Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 148
Filter
1.
J Magn Reson Imaging ; 2024 May 04.
Article in English | MEDLINE | ID: mdl-38703134

ABSTRACT

BACKGROUND: Cartilage T2 can detect joints at risk of developing osteoarthritis. The quantitative double-echo steady state (qDESS) sequence is attractive for knee cartilage T2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T2 is essential to profiling the technical performance of this biomarker. PURPOSE: To examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation. STUDY TYPE: Prospective. SUBJECTS: 11 uninjured participants (age: 28 ± 3 years; 8 (73%) female). FIELD STRENGTH/SEQUENCE: 3-T, qDESS. ASSESSMENT: Test-retest T2 maps were acquired twice on the same day and with a 1-week interval between scans. For each acquisition, average cartilage T2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep-learning open-source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test-retest T2 values from matching regions were used to evaluate reproducibility. STATISTICAL TESTS: Coefficients of variation (%CV), root-mean-square-average-CV (%RMSA-CV), and intraclass correlation coefficients (ICCs) assessed test-retest T2 reproducibility. The median of test-retest standard deviations was used for T2 precision. Bland-Altman (BA) analyses examined test-retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05. RESULTS: All cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T2 CVs and RMSA-CVs of ≤5%. T2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test-retest T2 precision was <1.3 msec. The T2 SDD was 3.8 msec. DATA CONCLUSION: Excellent CV and RMSA-CV reproducibility may suggest that qDESS T2 increases or decreases >5% (3.8 msec) could represent changes to cartilage composition. TECHNICAL EFFICACY: Stage 2.

2.
Magn Reson Med ; 92(2): 519-531, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38623901

ABSTRACT

PURPOSE: Diffusion-weighted (DW) imaging provides a useful clinical contrast, but is susceptible to motion-induced dephasing caused by the application of strong diffusion gradients. Phase navigators are commonly used to resolve shot-to-shot motion-induced phase in multishot reconstructions, but poor phase estimates result in signal dropout and Apparent Diffusion Coefficient (ADC) overestimation. These artifacts are prominent in the abdomen, a region prone to involuntary cardiac and respiratory motion. To improve the robustness of DW imaging in the abdomen, region-based shot rejection schemes that selectively weight regions where the shot-to-shot phase is poorly estimated were evaluated. METHODS: Spatially varying weights for each shot, reflecting both the accuracy of the estimated phase and the degree of subvoxel dephasing, were estimated from the phase navigator magnitude images. The weighting was integrated into a multishot reconstruction using different formulations and phase navigator resolutions and tested with different phase navigator resolutions in multishot DW-echo Planar Imaging acquisitions of the liver and pancreas, using conventional monopolar and velocity-compensated diffusion encoding. Reconstructed images and ADC estimates were compared qualitatively. RESULTS: The proposed region-based shot rejection reduces banding and signal dropout artifacts caused by physiological motion in the liver and pancreas. Shot rejection allows conventional monopolar diffusion encoding to achieve median ADCs in the pancreas comparable to motion-compensated diffusion encoding, albeit with a greater spread of ADCs. CONCLUSION: Region-based shot rejection is a linear reconstruction that improves the motion robustness of multi-shot DWI and requires no sequence modifications.


Subject(s)
Abdomen , Algorithms , Artifacts , Diffusion Magnetic Resonance Imaging , Humans , Diffusion Magnetic Resonance Imaging/methods , Abdomen/diagnostic imaging , Image Processing, Computer-Assisted/methods , Pancreas/diagnostic imaging , Liver/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Motion , Echo-Planar Imaging/methods , Image Enhancement/methods , Adult
3.
Magn Reson Med ; 92(2): 586-604, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38688875

ABSTRACT

PURPOSE: Abdominal imaging is frequently performed with breath holds or respiratory triggering to reduce the effects of respiratory motion. Diffusion weighted sequences provide a useful clinical contrast but have prolonged scan times due to low signal-to-noise ratio (SNR), and cannot be completed in a single breath hold. Echo-planar imaging (EPI) is the most commonly used trajectory for diffusion weighted imaging but it is susceptible to off-resonance artifacts. A respiratory resolved, three-dimensional (3D) diffusion prepared sequence that obtains distortionless diffusion weighted images during free-breathing is presented. Techniques to address the myriad of challenges including: 3D shot-to-shot phase correction, respiratory binning, diffusion encoding during free-breathing, and robustness to off-resonance are described. METHODS: A twice-refocused, M1-nulled diffusion preparation was combined with an RF-spoiled gradient echo readout and respiratory resolved reconstruction to obtain free-breathing diffusion weighted images in the abdomen. Cartesian sampling permits a sampling density that enables 3D shot-to-shot phase navigation and reduction of transient fat artifacts. Theoretical properties of a region-based shot rejection are described. The region-based shot rejection method was evaluated with free-breathing (normal and exaggerated breathing), and respiratory triggering. The proposed sequence was compared in vivo with multishot DW-EPI. RESULTS: The proposed sequence exhibits no evident distortion in vivo when compared to multishot DW-EPI, robustness to B0 and B1 field inhomogeneities, and robustness to motion from different respiratory patterns. CONCLUSION: Acquisition of distortionless, diffusion weighted images is feasible during free-breathing with a b-value of 500 s/mm2, scan time of 6 min, and a clinically viable reconstruction time.


Subject(s)
Abdomen , Artifacts , Diffusion Magnetic Resonance Imaging , Imaging, Three-Dimensional , Humans , Diffusion Magnetic Resonance Imaging/methods , Abdomen/diagnostic imaging , Imaging, Three-Dimensional/methods , Respiration , Algorithms , Signal-To-Noise Ratio , Reproducibility of Results , Image Interpretation, Computer-Assisted/methods
4.
Magn Reson Med ; 90(5): 2052-2070, 2023 11.
Article in English | MEDLINE | ID: mdl-37427449

ABSTRACT

PURPOSE: To develop a method for building MRI reconstruction neural networks robust to changes in signal-to-noise ratio (SNR) and trainable with a limited number of fully sampled scans. METHODS: We propose Noise2Recon, a consistency training method for SNR-robust accelerated MRI reconstruction that can use both fully sampled (labeled) and undersampled (unlabeled) scans. Noise2Recon uses unlabeled data by enforcing consistency between model reconstructions of undersampled scans and their noise-augmented counterparts. Noise2Recon was compared to compressed sensing and both supervised and self-supervised deep learning baselines. Experiments were conducted using retrospectively accelerated data from the mridata three-dimensional fast-spin-echo knee and two-dimensional fastMRI brain datasets. All methods were evaluated in label-limited settings and among out-of-distribution (OOD) shifts, including changes in SNR, acceleration factors, and datasets. An extensive ablation study was conducted to characterize the sensitivity of Noise2Recon to hyperparameter choices. RESULTS: In label-limited settings, Noise2Recon achieved better structural similarity, peak signal-to-noise ratio, and normalized-RMS error than all baselines and matched performance of supervised models, which were trained with 14 × $$ 14\times $$ more fully sampled scans. Noise2Recon outperformed all baselines, including state-of-the-art fine-tuning and augmentation techniques, among low-SNR scans and when generalizing to OOD acceleration factors. Augmentation extent and loss weighting hyperparameters had negligible impact on Noise2Recon compared to supervised methods, which may indicate increased training stability. CONCLUSION: Noise2Recon is a label-efficient reconstruction method that is robust to distribution shifts, such as changes in SNR, acceleration factors, and others, with limited or no fully sampled training data.


Subject(s)
Deep Learning , Image Processing, Computer-Assisted , Humans , Image Processing, Computer-Assisted/methods , Signal-To-Noise Ratio , Retrospective Studies , Magnetic Resonance Imaging/methods , Supervised Machine Learning
5.
Bioengineering (Basel) ; 10(2)2023 Feb 04.
Article in English | MEDLINE | ID: mdl-36829701

ABSTRACT

We systematically evaluate the training methodology and efficacy of two inpainting-based pretext tasks of context prediction and context restoration for medical image segmentation using self-supervised learning (SSL). Multiple versions of self-supervised U-Net models were trained to segment MRI and CT datasets, each using a different combination of design choices and pretext tasks to determine the effect of these design choices on segmentation performance. The optimal design choices were used to train SSL models that were then compared with baseline supervised models for computing clinically-relevant metrics in label-limited scenarios. We observed that SSL pretraining with context restoration using 32 × 32 patches and Poission-disc sampling, transferring only the pretrained encoder weights, and fine-tuning immediately with an initial learning rate of 1 × 10-3 provided the most benefit over supervised learning for MRI and CT tissue segmentation accuracy (p < 0.001). For both datasets and most label-limited scenarios, scaling the size of unlabeled pretraining data resulted in improved segmentation performance. SSL models pretrained with this amount of data outperformed baseline supervised models in the computation of clinically-relevant metrics, especially when the performance of supervised learning was low. Our results demonstrate that SSL pretraining using inpainting-based pretext tasks can help increase the robustness of models in label-limited scenarios and reduce worst-case errors that occur with supervised learning.

6.
J Magn Reson Imaging ; 57(4): 1029-1039, 2023 04.
Article in English | MEDLINE | ID: mdl-35852498

ABSTRACT

BACKGROUND: Deep learning (DL)-based automatic segmentation models can expedite manual segmentation yet require resource-intensive fine-tuning before deployment on new datasets. The generalizability of DL methods to new datasets without fine-tuning is not well characterized. PURPOSE: Evaluate the generalizability of DL-based models by deploying pretrained models on independent datasets varying by MR scanner, acquisition parameters, and subject population. STUDY TYPE: Retrospective based on prospectively acquired data. POPULATION: Overall test dataset: 59 subjects (26 females); Study 1: 5 healthy subjects (zero females), Study 2: 8 healthy subjects (eight females), Study 3: 10 subjects with osteoarthritis (eight females), Study 4: 36 subjects with various knee pathology (10 females). FIELD STRENGTH/SEQUENCE: A 3-T, quantitative double-echo steady state (qDESS). ASSESSMENT: Four annotators manually segmented knee cartilage. Each reader segmented one of four qDESS datasets in the test dataset. Two DL models, one trained on qDESS data and another on Osteoarthritis Initiative (OAI)-DESS data, were assessed. Manual and automatic segmentations were compared by quantifying variations in segmentation accuracy, volume, and T2 relaxation times for superficial and deep cartilage. STATISTICAL TESTS: Dice similarity coefficient (DSC) for segmentation accuracy. Lin's concordance correlation coefficient (CCC), Wilcoxon rank-sum tests, root-mean-squared error-coefficient-of-variation to quantify manual vs. automatic T2 and volume variations. Bland-Altman plots for manual vs. automatic T2 agreement. A P value < 0.05 was considered statistically significant. RESULTS: DSCs for the qDESS-trained model, 0.79-0.93, were higher than those for the OAI-DESS-trained model, 0.59-0.79. T2 and volume CCCs for the qDESS-trained model, 0.75-0.98 and 0.47-0.95, were higher than respective CCCs for the OAI-DESS-trained model, 0.35-0.90 and 0.13-0.84. Bland-Altman 95% limits of agreement for superficial and deep cartilage T2 were lower for the qDESS-trained model, ±2.4 msec and ±4.0 msec, than the OAI-DESS-trained model, ±4.4 msec and ±5.2 msec. DATA CONCLUSION: The qDESS-trained model may generalize well to independent qDESS datasets regardless of MR scanner, acquisition parameters, and subject population. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.


Subject(s)
Cartilage, Articular , Deep Learning , Osteoarthritis, Knee , Female , Humans , Retrospective Studies , Cartilage, Articular/pathology , Magnetic Resonance Imaging/methods , Algorithms , Osteoarthritis, Knee/pathology
7.
Magn Reson Med ; 89(2): 577-593, 2023 02.
Article in English | MEDLINE | ID: mdl-36161727

ABSTRACT

PURPOSE: To develop and validate a method for B 0 $$ {B}_0 $$ mapping for knee imaging using the quantitative Double-Echo in Steady-State (qDESS) exploiting the phase difference ( Δ Î¸ $$ \Delta \theta $$ ) between the two echoes acquired. Contrary to a two-gradient-echo (2-GRE) method, Δ Î¸ $$ \Delta \theta $$ depends only on the first echo time. METHODS: Bloch simulations were applied to investigate robustness to noise of the proposed methodology and all imaging studies were validated with phantoms and in vivo simultaneous bilateral knee acquisitions. Two phantoms and five healthy subjects were scanned using qDESS, water saturation shift referencing (WASSR), and multi-GRE sequences. Δ B 0 $$ \Delta {B}_0 $$ maps were calculated with the qDESS and the 2-GRE methods and compared against those obtained with WASSR. The comparison was quantitatively assessed exploiting pixel-wise difference maps, Bland-Altman (BA) analysis, and Lin's concordance coefficient ( ρ c $$ {\rho}_c $$ ). For in vivo subjects, the comparison was assessed in cartilage using average values in six subregions. RESULTS: The proposed method for measuring Δ B 0 $$ \Delta {B}_0 $$ inhomogeneities from a qDESS acquisition provided Δ B 0 $$ \Delta {B}_0 $$ maps that were in good agreement with those obtained using WASSR. Δ B 0 $$ \Delta {B}_0 $$ ρ c $$ {\rho}_c $$ values were ≥ $$ \ge $$ 0.98 and 0.90 in phantoms and in vivo, respectively. The agreement between qDESS and WASSR was comparable to that of a 2-GRE method. CONCLUSION: The proposed method may allow B0 correction for qDESS T 2 $$ {T}_2 $$ mapping using an inherently co-registered Δ B 0 $$ \Delta {B}_0 $$ map without requiring an additional B0 measurement sequence. More generally, the method may help shorten knee imaging protocols that require an auxiliary Δ B 0 $$ \Delta {B}_0 $$ map by exploiting a qDESS acquisition that also provides T 2 $$ {T}_2 $$ measurements and high-quality morphological imaging.


Subject(s)
Knee , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Knee/diagnostic imaging , Knee Joint/diagnostic imaging , Water
8.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Article in English | MEDLINE | ID: mdl-36583628

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Subject(s)
Breast Neoplasms , Diffusion Magnetic Resonance Imaging , Humans , Female , Prospective Studies , Prone Position , Diffusion Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging , Reproducibility of Results , Breast Neoplasms/diagnostic imaging , Echo-Planar Imaging/methods
9.
Magn Reson Med ; 88(5): 2139-2156, 2022 11.
Article in English | MEDLINE | ID: mdl-35906924

ABSTRACT

PURPOSE: Diffusion weighted Fast Spin Echo (DW-FSE) is a promising approach for distortionless DW imaging that is robust to system imperfections such as eddy currents and off-resonance. Due to non-Carr-Purcell-Meiboom-Gill (CPMG) magnetization, most DW-FSE sequences discard a large fraction of the signal ( 2 - 2 × $$ \sqrt{2}-2\times $$ ), reducing signal-to-noise ratio (SNR) efficiency compared to DW-EPI. The full FSE signal can be preserved by quadratically incrementing the transmit phase of the refocusing pulses, but this method of resolving non-CPMG magnetization has only been applied to single-shot DW-FSE due to challenges associated with image reconstruction. We present a joint linear reconstruction for multishot quadratic phase increment data that addresses these challenges and corrects ghosting from both shot-to-shot phase and intrashot signal oscillations. Multishot imaging reduces T2 blur and joint reconstruction of shots improves g-factor performance. A thorough analysis on the condition number of the proposed linear system is described. METHODS: A joint multishot reconstruction is derived from the non-CPMG signal model. Multishot quadratic phase increment DW-FSE was tested in a standardized diffusion phantom and compared to single-shot DW-FSE and DW-EPI in vivo in the brain, cervical spine, and prostate. The pseudo multiple replica technique was applied to generate g-factor and SNR maps. RESULTS: The proposed joint shot reconstruction eliminates ghosting from shot-to-shot phase and intrashot oscillations. g-factor performance is improved compared to previously proposed reconstructions, permitting efficient multishot imaging. apparent diffusion coefficient estimates in phantom experiments and in vivo are comparable to those obtained with conventional methods. CONCLUSION: Multi-shot non-CPMG DW-FSE data with full signal can be jointly reconstructed using a linear model.


Subject(s)
Diffusion Magnetic Resonance Imaging , Gills , Animals , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Male , Phantoms, Imaging , Signal-To-Noise Ratio
10.
Magn Reson Med ; 87(6): 2650-2666, 2022 06.
Article in English | MEDLINE | ID: mdl-35014729

ABSTRACT

PURPOSE: DWI near metal implants has not been widely explored due to substantial challenges associated with through-slice and in-plane distortions, the increased encoding requirement of different spectral bins, and limited SNR. There is no widely adopted clinical protocol for DWI near metal since the commonly used EPI trajectory fails completely due to distortion from extreme off-resonance ranging from 2 to 20 kHz. We present a sequence that achieves DWI near metal with moderate b-values (400-500 s/mm2 ) and volumetric coverage in clinically feasible scan times. THEORY AND METHODS: Multispectral excitation with Cartesian sampling, view angle tilting, and kz phase encoding reduce in-plane and through-plane off-resonance artifacts, and Carr-Purcell-Meiboom-Gill (CPMG) spin-echo refocusing trains counteract T2* effects. The effect of random phase on the refocusing train is eliminated using a stimulated echo diffusion preparation. Root-flipped Shinnar-Le Roux refocusing pulses permits preparation of a high spectral bandwidth, which improves imaging times by reducing the number of excitations required to cover the desired spectral range. B1 sensitivity is reduced by using an excitation that satisfies the CPMG condition in the preparation. A method for ADC quantification insensitive to background gradients is presented. RESULTS: Non-linear phase refocusing pulses reduces the peak B1 by 46% which allows RF bandwidth to be doubled. Simulations and phantom experiments show that a non-linear phase CPMG pulse pair reduces B1 sensitivity. Application in vivo demonstrates complementary contrast to conventional multispectral acquisitions and improved visualization compared to DW-EPI. CONCLUSION: Volumetric and multispectral DW imaging near metal can be achieved with a 3D encoded sequence.


Subject(s)
Artifacts , Gills , Animals , Diffusion Magnetic Resonance Imaging/methods , Phantoms, Imaging , Prostheses and Implants
11.
NMR Biomed ; 35(4): e4670, 2022 04.
Article in English | MEDLINE | ID: mdl-35088466

ABSTRACT

Magnetic resonance fingerprinting (MRF) is a rapidly developing approach for fast quantitative MRI. A typical drawback of dictionary-based MRF is an explosion of the dictionary size as a function of the number of reconstructed parameters, according to the "curse of dimensionality", which determines an explosion of resource requirements. Neural networks (NNs) have been proposed as a feasible alternative, but this approach is still in its infancy. In this work, we design a deep learning approach to MRF using a fully connected network (FCN). In the first part we investigate, by means of simulations, how the NN performance scales with the number of parameters to be retrieved in comparison with the standard dictionary approach. Four MRF sequences were considered: IR-FISP, bSSFP, IR-FISP-B1 , and IR-bSSFP-B1 , the latter two designed to be more specific for B1+ parameter encoding. Estimation accuracy, memory usage, and computational time required to perform the estimation task were considered to compare the scalability capabilities of the dictionary-based and the NN approaches. In the second part we study optimal training procedures by including different data augmentation and preprocessing strategies during training to achieve better accuracy and robustness to noise and undersampling artifacts. The study is conducted using the IR-FISP MRF sequence exploiting both simulations and in vivo acquisitions. Results demonstrate that the NN approach outperforms the dictionary-based approach in terms of scalability capabilities. Results also allow us to heuristically determine the optimal training strategy to make an FCN able to predict T1 , T2 , and M0 maps that are in good agreement with those obtained with the original dictionary approach. k-SVD denoising is proposed and found to be critical as a preprocessing step to handle undersampled data.


Subject(s)
Deep Learning , Algorithms , Brain , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Phantoms, Imaging
12.
Skeletal Radiol ; 51(3): 549-556, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34223946

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of a conventional metal artifact suppression sequence MAVRIC-SL (multi-acquisition variable-resonance image combination selective) and a novel 2.6-fold faster sequence employing robust principal component analysis (RPCA), in the MR evaluation of hip implants at 3 T. MATERIALS AND METHODS: Thirty-six total hip implants in 25 patients were scanned at 3 T using a conventional MAVRIC-SL proton density-weighted sequence and an RPCA MAVRIC-SL proton density-weighted sequence. Comparison was made of image quality, geometric distortion, visualization around acetabular and femoral components, and conspicuity of abnormal imaging findings using the Wilcoxon signed-rank test and a non-inferiority test. Abnormal findings were correlated with subsequent clinical management and intraoperative findings if the patient underwent subsequent surgery. RESULTS: Mean scores for conventional MAVRIC-SL were better than RPCA MAVRIC-SL for all qualitative parameters (p < 0.05), although the probability of RPCA MAVRIC-SL being clinically useful was non-inferior to conventional MAVRIC-SL (within our accepted 10% difference, p < 0.05), except for visualization around the acetabular component. Abnormal imaging findings were seen in 25 hips, and either equally visible or visible but less conspicuous on RPCA MAVRIC-SL in 21 out of 25 cases. In 4 cases, a small joint effusion was queried on MAVRIC-SL but not RPCA MAVRIC-SL, but the presence or absence of a small effusion did not affect subsequent clinical management and patient outcome. CONCLUSION: While the overall image quality is reduced, RPCA MAVRIC-SL allows for significantly reduced scan time and maintains almost equal diagnostic performance.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Artifacts , Humans , Magnetic Resonance Imaging , Prostheses and Implants
13.
Med Phys ; 48(10): 6069-6079, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34287972

ABSTRACT

PURPOSE: Almost one in four lumpectomies fails to fully remove cancerous tissue from the breast, requiring reoperation. This high failure rate suggests that existing lumpectomy guidance methods are inadequate for allowing surgeons to consistently identify the proper volume of tissue for excision. Current guidance techniques either provide little information about the tumor position or require surgeons to frequently switch between making incisions and manually probing for a marker placed at the lesion site. This article explores the feasibility of thermo-acoustic ultrasound (TAUS) to enable hands-free localization of metallic biopsy markers throughout surgery, which would allow for continuous visualization of the lesion site in the breast without the interruption of surgery. In a TAUS-based localization system, microwave excitations would be transmitted into the breast, and the amplification in microwave absorption around the metallic markers would generate acoustic signals from the marker sites through the thermo-acoustic effect. Detection and ranging of these signals by multiple acoustic receivers on the breast could then enable marker localization through acoustic multilateration. METHODS: Physics simulations were used to characterize the TAUS signals generated from different markers by microwave excitations. First, electromagnetic simulations determined the spatial pattern of the amplification in microwave absorption around the markers. Then, acoustic simulations characterized the acoustic fields generated from these markers at various acoustic frequencies. TAUS-based one-dimensional (1D) ranging of two metallic markers-including a biopsy marker that is FDA-approved for clinical use-immersed in saline was also performed using a bench-top setup. To perform TAUS acquisitions, a microwave applicator was driven by 2.66 GHz microwave signals that were amplitude-modulated by chirps at the desired acoustic excitation frequencies, and the resulting TAUS signal from the markers was detected by an ultrasonic transducer. RESULTS: The simulation results show that the geometry of the marker strongly impacts the quantity and spatial pattern of both the microwave absorption around the marker and the resulting TAUS signal generated from the marker. The simulated TAUS signal maps and acoustic frequency responses also make clear that the marker geometry plays an important role in determining the overall system response. Using the bench-top setup, TAUS detection and 1D localization of the markers were successfully demonstrated for multiple different combinations of microwave applicator and metallic marker. These initial results indicate that TAUS-based localization of biopsy markers is feasible. CONCLUSIONS: Through microwave excitations and acoustic detection, TAUS can be used to localize metallic biopsy markers. With further development, TAUS opens new avenues to enable a more intuitive lumpectomy guidance system that could help to achieve better lumpectomy outcomes.


Subject(s)
Breast Neoplasms , Mastectomy, Segmental , Acoustics , Biopsy , Breast , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Female , Humans , Ultrasonography
14.
Radiol Artif Intell ; 3(3): e200078, 2021 May.
Article in English | MEDLINE | ID: mdl-34235438

ABSTRACT

PURPOSE: To organize a multi-institute knee MRI segmentation challenge for characterizing the semantic and clinical efficacy of automatic segmentation methods relevant for monitoring osteoarthritis progression. MATERIALS AND METHODS: A dataset partition consisting of three-dimensional knee MRI from 88 retrospective patients at two time points (baseline and 1-year follow-up) with ground truth articular (femoral, tibial, and patellar) cartilage and meniscus segmentations was standardized. Challenge submissions and a majority-vote ensemble were evaluated against ground truth segmentations using Dice score, average symmetric surface distance, volumetric overlap error, and coefficient of variation on a holdout test set. Similarities in automated segmentations were measured using pairwise Dice coefficient correlations. Articular cartilage thickness was computed longitudinally and with scans. Correlation between thickness error and segmentation metrics was measured using the Pearson correlation coefficient. Two empirical upper bounds for ensemble performance were computed using combinations of model outputs that consolidated true positives and true negatives. RESULTS: Six teams (T 1-T 6) submitted entries for the challenge. No differences were observed across any segmentation metrics for any tissues (P = .99) among the four top-performing networks (T 2, T 3, T 4, T 6). Dice coefficient correlations between network pairs were high (> 0.85). Per-scan thickness errors were negligible among networks T 1-T 4 (P = .99), and longitudinal changes showed minimal bias (< 0.03 mm). Low correlations (ρ < 0.41) were observed between segmentation metrics and thickness error. The majority-vote ensemble was comparable to top-performing networks (P = .99). Empirical upper-bound performances were similar for both combinations (P = .99). CONCLUSION: Diverse networks learned to segment the knee similarly, where high segmentation accuracy did not correlate with cartilage thickness accuracy and voting ensembles did not exceed individual network performance.See also the commentary by Elhalawani and Mak in this issue.Keywords: Cartilage, Knee, MR-Imaging, Segmentation © RSNA, 2020Supplemental material is available for this article.

15.
Pediatr Radiol ; 51(13): 2549-2560, 2021 12.
Article in English | MEDLINE | ID: mdl-34156504

ABSTRACT

BACKGROUND: Projection radiography (XR) is often supplemented by both CT (to evaluate osseous structures with ionizing radiation) and MRI (for marrow and soft-tissue assessment). Zero echo time (ZTE) MR imaging produces a "CT-like" osseous contrast that might obviate CT. OBJECTIVE: This study investigated our institution's initial experience in implementing an isotropic ZTE MR imaging sequence for pediatric musculoskeletal examinations. MATERIALS AND METHODS: Pediatric patients referred for extremity MRI at 3 tesla (T) underwent ZTE MR imaging to yield images with contrast similar to that of CT. A radiograph-like image was also created with ray-sum image processing. We assessed ZTE-CT/XR anatomical image quality (Sanat) from 0 (nondiagnostic) to 5 (outstanding). Further, we made image comparisons on a 5-point scale (Scomp) (range of -2 = conventional CT/XR greater anatomical delineation to +2 = ZTE-CT/XR greater anatomical delineation; 0=same) for three cohorts: (1) ZTE-XR to conventional radiography, (2) ZTE-CT to conventional CT and (3) pathological lesion assessment on ZTE-XR to conventional radiography. We measured cortical thickness of ZTE-XR and ZTE-CT and compared these with conventional imaging. We calculated confidence interval of proportions, Wilcoxon rank sum test and intraclass correlation coefficients for inter-reader agreement. RESULTS: Cohorts 1, 2 and 3 consisted of 40, 20 and 35 cases, respectively (age range 0.6-23.0 years). ZTE-CT versus CT and ZTE-XR versus radiography of cortical thicknesses were not significantly different (P=0.55 and P=0.31, respectively). Cortical delineation was rated diagnostic or better (score of 3, 4 or 5) in all cases (confidence interval of proportions = 100%) for ZTE-CT/XR. Similarly, intramedullary cavity delineation was rated diagnostic or better in all cases for ZTE-CT, and ZTE-XR was at least diagnostic in 58-63% of cases. For cohort 2, cortex and intramedullary cavity Scomp for ZTE-CT was comparable to those of conventional CT, with confidence interval of proportion (sum of score of -1 to +2) of 93-100% and 95%, respectively. Pathology visualized on ZTE-CT/XR was comparable; Scomp confidence interval of proportions was 95%/97-100%, with improved delineation of non-displaced fractures on ZTE-XR. Readers had moderate to near-perfect intraclass correlation coefficient (range=0.60-0.93). CONCLUSION: Implementation of a diagnostic-quality ZTE MRI sequence in the pediatric population is feasible and can be performed as a complementary pulse sequence to enhance musculoskeletal MRI studies. Compared to conventional CT, ZTE has comparable cortical delineation, intramedullary cavity and pathology visualization. While not intended as a replacement for conventional radiography, ZTE-XR provides similar visualization of pathology.


Subject(s)
Magnetic Resonance Imaging , Musculoskeletal System , Adolescent , Adult , Child , Child, Preschool , Cohort Studies , Humans , Image Processing, Computer-Assisted , Infant , Magnetic Resonance Spectroscopy , Musculoskeletal System/diagnostic imaging , Young Adult
16.
Eur Radiol ; 31(12): 9369-9379, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33993332

ABSTRACT

OBJECTIVES: To determine whether synovitis graded by radiologists using hybrid quantitative double-echo in steady-state (qDESS) images can be utilized as a non-contrast approach to assess synovitis in the knee, compared against the reference standard of contrast-enhanced MRI (CE-MRI). METHODS: Twenty-two knees (11 subjects) with moderate to severe osteoarthritis (OA) were scanned using CE-MRI, qDESS with a high diffusion weighting (qDESSHigh), and qDESS with a low diffusion weighting (qDESSLow). Four radiologists graded the overall impression of synovitis, their diagnostic confidence, and regional grading of synovitis severity at four sites (suprapatellar pouch, intercondylar notch, and medial and lateral peripatellar recesses) in the knee using a 4-point scale. Agreement between CE-MRI and qDESS, inter-rater agreement, and intra-rater agreement were assessed using a linearly weighted Gwet's AC2. RESULTS: Good agreement was seen between CE-MRI and both qDESSLow (AC2 = 0.74) and qDESSHigh (AC2 = 0.66) for the overall impression of synovitis, but both qDESS sequences tended to underestimate the severity of synovitis compared to CE-MRI. Good inter-rater agreement was seen for both qDESS sequences (AC2 = 0.74 for qDESSLow, AC2 = 0.64 for qDESSHigh), and good intra-rater agreement was seen for both sequences as well (qDESSLow AC2 = 0.78, qDESSHigh AC2 = 0.80). Diagnostic confidence was moderate to high for qDESSLow (mean = 2.36) and slightly less than moderate for qDESSHigh (mean = 1.86), compared to mostly high confidence for CE-MRI (mean = 2.73). CONCLUSIONS: qDESS shows potential as an alternative MRI technique for assessing the severity of synovitis without the use of a gadolinium-based contrast agent. KEY POINTS: The use of the quantitative double-echo in steady-state (qDESS) sequence for synovitis assessment does not require the use of a gadolinium-based contrast agent. Preliminary results found that low diffusion-weighted qDESS (qDESSLow) shows good agreement to contrast-enhanced MRI for characterization of the severity of synovitis, with a relative bias towards underestimation of severity. Preliminary results also found that qDESSLow shows good inter- and intra-rater agreement for the depiction of synovitis, particularly for readers experienced with the sequence.


Subject(s)
Osteoarthritis, Knee , Synovitis , Contrast Media , Humans , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging , Osteoarthritis, Knee/diagnostic imaging , Synovial Membrane , Synovitis/diagnostic imaging
17.
Front Neurol ; 12: 608549, 2021.
Article in English | MEDLINE | ID: mdl-33658976

ABSTRACT

Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases.

18.
Arthritis Res Ther ; 23(1): 55, 2021 02 13.
Article in English | MEDLINE | ID: mdl-33581741

ABSTRACT

BACKGROUND: To assess diagnostic accuracy of quantitative double-echo in steady-state (qDESS) MRI for detecting synovitis in knee osteoarthritis (OA). METHODS: Patients with different degrees of radiographic knee OA were included prospectively. All underwent MRI with both qDESS and contrast-enhanced T1-weighted magnetic resonance imaging (CE-MRI). A linear combination of the two qDESS images can be used to create an image that displays contrast between synovium and the synovial fluid. Synovitis on both qDESS and CE-MRI was assessed semi-quantitatively, using a whole-knee synovitis sum score, indicating no/equivocal, mild, moderate, and severe synovitis. The correlation between sum scores of qDESS and CE-MRI (reference standard) was determined using Spearman's rank correlation coefficient and intraclass correlation coefficient for absolute agreement. Receiver operating characteristic analysis was performed to assess the diagnostic performance of qDESS for detecting different degrees of synovitis, with CE-MRI as reference standard. RESULTS: In the 31 patients included, very strong correlation was found between synovitis sum scores on qDESS and CE-MRI (ρ = 0.96, p < 0.001), with high absolute agreement (0.84 (95%CI 0.14-0.95)). Mean sum score (SD) values on qDESS 5.16 (3.75) were lower than on CE-MRI 7.13 (4.66), indicating systematically underestimated synovitis severity on qDESS. For detecting mild synovitis or higher, high sensitivity and specificity were found for qDESS (1.00 (95%CI 0.80-1.00) and 0.909 (0.571-1.00), respectively). For detecting moderate synovitis or higher, sensitivity and specificity were good (0.727 (95%CI 0.393-0.927) and 1.00 (0.800-1.00), respectively). CONCLUSION: qDESS MRI is able to, however with an underestimation, detect synovitis in patients with knee OA.


Subject(s)
Osteoarthritis, Knee , Synovitis , Humans , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging , Osteoarthritis, Knee/diagnostic imaging , Synovial Fluid , Synovial Membrane , Synovitis/diagnostic imaging
19.
J Orthop Res ; 39(11): 2340-2352, 2021 11.
Article in English | MEDLINE | ID: mdl-33483997

ABSTRACT

Cartilage transmits and redistributes biomechanical loads in the knee joint during exercise. Exercise-induced loading alters cartilage hydration and is detectable using quantitative magnetic resonance imaging (MRI), where T2 relaxation time (T2 ) is influenced by cartilage collagen composition, fiber orientation, and changes in the extracellular matrix. This study characterized short-term transient responses of healthy knee cartilage to running-induced loading using bilateral scans and image registration. Eleven healthy female recreational runners (33.73 ± 4.22 years) and four healthy female controls (27.25 ± 1.38 years) were scanned on a 3T GE MRI scanner with quantitative 3D double-echo in steady-state before running over-ground (runner group) or resting (control group) for 40 min. Subjects were scanned immediately post-activity at 5-min intervals for 60 min. T2 times were calculated for femoral, tibial, and patellar cartilage at each time point and analyzed using a mixed-effects model and Bonferroni post hoc. There were immediate decreases in T2 (mean ± SEM) post-run in superficial femoral cartilage of at least 3.3% ± 0.3% (p = .002) between baseline and Time 0 that remained for 25 min, a decrease in superficial tibial cartilage T2 of 2.9% ± 0.4% (p = .041) between baseline and Time 0, and a decrease in superficial patellar cartilage T2 of 3.6% ± 0.3% (p = .020) 15 min post-run. There were decreases in the medial posterior region of superficial femoral cartilage T2 of at least 5.3 ± 0.2% (p = .022) within 5 min post-run that remained at 60 min post-run. These results increase understanding of transient responses of healthy cartilage to repetitive, exercise-induced loading and establish preliminary recommendations for future definitive studies of cartilage response to running.


Subject(s)
Cartilage, Articular , Running , Cartilage, Articular/pathology , Female , Humans , Knee , Knee Joint/physiology , Magnetic Resonance Imaging/methods , Patella , Running/physiology
20.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Article in English | MEDLINE | ID: mdl-33382171

ABSTRACT

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Breast Neoplasms , Diffusion Magnetic Resonance Imaging , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Echo-Planar Imaging , Female , Humans , Magnetic Resonance Imaging , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...