Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Neurophotonics ; 11(1): 015008, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38464864

ABSTRACT

Significance: Bedside cerebral blood flow (CBF) monitoring has the potential to inform and improve care for acute neurologic diseases, but technical challenges limit the use of existing techniques in clinical practice. Aim: Here, we validate the Openwater optical system, a novel wearable headset that uses laser speckle contrast to monitor microvascular hemodynamics. Approach: We monitored 25 healthy adults with the Openwater system and concurrent transcranial Doppler (TCD) while performing a breath-hold maneuver to increase CBF. Relative blood flow (rBF) was derived from changes in speckle contrast, and relative blood volume (rBV) was derived from changes in speckle average intensity. Results: A strong correlation was observed between beat-to-beat optical rBF and TCD-measured cerebral blood flow velocity (CBFv), R=0.79; the slope of the linear fit indicates good agreement, 0.87 (95% CI: 0.83 -0.92). Beat-to-beat rBV and CBFv were also strongly correlated, R=0.72, but as expected the two variables were not proportional; changes in rBV were smaller than CBFv changes, with linear fit slope of 0.18 (95% CI: 0.17 to 0.19). Further, strong agreement was found between rBF and CBFv waveform morphology and related metrics. Conclusions: This first in vivo validation of the Openwater optical system highlights its potential as a cerebral hemodynamic monitor, but additional validation is needed in disease states.

2.
medRxiv ; 2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37873126

ABSTRACT

Bedside cerebral blood flow (CBF) monitoring has the potential to inform and improve care for acute neurologic diseases, but technical challenges limit the use of existing techniques in clinical practice. Here we validate the Openwater optical system, a novel wearable headset that uses laser speckle contrast to monitor microvascular hemodynamics. We monitored 25 healthy adults with the Openwater system and concurrent transcranial Doppler (TCD) while performing a breath-hold maneuver to increase CBF. Relative blood flow (rBF) was derived from the changes in speckle contrast, and relative blood volume (rBV) was derived from the changes in speckle average intensity. A strong correlation was observed between beat-to-beat optical rBF and TCD-measured cerebral blood flow velocity (CBFv), R=0.79; the slope of the linear fit indicates good agreement, 0.87 (95% CI:0.83-0.92). Beat-to-beat rBV and CBFv were strongly correlated, R=0.72, but as expected the two variables were not proportional; changes in rBV were smaller than CBFv changes, with linear fit slope of 0.18 (95% CI:0.17-0.19). Further, strong agreement was found between rBF and CBFv waveform morphology and related metrics. This first in vivo validation of the Openwater optical system highlights its potential as a cerebral hemodynamic monitor, but additional validation is needed in disease states.

3.
J Biophotonics ; 13(1): e201900108, 2020 01.
Article in English | MEDLINE | ID: mdl-31304655

ABSTRACT

Current clinical brain imaging techniques used for surgical planning of tumor resection lack intraoperative and real-time feedback; hence surgeons ultimately rely on subjective evaluation to identify tumor areas and margins. We report a fluorescence lifetime imaging (FLIm) instrument (excitation: 355 nm; emission spectral bands: 390/40 nm, 470/28 nm, 542/50 nm and 629/53 nm) that integrates with surgical microscopes to provide real-time intraoperative augmentation of the surgical field of view with fluorescent derived parameters encoding diagnostic information. We show the functionality and safety features of this instrument during neurosurgical procedures in patients undergoing craniotomy for the resection of brain tumors and/or tissue with radiation damage. We demonstrate in three case studies the ability of this instrument to resolve distinct tissue types and pathology including cortex, white matter, tumor and radiation-induced necrosis. In particular, two patients with effects of radiation-induced necrosis exhibited longer fluorescence lifetimes and increased optical redox ratio on the necrotic tissue with respect to non-affected cortex, and an oligodendroglioma resected from a third patient reported shorter fluorescence lifetime and a decrease in optical redox ratio than the surrounding white matter. These results encourage the use of FLIm as a label-free and non-invasive intraoperative tool for neurosurgical guidance.


Subject(s)
Augmented Reality , Brain Neoplasms , Neurosurgery , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Humans , Margins of Excision , Neurosurgical Procedures
4.
Biomed Opt Express ; 9(8): 3559-3580, 2018 Aug 01.
Article in English | MEDLINE | ID: mdl-30338140

ABSTRACT

Current clinical imaging modalities do not reliably identify brain tissue regions with necrosis following radiotherapy. This creates challenges for stereotaxic biopsies and surgical-decision making. Time-resolved fluorescence spectroscopy (TRFS) provides a means to rapidly identify necrotic tissue by its distinct autofluorescence signature resulting from tissue breakdown and altered metabolic profiles in regions with radiation damage. Studies conducted in a live animal model of radiation necrosis demonstrated that necrotic tissue is characterized by respective increases of 27% and 108% in average lifetime and redox ratio, when compared with healthy tissue. Moreover, radiation-damaged tissue not visible by MRI but confirmed by histopathology, was detected by TRFS. Current results demonstrate the ability of TRFS to identify radiation-damaged brain tissue in real-time and indicates its potential to assist with surgical guidance and MRI-guided biopsy procedures.

5.
Int J Radiat Biol ; 93(7): 676-682, 2017 07.
Article in English | MEDLINE | ID: mdl-28306402

ABSTRACT

PURPOSE: To provide a comprehensive understanding of how the selection of radiation dose affects the temporal and spatial progression of radiation-induced necrosis in the rat model. MATERIALS AND METHODS: Necrosis was induced with a single fraction of radiation exposure, at doses ranging between 20 and 60 Gy, to the right hemisphere of 8-week-old Fischer rats from a linear accelerator. The development and progression of necrosis in the rats was monitored and quantified every other week with T1- and T2-weighted gadolinium contrast-enhanced MRI studies. RESULTS: The time to onset of necrosis was found to be dose-dependent, but after the initial onset, the necrosis progression rate and total volume generated was constant across different doses ranging between 30 and 60 Gy. Radiation doses less than 30 Gy did not develop necrosis within 33 weeks after treatment, indicating a dose threshold existing between 20 and 30 Gy. CONCLUSION: The highest dose used in this study led to the shortest time to onset of radiation-induced necrosis, while producing comparable disease progression dynamics after the onset. Therefore, for the radiation-induced necrosis rat model using a linear accelerator, the most optimum results were generated from a dose of 60 Gy.


Subject(s)
Brain/pathology , Brain/radiation effects , Cranial Irradiation/adverse effects , Radiation Injuries/etiology , Radiation Injuries/pathology , Animals , Disease Progression , Dose-Response Relationship, Radiation , Male , Necrosis/etiology , Necrosis/pathology , Rats , Rats, Inbred F344
6.
J Environ Pathol Toxicol Oncol ; 35(2): 185-92, 2016.
Article in English | MEDLINE | ID: mdl-27481495

ABSTRACT

The translation of photodynamic therapy (PDT) to the clinical setting has primarily been limited to easily accessible and/or superficial diseases, for which traditional light delivery can be performed noninvasively. Cerenkov radiation, as generated from medically relevant radionuclides, has been suggested as a means to deliver light to deeper tissues noninvasively to overcome this depth limitation. This article investigates the utility of Cerenkov radiation, as generated from the radionuclide yttrium-90, for activating the PDT process using clinically approved aminolevulinic acid at 1.0 mm and also the more efficient porphyrin-based photosensitizer mesotetraphenylporphine with two sulfonate groups on adjacent phenyl rings (TPPS2a) at 1.2 µm. Experiments were conducted with monolayer cultured glioma and breast tumor cell lines. Although aminolevulinic acid proved to be ineffective for generating a therapeutic effect at all but the highest activity levels, TPPS2a produced at least a 20% therapeutic effect at activities ranging from 6 to 60 µCi/well for the C6 glioma cell line. Importantly, these results demonstrate for the first time, to our knowledge, that Cerenkov radiation generated from a radionuclide can be used to activate PDT using clinically relevant photosensitizers. These results therefore provide evidence that it may be possible to generate a phototherapeutic effect in vivo using Cerenkov radiation and clinically relevant photosensitizers.


Subject(s)
Aminolevulinic Acid/pharmacology , Photochemotherapy/methods , Yttrium Radioisotopes/pharmacology , Animals , Cell Line, Tumor , Cell Survival/drug effects , Cell Survival/radiation effects , Female , Humans , Photosensitizing Agents/pharmacology , Porphyrins/pharmacology , Rats
7.
Anal Bioanal Chem ; 407(27): 8291-301, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26093843

ABSTRACT

In this contribution we present a dual modality fiber optic probe combining fluorescence lifetime imaging (FLIm) and Raman spectroscopy for in vivo endoscopic applications. The presented multi-spectroscopy probe enables efficient excitation and collection of fluorescence lifetime signals for FLIm in the UV/visible wavelength region, as well as of Raman spectra in the near-IR for simultaneous Raman/FLIm imaging. The probe was characterized in terms of its lateral resolution and distance dependency of the Raman and FLIm signals. In addition, the feasibility of the probe for in vivo FLIm and Raman spectral characterization of tissue was demonstrated. Graphical Abstract An image comparison between FLIm and Raman spectroscopy acquired with the bimodal probe onseveral tissue samples.


Subject(s)
Fiber Optic Technology/instrumentation , Optical Imaging/instrumentation , Spectrum Analysis, Raman/instrumentation , Animals , Brain Chemistry , Endoscopy/instrumentation , Equipment Design , Humans , Rats, Inbred F344
8.
Biomed Opt Express ; 6(3): 770-9, 2015 Mar 01.
Article in English | MEDLINE | ID: mdl-25798302

ABSTRACT

The translation of photodynamic therapy (PDT) to the clinic has mostly been limited to superficial diseases where traditional light delivery is noninvasive. To overcome this limitation, a variety of mechanisms have been suggested to noninvasively deliver light to deep tissues. This work explores the minimum amount of light required by these methods to produce a meaningful PDT effect in the in vitro setting under representative low fluence and wavelength conditions. This threshold was found to be around 192 mJ/cm(2) using the clinically approved photosensitizer aminolevulinic acid and 12 mJ/cm(2) for the more efficient, second generation photosensitizer TPPS2a.

9.
IEEE J Sel Top Quantum Electron ; 18(4): 1465-1477, 2012.
Article in English | MEDLINE | ID: mdl-28053498

ABSTRACT

Clinical outcome of patients diagnosed with primary brain tumor has been correlated with the extent of surgical resection. In treating this disease, the neurosurgeon must balance between an aggressive, radical resection and minimizing the loss of healthy, functionally significant brain tissue. Numerous intra-operative methodologies and technological approaches have been explored as a means to improve the accuracy of surgical resection. This paper presents an overview of current conventional techniques and new emerging technologies with potential to impact the area of image-guided surgery of brain tumors. Emphasis is placed on techniques based on endogenous fluorescence lifetime contrast and their potential for intraoperative diagnosis of brain tumors.

SELECTION OF CITATIONS
SEARCH DETAIL
...