Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Talanta ; 99: 799-810, 2012 Sep 15.
Article in English | MEDLINE | ID: mdl-22967626

ABSTRACT

A commercial-off-the-shelf (COTS) ion trap mobility spectrometry (ITMS) based explosive trace detector (ETD) has been interfaced to a triple quadrupole mass spectrometer (MS/MS) for the purpose of characterizing the gas phase ion chemistry intrinsic to the ITMS instrument. The overall objective of the research is to develop a fundamental understanding of the gas phase ionization processes in the ITMS based ETD to facilitate the advancement of its operational effectiveness as well as guide the development of next generation ETDs. Product ion masses, daughter ion masses, and reduced mobility values measured by the ITMS/MS/MS configuration for a suite of nitro, nitrate, and peroxide containing explosives are reported. Molecular formulas, molecular structures, and ionization pathways for the various product ions are inferred using the mass and mobility data in conjunction with density functional theory. The predominant product ions are identified as follows: [TNT-H](-) for trinitrotoluene (TNT), [RDX+Cl](-) for cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), [NO(3)](-) for ethylene glycol dinitrate (EGDN), [NG+NO(3)](-) for nitroglycerine (NG), [PETN+NO(3)](-) for pentaerythritol tetranitrate (PETN), [HNO(3)+NO(3)](-) for ammonium nitrate (NH(4)NO(3)), [HMTD-NC(3)H(6)O(3)+H+Cl](-) for hexamethylene triperoxide diamine (HMTD), and [(CH(3))(2)CNH(2)](+) for triacetone triperoxide (TATP). The predominant ionization pathways for the formation of the various product ions are determined to include proton abstraction, ion-molecule attachment, autoionization, first-order and multi-order thermolysis, and nucleophilic substitution. The ion trapping scheme in the reaction region of the ITMS instrument is shown to increase predominant ion intensities relative to the secondary ion intensities when compared to non-ion trap operation.

2.
J Mass Spectrom ; 47(2): 201-7, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22359330

ABSTRACT

Methods and devices that use gas flows to collect ions and transfer them over long distances for mass spectrometric analysis have been developed. Gas flows derived from the ionization source itself or provided by means of additional pumping were used to generate a laminar flow inside cylindrical tube. Hydrodynamic simulations and experimental tests demonstrate that laminar flow can transfer ions over long distance. The typical angular discrimination effects encountered when sampling ions from ambient ionization sources are minimized, and the sampling of relatively large surface areas is demonstrated with desorption electrospray ionization (DESI). Ion transfer over 6 m has been achieved and its application to multiplexed chemical analysis is demonstrated on samples at locations remote from the mass spectrometer.


Subject(s)
Gases/chemistry , Spectrometry, Mass, Electrospray Ionization/instrumentation , Atmospheric Pressure , Computer Simulation , Equipment Design , Pharmaceutical Preparations/analysis , Spectrometry, Mass, Electrospray Ionization/methods
3.
Anal Chem ; 83(22): 8596-603, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-22017332

ABSTRACT

Hardware from a commercial-off-the-shelf (COTS) ion mobility spectrometry (IMS) based explosive trace detector (ETD) has been interfaced to an AB/SCIEX API 2000 triple quadrupole mass spectrometer. To interface the COTS IMS based ETD to the API 2000, the faraday plate of the IMS instrument and the curtain plate of the mass spectrometer were removed from their respective systems and replaced by a custom faraday plate, which was fabricated with a hole for passing the ion beam to the mass spectrometer, and a custom interface flange, which was designed to attach the IMS instrument onto the mass spectrometer. Additionally, the mass spectrometer was modified to increase the electric field strength and decrease the pressure in the differentially pumped interface, causing a decrease in the effect of collisional focusing and permitting a mobility spectrum to be measured using the mass spectrometer. The utility of the COTS-ETD/API 2000 configuration for the characterization of the gas phase ion chemistry of COTS-ETD equipment was established by obtaining mass and tandem mass spectra in the continuous ion flow and selected mobility monitoring operating modes and by obtaining mass-selected ion mobility spectra for the explosive standard 2,4,6 trinitrotoluene (TNT). This analysis confirmed that the product ion for TNT is [TNT - H](-), the predominant collision-induced dissociation pathway for [TNT- H](-) is the loss of NO and NO(2), and the reduced mobility value for [TNT - H](-) is 1.54 cm(2)V(-1) s(-1). Moreover, this analysis was attained for sample amounts of 1 ng and with a resolving power of 37. The objective of the research is to advance the operational effectiveness of COTS IMS based ETD equipment by developing a platform that can facilitate the understanding of the ion chemistry intrinsic to the equipment.


Subject(s)
Trinitrotoluene/analysis , Mass Spectrometry/instrumentation
4.
Anal Chem ; 83(3): 1084-92, 2011 Feb 01.
Article in English | MEDLINE | ID: mdl-21174437

ABSTRACT

Detection of explosives is important for public safety. A recently developed low-temperature plasma (LTP) probe for desorption and ionization of samples in the ambient environment ( Anal. Chem. 2008 , 80 , 9097 ) is applied in a comprehensive evaluation of analytical performance for rapid detection of 13 explosives and explosives-related compounds. The selected chemicals [pentaerythritol tetranitrate (PETN), trinitrotoluene (TNT), cyclo-1,3,5-trimethylenetrinitramine (RDX), tetryl, cyclo-1,3,5,7-tetramethylenetetranitrate (HMX), hexamethylene triperoxide diamine (HMTD), 2,4-dinitrotoluene, 1,3-dinitrobenzene, 1,3,5-trinitrobenzene, 2-amino-4,6-dinitrotoluene, 4-amino-2,6-dinitrotoluene, 2,6-dinitrotoluene, and 4-nitrotoluene) were tested at levels in the range 1 pg-10 ng. Most showed remarkable sensitivity in the negative-ion mode, yielding limits of detection in the low picogram range, particularly when analyzed from a glass substrate heated to 120 °C. Ions typically formed from these molecules (M) by LTP include [M + NO(2)](-), [M](-), and [M - NO(2)](-). The LTP-mass spectrometry methodology displayed a linear signal response over three orders of magnitude of analyte amount for the studied explosives. In addition, the effects of synthetic matrices and different types of surfaces were evaluated. The data obtained demonstrate that LTP-MS allows detection of ultratrace amounts of explosives and confirmation of their identity. Tandem mass spectrometry (MS/MS) was used to confirm the presence of selected explosives at low levels; for example, TNT was confirmed at absolute levels as low as 0.6 pg. Linearity and intra- and interday precision were also evaluated, yielding results that demonstrate the potential usefulness and ruggedness of LTP-MS for the detection of explosives of different classes. The use of ion/molecule reactions to form adducts with particular explosives such as RDX and HMX was shown to enhance the selectivity and specificity. This was accomplished by merging the discharge gas with an appropriate reagent headspace vapor (e.g., from a 0.2% trifluoracetic acid solution).


Subject(s)
Mass Spectrometry/methods , Mass Spectrometry/instrumentation , Temperature
5.
Analyst ; 135(5): 927-33, 2010 May.
Article in English | MEDLINE | ID: mdl-20419240

ABSTRACT

Low temperature plasma (LTP) ionization is an ambient plasma ionization method that permits the direct mass analysis of samples in their native atmospheric environment with little or no sample preparation. In this work, the low temperature plasma probe is used in the direct and rapid mass spectrometric analysis of aqueous phase samples including biofluids (saliva, urine, and hair extract). A detailed trace qualitative examination of 14 drugs of abuse has been performed. The relative standard deviation on average was approximately 16% for the LTP analysis of the drugs of abuse standards. Eleven of the fourteen drugs of abuse were detected in the low ng mL(-1) (3 pg absolute detection) to the mid microg mL(-1) (approximately 30 ng absolute detection) concentration range. One drug, cannabidiol, could not be detected until supplemental heating of the substrate was incorporated into the experimental protocol. The addition of supplemental heating improved the detection limits by at least an order of magnitude to approximately 0.5 ng mL(-1) to 0.5 microg mL(-1) (1.5 pg-1.5 ng absolute) for twelve of the fourteen drugs of abuse, so extending the linear dynamic range which for most analytes was four orders of magnitude. Quantitative capabilities were evaluated using the particular example of benzoylecgonine in urine by employing a deuterated internal standard. Matrix effects observed during the analysis of the drugs in complex biological fluids are also discussed. In addition, low temperature plasma ionization was applied to the examination of real (not spiked) biological samples and these results were confirmed using standard LC/MS methodology. The main advantages observed for this ambient desorption/ionization technique include the capabilities for direct analysis of liquid surfaces for in situ detection and the remarkable sensitivity in the examination of the drugs of abuse investigated here. The disadvantages of the method include the modest quantitative accuracy making LTP most useful as a rapid but semi-quantitative screening method.


Subject(s)
Chromatography, High Pressure Liquid/methods , Illicit Drugs/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Anesthetics, Local/urine , Caffeine/analysis , Caffeine/metabolism , Cocaine/analogs & derivatives , Cocaine/urine , Hair/chemistry , Illicit Drugs/urine , Reference Standards , Saliva/chemistry , Spectrometry, Mass, Electrospray Ionization/standards , Temperature
6.
Analyst ; 135(5): 971-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20419245

ABSTRACT

Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphos-methyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 microg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.


Subject(s)
Agrochemicals/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Water Pollutants, Chemical/analysis , Agrochemicals/chemistry , Cold Temperature , Food Analysis , Fruit/chemistry , Limit of Detection , Vegetables/chemistry , Water Pollutants, Chemical/chemistry
7.
J Am Soc Mass Spectrom ; 21(1): 132-5, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19879158

ABSTRACT

The capabilities of a portable mass spectrometer for real-time monitoring of trace levels of benzene, toluene, and ethylbenzene in air are illustrated. An atmospheric pressure interface was built to implement atmospheric pressure chemical ionization for direct analysis of gas-phase samples on a previously described miniature mass spectrometer (Gao et al. Anal. Chem.2006, 78, 5994-6002). Linear dynamic ranges, limits of detection and other analytical figures of merit were evaluated: for benzene, a limit of detection of 0.2 parts-per-billion was achieved for air samples without any sample preconcentration. The corresponding limits of detection for toluene and ethylbenzene were 0.5 parts-per-billion and 0.7 parts-per-billion, respectively. These detection limits are well below the compounds' permissible exposure levels, even in the presence of added complex mixtures of organics at levels exceeding the parts-per-million level. The linear dynamic ranges of benzene, toluene, and ethylbenzene are limited to approximately two orders of magnitude by saturation of the detection electronics.


Subject(s)
Air/analysis , Benzene Derivatives/analysis , Benzene/analysis , Mass Spectrometry/instrumentation , Mass Spectrometry/methods , Toluene/analysis , Atmospheric Pressure , Equipment Design , Ions/chemistry , Limit of Detection
8.
Rapid Commun Mass Spectrom ; 23(19): 3057-62, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19705382

ABSTRACT

A fast, reagentless, and direct method is presented for the mass spectrometric analysis of olive oil without any sample pretreatment whatsoever. An ambient ionization technique, the low-temperature plasma (LTP) probe, based on dielectric barrier discharge, is used to detect both minor and trace components (free fatty acids, phenolics and volatiles) in raw untreated olive oil. The method allows the measurement of free fatty acids (the main quality control parameter used to grade olive oil according to quality classes), selected bioactive phenolic compounds, and volatiles. The advantages and limitations of the direct analysis of extremely complex mixtures by the ambient ionization/tandem mass spectrometry combination are discussed and illustrated. The data presage the possible large-scale application of direct mass spectrometric analysis methods in the characterization of olive oil and other foodstuffs.


Subject(s)
Plant Oils/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Cold Temperature , Olive Oil
9.
Anal Chem ; 80(19): 7198-205, 2008 Oct 01.
Article in English | MEDLINE | ID: mdl-18754674

ABSTRACT

A wireless-controlled miniature rectilinear ion trap mass spectrometer system, total weight with batteries 5.0 kg, consuming less than 35 W of power, and having dimensions of 22 cm in length by 12 cm in width by 18 cm in height, is characterized. The design and construction of the mass spectrometer including mass analyzer, vacuum system, electronics system, and data acquisition and processing systems, is detailed. The mass spectrometer is compatible with various types of ionization sources including a glow discharge electron impact ionization source used in the internal ionization mode, and various atmospheric pressure ionization sources, including electrospray ionization, atmospheric pressure chemical ionization, and desorption electrospray ionization, which are employed for external, atmospheric pressure ionization. These external sources are coupled to the miniature mass spectrometer via a capillary interface that is operated in a discontinuous fashion (discontinuous atmospheric pressure interface) to maximize ion transport. The performance of the mass spectrometer for large and small molecules is characterized. Limits of detection in the parts-per-billion range were obtained for selected compounds examined using both the internal ionization and external ionization modes. Tandem mass spectrometry and fast in situ analysis capabilities are also demonstrated using a variety of compounds and ionization sources. Protein molecules are analyzed as the multiply protonated molecules with mass/charge ratios up to 1500 Da/charge.


Subject(s)
Tandem Mass Spectrometry/instrumentation , Miniaturization/instrumentation , Sensitivity and Specificity
10.
Anal Chem ; 80(23): 9097-104, 2008 Dec 01.
Article in English | MEDLINE | ID: mdl-19551980

ABSTRACT

A low-temperature plasma (LTP) probe has been developed for ambient desorption ionization. An ac electric field is used to induce a dielectric barrier discharge through use of a specially designed electrode configuration. The low-temperature plasma is extracted from the probe where it interacts directly with the sample being analyzed, desorbing and ionizing surface molecules in the ambient environment. This allows experiments to be performed without damage to the sample or underlying substrate and, in the case of biological analysis on skin surfaces, without electrical shock or perceptible heating. Positive or negative ions are produced from a wide range of chemical compounds in the pure stateand as mixtures in the gaseous, solution, or condensed phases, using He, Ar, N2, or ambient air as the discharge gas. Limited fragmentation occurs, although it is greater in the cases of the molecular than the atomic discharge gases. The effectiveness of the LTP probe has been demonstrated by recording characteristic mass spectra and tandem mass spectra of samples containing hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and 2,4,6-trinitrotoluene (TNT) from poly(tetrafluoroethylene) (PTFE) surfaces where limits of detection are as low as 5 pg. Other performance characteristics, when using a commercial ion trap mass spectrometer, include 3-4 orders of magnitude linear dynamic range in favorable cases. Demonstration applications include direct analysis of cocaine from human skin, determination of active ingredients directly in drug tablets, and analysis of toxic and therapeutic compounds in complex biological samples. Ionization of chemicals directly from bulk aqueous solution has been demonstrated, where limits of detection are as low as 1 ppb. Large surface area sampling and control of fragmentation by a simple adjustment of the electrode configuration during operation are other demonstrated characteristics of the method.


Subject(s)
Spectrometry, Mass, Electrospray Ionization/instrumentation , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Cold Temperature , Dogs , Equipment Design , Explosive Agents/analysis , Gastrointestinal Contents/chemistry , Humans , Nicotine/analysis , Pharmaceutical Preparations/analysis , Skin/chemistry , Stomach/chemistry , Water/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...