Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 98
Filter
1.
Respir Investig ; 62(2): 247-251, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38241957

ABSTRACT

BACKGROUND: Chronic lymphocytic leukemia (CLL) is the most common type of leukemia in Western countries. Although various patterns of lung involvement with CLL have been reported, data on clinicoradiologic presentation are sparse. METHODS: A computer-assisted search was conducted to identify patients encountered at Mayo Clinic from 1998 to 2022 and had leukemic pulmonary infiltrates (LPI) with CLL demonstrated on lung biopsy. Medical records and chest imaging studies were reviewed to identify clinical and radiologic features. RESULTS: Among 13 patients, median age was 77 years (range: 60-88) and included 10 men (77 %). All patients were known to have CLL with a median duration of 96 months (range: 50-408), and none were on treatment. Most common symptoms were dyspnea (62 %), cough (54 %), and fatigue (46 %); 2 patients (15 %) were asymptomatic. Dominant abnormality on CT consisted of single or multiple nodular/mass-like opacities in 10 patients (77 %), while diffuse centrilobular nodules, pleural mass, and diffuse bronchial wall thickening were each seen in one patient, respectively; intrathoracic lymphadenopathy was present in all. After diagnosis of LPI, treatment for CLL was administered to 7 patients (54 %); 6 patients (86 %) exhibited improvement. During follow-up (median 41 months), 8 (62 %) patients died. Causes of death included progressive CLL or treatment-related complications (2 patients), pneumonia (1 patient), unrelated causes (3 patients), and unknown in 2 patients. CONCLUSIONS: LPI in CLL is generally encountered in patients with known untreated CLL. The main imaging feature is single mass-like opacity or multiple nodular/mass-like opacities, associated with intrathoracic lymphadenopathy.


Subject(s)
Leukemia, Lymphocytic, Chronic, B-Cell , Lymphadenopathy , Pneumonia , Male , Humans , Aged , Leukemia, Lymphocytic, Chronic, B-Cell/complications , Leukemia, Lymphocytic, Chronic, B-Cell/diagnostic imaging , Leukemia, Lymphocytic, Chronic, B-Cell/pathology , Lymphadenopathy/etiology , Lymphadenopathy/complications
4.
J Clin Rheumatol ; 29(3): 151-158, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-36729874

ABSTRACT

BACKGROUND/OBJECTIVE: A subset of patients with idiopathic inflammatory myopathy (IIM) develops highly fatal, rapidly progressive interstitial lung disease (RP-ILD). Treatment strategies consist of glucocorticoid and adjunctive immunosuppressive therapies. Plasma exchange (PE) is an alternative therapy, but its benefit is unclear. In this study, we aimed to determine whether PE benefited outcomes for patients with RP-ILD. METHODS: In this medical records review study, we compared baseline characteristics and clinical outcomes for 2 groups of patients with IIM-related RP-ILD: those who received and did not receive PE. RESULTS: Our cohort consisted of 15 patients, 9 of whom received PE. Baseline demographic characteristics and severity of lung, skin, and musculoskeletal disease between the 2 groups of patients were not significantly different. Five patients required mechanical ventilation (2, PE; 3, no PE). Plasma exchange was generally a third-line adjunctive treatment option. The PE group had a longer median (interquartile range) hospitalization (27.0 [23.0-36.0] days) than the non-PE group (12.0 [8.0-14.0] days) ( p = 0.02). There was a potential benefit in 30-day mortality improvement in those receiving PE (0% vs 33%, p = 0.14), with a statistically significant improvement in 2 important composite end points including 30-day mortality or need for lung transplant (0% vs 50%, p = 0.04) and 1-year mortality or need for lung transplant or hospital readmission for RP-ILD in those receiving PE (22% vs 83%, p = 0.04). CONCLUSIONS: Plasma exchange may be an underutilized, safe salvage therapy for patients with IIM-related RP-ILD when other immunosuppressive therapies fail.


Subject(s)
Lung Diseases, Interstitial , Myositis , Humans , Plasma Exchange , Lung Diseases, Interstitial/therapy , Lung Diseases, Interstitial/complications , Myositis/complications , Myositis/therapy , Lung , Plasmapheresis , Autoantibodies , Retrospective Studies
5.
J Comput Assist Tomogr ; 47(2): 229-235, 2023.
Article in English | MEDLINE | ID: mdl-36573321

ABSTRACT

OBJECTIVE: To evaluate the diagnostic quality of photon-counting detector (PCD) computed tomography (CT) in patients undergoing lung cancer screening compared with conventional energy-integrating detector (EID) CT in a prospective multireader study. MATERIALS: Patients undergoing lung cancer screening with conventional EID-CT were prospectively enrolled and scanned on a PCD-CT system using similar automatic exposure control settings and reconstruction kernels. Three thoracic radiologists blinded to CT system compared PCD-CT and EID-CT images and scored examinations using a 5-point Likert comparison score (-2 [left image is worse] to +2 [left image is better]) for artifacts, sharpness, image noise, diagnostic image quality, emphysema visualization, and lung nodule evaluation focusing on the border. Post hoc correction of Likert scores was performed such that they reflected PCD-CT performance in comparison to EID-CT. A nonreader radiologist measured objective image noise. RESULTS: Thirty-three patients (mean, 66.9 ± 5.6 years; 11 female; body mass index; 30.1 ± 5.1 kg/m 2 ) were enrolled. Mean volume CT dose index for PCD-CT was lower (0.61 ± 0.21 vs 0.73 ± 0.22; P < 0.001). Pooled reader results showed significant differences between imaging modalities for all comparative rankings ( P < 0.001), with PCD-CT favored for sharpness, image noise, image quality, and emphysema visualization and lung nodule border, but not artifacts. Photon-counting detector CT had significantly lower image noise (74.4 ± 10.5 HU vs 80.1 ± 8.6 HU; P = 0.048). CONCLUSIONS: Photon-counting detector CT with similar acquisition and reconstruction settings demonstrated improved image quality and less noise despite lower radiation dose, with improved ability to depict pulmonary emphysema and lung nodule borders compared with EID-CT at low-dose lung cancer CT screening.


Subject(s)
Emphysema , Lung Neoplasms , Pulmonary Emphysema , Humans , Female , Early Detection of Cancer , Prospective Studies , Lung Neoplasms/diagnostic imaging , Photons , Phantoms, Imaging , Tomography, X-Ray Computed/methods
6.
Nat Commun ; 13(1): 4954, 2022 Aug 24.
Article in English | MEDLINE | ID: mdl-36002458

ABSTRACT

Polyolefin catalysts are characterized by their hierarchically complex nature, which complicates studies on the interplay between the catalyst and formed polymer phases. Here, the missing link in the morphology gap between planar model systems and industrially relevant spherical catalyst particles is introduced through the use of a spherical cap Ziegler-type catalyst model system for the polymerization of ethylene. More specifically, a moisture-stable LaOCl framework with enhanced imaging contrast has been designed to support the TiCl4 pre-active site, which could mimic the behaviour of the highly hygroscopic and industrially used MgCl2 framework. As a function of polymerization time, the fragmentation behaviour of the LaOCl framework changed from a mixture of the shrinking core (i.e., peeling off small polyethylene fragments at the surface) and continuous bisection (i.e., internal cleavage of the framework) into dominantly a continuous bisection model, which is linked to the evolution of the estimated polyethylene volume and the fraction of crystalline polyethylene formed. The combination of the spherical cap model system and the used advanced micro-spectroscopy toolbox, opens the route for high-throughput screening of catalyst functions with industrially relevant morphologies on the nano-scale.

7.
J Am Chem Soc ; 144(33): 15047-15058, 2022 Aug 24.
Article in English | MEDLINE | ID: mdl-35951390

ABSTRACT

Oxide-derived copper electrodes have displayed a boost in activity and selectivity toward valuable base chemicals in the electrochemical carbon dioxide reduction reaction (CO2RR), but the exact interplay between the dynamic restructuring of copper oxide electrodes and their activity and selectivity is not fully understood. In this work, we have utilized time-resolved surface-enhanced Raman spectroscopy (TR-SERS) to study the dynamic restructuring of the copper (oxide) electrode surface and the adsorption of reaction intermediates during cyclic voltammetry (CV) and pulsed electrolysis (PE). By coupling the electrochemical data to the spectral features in TR-SERS, we study the dynamic activation of and reactions on the electrode surface and find that CO2 is already activated to carbon monoxide (CO) during PE (10% Faradaic efficiency, 1% under static applied potential) at low overpotentials (-0.35 VRHE). PE at varying cathodic bias on different timescales revealed that stochastic CO is dominant directly after the cathodic bias onset, whereas no CO intermediates were observed after prolonged application of low overpotentials. An increase in cathodic bias (-0.55 VRHE) resulted in the formation of static adsorbed CO intermediates, while the overall contribution of stochastic CO decreased. We attribute the low-overpotential CO2-to-CO activation to a combination of selective Cu(111) facet exposure, partially oxidized surfaces during PE, and the formation of copper-carbonate-hydroxide complex intermediates during the anodic pulses. This work sheds light on the restructuring of oxide-derived copper electrodes and low-overpotential CO formation and highlights the power of the combination of electrochemistry and time-resolved vibrational spectroscopy to elucidate CO2RR mechanisms.

8.
Invest Radiol ; 57(11): 734-741, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-35703439

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0-33, likely absent; 34-66, indeterminate; 67-100, likely present). Radiologists also rated confidence for the probability of UIP (0-20, normal; 21-40, inconsistent with UIP; 41-60, indeterminate UIP; 61-81; probable UIP; 81-100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. RESULTS: A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDI vol , 7.88 mGy) and research PCD-CT (median CTDI vol , 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings ( P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507-0.818 vs 0.601-0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). CONCLUSIONS: Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.


Subject(s)
Idiopathic Pulmonary Fibrosis , Aged , Humans , Lung/diagnostic imaging , Middle Aged , Phantoms, Imaging , Photons , Tomography, X-Ray Computed/methods
9.
Respir Med ; 194: 106761, 2022 04.
Article in English | MEDLINE | ID: mdl-35217402

ABSTRACT

INTRODUCTION: Amyloid transthyretin amyloidosis (ATTR) is characterized by deposition of a misfolded conformation of the transport protein TTR, most commonly in cardiac and nerve tissue, causing clinical disease. Pulmonary amyloidosis, or deposition of ATTR in lung tissue, is a poorly characterized manifestation of this disease. We present the clinical course, imaging characteristics, pathology results, and outcomes of a patient cohort diagnosed with pulmonary ATTR. METHODS: We retrospectively reviewed records of 28 patients with pulmonary ATTR seen at Mayo Clinic from September 30, 2005, through December 31, 2020. Data collected included information on demographics, subjective symptoms, tissue biopsy results, pulmonary function testing, imaging findings, and treatment. RESULTS: Of the patients, 89% were men; the median age was 74.5 years (range, 50-99 years). Patients were typically diagnosed after persistent dyspnea and abnormal chest imaging resulted in lung biopsy, which yielded the ATTR diagnosis. Most patients had a preexisting diagnosis of cardiac ATTR. The disease was wild-type in 62% and hereditary in 38%. Normal pulmonary function tests followed by a restrictive pattern were the most common presentation. Of the patients, 93% had chest computed tomography, with common findings of diffuse nodularity, calcified granulomas, interlobular septal thickening, and pleural effusions. Almost all patients had pulmonary vascular involvement, and half had interstitial involvement on tissue biopsy. One-third received either anti-amyloid pharmacotherapy or a heart transplant. Half of patients had died before the time of study inclusion. CONCLUSION: Pulmonary disease is a less common but clinically important manifestation of ATTR.


Subject(s)
Amyloid Neuropathies, Familial , Lung Diseases , Aged , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/diagnostic imaging , Humans , Lung/pathology , Lung Diseases/diagnostic imaging , Male , Retrospective Studies
10.
Nat Mater ; 21(5): 572-579, 2022 May.
Article in English | MEDLINE | ID: mdl-35087238

ABSTRACT

Metal-zeolite composites with metal (oxide) and acid sites are promising catalysts for integrating multiple reactions in tandem to produce a wide variety of wanted products without separating or purifying the intermediates. However, the conventional design of such materials often leads to uncontrolled and non-ideal spatial distributions of the metal inside/on the zeolites, limiting their catalytic performance. Here we demonstrate a simple strategy for synthesizing double-shelled, contiguous metal oxide@zeolite hollow spheres (denoted as MO@ZEO DSHSs) with controllable structural parameters and chemical compositions. This involves the self-assembly of zeolite nanocrystals onto the surface of metal ion-containing carbon spheres followed by calcination and zeolite growth steps. The step-by-step formation mechanism of the material is revealed using mainly in situ Raman spectroscopy and X-ray diffraction and ex situ electron microscopy. We demonstrate that it is due to this structure that an Fe2O3@H-ZSM-5 DSHSs-showcase catalyst exhibits superior performance compared with various conventionally structured Fe2O3-H-ZSM-5 catalysts in gasoline production by the Fischer-Tropsch synthesis. This work is expected to advance the rational synthesis and research of hierarchically hollow, core-shell, multifunctional catalyst materials.

11.
Article in English | MEDLINE | ID: mdl-34948693

ABSTRACT

Solving environmental odor issues can be confounded by many analytical, technological, and socioeconomic factors. Considerable know-how and technologies can fail to properly identify odorants responsible for the downwind nuisance odor and, thereby, focus on odor mitigation strategies. We propose enabling solutions to environmental odor issues utilizing troubleshooting techniques developed for the food, beverage, and consumer products industries. Our research has shown that the odorant impact-priority ranking process can be definable and relatively simple. The initial challenge is the prioritization of environmental odor character from the perspective of the impacted citizenry downwind. In this research, we utilize a natural model from the animal world to illustrate the rolling unmasking effect (RUE) and discuss it more systematically in the context of the proposed environmental odorant prioritization process. Regardless of the size and reach of an odor source, a simplification of odor character and composition typically develops with increasing dilution downwind. An extreme odor simplification-upon-dilution was demonstrated for the prehensile-tailed porcupine (P.T. porcupine); its downwind odor frontal boundary was dominated by a pair of extremely potent character-defining odorants: (1) 'onion'/'body odor' and (2) 'onion'/'grilled' odorants. In contrast with the outer-boundary simplicity, the near-source assessment presented considerable compositional complexity and composite odor character difference. The ultimate significance of the proposed RUE approach is the illustration of naturally occurring phenomena that explain why some environmental odors and their sources can be challenging to identify and mitigate using an analytical-only approach (focused on compound identities and concentrations). These approaches rarely move beyond comprehensive lists of volatile compounds emitted by the source. The novelty proposed herein lies in identification of those few compounds responsible for the downwind odor impacts and requiring mitigation focus.


Subject(s)
Body Odor , Odorants , Animals , Industry
12.
J Am Coll Radiol ; 18(9): 1267-1279, 2021 09.
Article in English | MEDLINE | ID: mdl-34246574

ABSTRACT

The ACR Incidental Findings Committee presents recommendations for managing incidentally detected lung findings on thoracic CT. The Chest Subcommittee is composed of thoracic radiologists who endorsed and developed the provided guidance. These recommendations represent a combination of current published evidence and expert opinion and were finalized by informal iterative consensus. The recommendations address commonly encountered incidental findings in the lungs and are not intended to be a comprehensive review of all pulmonary incidental findings. The goal is to improve the quality of care by providing guidance on management of incidentally detected thoracic findings.


Subject(s)
Incidental Findings , Tomography, X-Ray Computed , Consensus , Humans , Lung , Radiologists
13.
Chemphyschem ; 22(15): 1595-1602, 2021 Aug 04.
Article in English | MEDLINE | ID: mdl-34133834

ABSTRACT

Operando shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS) with on-line mass spectrometry (MS) has been used to investigate the surface species, such as NO, NOH, NO2 , N2 O, and reaction products of the NO reduction reaction with CO and H2 over supported Rh-based catalysts in the form of catalyst extrudates. By correlating surface intermediates and reaction products, new insights in the reaction mechanism could be obtained. Upon applying different reaction conditions (i. e., H2 or CO), the selectivity of the catalytic reaction could be tuned towards the formation of N2 . Furthermore, in the absence of Rh, no reaction products were detected. The importance of the operando SHINERS as a surface-sensitive characterization technique in the field of heterogeneous catalysis provides routes towards a better understanding of catalytic performance.

14.
Am J Surg Pathol ; 45(7): 871-884, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33935155

ABSTRACT

Interstitial lung diseases (ILDs) in patients with shortened telomeres have not been well characterized. We describe demographic, radiologic, histopathologic, and molecular features, and p16 expression in patients with telomeres ≤10th percentile (shortened telomeres) and compare them to patients with telomere length >10th percentile. Lung explants, wedge biopsies, and autopsy specimens of patients with telomere testing were reviewed independently by 3 pathologists using defined parameters. High-resolution computed tomography scans were reviewed by 3 radiologists. p16-positive fibroblast foci were quantified. A multidisciplinary diagnosis was recorded. Patients with shortened telomeres (N=26) were morphologically diagnosed as usual interstitial pneumonia (UIP) (N=11, 42.3%), chronic hypersensitivity pneumonitis (N=6, 23.1%), pleuroparenchymal fibroelastosis, fibrotic nonspecific interstitial pneumonia, desquamative interstitial pneumonia (N=1, 3.8%, each), and fibrotic interstitial lung disease (fILD), not otherwise specified (N=6, 23.1%). Patients with telomeres >10th percentile (N=18) showed morphologic features of UIP (N=9, 50%), chronic hypersensitivity pneumonitis (N=3, 16.7%), fibrotic nonspecific interstitial pneumonia (N=2, 11.1%), or fILD, not otherwise specified (N=4, 22.2%). Patients with shortened telomeres had more p16-positive foci (P=0.04). The number of p16-positive foci correlated with outcome (P=0.0067). Thirty-nine percent of patients with shortened telomeres harbored telomere-related gene variants. Among 17 patients with shortened telomeres and high-resolution computed tomography features consistent with or probable UIP, 8 (47.1%) patients showed morphologic features compatible with UIP; multidisciplinary diagnosis most commonly was idiopathic pulmonary fibrosis (N=7, 41.2%) and familial pulmonary fibrosis (N=5, 29%) in these patients. In conclusion, patients with shortened telomeres have a spectrum of fILDs. They often demonstrate atypical and discordant features on pathology and radiology leading to diagnostic challenges.


Subject(s)
Lung Diseases, Interstitial , Lung , Molecular Diagnostic Techniques , Telomere Shortening , Telomere/pathology , Tomography, X-Ray Computed , Adult , Aged , Biomarkers/analysis , Biopsy , Cyclin-Dependent Kinase Inhibitor p16/analysis , Diagnosis, Differential , Female , Fibroblasts/chemistry , Fibroblasts/pathology , Humans , Immunohistochemistry , Lung/chemistry , Lung/diagnostic imaging , Lung/pathology , Lung Diseases, Interstitial/diagnostic imaging , Lung Diseases, Interstitial/genetics , Lung Diseases, Interstitial/pathology , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Telomere/genetics
15.
Angew Chem Int Ed Engl ; 60(30): 16576-16584, 2021 Jul 19.
Article in English | MEDLINE | ID: mdl-33852177

ABSTRACT

The electrocatalytic carbon dioxide (CO2 ) reduction reaction (CO2 RR) into hydrocarbons is a promising approach for greenhouse gas mitigation, but many details of this dynamic reaction remain elusive. Here, time-resolved surface-enhanced Raman spectroscopy (TR-SERS) is employed to successfully monitor the dynamics of CO2 RR intermediates and Cu surfaces with sub-second time resolution. Anodic treatment at 1.55 V vs. RHE and subsequent surface oxide reduction (below -0.4 V vs. RHE) induced roughening of the Cu electrode surface, which resulted in hotspots for TR-SERS, enhanced time resolution (down to ≈0.7 s) and fourfold improved CO2 RR efficiency toward ethylene. With TR-SERS, the initial restructuring of the Cu surface was followed (<7 s), after which a stable surface surrounded by increased local alkalinity was formed. Our measurements revealed that a highly dynamic CO intermediate, with a characteristic vibration below 2060 cm-1 , is related to C-C coupling and ethylene production (-0.9 V vs. RHE), whereas lower cathodic bias (-0.7 V vs. RHE) resulted in gaseous CO production from isolated and static CO surface species with a distinct vibration at 2092 cm-1 .

16.
Chest ; 160(2): 624-632, 2021 08.
Article in English | MEDLINE | ID: mdl-33647249

ABSTRACT

BACKGROUND: Exogenous lipoid pneumonia (ELP) develops when lipid-containing substances enter the airways through aspiration or inhalation and incite an inflammatory response. The diagnosis of ELP often is difficult because findings may be nonspecific. The clinical course of ELP has not been well characterized. RESEARCH QUESTION: What are the presenting clinicoradiologic features of ELP, its causative agents, and clinical course? STUDY DESIGN AND METHODS: We searched the Mayo Clinic electronic medical records for patients diagnosed with ELP between 1998 and 2020. Inclusion diagnostic criteria were: (1) lipoid pneumonia (LP) on histopathologic examination, (2) lipid-laden macrophages in BAL fluid, or (3) fatty attenuation of parenchymal opacities on chest CT imaging. Additionally, all patients were required to have a clinician diagnosis of LP in the absence of conditions known to cause endogenous LP. RESULTS: Thirty-four patients were identified. Mean age was 71 years, with no sex predominance; one-half were asymptomatic. The diagnosis was confirmed by lung biopsy (including three lobectomies for suspected malignancy) in 71% of patients, CT scan in 24% of patients, and BAL in 5% of patients. Most patients manifested bilateral parenchymal opacities that commonly involved the lower lobes; fatty attenuation was identifiable in only 41% of patients. A causative substance was identified in 79% of patients, in most cases after the diagnosis was established. Over a median follow-up of 1.2 years, only 20% of patients with chronic respiratory symptoms improved, whereas 50% worsened. Over a median follow-up interval of 1 year, CT scan abnormalities improved or resolved in 33% of patients and progressed in 39% of patients. Patients who deteriorated were older, with a higher prevalence of GI disorders than those who remained stable or improved. INTERPRETATION: ELP often is asymptomatic and may not manifest fatty attenuation on chest CT imaging. Clinical and radiologic abnormalities persist or worsen in most affected patients, even when the causative agent is discontinued.


Subject(s)
Pneumonia, Lipid/diagnosis , Pneumonia, Lipid/etiology , Adult , Aged , Biopsy , Bronchoalveolar Lavage , Female , Humans , Male , Middle Aged , Respiratory Function Tests , Severity of Illness Index , Tomography, X-Ray Computed , United States
17.
Polymers (Basel) ; 12(12)2020 Nov 29.
Article in English | MEDLINE | ID: mdl-33260375

ABSTRACT

Bisphenol A (BPA)-based epoxy resins have wide applications as food-contact materials such as metal can coatings. However, negative consumer perceptions toward BPA have driven the food packaging industry to develop other alternatives. In this study, four different metal cans and their lids manufactured with different BPA-replacement food-contact coatings are subjected to migration testing in order to identify migratory chemical species from the coatings. Migration tests are conducted using food simulants and conditions of use corresponding to the intended applications and regulatory guidance from the U.S. Food and Drug Administration. Extracts are analyzed by gas chromatography mass spectrometry (GC-MS) and high resolution GC-MS. The migratory compounds identified include short chain cyclic polyester migrants from polyester-based coatings and bisphenol-type migrants including tetramethyl bisphenol F (TMBPF), tetramethyl bisphenol F diglycidyl ether (TMBPF DGE), bisphenol F (BPF), bisphenol C (BPC), and other related monomers or oligomers. The concentration of the migrants is estimated using an internal standard, and validated trimethylsilyl (TMS) derivatization GC-MS methods are developed to specifically quantify TMBPF, BPF, BPC, and BPA in the coatings. The results will aid the safety evaluation of new food-contact material coating technology based on TMBPF chemistry and will provide an important reference for the industry in identifying and quantifying non-BPA coating-borne migrants.

18.
Respir Med ; 174: 106200, 2020.
Article in English | MEDLINE | ID: mdl-33147563

ABSTRACT

BACKGROUND: Primary Sjögren's Syndrome (pSS) is characterized by an immune-mediated lymphoplasmacytic infiltration of the salivary and lacrimal glands. Pulmonary nodules are not uncommonly encountered in these patients. METHODS: We conducted a retrospective computer-assisted search for patients with pSS who were encountered at our institution between 1999 and 2018 and had histologically characterized pulmonary nodule(s)/mass (es) (PNs). RESULTS: Of 41 patients with pSS and PNs, median age was 67 years (IQR, 56-74), 94% were women, and 39% had a smoking history. The PNs proved to be non-Hodgkin lymphoma (NHL) in 16 patients (39%), lung carcinoma in 11 patients (27%), other malignancies in 2 patients (5%), and benign diseases in remaining 12 patients (29%), including 7 with amyloidomas. Patients with NHL were younger (p = 0.006) while smoking exposure was more prevalent in patients with lung carcinoma (p = 0.022). Patients with NHL had a higher number of PNs and more often manifested random distribution, cysts, ground-glass changes and consolidations. Upper and/or mid-lung location, spiculated borders, solitary nodule, increasing size, and higher SUVmean on FDG-PET scan were associated with lung carcinoma. At the end of follow-up (median 5.9 years), 8 patients (20%) had died and included 5 patients with lung carcinoma; no deaths were observed in the NHL group. CONCLUSIONS: The majority of biopsied PNs in patients with pSS were malignant, most commonly lymphomas. Smoking exposure, solitary nodule, and high FDG avidity were more frequently associated with lung carcinoma. The clinical context, CT and 18FDG-PET are complementary in the evaluation and management of PNs in patients with pSS.


Subject(s)
Carcinoma/etiology , Lung Neoplasms/etiology , Lymphoma, Non-Hodgkin/etiology , Sjogren's Syndrome/complications , Solitary Pulmonary Nodule/etiology , Aged , Carcinoma/diagnostic imaging , Carcinoma/pathology , Female , Humans , Lung/diagnostic imaging , Lung/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Lymphoma, Non-Hodgkin/diagnostic imaging , Lymphoma, Non-Hodgkin/pathology , Male , Middle Aged , Positron-Emission Tomography , Retrospective Studies , Smoking/adverse effects , Solitary Pulmonary Nodule/diagnostic imaging , Solitary Pulmonary Nodule/pathology , Tomography, X-Ray Computed
19.
ACS Nano ; 14(4): 3725-3735, 2020 Apr 28.
Article in English | MEDLINE | ID: mdl-32307982

ABSTRACT

An era of circularity requires robust and flexible catalysts and reactors. We need profound knowledge of catalytic surface reactions on the local scale (i.e., angstrom-nanometer), whereas the reaction conditions, such as reaction temperature and pressure, are set and controlled on the macroscale (i.e., millimeter-meter). Nanosensors operating on all relevant length scales can supply this information in real time during operando working conditions. In this Perspective, we demonstrate the potential of nanoscale sensors, with special emphasis on local molecular sensing with shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS) and local temperature sensing with luminescence thermometry, to acquire new insights of the reaction pathways. We also argue that further developments should be focused on local pressure measurements and on expanding the applications of these local sensors in other areas, such as liquid-phase catalysis, electrocatalysis, and photocatalysis. Ideally, a combination of sensors will be applied to monitor catalyst and reactor "health" and serve as feedback to the reactor conditions.

20.
Molecules ; 24(19)2019 Oct 06.
Article in English | MEDLINE | ID: mdl-31590450

ABSTRACT

UV-curable inks, coatings, and adhesives are being increasingly used in food packaging systems. When exposed to UV energy, UV-photoinitiators (PI's) present in the formulations produce free radicals which catalyze polymerization of monomers and pre-polymers into resins. In addition to photopolymerization, other free radical reactions occur in these systems resulting in the formation of chemically varied photolytic decomposition products, many of which are low molecular weight chemical species with high migration potential. This research conducted model experiments in which 24 commonly used PI's were exposed to UV-energy at the typical upper limit of commercial UV-printing press conditions. UV-irradiated PI's were analyzed by gas chromatography-mass spectrometry (GC-MS) and electrospray-mass spectrometry (ESI-MS) in order to identify photolytic decomposition products. Subsequently, migration studies of 258 UV-cure food packaging samples were conducted using GC-MS; PI's and photolytic decomposition products were found in nearly all samples analyzed. One hundred-thirteen photolytic decomposition products were identified. Eighteen intact PI's and 21 photolytic decomposition products were observed as migrants from the 258 samples analyzed, and these were evaluated for frequency of occurrence and migratory concentration range. The most commonly observed PI's were 2-hydroxy-2-methylpropiophenone and benzophenone. The most commonly observed photolytic decomposition products were 2,4,6-trimethylbenzaldehyde and 1-phenyl-2-butanone. This compilation of PI photolytic decomposition data and associated migration data will aid industry in identifying and tracing non-intentionally added substances (NIAS) in food packaging materials.


Subject(s)
Benzaldehydes/isolation & purification , Butanones/isolation & purification , Food Contamination/analysis , Food Packaging , Benzaldehydes/metabolism , Benzophenones/chemistry , Butanones/chemistry , Gas Chromatography-Mass Spectrometry , Molecular Structure , Photolysis , Propiophenones/chemistry , Spectrometry, Mass, Electrospray Ionization , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...