Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
J Cardiovasc Magn Reson ; : 101060, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-39004418

ABSTRACT

BACKGROUND: Individuals with a Fontan circulation encompass a heterogenous group with adverse outcomes linked to ventricular dilation, dysfunction, and dyssynchrony. The purpose of this study was to assess if unsupervised machine learning cluster analysis of cardiac magnetic resonance (CMR)-derived dyssynchrony metrics can separate ventricles in the Fontan circulation from normal control left ventricles and identify prognostically distinct subgroups within the Fontan cohort. MATERIALS AND METHODS: This single-center, retrospective study used 503 CMR studies from Fontan patients (median age 15y) and 42 from age-matched controls from January 2005 to May 2011. Feature tracking on short-axis cine stacks assessed radial and circumferential strain, strain rate, and displacement. Unsupervised K-means clustering was applied to 24 mechanical dyssynchrony metrics derived from these deformation measurements. Clusters were compared for demographic, anatomical, and composite outcome of death, or heart transplantation. RESULTS: Four distinct phenotypic clusters were identified. Over a median follow-up of 4.2y (IQR 1.7-8.8y), 58 (11.5%) patients met the composite outcome. The highest risk cluster (largely comprised of right or mixed ventricular morphology and dilated, dyssynchronous ventricles) exhibited a higher hazard for the composite outcome compared to the lowest-risk cluster while controlling for ventricular morphology (HR 6.4; 95% CI 2.1-19.3; P value 0.001) and higher indexed end-diastolic volume (HR 3.2; 95% CI 1.04-10.0; P value 0.043) per 10ml/m2. CONCLUSIONS: Unsupervised machine learning using CMR-derived dyssynchrony metrics identified four distinct clusters of patients with Fontan circulation and healthy controls with varying clinical characteristics and risk profiles. This technique can be used to guide future studies and identify more homogeneous subsets of patients from an overall heterogeneous population.

2.
J Am Soc Echocardiogr ; 37(6): 634-640, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38467312

ABSTRACT

Accurate knowledge of right ventricular (RV) volumes and ejection fraction is fundamental to providing optimal care for pediatric patients with congenital and acquired heart disease, as well as pulmonary hypertension. Traditionally, these volumes have been measured using cardiac magnetic resonance because of its accuracy, reproducibility, and freedom from geometric assumptions. More recently, an increasing number of studies have described the measurement of RV volumes using three-dimensional (3D) echocardiography. In addition, volumes by 3D echocardiography have also been used for outcome research studies in congenital heart surgery. Importantly, 3D echocardiographic acquisitions can be obtained over a small number of cardiac cycles, do not require general anesthesia, and are less costly than CMR. The ease and safety of the 3D echocardiographic acquisitions allow serial studies in the same patient. Moreover, the studies can be performed in various locations, including the intensive care unit, catheterization laboratory, and general clinic. Because of these advantages, 3D echocardiography is ideal for serial evaluation of the same patient. Despite these potential advantages, 3D echocardiography has not become a standard practice in children with congenital and acquired heart conditions. In this report, the authors review the literature on the feasibility, reproducibility, and accuracy of 3D echocardiography in pediatric patients. In addition, the authors investigate the advantages and limitations of 3D echocardiography in RV quantification and offer a pathway for its potential to become a standard practice in the assessment, planning, and follow-up of congenital and acquired heart disease.


Subject(s)
Echocardiography, Three-Dimensional , Humans , Echocardiography, Three-Dimensional/methods , Child , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Reproducibility of Results , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/physiopathology , Stroke Volume/physiology , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Child, Preschool , Infant , Sensitivity and Specificity , Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Heart Diseases/diagnosis
4.
J Am Soc Echocardiogr ; 37(2): 259-267, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37995938

ABSTRACT

BACKGROUND: The dynamic shape of the normal adult mitral annulus has been shown to be important to mitral valve function. However, annular dynamics of the healthy mitral valve in children have yet to be explored. The aim of this study was to model and quantify the shape and major modes of variation of pediatric mitral valve annuli in four phases of the cardiac cycle using transthoracic echocardiography. METHODS: The mitral valve annuli of 100 children and young adults with normal findings on three-dimensional echocardiography were modeled in four different cardiac phases using the SlicerHeart extension for 3D Slicer. Annular metrics were quantified using SlicerHeart, and optimal normalization to body surface area was explored. Mean annular shapes and the principal components of variation were computed using custom code implemented in a new SlicerHeart module (Annulus Shape Analyzer). Shape was regressed over metrics of age and body surface area, and mean shapes for five age-stratified groups were generated. RESULTS: The ratio of annular height to commissural width of the mitral valve ("saddle shape") changed significantly throughout age for systolic phases (P < .001) but within a narrow range (median range, 0.20-0.25). Annular metrics changed statistically significantly between the diastolic and systolic phases of the cardiac cycle. Visually, the annular shape was maintained with respect to age and body surface area. Principal-component analysis revealed that the pediatric mitral annulus varies primarily in size (mode 1), ratio of annular height to commissural width (mode 2), and sphericity (mode 3). CONCLUSIONS: The saddle-shaped mitral annulus is maintained throughout childhood but varies significantly throughout the cardiac cycle. The major modes of variation in the pediatric mitral annulus are due to size, ratio of annular height to commissural width, and sphericity. The generation of age- and size-specific mitral annular shapes may inform the development of appropriately scaled absorbable or expandable mitral annuloplasty rings for children.


Subject(s)
Echocardiography, Three-Dimensional , Heart Valve Prosthesis , Mitral Valve Insufficiency , Young Adult , Humans , Child , Mitral Valve/surgery , Echocardiography , Echocardiography, Three-Dimensional/methods
5.
J Am Heart Assoc ; 12(21): e031090, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37929755

ABSTRACT

Background Patients with pulmonary atresia or critical pulmonary stenosis with intact ventricular septum (PA/IVS) and biventricular circulation may require pulmonary valve replacement (PVR). Right ventricular (RV) remodeling after PVR is well described in tetralogy of Fallot (TOF); we sought to investigate RV changes in PA/IVS using cardiac magnetic resonance imaging. Methods and Results A retrospective cohort of patients with PA/IVS who underwent PVR at Boston Children's Hospital from 1995 to 2021 with cardiac magnetic resonance imaging before and after PVR was matched 1:3 with patients with TOF by age at PVR. Median regression modeling was performed with post-PVR indexed RV end-diastolic volume as the primary outcome. A total of 20 patients with PA/IVS (cases) were matched with 60 patients with TOF (controls), with median age at PVR of 14 years. Pre-PVR indexed RV end-diastolic volume was similar between groups; cases had higher RV ejection fraction (51.4% versus 48.6%; P=0.03). Pre-PVR RV free wall and left ventricular (LV) longitudinal strain were similar, although LV midcavity circumferential strain was decreased in cases (-15.6 versus -17.1; P=0.001). At a median of 2 years after PVR, indexed RV end-diastolic volume was similarly reduced; cases continued to have higher RV ejection fraction (52.3% versus 46.9%; P=0.007) with less reduction in RV mass (Δ4.5 versus 9.6 g/m2; P=0.004). Post-PVR, RV and LV longitudinal strain remained unchanged, and LV circumferential strain was similar, although lower in cases. Conclusions Compared with patients with TOF, patients with PA/IVS demonstrate similar RV remodeling after PVR, with lower reduction in RV mass and comparatively higher RV ejection fraction. Although no differences were detected in peak systolic RV or LV strain values, further investigation of diastolic parameters is needed.


Subject(s)
Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Pulmonary Atresia , Pulmonary Valve , Tetralogy of Fallot , Ventricular Septum , Child , Humans , Adolescent , Pulmonary Valve/surgery , Ventricular Septum/surgery , Retrospective Studies , Constriction, Pathologic , Heart Defects, Congenital/surgery , Tetralogy of Fallot/surgery , Ventricular Function, Right , Ventricular Remodeling , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
6.
J Cardiovasc Magn Reson ; 25(1): 66, 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-37986080

ABSTRACT

BACKGROUND: Ventricular dyssynchrony and its relationship to clinical outcomes is not well characterized in patients following Fontan palliation. METHODS: Single-center retrospective analysis of cardiac magnetic resonance (CMR) imaging of patients with a Fontan circulation and an age-matched healthy comparison cohort as controls. Feature tracking was performed on all slices of a ventricular short-axis cine stack. Circumferential and radial strain, strain rate, and displacement were measured; and multiple dyssynchrony metrics were calculated based on timing of these measurements (including standard deviation of time-to-peak, maximum opposing wall delay, and maximum base-to-apex delay). Primary endpoint was a composite measure including time to death, heart transplant or heart transplant listing (D/HTx). RESULTS: A total of 503 cases (15 y; IQR 10, 21) and 42 controls (16 y; IQR 11, 20) were analyzed. Compared to controls, Fontan patients had increased dyssynchrony metrics, longer QRS duration, larger ventricular volumes, and worse systolic function. Dyssynchrony metrics were higher in patients with right ventricular (RV) or mixed morphology compared to those with LV morphology. At median follow-up of 4.3 years, 11% had D/HTx. Multiple risk factors for D/HTx were identified, including RV morphology, ventricular dilation, dysfunction, QRS prolongation, and dyssynchrony. Ventricular dilation and RV morphology were independently associated with D/HTx. CONCLUSIONS: Compared to control LVs, single right and mixed morphology ventricles in the Fontan circulation exhibit a higher degree of mechanical dyssynchrony as evaluated by CMR-FT. Dyssynchrony indices correlate with ventricular size and function and are associated with death or need for heart transplantation. These data add to the growing understanding regarding factors that can be used to risk-stratify patients with the Fontan circulation.


Subject(s)
Fontan Procedure , Humans , Fontan Procedure/adverse effects , Retrospective Studies , Predictive Value of Tests , Heart Ventricles , Heart
8.
Front Cardiovasc Med ; 10: 1141027, 2023.
Article in English | MEDLINE | ID: mdl-37600046

ABSTRACT

Background: The right ventricle (RV) has complex geometry and function, with motion along three separate axes-longitudinal, radial, and anteroposterior. Quantitative assessment of RV function by two-dimension echocardiography (2DE) has been limited as a consequence of this complexity, whereas newer three dimensional (3D) analysis offers the potential for more comprehensive assessment of the contributors to RV function. The aims of this study were to quantify the longitudinal, radial and anteroposterior components of global RV function using 3D echocardiography in a cohort of healthy children and to examine maturational changes in these parameters. Methods: Three-dimensional contours of the RV were generated from a cohort of healthy pediatric patients with structurally normal hearts at two centers. Traditional 2D and 3D echo characteristics were recorded. Using offline analysis of 3D datasets, RV motion was decomposed into three components, and ejection fractions (EF) were calculated (longitudinal-LEF; radial-REF; and anteroposterior-AEF). The individual decomposed EF values were indexed against the global RVEF. Strain values were calculated as well. Results: Data from 166 subjects were included in the analysis; median age was 13.5 years (range 0 to 17.4 years). Overall, AEF was greater than REF and LEF (29.2 ± 6.2% vs. 25.1 ± 7.2% and 25.7 ± 6.0%, respectively; p < 0.001). This remained true when indexed to overall EF (49.8 ± 8.7% vs. 43.3 ± 11.6% and 44.4 ± 10%, respectively; p < 0.001). Age-related differences were present for global RVEF, REF, and all components of RV strain. Conclusions: In healthy children, anteroposterior shortening is the dominant component of RV contraction. Evaluation of 3D parameters of the RV in children is feasible and enhances the overall understanding of RV function, which may allow improvements in recognition of dysfunction and assessment of treatment effects in the future.

9.
Pediatr Cardiol ; 2023 Jul 13.
Article in English | MEDLINE | ID: mdl-37442851

ABSTRACT

BACKGROUND: Interventional therapies for severe pulmonary arterial hypertension (PAH) can provide right ventricular (RV) decompression and preserve cardiac output. Transcatheter stent placement in a residual ductus arteriosus (PDA) is one potentially effective option in critically ill infants and young children with PAH. We sought to assess recovery of RV function by echocardiographic strain in infants and young children following PDA stenting for acute PAH. METHODS: Retrospective review of patients < 2 years old who underwent PDA stenting for acute PAH. Clinical data were abstracted from the electronic medical record. RV strain (both total and free wall components) was assessed from echocardiographic images at baseline and 3, 6, and 12 months post-intervention, as well as at last echocardiogram. RESULTS: Nine patients underwent attempted ductal stenting for PAH. The median age at intervention was 38 days and median weight 3.7 kg. One-third (3of 9) of patients had PAH associated with a congenital diaphragmatic hernia. PDA stents were successfully deployed in eight patients. Mean RV total strain was - 14.9 ± 5.6% at baseline and improved to - 23.8 ± 2.2% at 6 months post-procedure (p < 0.001). Mean free wall RV strain was - 19.5 ± 5.4% at baseline and improved to - 27.7 ± 4.1% at 6 months (p = 0.002). Five patients survived to discharge, and four patients survived 1 year post-discharge. CONCLUSION: PDA stenting for severe, acute PAH can improve RV function as assessed by strain echocardiography. The quantitative improvement is more prominent in the first 6 months post-procedure and stabilizes thereafter.

10.
Front Cardiovasc Med ; 10: 1137814, 2023.
Article in English | MEDLINE | ID: mdl-37215544

ABSTRACT

Background: Accurate measurement of ventricular volumes is an important clinical imaging goal. Three-dimensional echocardiography (3DEcho) is used increasingly as it is more available and less costly than cardiac magnetic resonance (CMR). For the right ventricle (RV), the current practice is to acquire 3DEcho volumes from the apical view. However, in some patients the RV may be better seen from the subcostal view. Therefore, this study compared RV volume measurements from the apical vs. the subcostal view, using CMR as a reference standard. Methods: Patients <18 years old undergoing a clinical CMR examination were prospectively enrolled. 3DEcho was performed on the day of the CMR. 3DEcho images were acquired with Philips Epic 7 ultrasound system from apical and subcostal views. Offline analysis was performed with TomTec 4DRV Function for 3DEcho images and cvi42 for CMR ones. RV end-diastolic volume and end-systolic volume were collected. Agreement between 3DEcho and CMR was assessed with Bland-Altman analysis and the intraclass correlation coefficient (ICC). Percentage (%) error was calculated using CMR as the reference standard. Results: Forty-seven patients were included in the analysis (age range 10 months to 16 years). The ICC was moderate to excellent for all volume comparisons to CMR (subcostal vs. CMR: end-diastolic volume 0.93, end-systolic volume 0.81; apical vs. CMR: end-diastolic volume 0.94, end-systolic volume 0.74).The 3DEcho mean % error vs. CMR for end-systolic volume was 25% for subcostal and 31% for apical; for end-diastolic volume it was 15% for subcostal and 16% for apical. The % error was not significantly different between apical vs. subcostal views for end-systolic and end-diastolic volume measurements. Conclusions: For apical and subcostal views, 3DEcho-derived ventricular volumes agree well with CMR. Neither echo view has a consistently smaller error when compared to CMR volumes. Accordingly, the subcostal view can be used as an alternative to the apical view when acquiring 3DEcho volumes in pediatric patients, particularly when the image quality from this window is superior.

11.
J Am Soc Echocardiogr ; 36(3): 310-323, 2023 03.
Article in English | MEDLINE | ID: mdl-36414123

ABSTRACT

BACKGROUND: Strain values vary with age in children and are both vendor and platform specific. Philips QLAB 10.8 and TomTec AutoSTRAIN are two widely used strain analysis platforms, and both incorporate recent European Association of Cardiovascular Imaging/American Society of Echocardiography/Industry Task Force to Standardize Deformation Imaging guidelines. The aims of this study were to establish normal strain values and Z scores for both platforms using a large data set of healthy children and to compare values among these two platforms and a previous version, QLAB 10.5, which predated the task force guidelines. METHODS: Echocardiograms from 1,032 subjects <21 years old with structurally and functionally normal hearts were included. Images were obtained on the Philips EPIQ platform. Left ventricular (LV) and right ventricular (RV) strain was analyzed using QLAB 10.8 and AutoSTRAIN, and measurement reliability was assessed. Z score equations were derived as a function of age for QLAB 10.8 (LV longitudinal and circumferential strain) and AutoSTRAIN (LV and RV longitudinal strain). A subset (n = 309) was analyzed using QLAB 10.5. Strain values were compared among the three platforms. RESULTS: For both of the newer platforms, strain varied with age, with magnitude reaching a maximum at 4 to 5 years. For LV longitudinal strain, the largest differences in value were observed in the youngest patients when using QLAB 10.5; the other two platforms were similar. LV circumferential strain measurements (QLAB 10.5 vs QLAB 10.8) were different for all ages, as were measurements of RV longitudinal strain (QLAB 10.8 vs AutoSTRAIN). Reliability was greater for AutoSTRAIN than for QLAB 10.8 and greater for LV than for RV strain. CONCLUSIONS: Normal RV and LV strain values and Z scores were generated from a large cohort of children for two commonly used platforms in pediatric echocardiography laboratories. Following the incorporation of task force guidelines, the greatest improvement in standardization was seen in infants. Small differences persist between modern platforms; however, these results support the cautious consideration of comparing interplatform measurements.


Subject(s)
Echocardiography , Heart Ventricles , Infant , Child , Humans , Child, Preschool , Young Adult , Adult , Reference Values , Reproducibility of Results , Prospective Studies , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Ventricular Function, Left
12.
Circ Cardiovasc Imaging ; 15(11): e013676, 2022 11.
Article in English | MEDLINE | ID: mdl-36378780

ABSTRACT

BACKGROUND: The FUEL trial (Fontan Udenafil Exercise Longitudinal) demonstrated statistical improvements in exercise capacity following 6 months of treatment with udenafil (87.5 mg po BID). The effect of udenafil on echocardiographic measures of single ventricle function in this cohort has not been studied. METHODS: The 400 enrolled participants were randomized 1:1 to udenafil or placebo. Protocol echocardiograms were obtained at baseline and 26 weeks after initiation of udenafil/placebo. Linear regression compared change from baseline indices of single ventricle systolic, diastolic and global function, atrioventricular valve regurgitation, and mean Fontan fenestration gradient in the udenafil cohort versus placebo, controlling for ventricular morphology (left ventricle versus right ventricle/other) and baseline value. RESULTS: The udenafil participants (n=191) had significantly improved between baseline and 26 weeks visits compared to placebo participants (n=195) in myocardial performance index (P=0.03, adjusted mean difference [SE] of changes between groups -0.03[0.01]), atrioventricular valve inflow peak E (P=0.009, 3.95 [1.50]), and A velocities (P=0.034, 3.46 [1.62]), and annular Doppler tissue imaging-derived peak e' velocity (P=0.008, 0.60[0.23]). There were no significant differences in change in single ventricle size, systolic function, atrioventricular valve regurgitation severity, or mean fenestration gradient. Participants with a dominant left ventricle had significantly more favorable baseline values of indices of single ventricle size and function (lower volumes and areas, E/e' ratio, systolic:diastolic time and atrioventricular valve regurgitation, and higher annular s' and e' velocity). CONCLUSIONS: FUEL participants who received udenafil demonstrated a statistically significant improvement in some global and diastolic echo indices. Although small, the changes in diastolic function suggest improvement in pulmonary venous return and/or augmented ventricular compliance, which may help explain improved exercise performance in that cohort. REGISTRATION: URL: https://clinicaltrials.gov; Unique Identifier: NCT02741115.


Subject(s)
Echocardiography , Sulfonamides , Humans , Sulfonamides/therapeutic use , Pyrimidines/therapeutic use , Diastole , Ventricular Function, Left
13.
J Am Soc Echocardiogr ; 35(9): 985-996.e11, 2022 09.
Article in English | MEDLINE | ID: mdl-35537615

ABSTRACT

BACKGROUND: Repair of complete atrioventricular canal (CAVC) is often complicated by residual left atrioventricular valve regurgitation. The structure of the mitral and tricuspid valves in biventricular hearts has previously been shown to be associated with valve dysfunction. However, the three-dimensional (3D) structure of the entire unrepaired CAVC valve has not been quantified. Understanding the 3D structure of the CAVC may inform optimized repair. METHODS: Novel open-source work flows were created in SlicerHeart for the modeling and quantification of CAVC valves on the basis of 3D echocardiographic images. These methods were applied to model the annulus, leaflets, and papillary muscle (PM) structure of 35 patients (29 with trisomy 21) with CAVC using transthoracic 3D echocardiography. The mean leaflet and annular shapes were calculated and visualized using shape analysis. Metrics of the complete native CAVC valve structure were compared with those of normal mitral valves using the Mann-Whitney U test. Associations between CAVC structure and atrioventricular valve regurgitation were analyzed. RESULTS: CAVC leaflet metrics varied throughout systole. Compared with normal mitral valves, the left CAVC PMs were more acutely angled in relation to the annular plane (P < .001). In addition, the anterolateral PM was laterally and inferiorly rotated in CAVC, while the posteromedial PM was more superiorly and laterally rotated, relative to normal mitral valves (P < .001). Lower native CAVC atrioventricular valve annular height and annular height-to-valve width ratio before repair were both associated with moderate or greater left atrioventricular valve regurgitation after repair (P < .01). CONCLUSIONS: It is feasible to model and quantify 3D CAVC structure using 3D echocardiographic images. The results demonstrate significant variation in CAVC structure across the cohort and differences in annular, leaflet, and PM structure compared with the mitral valve. These tools may be used in future studies to catalyze future research intended to identify structural associations of valve dysfunction and to optimize repair in this vulnerable and complex population.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects , Mitral Valve Insufficiency , Echocardiography, Three-Dimensional/methods , Humans , Mitral Valve/surgery , Software
14.
Can J Cardiol ; 38(9): 1426-1433, 2022 09.
Article in English | MEDLINE | ID: mdl-35526821

ABSTRACT

BACKGROUND: Three-dimensional echocardiography (3DE) evaluation of right ventricular (RV) volumes and ejection fraction (EF) is increasingly used for clinical serial assessments and management in children. This study aims to generate sex-specific reference values and z-score equations for RV volumetric parameters, independent of age and body size indices, derived from multiple populations across North America. METHODS: We prospectively recruited 455 healthy children (ages 0 to 18 years) from 5 centres. 3DE of the RV were acquired using various vendors with analyses performed offline using vendor-independent software. 3DE datasets with all walls of the RV endocardium visible were included. We reported data on RV EF, and generated z scores for end-systolic volumes (ESV), end-diastolic volumes (EDV) and stroke volume (SV). Differences between the sexes were explored. RESULTS: Of 455 3DE datasets, 312 (68%) met imaging criteria for analysis. Median age was 10.1 years (interquartile ratio [IQR]: 5.6, 14.0) with 17% being younger than 3 years of age. The mean and standard deviation for RV EDV, ESV, and SV for male and female patients were reported. We provided a downloadable z-score calculator with height and weight as independent variables to facilitate clinical utility. Although statistically significant differences between male and female RVEF was present (female 52.9 ± 3.9% vs male 51.6 ± 3.5%, P = 0.006), after adjusting for age, height, and weight, the magnitude of difference was clinically insignificant. CONCLUSIONS: Sex-specific reference values for pediatric RV volumes and EF, and z-score equations were derived from children 3DE datasets across 5 centres in North America.


Subject(s)
Echocardiography, Three-Dimensional , Adolescent , Child , Child, Preschool , Echocardiography, Three-Dimensional/methods , Female , Heart Ventricles/diagnostic imaging , Humans , Infant , Infant, Newborn , Male , Reference Values , Reproducibility of Results , Stroke Volume , Ventricular Function, Left
16.
Ann Thorac Surg ; 113(2): 654-662, 2022 02.
Article in English | MEDLINE | ID: mdl-33359720

ABSTRACT

BACKGROUND: Repair of complete atrioventricular canal (CAVC) is often complicated by atrioventricular valve regurgitation, particularly of the left-sided valve. Understanding the 3-dimensional (3D) structure of the atrioventricular canal annulus before repair may help to inform optimized repair. However, the 3D shape and movement of the CAVC annulus has been neither quantified nor rigorously compared with a normal mitral valve annulus. METHODS: The complete annuli of 43 patients with CAVC were modeled in 4 cardiac phases using transthoracic 3D echocardiograms and custom code. The annular structure was compared with the annuli of 20 normal pediatric mitral valves using 3D metrics and statistical shape analysis (Procrustes analysis). RESULTS: The unrepaired CAVC annulus varied in shape significantly throughout the cardiac cycle. Procrustes analysis visually demonstrated that the average normalized CAVC annular shape is more planar than the normal mitral annulus. Quantitatively, the annular height-to-valve width ratio of the native left CAVC atrioventricular valve was significantly lower than that of a normal mitral valve in all systolic phases (P < .001). CONCLUSIONS: The left half of the CAVC annulus is more planar than that of a normal mitral valve with an annular height-to-valve width ratio similar to dysfunctional mitral valves. Given the known importance of annular shape to mitral valve function, further exploration of the association of 3D structure to valve function in CAVC is warranted.


Subject(s)
Cardiac Surgical Procedures/methods , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Septal Defects/surgery , Child, Preschool , Female , Heart Septal Defects/diagnosis , Humans , Infant , Male , Retrospective Studies
17.
Am J Cardiol ; 162: 177-183, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34903340

ABSTRACT

Several circulating biomarkers have been found to play a role in the surveillance and risk stratification of heart failure without congenital heart disease, but these have not been widely studied in patients with single ventricles palliated with a Fontan operation. Imaging predictors of worse outcomes in this population include ventricular dilation and dysfunction. Patients who weighed >30 kg with a Fontan circulation referred for cardiac magnetic resonance imaging were invited to participate in the study. Blood and urine samples were obtained at the time of imaging and multiple conventional and novel biomarkers were measured. A total of 82 patients with a median age of 18 years were enrolled. Among the novel biomarkers, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and high-sensitivity troponin T had the strongest correlation with ventricular dilation and dysfunction. NT-ProBNP >100 pg/ml has a sensitivity of 91% for the detection of significant ventricular dilation (end-diastolic volume >120 ml/body surface area1.3) and 82% for detection of ejection fraction <50%. The urinary neutrophil gelatinase-associated lipocalin-2 to creatinine ratio correlated with ejection fraction and estimated glomerular filteration rate. In conclusion, abnormalities in biomarkers of heart failure are common in ambulatory, largely asymptomatic patients with Fontan circulation. NT-ProBNP may serve as a sensitive marker for the identification of patients with significant ventricular dilation or dysfunction. Further work is needed to understand how these easily measured circulating biomarkers may be integrated into clinical care.


Subject(s)
Fontan Procedure , Heart Defects, Congenital/blood , Heart Defects, Congenital/urine , Heart Failure/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Adolescent , Biomarkers/blood , Biomarkers/urine , Cohort Studies , Creatinine/metabolism , Cross-Sectional Studies , Female , Glomerular Filtration Rate , Heart Defects, Congenital/surgery , Heart Failure/blood , Heart Failure/urine , Humans , Lipocalin-2/metabolism , Magnetic Resonance Imaging , Male , Natriuretic Peptide, Brain/metabolism , Peptide Fragments/metabolism , Sensitivity and Specificity , Stroke Volume/physiology , Troponin T/metabolism , Ventricular Dysfunction, Left/blood , Ventricular Dysfunction, Left/urine , Young Adult
18.
J Am Soc Echocardiogr ; 34(12): 1303-1315.e3, 2021 12.
Article in English | MEDLINE | ID: mdl-34325008

ABSTRACT

BACKGROUND: Strain rate (SR) parameters derived from two-dimensional speckle-tracking echocardiography have prognostic value in children with heart disease. Routine use is hindered by a lack of normative data. The aim of this study was to determine reference values and Z scores for left ventricular systolic and diastolic SR in a large cohort of healthy children. METHODS: Echocardiograms from 577 subjects ≤18 years of age (mean age, 9.6 ± 5.6 years; range, 1 day to 18.0 years; 46% female) with structurally and functionally normal hearts were retrospectively included. Left ventricular longitudinal and circumferential systolic and early and late diastolic SR were measured using two-dimensional speckle-tracking echocardiography from the apical four-chamber and short-axis mid-papillary views. Associations with age and body surface area were assessed using Spearman correlation and generalized additive modeling. The relationship between systolic SR and wall stress (afterload) was examined. Analyses were conducted with and without correction for heart rate. Multivariable linear regression modeling was used to identify independent factors associated with the SR parameters. Z score equations were derived from a selected best-fit parametric model. RESULTS: All SR parameters differed significantly by age group. The magnitude of all SR values decreased with increasing age and body surface area. Systolic SR magnitude was inversely related to wall stress in children ≤7 years of age but not did not vary significantly in the older age groups. All relationships were maintained after heart rate correction. SR measurements had very good or excellent agreement. CONCLUSION: Longitudinal and circumferential systolic and diastolic SR parameters are presented from a large cohort of healthy children using two-dimensional speckle-tracking echocardiography from the Philips platform. SR values differ significantly by age and body surface area. These results suggest that the myocardium becomes less sensitive to afterload with maturity. Z score equations based on age are presented, which should promote further clinical and research use.


Subject(s)
Echocardiography , Heart Diseases , Adolescent , Aged , Child , Child, Preschool , Female , Heart Rate , Humans , Infant , Male , Reference Values , Retrospective Studies
19.
Echocardiography ; 38(4): 641-645, 2021 04.
Article in English | MEDLINE | ID: mdl-33682205

ABSTRACT

BACKGROUND: Three-dimensional echocardiography (3DE) evaluation of left ventricular (LV) volume and function in pediatrics compares favorably with cardiac magnetic resonance imaging. The aim of this study was to establish from a multicenter, normal pediatric z-score values of 3DE left ventricular volumes and function. METHODS: Six hundred and ninety-eight healthy children (ages 0-18 years) were recruited from five centers. LV 3DE was acquired from the 4-chamber view. A vendor-independent software analyzed end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) using semi-automated quantification. Body surface area (BSA)-based z-scores were generated. Intraobserver and interobserver variability were calculated using intraclass correlation (ICC) and repeatability coefficient (RC). RESULTS: Z-scores were generated for ESV, EDV, and SV. The ICC for intraobserver variability for EDV, ESV, and SV was 0.99, 0.99, and 0.99, respectively. The ICC for interobserver variability for EDV, ESV, and SV was 0.98, 0.94, and 0.98, respectively. The RC for intraobserver and interobserver variability for LV EF was 4.39% (95% CI: 3.01, 5.59) and interobserver was 7.08% (95%CI: 5.51, 8.42). CONCLUSIONS: We report pediatric z-scores for normal LV volumes using the semi-automated method from five centers, enhancing its generalizability. 3DE evaluation of LV volumes and EF in pediatric patients is highly reproducible.


Subject(s)
Echocardiography, Three-Dimensional , Pediatrics , Adolescent , Child , Child, Preschool , Heart Ventricles/diagnostic imaging , Humans , Infant , Infant, Newborn , Reproducibility of Results , Stroke Volume , Ventricular Function, Left
20.
CJC Open ; 3(7): 880-887, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33649742

ABSTRACT

BACKGROUND: Cardiac manifestations in multisystem inflammatory syndrome in children (MIS-C) occur in ∼80% of patients. Left ventricular (LV) systolic dysfunction is the most frequent cardiac finding. METHODS: In this single-centre, retrospective cohort study, we report on detailed assessment of LV function in MIS-C patients using strain and strain rate analysis. We compare those with normal peak systolic strain z-scores (both longitudinal and circumferential strain) to those with abnormal peak systolic strain z-scores (decreased circumferential and/or longitudinal strain). RESULTS: Among 25 patients, 14 (56%) were male, 20 (80%) were Black or Hispanic, 13 (52%) were overweight/obese, and the median age was 11.4 years (interquartile range: 7.5 to 16). Median ejection fraction (EF) was 55.2% (interquartile range: 48.3% to 58%), with the abnormal strain patients having a lower EF (P < 0.01). Demographics were similar between groups. The abnormal strain patients had more organ systems involved and were more likely to require inotropic support. In a comparison of MIS-C patients with normal EF (n = 15) to controls, MIS-C patients had lower peak systolic strain as well as lower early diastolic strain rates. In patients with initially depressed function, EF normalized in 8 of 10 (80%), but 4 of 11 (36%) patients had persistently abnormal systolic strain after discharge. CONCLUSIONS: LV systolic dysfunction is common in the acute phase of MIS-C, and detection may be improved with strain imaging. Longitudinal cardiac follow-up is imperative, as some patients may be at risk for persistent LV dysfunction.


CONTEXTE: Des manifestations cardiaques sont observées chez environ 80 % des patients atteints du syndrome inflammatoire multisystémique de l'enfant (SIM-E). La dysfonction systolique ventriculaire gauche est le problème cardiaque observé le plus fréquemment. MÉTHODOLOGIE: Dans cette étude de cohorte rétrospective et unicentrique, nous rapportons les résultats d'une évaluation détaillée de la fonction ventriculaire gauche chez des patients atteints du SIM-E sous l'angle de l'étude des contraintes et des taux de contrainte. Nous comparons les patients dont les écarts z des pics de contrainte systolique sont normaux (contraintes tant longitudinales que circonférentielles) et ceux dont les écarts z des pics de contrainte systolique sont anormaux (réduction de la contrainte circonférentielle ou longitudinale). RÉSULTATS: Sur 25 patients, 14 (56 %) étaient de sexe masculin, 20 (80 %) étaient noirs ou hispaniques, 13 (52 %) étaient en surpoids ou obèses, et l'âge médian était de 11,4 ans (intervalle interquartile : de 7,5 à 16). La fraction d'éjection (FE) médiane était de 55,2 % (intervalle interquartile : de 48,3 % à 58 %), et était moins élevée chez les patients présentant une contrainte anormale (p < 0,01). Les caractéristiques démographiques étaient comparables dans tous les groupes. Les patients chez lesquels la contrainte était anormale présentaient un plus grand nombre d'organes atteints et étaient plus susceptibles de nécessiter un soutien inotrope. Comparativement au groupe témoin, les patients SIM-E ayant une FE normale (n = 15) présentaient un pic de contrainte systolique moins élevé et des taux de contrainte diastolique précoce plus faibles. Chez les patients dont la fonction était déprimée à l'origine, la FE s'est normalisée chez huit patients sur 10 (80 %), mais quatre sur 11 (36 %) présentaient une contrainte systolique persistant après leur sortie de l'hôpital. CONCLUSIONS: La dysfonction systolique ventriculaire gauche est fréquente dans la phase aiguë du SIM-E, et son repérage pourrait être amélioré par l'imagerie permettant de visualiser les contraintes. Un suivi cardiaque longitudinal est impératif, car certains patients peuvent être à risque de souffrir d'une dysfonction ventriculaire gauche persistante.

SELECTION OF CITATIONS
SEARCH DETAIL
...