Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Discov Nano ; 18(1): 25, 2023 02 27.
Article in English | MEDLINE | ID: mdl-36847870

ABSTRACT

Piezoelectric microelectromechanical system (piezo-MEMS)-based mass sensors including the piezoelectric microcantilevers, surface acoustic waves (SAW), quartz crystal microbalance (QCM), piezoelectric micromachined ultrasonic transducer (PMUT), and film bulk acoustic wave resonators (FBAR) are highlighted as suitable candidates for highly sensitive gas detection application. This paper presents the piezo-MEMS gas sensors' characteristics such as their miniaturized structure, the capability of integration with readout circuit, and fabrication feasibility using multiuser technologies. The development of the piezoelectric MEMS gas sensors is investigated for the application of low-level concentration gas molecules detection. In this work, the various types of gas sensors based on piezoelectricity are investigated extensively including their operating principle, besides their material parameters as well as the critical design parameters, the device structures, and their sensing materials including the polymers, carbon, metal-organic framework, and graphene.

2.
Materials (Basel) ; 15(3)2022 Feb 05.
Article in English | MEDLINE | ID: mdl-35161148

ABSTRACT

Resistive random access memory (RRAM) has two distinct processes, the SET and RESET processes, that control the formation and dissolution of conductive filament, respectively. The laws of thermodynamics state that these processes correspond to the lowest possible level of free energy. In an RRAM device, a high operating voltage causes device degradation, such as bends, cracks, or bubble-like patterns. In this work, we developed a statistical simulation of the switching mechanism in a ZnO-based RRAM. The model used field-driven ion migration and temperature effects to design a ZnO-based RRAM dynamic SET and RESET resistance transition process. We observed that heat transport within the conducting filament generated a great deal of heat energy due to the carrier transport of the constituent dielectric material. The model was implemented using the built-in COMSOL Multiphysics software to address heat transfer, electrostatic, and yield RRAM energy. The heat energy increased with the increase in the operating power. Hence, the reliability of a device with high power consumption cannot be assured. We obtained various carrier heat analyses in 2D images and concluded that developing RRAM devices with low operating currents through material and structure optimization is crucial.

3.
Foods ; 10(10)2021 Oct 11.
Article in English | MEDLINE | ID: mdl-34681455

ABSTRACT

Adulteration of meat products is a delicate issue for people around the globe. The mixing of lard in meat causes a significant problem for end users who are sensitive to halal meat consumption. Due to the highly similar lipid profiles of meat species, the identification of adulteration becomes more difficult. Therefore, a comprehensive spectral detailing of meat species is required, which can boost the adulteration detection process. The experiment was conducted by distributing samples labeled as "Pure (80 samples)" and "Adulterated (90 samples)". Lard was mixed with the ratio of 10-50% v/v with beef, lamb, and chicken samples to obtain adulterated samples. Functional groups were discovered for pure pork, and two regions of difference (RoD) at wavenumbers 1700-1800 cm-1 and 2800-3000 cm-1 were identified using absorbance values from the FTIR spectrum for all samples. The principal component analysis (PCA) described the studied adulteration using three principal components with an explained variance of 97.31%. The multiclass support vector machine (M-SVM) was trained to identify the sample class values as pure and adulterated clusters. The acquired overall classification accuracy for a cluster of pure samples was 81.25%, whereas when the adulteration ratio was above 10%, 71.21% overall accuracy was achieved for a group of adulterated samples. Beef and lamb samples for both adulterated and pure classes had the highest classification accuracy value of 85%, whereas chicken had the lowest value of 78% for each category. This paper introduces a comprehensive spectrum analysis for pure and adulterated samples of beef, chicken, lamb, and lard. Moreover, we present a rapid M-SVM model for an accurate classification of lard adulteration in different samples despite its low-level presence.

4.
Nanoscale Res Lett ; 16(1): 16, 2021 Jan 26.
Article in English | MEDLINE | ID: mdl-33496852

ABSTRACT

Over the last couple of decades, the advancement in Microelectromechanical System (MEMS) devices is highly demanded for integrating the economically miniaturized sensors with fabricating technology. A sensor is a system that detects and responds to multiple physical inputs and converting them into analogue or digital forms. The sensor transforms these variations into a form which can be utilized as a marker to monitor the device variable. MEMS exhibits excellent feasibility in miniaturization sensors due to its small dimension, low power consumption, superior performance, and, batch-fabrication. This article presents the recent developments in standard actuation and sensing mechanisms that can serve MEMS-based devices, which is expected to revolutionize almost many product categories in the current era. The featured principles of actuating, sensing mechanisms and real-life applications have also been discussed. Proper understanding of the actuating and sensing mechanisms for the MEMS-based devices can play a vital role in effective selection for novel and complex application design.

5.
Indian J Nephrol ; 26(4): 257-61, 2016.
Article in English | MEDLINE | ID: mdl-27512297

ABSTRACT

We conducted a prospective study to assess utility of detection of antibodies to phospholipase A2receptor (PLA2R) in the serum of patients with membranous nephropathy. Seventy five patients with biopsy proven membranous nephropathy admitted between January 2011 and September 2014 were studied. Serum anti- PLA2R was tested by indirect immunofluorescence. The test was positive in 45 out of 60 patients with primary membranous nephropathy (PMN) and in none of the 15 patients with secondary membranous nephropathy, with a sensitivity of 75% and specificity of 100% for PMN. Anti PLA2R positivity also showed a significant correlation with quantum of proteinuria and negative correlation with serum albumin. This study has validated detection of serum anti PLA2R in PMN as a non invasive diagnostic tool in Indian patients.

6.
Indian J Nephrol ; 26(2): 131-3, 2016.
Article in English | MEDLINE | ID: mdl-27051138

ABSTRACT

Angiomyolipomas (AML) of the kidney are non-encapsulated benign neoplasms with the incidence of 45-80% in patients with tuberous sclerosis and 1-3% in sporadic cases. There are very few case reports in the literature in which kidneys with AML have been used for transplantation. We report here a 27-year-old female patient who received a live related renal transplant from her mother with isolated angiomyolipoma in donor kidney and on follow-up after 5 years, has stable graft function and tumor size.

7.
Sensors (Basel) ; 11(8): 7892-907, 2011.
Article in English | MEDLINE | ID: mdl-22164052

ABSTRACT

This paper reports a low-cost, high-sensitivity CMOS-MEMS piezoresistive accelerometer with large proof mass. In the device fabricated using ON Semiconductor 0.5 µm CMOS technology, an inherent CMOS polysilicon thin film is utilized as the piezoresistive sensing material. A full Wheatstone bridge was constructed through easy wiring allowed by the three metal layers in the 0.5 µm CMOS technology. The device fabrication process consisted of a standard CMOS process for sensor configuration, and a deep reactive ion etching (DRIE) based post-CMOS microfabrication for MEMS structure release. A bulk single-crystal silicon (SCS) substrate is included in the proof mass to increase sensor sensitivity. In device design and analysis, the self heating of the polysilicon piezoresistors and its effect to the sensor performance is also discussed. With a low operating power of 1.5 mW, the accelerometer demonstrates a sensitivity of 0.077 mV/g prior to any amplification. Dynamic tests have been conducted with a high-end commercial calibrating accelerometer as reference.


Subject(s)
Micro-Electrical-Mechanical Systems , Semiconductors , Silicon/chemistry , Acceleration , Calibration , Computer Systems , Equipment Design , Hot Temperature , Microscopy, Electron, Scanning/methods , Models, Statistical , Sensitivity and Specificity , Software , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL