Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Pain Ther ; 12(5): 1221-1233, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37481774

ABSTRACT

INTRODUCTION: A novel closed-loop spinal cord stimulation (SCS) system has recently been approved for use which records evoked compound action potentials (ECAPs) from the spinal cord and utilizes these recordings to automatically adjust the stimulation strength in real time. It automatically compensates for fluctuations in distance between the epidural leads and the spinal cord by maintaining the neural response (ECAP) at a determined target level. This data collection was principally designed to evaluate the performance of this first closed-loop SCS system in a 'real-world' setting under normal conditions of use in a single European center. METHODS: In this prospective, single-center observational data collection, 22 patients were recruited at the outpatient pain clinic of the St. Antonius Hospital. All candidates were suffering from chronic pain in the trunk and/or limbs due to PSPS type 2 (persistent spinal pain syndrome). As standard of care, follow-up visits were completed at 3 months, 6 months, and 12 months post-device activation. Patient-reported outcome data (pain intensity, patient satisfaction) and electrophysiological and device data (ECAP amplitude, conduction velocity, current output, pulse width, frequency, usage), and patient interaction with their controller were collected at baseline and during standard of care follow-up visits. RESULTS: Significant decreases in pain intensity for overall back or leg pain scores (verbal numerical rating score = VNRS) were observed between baseline [mean ± SEM (standard error of the mean); n = 22; 8.4 ± 0.2)], 3 months (n = 12; 1.9 ± 0.5), 6 months (n = 16; 2.6 ± 0.5), and 12 months (n = 20; 2.0 ± 0.5), with 85.0% of the patients being satisfied at 12 months. Additionally, no significant differences in average pain relief at 3 months and 12 months between the real-world data (77.2%; 76.8%) and the AVALON (71.2%; 73.6%) and EVOKE (78.1%; 76.7%) studies were observed. CONCLUSIONS: These initial 'real-world' data on ECAP-controlled, closed-loop SCS in a real-world clinical setting appear to be promising, as they provide novel insights of the beneficial effect of ECAP-controlled, closed-loop SCS in a real-world setting. The presented results demonstrate a noteworthy maintenance of pain relief over 12 months and corroborate the outcomes observed in the AVALON prospective, multicenter, single-arm study and the EVOKE double-blind, multicenter, randomized controlled trial. TRIAL REGISTRATION: The data collection is registered on the International Clinical Trials Registry Platform (Trial NL7889).

2.
Neuromodulation ; 25(7): 1059-1063, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35562262

ABSTRACT

INTRODUCTION: After an interpretation trajectory, the Dutch Quality of Healthcare Institute recommended that for five indications, spinal cord stimulation, dorsal root ganglion stimulation, or occipital nerve stimulation, together referred to as neurostimulation, can be considered effective and be reimbursed in the Netherlands. These five indications are the well and largely studied, accepted neurostimulation indications in scientific literature. As an extension of this, all the scientific societies involved in the Netherlands were required to reach a consensus about the diagnosis and treatment of these five formulated indications to describe the place of neurostimulation within the treatment algorithm. This article describes the development process and content of the consensus paper. MATERIALS AND METHODS: A scientific committee, consisting of three anesthesiologists/pain physicians (one of whom acted as the working group's chair), a neurosurgeon, a neurologist, a rehabilitation physician, and three nurse practitioners, participated. A quality advisor of the Knowledge Institute of the Dutch Federation of Medical Specialists supported the committee. The committee participated on behalf of their various scientific and professional societies. Three sessions were organized during which the place of neurostimulation in the treatment algorithm of the five relevant indications was discussed extensively. A narrative literature review and experts' opinions formed the basis of decision-making in the process. RESULTS: For all five diagnoses, general and diagnosis-specific treatment requirements, conservative treatments, and minimally invasive treatments are listed. These treatments should be considered in the chronic pain management algorithm before eventually proceeding to neurostimulation. DISCUSSION/CONCLUSION: The content of this consensus view was discussed and compared with other literature on cost-effectiveness and the place in the algorithm of treating chronic pain. This Dutch consensus paper could ultimately contribute to the maintenance or expansion of neurostimulation and the reimbursement.


Subject(s)
Chronic Pain , Spinal Cord Stimulation , Chronic Pain/therapy , Consensus , Humans , Netherlands , Pain Management
3.
Int J Gynecol Cancer ; 29(1): 53-59, 2019 01.
Article in English | MEDLINE | ID: mdl-30640684

ABSTRACT

OBJECTIVE: To identify factors that affect successful adaptation of sentinel lymph node mapping and those that lead to unintended adipose-only sentinel lymph node identification. METHODS: Surgical and pathological data were prospectively collected on patients with endometrial cancer who underwent sentinel lymph node mapping with indocyanine green with or without pelvic and/or para-aortic lymph node dissection between November 2013 and April 2017. All mapping cases were performed with the robotic system. Adipose-only specimens were defined as a sentinel lymph node without a pathologically identified lymph node after ultrastaging. RESULTS: A total of 202 patients were included: 83% had endometrioid pathology, 12% serous, 3% carcinosarcoma, and 2% clear cell, with mixed pathology noted in 2%. The bilateral sentinel lymph node detection rate was 66%, and the rate of mapping at least a unilateral sentinel lymph node was 86%. Neither the bilateral nor the unilateral sentinel lymph node mapping rate changed with increased surgeon experience. The rate of adipose-only sentinel lymph node identification was more frequent when comparing the first 10 cases (37%), cases 11 - 30 (28%), and > 30 cases (9%) (P = 0.006). Body mass index > 30 kg/m2, uterine fibroids, The International Federation of Gynecology and Obstetrics (FIGO) grade, and histology were not found to have a statistically significant impact on either sentinel lymph node identification or adipose-only sentinel lymph node identification. Adipose-only sentinel lymph nodes were more likely with increased time from cervical injection to identification of the sentinel lymph node in the right hemipelvis. The median range was 28 min (14-73) for true sentinel lymph node identification vs 33 min (23-74) for adipose-only sentinel lymph node identification (P = 0.02). CONCLUSION: Patient and surgeon factors did not impact the identification of sentinel lymph nodes over time. Adipose-only sentinel lymph nodes were more frequently identified in the initial cases and represent a potential complication to adapting sentinel lymph node biopsy without lymphadenectomy. The increase in adipose-only sentinel lymph node identification that was associated with time from cervical injection may represent delayed or disrupted uptake of indocyanine green.


Subject(s)
Adipose Tissue/pathology , Algorithms , Endometrial Neoplasms/pathology , Indocyanine Green , Sentinel Lymph Node/pathology , Adenocarcinoma, Clear Cell/pathology , Adenocarcinoma, Clear Cell/surgery , Adipose Tissue/surgery , Adult , Aged , Aged, 80 and over , Carcinosarcoma/pathology , Carcinosarcoma/surgery , Coloring Agents , Cystadenocarcinoma, Serous/pathology , Cystadenocarcinoma, Serous/surgery , Endometrial Neoplasms/surgery , Female , Follow-Up Studies , Humans , Hysterectomy , Lymph Node Excision , Middle Aged , Prognosis , Prospective Studies , Retrospective Studies , Robotic Surgical Procedures , Sentinel Lymph Node/surgery
4.
Pain ; 155(11): 2426-31, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25180016

ABSTRACT

Painful diabetic neuropathy (PDN) is a peripheral neuropathic pain condition that is often difficult to relieve. Spinal cord stimulation (SCS) is a proven effective therapy for various types of mixed neuropathic conditions, yet effectiveness of SCS treatment for PDN is not well established. To our knowledge, ours is the first multicentre randomized controlled trial investigating the effectiveness of SCS in patients with PDN. Sixty patients with PDN in the lower extremities refractory to conventional medical therapy were enrolled and followed for 6 months. They were randomized 2:1 to best conventional medical practice with (SCS group) or without (control group) additional SCS therapy, and both groups were assessed at regular intervals. At each follow-up visit, the EuroQoL 5D, the short form McGill Pain Questionnaire (SF-MPQ) and a visual analogue scale (VAS, ranging 0-100) to measure pain intensity were recorded. The average VAS score for pain intensity was 73 in the SCS group and 67 in the control group at baseline. After 6 months of treatment, the average VAS score was significantly reduced to 31 in the SCS group (P<.001) and remained 67 (P=.97) in the control group. The SF-MPQ and EuroQoL 5D questionnaires also showed that patients in the SCS group, unlike those in the control group, experienced reduced pain and improved health and quality of life after 6 months of treatment. In patients with refractory painful diabetic neuropathy, spinal cord stimulation therapy significantly reduced pain and improved quality of life.


Subject(s)
Diabetic Neuropathies/therapy , Spinal Cord Stimulation/methods , Aged , Female , Humans , Male , Middle Aged , Pain Measurement , Treatment Outcome
5.
J Am Chem Soc ; 127(31): 10786-7, 2005 Aug 10.
Article in English | MEDLINE | ID: mdl-16076157

ABSTRACT

Stacked thin layers of silver alloy (AgPdCu) and MoCr layers on 10 x 15 cm2 glass substrates were patterned by microcontact wave printing and etching. Patterns of etch-resistant octadecanethiol self-assembled monolayers (SAMs) were wave printed with regular backplane stabilized PDMS stamps. Pattern development was achieved by etching both metal layers in a single step, employing a nitric acid-based etching bath. Trifluoroacetic acid and a nitrite salt were identified as essential bath components for a homogeneous etching process. Etch defects could be eliminated by the addition of a decanesulfonate, which stabilizes the SAM resist via a defect healing mechanism.

6.
Arch Insect Biochem Physiol ; 45(2): 47-59, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11093242

ABSTRACT

The utility of microplate and electrophoretic assays for detection of biochemical and physiological mechanisms underlying resistance to profenofos in the tobacco budworm, Heliothis virescens (F.), was assessed. Esterase (EST) activities were significantly higher in profenofos-resistant than -susceptible larvae, and activities were highly correlated (r(2) = 0.87) with resistance to profenofos. Both qualitative and quantitative variation was observed in electrophoretic gels stained with alpha- and beta-naphthyl acetates. Staining of ESTs was more intense with resistant larvae than those from a susceptible strain. In addition, a band (designated A') was expressed in larvae from profenofos-resistant strains, but not in larvae from an insecticide-susceptible strain. The frequency of expression of A' increased following selection with profenofos and was detected in 100% of the individuals from a profenofos-selected strain. The appearance of this band coincided with the decreased expression of a second band (designated A). A similar pattern (overexpression of A' and underexpression of A) also was observed in larvae from field-collected strains. Finally, reduction in the activity or the sensitivity of acetylcholinesterase to inhibition by chlorpyrifos oxon was observed in laboratory-selected and field-collected larvae that expressed resistance to profenofos. These results suggest that microplate and electrophoretic assays can be utilized as complementary tools for detecting and monitoring profenofos resistance in H. virescens.


Subject(s)
Esterases/metabolism , Insecticides/pharmacology , Lepidoptera/enzymology , Organothiophosphates/pharmacology , Acetylcholinesterase/metabolism , Animals , Chlorpyrifos/analogs & derivatives , Chlorpyrifos/pharmacology , Cholinesterase Inhibitors/pharmacology , Insecticide Resistance , Larva/enzymology
SELECTION OF CITATIONS