. The line profiles demonstrated a significantly steeper signal change at the border of the prostatic lesion and the adjacent normal tissue in the C-SENSE AI-reconstructed images, whereas the T2 and PI-RADS scores as well as the lesion size did not differ. CONCLUSION: In this prospective study, we demonstrated the clinical feasibility of a novel C-SENSE AI reconstruction enabling a 58% acceleration in T2w imaging of the prostate while obtaining significantly better image quality.

10.
Eur J Nucl Med Mol Imaging ; 50(1): 115-129, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36074156

ABSTRACT

PURPOSE: Pancreatic ductal adenocarcinoma (PDAC) is a molecularly heterogeneous tumor entity with no clinically established imaging biomarkers. We hypothesize that tumor morphology and physiology, including vascularity and perfusion, show variations that can be detected by differences in contrast agent (CA) accumulation measured non-invasively. This work seeks to establish imaging biomarkers for tumor stratification and therapy response monitoring in PDAC, based on this hypothesis. METHODS AND MATERIALS: Regional CA accumulation in PDAC was correlated with tumor vascularization, stroma content, and tumor cellularity in murine and human subjects. Changes in CA distribution in response to gemcitabine (GEM) were monitored longitudinally with computed tomography (CT) Hounsfield Units ratio (HUr) of tumor to the aorta or with magnetic resonance imaging (MRI) ΔR1 area under the curve at 60 s tumor-to-muscle ratio (AUC60r). Tissue analyses were performed on co-registered samples, including endothelial cell proliferation and cisplatin tissue deposition as a surrogate of chemotherapy delivery. RESULTS: Tumor cell poor, stroma-rich regions exhibited high CA accumulation both in human (meanHUr 0.64 vs. 0.34, p < 0.001) and mouse PDAC (meanAUC60r 2.0 vs. 1.1, p < 0.001). Compared to the baseline, in vivo CA accumulation decreased specifically in response to GEM treatment in a subset of human (HUr -18%) and mouse (AUC60r -36%) tumors. Ex vivo analyses of mPDAC showed reduced cisplatin delivery (GEM: 0.92 ± 0.5 mg/g, vs. vehicle: 3.1 ± 1.5 mg/g, p = 0.004) and diminished endothelial cell proliferation (GEM: 22.3% vs. vehicle: 30.9%, p = 0.002) upon GEM administration. CONCLUSION: In PDAC, CA accumulation, which is related to tumor vascularization and perfusion, inversely correlates with tumor cellularity. The standard of care GEM treatment results in decreased CA accumulation, which impedes drug delivery. Further investigation is warranted into potentially detrimental effects of GEM in combinatorial therapy regimens.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Humans , Mice , Animals , Cisplatin/therapeutic use , Xenograft Model Antitumor Assays , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/drug therapy , Carcinoma, Pancreatic Ductal/pathology , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/drug therapy , Pancreatic Neoplasms/pathology , Neovascularization, Pathologic/diagnostic imaging , Neovascularization, Pathologic/drug therapy , Biomarkers , Tomography, X-Ray Computed , Magnetic Resonance Imaging , Tomography , Cell Line, Tumor , Gemcitabine , Pancreatic Neoplasms
11.
Front Oncol ; 12: 938703, 2022.
Article in English | MEDLINE | ID: mdl-35865465

ABSTRACT

Introduction: Exposure of the posterior skull base and the cerebellopontine angle is challenging due to important neurovascular structures. The retrosigmoid approach (RSA) has become the standard method used in surgery. We report our experiences with RSAs regarding technical obstacles, complications, and approach-related outcomes. Materials and Methods: We performed a retrospective chart review at a tertiary neurosurgical center between January 2007 and September 2020. We included all patients undergoing surgery for oncologic lesions through RSAs, concentrating on surgical technique, postoperative outcome, and complications. Results: A total of 449 RSAs were included. The median age at the time of surgery was 58 years; 168 (37.4%) were male and 281 (62.6%) were female. The median approach surface was 7.8 cm2. The median tumor volume was 5.9 cm3. The median Clavien-Dindo grade was 2, the total complication rate was 28.7%, and gross total resection (GTR) was 78.8%. Findings revealed that tumor volume had no significant impact on postoperative complications in general (p = 0.086) but had a significant impact on postoperative hemorrhage (p = 0.037) and hydrocephalus (p = 0.019). Tumor volume was significant for several preoperative symptoms (p < 0.001). The extent of the approach had no significant impact on complications in general (p = 0.120) but was significant regarding postoperative cerebrospinal fluid (CSF) leaks (p = 0.008). Craniotomy size was not significant regarding GTR (p = 0.178); GTR rate just missed significant correlation with tumor volume (p = 0.056). However, in the case of vestibular schwannomas, the size of craniotomy was important for GTR (p = 0.041). Conclusion: Tumor volume has an important impact on preoperative symptoms as well as on postoperative complications. Although the extent of the craniotomy barely missed significance regarding GTR, a correlation can be assumed. Thus, the extent of craniotomy should be taken into presurgical consideration, especially in the case of postoperative CSF leaks. Regarding vestibular schwannomas, craniotomy size plays an important role in achieving satisfactory oncological outcomes. Different approaches should be selected where necessary regarding superior resection rates.

12.
Eur J Trauma Emerg Surg ; 48(5): 4181-4188, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35348840

ABSTRACT

PURPOSE: Different classification systems have been developed for ankle fractures. In recent years, the posterior malleolus has gained in importance and led to computed tomography (CT)-based classification systems. The aim of the study was to analyse their reliability, fracture patterns and influence on treatment strategy. METHODS: Patients with a trimalleolar ankle fracture treated between 2011 and 2020 with preoperative radiographs and CT images were included. The blinded images were independently classified by three reviewers according to the AO/OTA, Herscovici, Bartonícek, Mason and Haraguchi classifications. The interobserver reliability was calculated by Fleiss' kappa (κ). CT images were analysed to determine the dimensions of the posterior malleolus fragments. Patient registries were reviewed regarding the treatment data. RESULTS: A total of 193 patients were included. The AO/OTA classification showed almost perfect inter- and intraobserver reliability (Fleiss' κ = 0.86, 95% CI 0.82-0.90). Regarding the posterior malleolus, the Bartonícek classification demonstrated the highest reliability (Fleiss' κ = 0.78, 95% CI 0.73-0.83). The Herscovici classification only reached moderate reliability for medial malleolus fractures (Fleiss' κ = 0.59, 95% CI 0.54-0.65). There was a trend towards direct fixation of the posterior malleolus in the last 3 years of the observation period (OR: 2.49, 95% CI 1.03-5.99). CONCLUSION: In trimalleolar ankle fractures, the AO/OTA classification is a reliable system to characterize the type of fracture, but it fails to provide solid information about the posterior malleolus. Nowadays, treatment recommendations for trimalleolar ankle fractures focus on the configuration of the posterior malleolus; therefore, the results of this study advocate the use of the Bartonícek classification as a reliable tool to guide treatment.


Subject(s)
Ankle Fractures , Ankle Fractures/diagnostic imaging , Ankle Fractures/surgery , Fracture Fixation, Internal , Humans , Radiography , Reproducibility of Results , Tibia , Tomography, X-Ray Computed/methods
13.
EMBO Mol Med ; 14(4): e14876, 2022 04 07.
Article in English | MEDLINE | ID: mdl-35119792

ABSTRACT

Despite the advance and success of precision oncology in gastrointestinal cancers, the frequency of molecular-informed therapy decisions in pancreatic ductal adenocarcinoma (PDAC) is currently neglectable. We present a longitudinal precision oncology platform based on functional model systems, including patient-derived organoids, to identify chemotherapy-induced vulnerabilities. We demonstrate that treatment-induced tumor cell plasticity in vivo distinctly changes responsiveness to targeted therapies, without the presence of a selectable genetic marker, indicating that tumor cell plasticity can be functionalized. By adding a mechanistic layer to precision oncology, adaptive processes of tumors under therapy can be exploited, particularly in highly plastic tumors, such as pancreatic cancer.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Carcinoma, Pancreatic Ductal/drug therapy , Carcinoma, Pancreatic Ductal/genetics , Carcinoma, Pancreatic Ductal/pathology , Humans , Organoids/pathology , Pancreatic Neoplasms/drug therapy , Pancreatic Neoplasms/pathology , Precision Medicine , Pancreatic Neoplasms
14.
Cancers (Basel) ; 14(3)2022 Jan 18.
Article in English | MEDLINE | ID: mdl-35158737

ABSTRACT

BACKGROUND: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. MATERIALS AND METHODS: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1-4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). RESULTS: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. CONCLUSION: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.

15.
Invest Radiol ; 57(3): 171-177, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34524173

ABSTRACT

MATERIALS AND METHODS: Imaging phantoms were scanned twice on 3 computed tomography scanners from 2 different manufactures with varying tube voltages and currents. Phantoms were segmented, and features were extracted using PyRadiomics and a pretrained CNN. After standardization the concordance correlation coefficient (CCC), mean feature variance, feature range, and the coefficient of variant were calculated to assess feature robustness. In addition, the cosine similarity was calculated for the vectorized activation maps for an exemplary phantom. For the in vivo comparison, the radiomics and CNN features of 30 patients with hepatocellular carcinoma (HCC) and 30 patients with hepatic colon carcinoma metastasis were compared. RESULTS: In total, 851 radiomics features and 256 CNN features were extracted for each phantom. For all phantoms, the global CCC of the CNN features was above 98%, whereas the highest CCC for the radiomics features was 36%. The mean feature variance and feature range was significantly lower for the CNN features. Using a coefficient of variant ≤0.2 as a threshold to define robust features and averaging across all phantoms 346 of 851 (41%) radiomics features and 196 of 256 (77%) CNN features were found to be robust. The cosine similarity was greater than 0.98 for all scanner and parameter variations. In the retrospective analysis, 122 of the 256 CNN (49%) features showed significant differences between HCC and hepatic colon metastasis. DISCUSSION: Convolutional neural network features were more stable compared with radiomics features against technical variations. Moreover, the possibility of tumor entity differentiation based on CNN features was shown. Combined with visualization methods, CNN features are expected to increase reproducibility of quantitative image representations. Further studies are warranted to investigate the impact of feature stability on radiological image-based prediction of clinical outcomes.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Carcinoma, Hepatocellular/diagnostic imaging , Humans , Liver Neoplasms/diagnostic imaging , Neural Networks, Computer , Phantoms, Imaging , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/methods
16.
Rofo ; 194(3): 272-280, 2022 03.
Article in English, German | MEDLINE | ID: mdl-34794186

ABSTRACT

PURPOSE: Comparison of puncture deviation and puncture duration between computed tomography (CT)- and C-arm CT (CACT)-guided puncture performed by residents in training (RiT). METHODS: In a cohort of 25 RiTs enrolled in a research training program either CT- or CACT-guided puncture was performed on a phantom. Prior to the experiments, the RiT's level of training, experience playing a musical instrument, video games, and ball sports, and self-assessed manual skills and spatial skills were recorded. Each RiT performed two punctures. The first puncture was performed with a transaxial or single angulated needle path and the second with a single or double angulated needle path. Puncture deviation and puncture duration were compared between the procedures and were correlated with the self-assessments. RESULTS: RiTs in both the CT guidance and CACT guidance groups did not differ with respect to radiologic experience (p = 1), angiographic experience (p = 0.415), and number of ultrasound-guided puncture procedures (p = 0.483), CT-guided puncture procedures (p = 0.934), and CACT-guided puncture procedures (p = 0.466). The puncture duration was significantly longer with CT guidance (without navigation tool) than with CACT guidance with navigation software (p < 0.001). There was no significant difference in the puncture duration between the first and second puncture using CT guidance (p = 0.719). However, in the case of CACT, the second puncture was significantly faster (p = 0.006). Puncture deviations were not different between CT-guided and CACT-guided puncture (p = 0.337) and between the first and second puncture of CT-guided and CACT-guided puncture (CT: p = 0.130; CACT: p = 0.391). The self-assessment of manual skills did not correlate with puncture deviation (p = 0.059) and puncture duration (p = 0.158). The self-assessed spatial skills correlated positively with puncture deviation (p = 0.011) but not with puncture duration (p = 0.541). CONCLUSION: The RiTs achieved a puncture deviation that was clinically adequate with respect to their level of training and did not differ between CT-guided and CACT-guided puncture. The puncture duration was shorter when using CACT. CACT guidance with navigation software support has a potentially steeper learning curve. Spatial skills might accelerate the learning of image-guided puncture. KEY POINTS: · The CT-guided and CACT-guided puncture experience of the RiTs selected as part of the program "Researchers for the Future" of the German Roentgen Society was adequate with respect to the level of training.. · Despite the lower collective experience of the RiTs with CACT-guided puncture with navigation software assistance, the learning curve regarding CACT-guided puncture may be faster compared to the CT-guided puncture technique.. · If the needle path is complex, CACT guidance with navigation software assistance might have an advantage over CT guidance.. CITATION FORMAT: · Meine TC, Hinrichs JB, Werncke T et al. Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology. Fortschr Röntgenstr 2022; 194: 272 - 280.


Subject(s)
Radiology , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Punctures/methods , Software , Tomography, X-Ray Computed/methods
17.
Magn Reson Imaging ; 87: 1-6, 2022 04.
Article in English | MEDLINE | ID: mdl-34808306

ABSTRACT

OBJECTIVES: To prospectively evaluate an L1 regularized iterative SENSE reconstruction (L1-R SENSE) to eliminate band-like artifacts frequently seen with parallel imaging (SENSE) at high acceleration factors in high resolution diffusion weighted magnetic resonance imaging of the pancreas. METHODS: Fourteen patients with pancreatic ductal adenocarcinoma (PDAC) underwent respiratory triggered DWI ss-EPI at a resolution of 2.5 × 2.5 × 3 mm3 with uniform undersampling in the phase encoding direction (AP axis) with an acceleration factor of 4. Data were reconstructed using the standard SENSE reconstruction routine of the vendor and an iterative SENSE reconstruction employing L1 regularization after a wavelet sparsifying transformation (L1-R SENSE). Retrospective reconstruction of the data with a lower number of averages was performed using both reconstruction methods. Two radiologists independently assessed noise artifacts, anatomical details and image quality (IQ) subjectively with a 4-point scale. Apparent diffusion coefficient (ADC) and covariance (CV) of ADC estimated from images reconstructed at a different number of averages for PDAC and the normal pancreas were assessed. RESULTS: L1-R SENSE resulted in higher IQ and less noise artifacts than SENSE. Anatomical details were significantly higher for SENSE in one reader. Mean ADC of PDAC and normal pancreas were significantly higher for L1-R SENSE than SENSE. L1-R SENSE revealed lower CV of ADC for normal pancreas compared to SENSE, whereas no difference was noted for PDAC. CONCLUSION: Compared with traditional SENSE reconstruction, L1-R SENSE effectively reduces band-like noise and improves the robustness of the ADC estimation from acquisitions using single-shot DW-EPI of the pancreas.


Subject(s)
Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Artifacts , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Humans , Pancreas/diagnostic imaging , Pancreas/pathology , Reproducibility of Results , Retrospective Studies
18.
EJNMMI Res ; 11(1): 70, 2021 Jul 28.
Article in English | MEDLINE | ID: mdl-34322781

ABSTRACT

PURPOSE: In this prospective exploratory study, we evaluated the feasibility of [18F]fluorodeoxyglucose ([18F]FDG) PET/MRI-based chemotherapy response prediction in pancreatic ductal adenocarcinoma at two weeks upon therapy onset. MATERIAL AND METHODS: In a mixed cohort, seventeen patients treated with chemotherapy in neoadjuvant or palliative intent were enrolled. All patients were imaged by [18F]FDG PET/MRI before and two weeks after onset of chemotherapy. Response per RECIST1.1 was then assessed at 3 months [18F]FDG PET/MRI-derived parameters (MTV50%, TLG50%, MTV2.5, TLG2.5, SUVmax, SUVpeak, ADCmax, ADCmean and ADCmin) were assessed, using multiple t-test, Man-Whitney-U test and Fisher's exact test for binary features. RESULTS: At 72 ± 43 days, twelve patients were classified as responders and five patients as non-responders. An increase in ∆MTV50% and ∆ADC (≥ 20% and 15%, respectively) and a decrease in ∆TLG50% (≤ 20%) at 2 weeks after chemotherapy onset enabled prediction of responders and non-responders, respectively. Parameter combinations (∆TLG50% and ∆ADCmax or ∆MTV50% and ∆ADCmax) further improved discrimination. CONCLUSION: Multiparametric [18F]FDG PET/MRI-derived parameters, in particular indicators of a change in tumor glycolysis and cellularity, may enable very early chemotherapy response prediction. Further prospective studies in larger patient cohorts are recommended to their clinical impact.

19.
Eur J Radiol ; 142: 109843, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34274842

ABSTRACT

OBJECTIVES: To evaluate sparse sampling computed tomography (SpSCT) for detection of endoleak after endovascular aortic repair (EVAR) at different dose levels in terms of subjective image criteria and diagnostic accuracy. METHODS: Twenty clinically indicated computed tomography aortic angiography (CTA) scans were used to obtain simulated low-dose scans with 100%, 50%, 25%, 12.5% and 6.25% of the applicated clinical dose, resulting in five dose levels (DL). From full sampling (FS) data sets, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to generate simulated sparse sampling scans. All examinations were evaluated by four blinded radiologists regarding subjective image criteria and diagnostic performance. RESULTS: Sensitivity was higher than 93% in 4-SpSCT at the 25% DL which is the same as with FS at full dose (100% DL). High accuracies and relative high AUC-values were obtained for 2- and 4-SpSCT down to the 12.5% DL, while for FS similar values were shown down to 25% DL only. Subjective image quality was significantly higher for 4-SpSCT compared to FS at each dose level. More than 90% of all cases were rated with a high or medium confidence for FS and 2-SpSCT at the 50% DL and for 4-SpSCT at the 25% DL. At DL 25% and 12.5%, more cases showed a high confidence using 2- and 4-SpSCT compared with FS. CONCLUSIONS: Via SpSCT, a dose reduction down to a 25% dose level (mean effective dose of 1.49 mSv in the current study) for CTA is possible while maintaining high image quality and full diagnostic confidence.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/surgery , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endoleak/diagnostic imaging , Endovascular Procedures/adverse effects , Humans , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
20.
Front Surg ; 8: 602181, 2021.
Article in English | MEDLINE | ID: mdl-33937312

ABSTRACT

Incisional hernia is a frequent consequence of major surgery. Most repairs augment the abdominal wall with artificial meshes fixed to the tissues with sutures, tacks, or glue. Pain and recurrences plague at least 10-20% of the patients after repair of the abdominal defect. How should a repair of incisional hernias be constructed to achieve durability? Incisional hernia repair can be regarded as a compound technique. The biomechanical properties of a compound made of tissue, textile, and linking materials vary to a large extent. Tissues differ in age, exercise levels, and comorbidities. Textiles are currently optimized for tensile strength, but frequently fail to provide tackiness, dynamic stiction, and strain resistance to pulse impacts. Linking strength with and without fixation devices depends on the retention forces between surfaces to sustain stiction under dynamic load. Impacts such a coughing or sharp bending can easily overburden clinically applied composite structures and can lead to a breakdown of incisional hernia repair. Our group developed a bench test with tissues, fixation, and textiles using dynamic intermittent strain (DIS), which resembles coughing. Tissue elasticity, the size of the hernia under pressure, and the area of instability of the abdominal wall of the individual patient was assessed with low-dose computed tomography of the abdomen preoperatively. A surgical concept was developed based on biomechanical considerations. Observations in a clinical registry based on consecutive patients from four hospitals demonstrate low failure rates and low pain levels after 1 year. Here, results from the bench test, the application of CT abdomen with Valsalva's maneuver, considerations of the surgical concept, and the clinical application of our approach are outlined.

SELECTION OF CITATIONS
SEARCH DETAIL
...